Micro Pixel Chamber with resistive electrodes for spark reduction

Similar documents
GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

Development of New MicroStrip Gas Chambers for X-ray Applications

TitleDevelopment of an MeV gamma-ray ima. works must be obtained from the IEE

GEM: A new concept for electron amplification in gas detectors

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

arxiv:physics/ v2 27 Mar 2001

Electron transparency, ion transparency and ion feedback of a 3M GEM

Breakdown limit studies in high-rate gaseous detectors

Development of a new MeV gamma-ray camera

Advances in the Micro-Hole & Strip Plate gaseous detector

Micro-pattern gaseous detectors

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

Detectors in Nuclear and High Energy Physics. RHIG summer student meeting June 2014

Performance study of the ceramic THGEM *

Recent developments on Micro-Pattern Gaseous Detectors

GEM-based photon detector for RICH applications

Nuclear Instruments and Methods in Physics Research A

Simulation of GEM-TPC Prototype for the Super-FRS Beam Diagnostics System at FAIR

Precision Calibration of Large Area Micromegas Detectors Using Cosmic Muons

Micro Pixel Chamber Operation with Gas Electron Multiplier

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

R&D on Astroparticles Detectors. (Activity on CSN )

NEW DEVELOPMENTS IN GASEOUS DETECTORS. Fabio Sauli. CERN, Geneva, Switzerland

Performance of a triple-gem detector for high-rate particle triggering

General Overview of Gas Filled Detectors

Discharge studies in Micromegas detectors in low energy hadron beams

A proposal to study gas gain fluctuations in Micromegas detectors

A Triple-GEM Telescope for the TOTEM Experiment

Drift plane. substrate (20ÉIm polyimide) 200ÉIm. Back strip (180ÉIm width) Base (Ceramic) Anode strip (10ÉIm width) Cathode strip (100ÉIm width)

Results with Micromegas modules at LP-TPC

Study of GEM-like detectors with resistive electrodes for RICH applications

Performance of the Gamma-ray Imaging Detector with Micro-TPC

A new detector for neutron beam monitoring

arxiv:physics/ v2 [physics.ins-det] 31 Oct 2003

Evaluation and reduction of ion back-flow in multi-gem detectors

Development and preliminary tests of resistive microdot and microstrip detectors

arxiv: v1 [physics.ins-det] 7 Dec 2018

arxiv: v2 [physics.ins-det] 30 Jul 2012

R&D and related Simulation Studies for the sphenix Time Projection Chamber

Progress in the Development of Photosensitive GEMs with Resistive Electrodes Manufactured by a Screen Printing Technology

arxiv: v1 [physics.ins-det] 28 Mar 2016

A novel design of the MeV gamma-ray imaging detector with Micro-TPC

Design, construction and test of Boron Array Neutron Detector - Gas Electron Multiplier (BAND-GEM)

Chapter 3 Gas Filled Detectors

Development of gaseous PMT with micropattern gas detector

X-ray ionization yields and energy spectra in liquid argon

Silicon Detectors. Particle Physics

Lecture 18. New gas detectors Solid state trackers

Simulation and performance study of ceramic THGEM *

Neutron Structure Functions and a Radial Time Projection Chamber

Angular resolution of the gaseous micro-pixel detector Gossip

3 Gaseous Detectors. Detectors for Particle Physics Manfred Krammer Institute for High Energy Physics, Vienna, Austria

arxiv: v1 [physics.ins-det] 6 Aug 2015

An integrated Micromegas UV-photon detector

Tracking in a TPC. D. Karlen / U. Victoria & TRIUMF for the LCTPC collaboration

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

& SUN ZhiJia 1;2. Abstract

arxiv: v1 [physics.ins-det] 3 Jun 2016

MTV - S1183 Beam Time Summary. Performance test of MTV new detector : CDC. Yumi Totsuka. Department of Physics, Rikkyo University, Tokyo, Japan

Generic Detector. Layers of Detector Systems around Collision Point

PANDA-?? A New Detector for Dark Matter Search

Neutron imaging with a Micromegas detector

EEE4106Z Radiation Interactions & Detection

Recent Progress on D 3 - The Directional Dark Matter Detector

Light ion recoil detector

M. De Napoli, F. Giacoppo, G. Raciti, E. Rapisarda, C. Sfienti. Laboratori Nazionali del Sud (LNS) INFN University of Catania. IPRD Oct.

