User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Similar documents
Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

INFRARED THERMOMETER TM0819

InfraRed Thermometer with Laser Pointer

Introduction Cautions

INFRARED THERMOMETER Model : TM-959

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Noncontact Thermometer

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

Instruction Manual SEFRAM Thermal Camera

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

INSTRUCTION MANUAL Fax: (503)

IR 40. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 0~1000

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

GS-IR 8816 Series Infrared Thermometer

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

DIGITAL THERMOMETER WITH TRICOLOR LCD INSTRUCTION MANUAL

Infrared Thermometer Model CA879

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

INSTRUCTION MANUAL DTH Fax: (503)

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

Manual Dew point scanner PCE-DPT 1

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Infrared Hand-Held Thermometers

IR/Thermistor Pen. Instruction Manual

Operator's Manual. optris BR 400. Calibration source

INSTRUCTION MANUAL INF Fax: (503)

INFRARED TEMPERATURE SENSORS OPERATION AND SELECTION

Infrared Thermometer Model: and

PC100 Handheld ph/cond./tds/sal. Meter. Instruction Manual

Non contact temperature measurement

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

New! 2010 Model. Model No

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Infrared Temperature Calibration 101 Using the right tool means better work and more productivity

473-SHX Dew Point Mirror

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

IR-712 IR-712-EUR 12:1 Infrared Thermometer. IR-720 IR-720-EUR 20:1 Infrared Thermometer. IR-730 IR-730-EUR 30:1 Infrared Thermometer.

IT Series Infrared thermometer Using manual

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

High Accuracy High Speed in Your Process

473 Dew Point Hygrometer

Introduction to Infrared Thermometry

Rapid RH Portable ph Meter. User's Manual

Infrared Thermometer Calibration A Complete Guide

473 Dew Point Hygrometer

Infrared Hand-Held Thermometers

Emissivity and Remote Sensing

THERMOFOCUS, a technological innovation

Bante210 Benchtop ph Meter Instruction Manual

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Every object with a temperature above 0 Kelvin= -273,15 C emits

Dual laser + type K thermometer INFRARED THERMOMETER

Today s Weather 24 Hour Forecaster

63/66/68. Infrared Thermometers. Users Manual

MLCC APPLICATION GUIDE

PAR Meter Instruction Manual. Product # Product # Year Warranty

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Instruction Manual HI Refractometer for Invert Sugar Measurements

Chemistry MultiMeasure Sensor PS-2170

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

Emissivity: Understanding the difference between apparent and actual infrared temperatures

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

Sunlight and Temperature

6XMag-1 Magnifier User manual

RADIATION-METER TM-91/TM-92

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Red and Green Dot Sight FF26002 USER MANUAL

Emissivity and Remote Sensing

symphony Multisensor Probes

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Thermography Pocket Guide. Theory Practice Tips & Tricks

INF195 Infrared Thermometer

One-hand ph/temperature measuring instrument

OPERATING INSTRUCTIONS

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

566/568. Infrared Thermometers. Getting Started

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

Model 3024 Albedometer. User s Manual 1165 NATIONAL DRIVE SACRAMENTO, CALIFORNIA WWW. ALLWEATHERINC. COM

Thermal Imaging Best Practices: The Measuring Object. Page 2

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

DIGITAL THERMOMETER OPERATOR S MANUAL

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Infrared Thermosensor ES1C

1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration

Operating instructions Infrared temperature sensor TW20xx TW21xx

IR-712 IR-720 IR-730

MLCC APPLICATION GUIDE

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Designed to go where you work

Wireless Weather Station Instruction Manual

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

Transcription:

User Manual Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio with NIST-Traceable Calibration Model 20250-09 THE STANDARD IN PRECISION MEASUREMENT

Introduction The Digi-Sense Stick-Style Infrared Thermometer (Model 20250-09) with 8 to 1 distance-to-sight ratio offers fast response and high accuracy at the touch of a button. The built-in laser pointer increases target accuracy while the convenient push button and backlight LCD combine for ergonomic handheld operation. Unit features a dust- and water-resistant IP54 rating. Infrared thermometers can be used to safely measure the temperature of objects that are hard or improper to be measured by traditional contact thermometers. The instrument is fully tested and calibrated to NIST-traceable standards. Careful use of this meter will provide years of reliable service. Unpacking Check individual parts against the list of items below. If anything is missing or damaged, please contact your instrument supplier immediately. 1. Meter 2. One 9 V battery 3. User manual 4. NIST-traceable calibration report with data 2

Key Features 8:1 Distance-to-sight ratio 2% basic accuracy Precise noncontact IR measurements Laser sighting Fixed emissivity (0.95) User-selectable F or C temperature units Automatic data Hold Backlight LCD Automatic power-off to conserve battery life 3

Meter Description 1. Laser pointer beam 2. IR sensor 3. LCD 4. MEASURE button 5. Battery cover 6. F/ C switch 3 1 2 4 5 6 4

Display Layout 1. Emissivity value 2. Laser pointer indicator 3. Data HOLD icon 4. Low-battery indicator 5. F and C temperature icons 6. Temperature readout 1 2 3 4 6 5 5

