Using Acceleration Enveloping on Sleeve Bearings

Similar documents
Monitoring Radar Mechanical Drive Systems FAA's choice of monitoring solutions

Using Operating Deflection Shapes to Detect Faults in Rotating Equipment

Piedmont Chapter Vibration Institute Training Symposium 10 May, 2012 FIELD BALANCING OF ROTATING MACHINERY.

Using Operating Deflection Shapes to Detect Misalignment in Rotating Equipment

Chapter 3. Experimentation and Data Acquisition

CHAPTER 4 FAULT DIAGNOSIS OF BEARINGS DUE TO SHAFT RUB

ADAPTIVE TECHNOLOGY APPLICATION FOR VIBRATION-BASED DIAGNOSTICS OF ROLLER BEARINGS ON INDUSTRIAL PLANTS

RVS TECHNOLOGY TEST ON A GEAR TRANSMISSION

Polyflex JB and Micro-V Belt Drive Selection Procedures

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C

VIBRATION ANALYSIS AND REPAIR PROCESS FOR THE VENTILATION SYSTEM FOR SMOKE DRAIN IN THE THERMAL POWER PLANT

PERFORMANCE EVALUATION OF OVERLOAD ABSORBING GEAR COUPLINGS

SKF actuators available for quick delivery. Selection guide

Field Balancing Experiences

MSBCCL Series Asynchronous Three-Phase Brake Motors With Squirrel Cage Rotor Direct Current Brake

Multi-Speed Three-Phase Induction Motors

Stabilus gas springs. Linear Motion

Improving Electromotor Process in Water Pump by Using Power Spectral Density, Time Signal and Fault Probability Distribution Function

This Capstone Project will address the analysis and diagnosis of the Steam Turbo-Generator (STG) machine vibration problems in Thermal Power Plant

Advantages of Variable Frequency Drive Technology for Face Conveyor and Plow Systems in Longwall Mining

ROLLER BEARING FAILURES IN REDUCTION GEAR CAUSED BY INADEQUATE DAMPING BY ELASTIC COUPLINGS FOR LOW ORDER EXCITATIONS

ABSTRACT I. INTRODUCTION

An Introduction to Insulation Resistance Testing

ElectroMechanical Cylinder LEMC

1. Wind turbines are designed to operate within specified design criteria. Often the operating environment extends beyond these limits and causes

ElectroMechanical Cylinder LEMC

Vibration Survey & Analysis Report

Development of a diagnosis technique for failures of V-belts by a cross-spectrum method and a discriminant function approach

Safety Instrumented Systems & Functional safety of safety-related systems. A substantial new opportunity for Pfannenberg Signaling products

ZF Maschinenantriebe GmbH Industrial Drives. Planetary gearboxes Economy Series for Servomotors

Vibration Analysis of Shaft Misalignment and Diagnosis Method of Structure Faults for Rotating Machinery

Key Words: Lifetime Data Analysis (LDA), Probability Density Function (PDF), Goodness of fit methods, Chi-square method.

Rolling Element Bearing Faults Detection, Wavelet De-noising Analysis

AN-1301 APPLICATION NOTE

TECHNICAL INFORMATION Bulletin

Quick Reference. Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20

OFFSHORE. Advanced Weather Technology

RELIABILITY ANALYSIS OF E S R C 1400 BUCKET WHEEL EXCAVATORS OPERATING IN OLTENIA LIGNITE OPEN PIT MINES

CHAPTER 6 FAULT DIAGNOSIS OF UNBALANCED CNC MACHINE SPINDLE USING VIBRATION SIGNATURES-A CASE STUDY

Actuators with ball monorail guidance system and ball screw drive MKUVE15-KGT, MKUVE20-KGT

Bearing fault diagnosis based on EMD-KPCA and ELM

HEALTH MONITORING, FAULT DETECTION AND DIAGNOSIS IN INDUSTRIAL ROTATING MACHINERY BY ADVANCED VIBRATION ANALYSIS

ORTHOBLOC 3000 Drive systems Maintenance

Installation instructions, accessories. Snow chains

ISSP User Guide CY3207ISSP. Revision C

SSC-JE EE POWER SYSTEMS: GENERATION, TRANSMISSION & DISTRIBUTION SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL

Safety in Numbers SKYWATCH 497. The affordable original.

Development of Multi-Unit Dependency Evaluation Model Using Markov Process and Monte Carlo Method

An Integrated Study of a Gearbox Failure

Gear Health Monitoring and Prognosis

PUMP PERFORMANCE MEASUREMENTS Jacques Chaurette p. eng. April 2003

Sensorless frequencyconverter-based. for LCC efficient pump and fan systems

Vibration Signals Analysis and Condition Monitoring of Centrifugal Pump

FOREMAN ASSEMBLY / OWNER S MANUAL

Ambient Weather WS-152B 6" Contemporary Barometer User Manual

FULL SPECTRUM ANALYSIS IN JOURNAL BEARING DIAGNOSTICS

Drive Shaft Failure of Z-Drive Propulsion System. Suzanne Higgins

Computational and Experimental Approach for Fault Detection of Gears

INSTALLING TRAK SPORT TIRE CHAINS ON 20 MODEL 3 TIRES

Overview of Control System Design

USS ProCoil Company. WELCOME To Micrometer Training. Introduction and Lecture Phase I 6/18/2010

product manual H-4204 Proving Ring Penetrometer

APEX DYNAMICS, INC. Staianless

Surface Mount Multilayer Ceramic Chip Capacitors for Safety Certified Applications

ABSTRACT I. INTRODUCTION

The Vaisala AUTOSONDE AS41 OPERATIONAL EFFICIENCY AND RELIABILITY TO A TOTALLY NEW LEVEL.