arxiv: v1 [astro-ph.im] 6 Dec 2010

X-ray ionization yields and energy spectra in liquid argon

THE MULTIGAP RESISTIVE PLATE CHAMBER. Abstract

SIMULATION OF CHARGED PARTICLE DETECTORS FOR FUTURE UPGRADES OF THE CMS EXPERIMENT AT THE LARGE HADRON COLLIDER

µ-pic gaseous area detector for small-angle X-ray scattering experiments

Precision neutron flux measurement with a neutron beam monitor

arxiv: v1 [physics.ins-det] 1 Nov 2011

Detectors for High Energy Physics

arxiv: v1 [physics.ins-det] 30 Mar 2014

High pressure xenon gas detector with segmented electroluminescence readout for 0nbb search

MICROMEGAS Signal: Numerical Simulation Based on Neon-Isobutane and Neon-DME

The Cylindrical GEM detector for the KLOE-2 Inner Tracker

On the Design Aspects Affecting Performance of GEM based Detector Development for Plasma Diagnostics

Signals in Particle Detectors (1/2?)

arxiv: v1 [physics.ins-det] 4 Nov 2013

Performance studies of MicroMegas for the ATLAS experiment

Creating Ti particles for liquid Xe purification

Spatial resolution measurement of Triple-GEM detector and diffraction imaging test at synchrotron radiation

MICROMEGAS PERFORMANCE BASED IN ARGON- ISOBUTANE AND ARGON-DEMETHYL-ETHER

Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal

Pressure effect in the X-ray intrinsic position resolution in noble gases and mixtures

3D Simulation of Electron and Ion Transmission of GEM-based Detectors

LABORATÓRIO DE INSTRUMENTAÇÃO E FÍSICA EXPERIMENTAL DE PARTÍCULAS

3. Gas Detectors General introduction

Multiple charge states of titanium ions in laser produced plasma

PoS(EPS-HEP2015)232. Performance of a 1 m 2 Micromegas Detector Using Argon and Neon based Drift Gases

Gas Electron Multiplier detectors with high reliability and stability. Abstract. Introduction

A fast triple GEM detector for high-rate charged-particle triggering

arxiv:physics/ v1 [physics.ins-det] 3 Jul 2006

Particle Energy Loss in Matter

Digital Hadron Calorimetry for the Linear Collider using GEM Technology

Microscopic Simulation of GEM Signals

A Complete Simulation of a Triple-GEM Detector

Transcription:

Micro Pixel Chamber with resistive electrodes for spark reduction arxiv:1310.5550v1 [physics.ins-det] 21 Oct 2013 Atsuhiko Ochi a, Yuki Edo a, Yasuhiro Homma a, Hidetoshi Komai a and Takahiro Yamaguchi a a Kobe University Kobe 657-8501, Japan E-mail: ochi@kobe-u.ac.jp August 30, 2018 Abstract The Micro Pixel Chamber (µ-pic) using resistive electrodes has been developed and tested. The surface cathodes are made from resistive material, by which the electrical field is reduced when large current is flowed. Two-dimensional readouts are achieved by anodes and pickup electrodes, on which signals are induced. High gas gain ( > 6 10 4 ) was measured using 55 Fe (5.9 kev) source, and very intensive spark reduction was attained under fast neutron. The spark rate of resistive µ-pic was only 10 4 times less than that of conventional µ-pic at the gain of 10 4. With these developments, a new MPGD with no floating structure is achieved, with enough properties of both high gain and good stability to detect MIP particles. In addition, µ-pic can be operated with no HV applied on anodes by using resistive cathodes. Neither AC coupling capacitors nor HV pull up resisters are needed for any anode electrode. Signal readout is drastically simplified by that configuration. keywords: Gaseous detector; Micropattern gaseous detectors (MSGC, GEM, THGEM, RETHGEM, MHSP, MICROPIC, MICROMEGAS, InGrid, etc), Micro pixel chamber 1 Introduction The µ-pic is one type of micro pattern gaseous detector (MPGD) [1, 2]. There is a dot of anode and a surrounded cathode for one pixel, and many of those are printed on substrate. Primary electrons in gas volume are drifted toward the anode, and those are multiplied by a gas avalanche mechanism due to higher electric field between anode and cathode. The µ-pic can be operated around 10 4 of gas multiplication, which enables us to detect the minimum ionized particle. However, if there are large energy deposits simultaneously, such as recoiled nuclei, discharge and spark probabilities are raised because of dense electrons called the Raether limit [3, 4, 5]. Those are a critical problem for using MPGD in intense hadron experiments. The most promising strategy for overcoming Corresponding author. 1