How it Works Infrared thermometers measure the surface temperature of an object. The unit s optics sense emitted, reflected, and transmitted energy, which is collected and focused onto a detector. The unit s electronics translate the information into a temperature reading which is displayed on the unit. The laser is used for aiming purposes only. Field of View Make sure that the target is larger than the unit s spot size. The smaller the target, the closer you should be to it. When accuracy is critical, make sure the target is at least twice as large as the spot size. Distance and Spot Size As the distance (D) from the object increases, the spot size (S) of the area measured by the unit becomes larger. Locating a Hot Spot To find a hot spot, aim the thermometer outside the area of interest, then scan across with an up-and-down motion until you the locate the hot spot. 6

Emissivity Emissivity is a term used to describe the energyemitting characteristics of materials. Most (90% of typical applications) organic materials and painted or oxidized surfaces have an emissivity of 0.95 (fixed in the unit). Inaccurate readings will result from measuring shiny or polished metal surfaces. To compensate, cover the surface to be measured with black tape or flat black paint. Allow time for the tape to reach the same temperature as the material underneath it. Measure the temperature of the tape or painted surface. (Refer to table below.) Substance Thermal Thermal Substance emissivity emissivity Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Human skin 0.98 Cement 0.96 Lather 0.75 to 0.80 Sand 0.90 Charcoal (powder) 0.96 Earth 0.92 to 0.96 Lacquer 0.80 to 0.95 Water 0.92 to 0.96 Lacquer (matte) 0.97 Ice 0.96 to 0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85 to 0.95 Glass 0.90 to 0.95 Timber 0.90 Ceramic 0.90 to 0.94 Paper 0.70 to 0.94 Marble 0.94 Chromium oxides 0.81 Plaster 0.80 to 0.90 Copper oxides 0.78 Mortar 0.89 to 0.91 Iron oxides 0.78 to 0.82 Brick 0.93 to 0.96 Textiles 0.90 7

How it Works (continued) Good Measuring Practices Holding the meter by its handle, point the IR sensor toward the object whose temperature is to be measured. The meter automatically compensates for temperature deviations from ambient temperature. Keep in mind that it will take up to 30 minutes for the IR sensor to stabilize if going from ambient temperatures to a much higher (or lower) temperature measurement. Reminders The unit is not recommended for measuring shiny or polished metal surfaces (stainless steel, aluminum, etc.). See Emissivity on page 7. The unit cannot measure through transparent surfaces such as glass. It will measure the surface temperature of the glass instead. Steam, dust, smoke, etc. can prevent accurate measurement by obstructing the unit s optics. 8

Setup and Operation 1. To select the desired temperature units, open the battery cover and select F or C. 2. Hold the meter by its handle grip and point it toward the surface to be measured. 3. Push and hold the MEASURE button to turn the meter on and begin testing. The display will light if the battery is good. Replace the battery if the display does not light. 4. While measuring, the current temperature will appear on the LCD. 5. Release the MEASURE button to hold the reading. 6. Note: To conserve battery life, meter automatically powers down in 7 seconds once button is released. Specifications Temperature range 0 to 575 F ( 18 to 302 C) Resolution 0.1 F/C Accuracy ±3.6 F (2 C) or ±2% of reading Response time Less than 150 ms Emissivity Fixed at 0.95 Distance-to-sight ratio (field of view) D/S = Approximately 8:1 ratio (D = distance, S = spot) Laser Single Class 2 (II) laser Spectral range 8 to 14 µm Operating temperature 32 to 122 F (0 to 50 C) Storage temperature 14 to 140 F ( 10 to 60 C) Dimensions 7" x 1 3 4" x 1 1 2" (17.8 x 4.4 x 3.8 cm) Power One 9 V battery 9

Field of View The meter s field of view is 8:1, meaning that if the meter is 8 inches from the target, the diameter of the object under test must be at least 1 inch. Other distances are shown in the diagram above. Make sure that the target is larger than the meter s spot size. The smaller the target, the closer you should be to it. When accuracy is critical, make sure the target is at least twice as large as the spot size. Safety Use extreme caution when laser beam is turned on. Do not let the laser beam enter your eye, another person s eye or the eye of an animal. Be careful not to let the laser beam on a reflective surface strike your eye. Do not allow the laser light beam to impinge on any gas which can explode. 10

Maintenance, Recalibration, and Repair Cleaning and Storage The meter should be cleaned with a damp cloth and mild detergent when necessary. Do not use solvents or abrasives. Store the meter in an area with moderate temperature and humidity Battery Replacement If the battery power is insufficient, the Low-battery icon will appear on the LCD. Unscrew the battery cover and replace the 9 V battery. Rescrew the cover until it is securely closed. 11

Maintenance, Recalibration, and Repair (continued) It is recommended that Digi-Sense products are calibrated annually to ensure proper function and accurate measurements; however, your quality system or regulatory body may require more frequent calibrations. To schedule your recalibration, please contact InnoCal, an ISO 17025 calibration laboratory accredited by A2LA. Phone: 1-866-INNOCAL (1-866-466-6225) Fax: 1-847-327-2993 E-mail: sales@innocalsolutions.com Web: InnoCalSolutions.com For Product and Ordering Information, Contact: Toll-Free: 1-800-323-4340 Phone: 1-847-549-7600 Fax: 1-847-247-2929 ColeParmer.com/Digi-Sense Toll-Free: 1-800-358-5525 Phone: 1-847-327-2000 Fax: 1-847-327-2700 Davis.com/Digi-Sense 1065DGMAN_20250-09 Rev.1 Manual Part No. 00100-47