Fischer Instruments Stainless Steel Barometer User Manual

RISK RATING SAFE WORK METHOD STATEMENT 1 HIGH 2 MEDIUM 3LOW. I approve the use of this Safe Work Method Statement: NAME: POSITION: Department Manager

Commissioning and Testing of AVR and PSS

PUSH TUBE STANDARD DUTY

Prognosis of gear health using stochastic dynamical models with online parameter estimation

HEAVY DUTY SWING-OUT VALVE

Conversion Kit for: 7620 and 7820 Swing-Out Valves ft-lbs ft-lbs 8835/ ft-lbs

Maintenance free operating period an alternative measure to MTBF and failure rate for specifying reliability?

Solid Tantalum SMD Capacitors TANTAMOUNT, Hi-Rel COTS, Low ESR, Metal Case

1 General introduction

W h y Co n s i d e r An y t h i n g El s e?

DRIFTER PLOW-IN-A-BOX

/2" Heavy Duty Swing-Out

143 EEX gerotor pump unit. For use in oil circulation systems in gas- and dust-ex-atmospheres

P R O G N O S T I C S

Intelligent Fault Classification of Rolling Bearing at Variable Speed Based on Reconstructed Phase Space

Department of Mechanical FTC College of Engineering & Research, Sangola (Maharashtra), India.

Detection of Severity of Bearing Cage fault of Induction Motor with Externally Induced Vibration

A nonlinear dynamic vibration model of defective bearings: The importance of modelling the finite size of rolling elements

5. DRIVE 1. SAFETY 2. PREPARATION 3. FRAME 4. TRANSMISSION 6. ROW UNIT 7. OPTIONAL EQUIPMENT

Methods For Reducing Vibration (Intro to Vibration Control) Robert J. Sayer, PE President, The Vibration Institute Owner, Applied Structural Dynamics

ISO INTERNATIONAL STANDARD. Rolling bearings Linear motion rolling bearings Part 2: Static load ratings

Facing the winter challenges for railways in Europe - Winter & Railways Fact Sheet Root Causes Rolling Stock and Infrastructure UIC Survey Evaluation

product manual H-3220A Benkelman Beam

PFA HP Plus GBK Lining Sheet

Motors Automation Energy Transmission & Distribution Coatings. Servo Drive SCA06 V1.5X. Addendum to the Programming Manual SCA06 V1.

Dynamic Braking Resistor Calculator

Eppendorf BioSpectrometer 6135/6136/6137

INSTALLATION INSTRUCTIONS FRONT PLOW MOUNT KIT Part Number: Application: Polaris Sportsman 400, 500, 800

Fischer Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual

Service Information Letter SIL # 017

S.C. Rulmenti S.A. Barlad Romania Republicii Street No

Advanced Field Single Plane Trim Balancing

ASSEMBLY / OWNER S MANUAL

Transcription:

SKF Reliability Systems Using Acceleration Enveloping on Sleeve Bearings By Wane Wier SKF Reliability Systems and Dragan Trivanovic Senior Reliability Engineer, Teckcominco Introduction SKF has a long history of using Enveloping as part of a multiparameter condition monitoring approach. The multi-parameter approach typically includes vibration velocity, acceleration, and enveloped acceleration measurements, along with temperature measurements. Traditionally, enveloped acceleration measurements are performed on rolling element bearings, gearboxes, and other components that tend to generate impulsive type fault signals. Application Note CM3093 Sleeve bearings have not typically fallen into this category, and vibration monitoring on machinery using these types of bearings normally employs noncontact eddy current probes, especially in the machinery protection arena. However, Dragan Trivanovic, a Senior Reliability Engineer with Teckcominco, has experienced cases where he successfully detected failed sleeve bearings prior to what would have been a catastrophic failure using a CMVA 60 Microlog and enveloped acceleration measurements. For detection purposes, Enveloping Filter Band 3 was employed for almost all of the measurements, using 1600 lines of resolution, and an Fmax of 100 kcpm. Upon detection, if a measurement started to indicate a developing problem, then The SKF Microlog CMVA 60 Portable Data Collector/Analyzer. analysis would continue with higher resolution measurements. This Application Note will present two of the four cases that Dragan has submitted for this study. In the first case, a failed sleeve bearing was detected on an absorption fan, and with the second case, a failed sleeve bearing was detected on a bypass fan. Case 1: Absorption Fan Bearing Failure This case involved an absorption fan driven by a 1250 HP motor. The variable speed