Figure 1: Schematic structure of µ-pic with resistive cathode. Cathodes are made from resistive material (surface resistivity is a few MΩ/sq.). Signals from cathodes are read from pickup electrodes as induced charge. the spark problem is to make the MPGDs using high resistive electrodes [6, 7]. In the early stages of our investigation, we tried to overcoat high resistivity materials on the cathode electrodes [8, 9]. However, the sparks could not be suppressed by those early prototypes. With the improvement of structure, separating the resistive cathode and pickup electrodes, both higher gaseous gain (more than 5 10 4 ) and strong spark reduction were achieved. The spark probabilities have been checked using fast neutron as a high ionizing particle (HIP). Those developments provide spark-free MPGD, which can be operated even in a next generation hadron collision experiment, where both MIP detection and HIP tolerance are required. 2 Design of detector The structure of the new detector is based on µ-pic [1, 2], which is one type of MPGD without floating structure, such as foils or mesh. Figure 1 shows a schematic structure of resistive cathode µ-pic. The cathode electrodes are made from resistive material, instead of metal electrodes of existing µ-pic. Huge current caused by spark or large energy deposits will reduce the electric field by higher resistive cathodes. Signals are read from both anodes and pickup electrodes. Those two types of readouts cross each other at right angles for detecting two-dimensional position. The pickup electrodes are placed along resistive cathodes below an insulating layer. The signals are induced on the pickup electrodes with capacitive coupling on the detector surface. In typical operation, static electrical field around the anode is quite the same as the existing µ-pic (cathodes are made from metal). Positive ions produced by gas multiplication drift toward the cathodes, and signals are induced on both anodes and pickup electrodes. Meanwhile, if there are large energy deposits or discharges, the electrical potential of the cathode is raised due to movement of a large amount of charge. It reduces the electric field around 2

the anode, and terminates the discharge immediately. Maximum charge of a spark will be limited by very small ( 0.1pF) capacitance of a single pixel. 3 Prototype production The prototype of the resistive cathode µ-pic was made using carbon-loaded polyimide, provided by Toray Industries, Inc. To make the resistive strips (cathode strips), images of surface cathode patterns were first etched on the PCB board. The carbon-loaded polyimide was laid on the surface, and remaining surface metal was removed chemically after curing the polyimide. Figure 2 shows the manufacturing process of the resistive cathode µ-pic. Those manufacturing processes were done by Raytech Inc. Our prototype has 10cm 10cm of detection area. The surface resistivity of the cathode strips is about 100 kω/sq. - 10MΩ/sq. Figure 3 shows a microscopic picture of the detector surface, and Figure 4 shows the magnified picture around one electrode. 4 Operation test The gaseous gain of the prototype was checked using 55 Fe source (5.9keV X-ray). Signals were observed from both anode and pickup strip. Signal lines were connected to ATLAS ASD [10] with analogue output as preamplifiers. The charges of the signals were measured by digital oscilloscope directly. The anodes and pickup signals have opposite signs but nearly identical charge in the same event. The gain curves were measured by the following four types of operation gases: Argon/ethane (7:3, 9:1) and Argon/CO 2 (7:3, 9:1). A drift plane is set at a 3-mm gap from the µ-pic board while applying voltage of -1 kv. Potential of the resistive cathodes was set to 0 V, and the anode voltage was changed for gain measurements. The maximum anode voltage was determined by spark starting limit; However, the spark current of this resistive chamber (around 100 na) was very low compared with conventional µ-pic (more than 1 µa). Figure 5 shows the results of gain measurements using those gases. The maximum gas gain was attained at 6 10 4 using Argon/ethane (7:3) mixture gas. The spark tolerances in HIP were measured using fast neutron irradiation on the chamber [8]. A neutron source was provided by the tandem electrostatic accelerator at the Kobe University Faculty of Maritime Science (Fig. 6). The 3-MeV deuteron beam generated by this accelerator was guided to a beryllium target placed at the end of the beam line. The neutron was produced by a 9 Be(d,n) 10 B exoergic (4 MeV) nuclear reaction. The peak neutron energy is estimated at 2.5 MeV. This facility can produce up to 10 8 neutrons in a second. Figure 7(a) shows the output current monitor for existing µ- PIC with 2.4 10 3 neutron/second irradiation, and Figure 7(b) shows resistive cathode µ-pic with 1.9 10 6 neutron/second irradiation. The gas gains of both setups were 15,000. We can see that the sparks were strongly suppressed, even with 900-times strong neutron. The spark rate is plotted in Figure 8 with the gas gain on the abscissa. This rate is defined as the ratio of huge sparks to the irradiated neutron numbers. The sparks were counted when the current monitor of the anode HV excess was 0.5 µa and 2 µa. Two resistive cathodes µ-pics (named RC27/RC28 in the figure 8) and conventional µ- PIC were tested. From those measurements, sparks in the resistive cathode µ-pic were reduced to 10 3 10 5 -times smaller than those of conventional µ-pic. 3