Using Acceleration Enveloping on Sleeve Bearings 2 Figure 1. Absorption Fan Enveloped Acceleration Waterfall Plot. motor drives 87 x 26 fan runners on 4-7/16 shaft Dodge sleeve bearings. Operating speed is typically 940 RPM. Figure 1 shows the fan s enveloped acceleration waterfall spectrum. We observe signs of looseness indicated by 1/2X harmonics. The drive end bearing was indeed damaged, and was replaced after the 12/1/2002 measurement. Vibration velocity and temperature were also measured. The velocity readings did not indicate any bearing problems, although there was a slightly elevated 1X. Engineering suspected that there was dirt on the runners. The temperature trend on the failed bearing never reached alarm setpoints. In fact, temperature values remained relatively stable throughout the entire period shown in the waterfall spectrum. The bearing probably would have been lost completely if only temperature readings were used. Figures 2 and 3, the pictures illustrate the damaged bearing and the scraping damage to the shaft. As seen in the pictures, both the bearing and the shaft were damaged. The bearing wear was 8 mils, the shaft wear was 12 mils. In this case, sanding the shaft down using 600- grade sandpaper and scraping the bearing allowed both to be salvaged, and took only six hours to perform. Had this bearing completely failed, the estimated downtime would have been seven days, and would have resulted in more than $700,000 USD in lost revenue.

Using Acceleration Enveloping on Sleeve Bearings 3 Figure 2. Absorption Fan, Bearing Damage. Figure 3. Absorption Fan, Shaft Damage.

Using Acceleration Enveloping on Sleeve Bearings 4 Case 2: Bypass Fan Bearing Failure This case involves a bypass fan driven by a 600 HP, 1798 RPM motor. The variable speed clutch drives a Sheldon Fan with 50 x 18 runners on 3-7/16 x 100 shaft. Dodge sleeve bearings were being used, and typical operating speeds were between 450 to 800 RPM. Figure 4 shows the enveloped acceleration measurement s overall trend, with some relatively high readings going in and out of alert. The last two readings were taken before and after the bearing was replaced. The day before the bearing was replaced, the value was about 2.3 ge, which dropped to 0.4296 ge after the bearing was replaced. Figure 5 shows the overlaid spectra of the last two readings: one before (shown in red), and one after bearing replacement. The red spectrum shows signs of looseness, with 2X being the highest peak, which was caused by shaft movement due to wear. As with the previous case, the velocity trend did not show much. However, the velocity spectrum did have some activity (see Figures 6 and 7). The velocity spectrum has high peaks that belong to motor speed and 1X, 2X, and 3X components caused by misalignment. Fan speed harmonics (660 RPM), shown in red, are very low in the velocity spectrum. Figure 4. Enveloped Acceleration Overall Trend.

Using Acceleration Enveloping on Sleeve Bearings 5 Figure 5. Overlaid Enveloped Acceleration Spectra for Last Two Measurements. Figure 6. Velocity Trend.

Using Acceleration Enveloping on Sleeve Bearings 6 Figure 7. Velocity Spectrum. Figure 8. DCS Trend.

Using Acceleration Enveloping on Sleeve Bearings By Wane Wier SKF Reliability Systems and Dragan Trivanovic Senior Reliability Engineer, Teckcominco SKF Reliability Systems 5271 Viewridge Court San Diego, California 92123 USA Telephone (+1) 858-496-3400 FAX (+1) 858-496-3531 In addition to collecting vibration data with the Microlog, a Foxboro DCS was monitoring velocity and temperature readings. However, the trends shown in the DCS were flat and did not indicate any problems. In Figure 8, the left part of the trend shows the velocity readings before the bearing was replaced, and the far right side shows the readings after the bearing was replaced. The spikes created between the two were created during the repair. An interesting observation is that the far right part of the trend actually shows higher velocity readings than before the bearing was replaced. This is because the new bearing was installed on the same damaged shaft. It turns out that the shaft was worn by 22 mils, and to replace it would have been a four day job. It was decided that we should wait until the next planned shut down to make repairs, and in the meantime investigate the feasibility of performing a repair in place using a Belzona or similar product instead of replacing the entire shaft. Conclusion Since the shaft and sleeve bearings were repaired, both the machines and the bearings have run without incident. In the case of the bypass fan, the sleeve bearing was replaced with a rolling element bearing. Although seldom used in sleeve bearing applications, enveloped acceleration measurements have proven to be a useful tool for early detection of sleeve bearing equipment problems. In this case, metalto-metal contact provided a clear indication of a problem. From an economic standpoint, the case studies show that catastrophic and unplanned shutdowns were diverted, saving both time and money, and minimizing the risk to safety. Web: Although care has been taken to assure the accuracy of the data compiled in this publication, SKF does not assume any liability for errors or omissions. SKF reserves the right to alter any part of this publication without prior notice. SKF is a registered trademark of SKF. All other trademarks are the property of their respective owners. CM3093 (5-04) Copyright 2004 by SKF Reliability Systems ALL RIGHTS RESERVED