Figure 3: Microscopic picture of resistive µ- PIC. Strip pitch is 400µm. Potential of resistive strip is applied from downside crossbar in this picture. Figure 4: Three-dimensional magnified image of one pixel. 3D image taken by digital microscope with focal depth information. Figure 2: Manufacturing process of resistive µ-pic. Our prototypes are produced by RAYTECH Inc. 4

Figure 5: Gas gain of resistive µ-pic against anode voltage. Potential of resistive cathodes was set to 0. Four types of gas mixtures were tested: Argon/ethane = 7:3 and 9:1, Argon/CO 2 = 7:3 and 9:1. Gain of more than 60,000 was attained using Argon/ethane mixture. Figure 6: Picture of a Tandem Electrostatic Accelerator at the Maritime Science Faculty, Kobe University. Ion sources are generated at the top of the system (upper-left part of picture), and accelerated in tandem accelerator. Maximum achievable energy (for proton or deuteron) is about 3.5 MeV. 5

Figure 7: Anode current on µ-pic under intense neutron. (a) shows HV current using conventional µ-pic with 2.4 10 3 neutron/second irradiation. (b) shows HV current using resistive µ-pic with 1.9 10 6 neutron/second irradiation. There is no spark found in case (b) at this scope; nevertheless it is 10 3 -times more intense than case (a). Figure 8: Spark rates of conventional µ-pic and resistive µ-pics. 6

Figure 9: Figure (a) shows electron drift line by applying HV to resistive µ-pic as with conventional µ-pic. Positive HV is applied to anodes, and potential of cathodes is set to 0 V. Figure (b) shows applying shifted HV on electrodes. Negative HV is applied to cathodes, and anodes are connected to readout directly. In (b), neither bias resisters nor coupling capacitors are needed. 5 Novel Operation condition applying HV to resistive cathodes In the conventional operation setup, positive HV was applied on anodes and the potential of cathodes was set to 0 V, to make a high electric field around the anode pixels. The coupling capacitors and bias resisters were required for each anode strip to read signals. On the other hand, the potentials of pickup electrodes and cathodes can be independent in resistive µ-pic. Then, shifting the surface potentials, in which the anode potential is set to 0 V and resistive cathodes are applied negative voltage, is thought to work almost the same as the conventional setup. Neither decoupling capacitors nor bias resisters are needed on anodes. Pickup electrodes, as second coordinate signals, can also be connected to the readout directly. The capacitors and resisters for each electrode can be completely removed using this new operation. Difference between conventional and new operation modes is shown in Figure 9 with electron drift lines simulated using Garfield and Maxwell 3D. Both electron drift lines seem almost the same in those simulations. The gain curve and spark probabilities were measured in the new operation condition. The gain curve using Argon/ethane (7:3) mixture gas is shown in Figure 10. Operation voltage with the new operation was a bit greater than that with the conventional one. The time variability of the gain was found as shown in Figure 11. It is thought that this phenomenon is due to charge-up on the substrate. The gain became stable after 7

Figure 10: Gain curve of resistive µ- PIC with conventional operation and new operation. 5 5Fe (5.9keV) source was used with Argon/ethan (7:3) gas mixture. Figure 11: Time variability of gain on new operation mode. Gas gain of 8,000 at start grew to 25,000 after 2 10 7 counts/cm 2 X-ray (5.9keV) irradiation. 2 10 7 counts/cm 2 irradiation of incident 5.9keV ( 55 Fe) X-ray source. The maximum gain and shape of gain curves were almost the same. As shown in Figure 12, spark probabilities under fast neutron were also almost the same. 6 Discussion and future prospects The results from section 5 show the new operation condition is performed as well as the conventional one. The new one has a great advantage in terms of detector production because fewer electronic parts are needed. However, there are problems remaining for stable operation. Sometimes the pickup electrodes have been shorted to resistive cathodes. Two of three of our prototypes have been broken in this phenomenon. The withstanding electric field of polyimide is around 300 kv/mm, and the substrate thickness (between resistive cathode and pickup) is 25µm. The average electrical field in the substrate is estimated at around 20 kv/mm, which seems sufficiently lower than the withstanding field of polyimide. However, it is expected that the field at the edge of the electrodes will be higher. The electric fields around the cathode and pickup edge are simulated using Maxwell 3D as shown in Figure 13. Figure 14 shows the field strength along the line joining both the cathode and the pickup edge in Figure 13. The maximum field is about 200 kv/mm at the cathode edge, which is close to the withstanding field of polyimide. This simulation suggests that the margin of withstanding voltage is not sufficient. To improve it, thicker substrate will be used in the next prototype. 7 Conclusion The Micro Pixel Chamber with resistive cathodes and capacitive readout was developed and tested. More than 6 10 4 of gas gain was achieved stably, using 55 Fe source under Argon/ethane (7:3) gas mixture. The spark rates were also measured using intense fast ( 2MeV) neutrons. The spark rate of resistive µ-pic was strongly reduced. It was 10 4 - times smaller than that of conventional µ-pic at gain of 10 4. Using capacitive readout, the new operation mode, in which the two-dimensional signals can be read without HV 8

Figure 12: Spark probabilities of resistive µ-pic with both conventional and new operation under fast neutron irradiation. Figure 13: Electric field around cathode and pickup electrodes, simulated using Maxwell 3D. High electric field is found at edge of resistive cathode. Figure 14: Field strength along line joining both edges of cathode and pickup electrode. 9

coupling, was achieved. Although we need more improvements in the production process for stable operation, the resistive µ-pic will be one of the best solutions for non-floating structure MPGD. Acknowledgments We thank Hideo Uehara in Reytech-Inc. whose diligent efforts contributed to our proposal and improved the fabrication process. Also we thank the RD51 members, especially Rui de Oliveira for many fruitful suggestions, and we also would like to thank the KEK Detector Technology Project and the Japan MPGD Basic R&D Team for their suggestions and technical supports. This research was supported by Grant-in-Aid for Scientific Research (No.23340072, 24654067). References [1] A. Ochi, et al., Nucl. Instrm. Meth.A 471 (2001) 264 [2] A. Ochi et al., Nucl. Instr. Meth.A 478 (2002) 196 [3] H. Raether, Electron Avalanches and Breakdown in Gases. London, UK: Butterworth, 1964. [4] A. Bressan, et al., Nucl. Instr. Meth.A 424 (1999) 321 [5] S. Bachmann, et al., Nucl. Instr. Meth.A 479 (2002) 294 [6] R. Oliveira et al., IEEE Trans. on Nucl. Sci. Vol. 57, No. 6 (2010) [7] R. Oliveira et al., arxive:1101. 3727, (2011) [8] A Ochi, et al., Phys. Procedia 37 (2012) 554 [9] A. Ochi, et al., JINST7(2012) C05005 [10] ATLAS TGC Collaboration, Amplifier-Shaper-Discriminator ICs and ASD Boards, Production Readiness Review Report, 1999 10