Stability Indicating HPTLC Method For Determination of Lornoxicam and Thiocolchicoside in the Pharmaceutical Dosage Form

Similar documents
SIMULTANEOUS ESTIMATION OF CILOSTAZOL AND ASPIRIN IN SYNTHETIC MIXTURE USING HPTLC METHOD

WORLD JOURNAL OF PHARMACEUTICAL AND MEDICAL RESEARCH

Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article

Development and Validation of HPTLC Method for the Estimation of Repaglinide in Bulk and Tablet Dosage Form

Pelagia Research Library

Available online Research Article

International Journal of Pharmaceutical Sciences and Drug Research 2016; 8(4):

Validated HPTLC Method for Simultaneous Quantitation of Aceclofenac, Paracetamol and Thiocolchicoside in Bulk drug and Pharmaceutical Formulation

TLC Densitometric Quantification of Vasicine, Vasicinone and Embelin from Adhatoda zeylanica leaves and Embelia ribes fruits

STABILITY INDICATING RP HPLC METHOD FOR ANALYSIS OF DORZOLAMIDE HCl IN THE BULK DRUG AND IT S PHARMACEUTICAL DOSAGE FORM

Scholars Research Library. Der Pharmacia Lettre, 2016, 8 (8): (

Department of Pharmaceutical Chemistry, Poona College of Pharmacy, Bharati Vidyapeeth University, Erandwane, Pune , India

Journal of Chemical and Pharmaceutical Research, 2012, 4(10): Research Article

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

DEVELOPMENT AND VALIDATION OF A STABILITY-INDICATING HPTLC METHOD FOR ANALYSIS OF ANTITUBERCULAR DRUGS

Development and Validation of Stability Indicating HPTLC Method for Estimation of Mifepristone

A Simple, Novel Validated Stability Indicating RP-HPLC method for estimation of Duloxetine HCl in Capsule Pharmaceutical Formulation

Vol-3, Issue-4, Suppl-1, Nov 2012 ISSN: Solanki et al PHARMA SCIENCE MONITOR

ESTIMATION OF LORNOXICAM IN TABLET DOSAGE FORM BY UV SPECTROPHOTOMETRIC METHOD

Development and Validation of HPTLC Method for Estimation of Azilsartan Medoxomil in Bulk and Pharmaceutical Dosage Forms

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

Development and Validation of Stability Indicating Assay Method of Etodolac by using UV-Visible Spectrophotometer

Impact factor: 3.958/ICV: 4.10 ISSN:

Department of Pharmaceutical Analysis, Hindu College of Pharmacy, Amaravathi Road, Guntur , India 2

Research Article Development and Validation of HPTLC Method for Simultaneous Estimation of Paracetamol and Pamabrom in Bulk and Synthetic Mixture

Scholars Research Library

METHOD DEVELOPMENT AND VALIDATION OF RALTEGRAVIR POTASSIUM AND RILPIVIRINE HCL BY HPLC AND HPTLC METHODS

Pelagia Research Library. Densitometric development and validation of mupirocin in ointment dosage form

Sci Pharm

Impact factor: 3.958/ICV: 4.10 ISSN:

International Journal of ChemTech Research CODEN( USA): IJCRGG ISSN : Vol.2, No.2, pp , April-June 2010

Scholars Research Library

J Pharm Sci Bioscientific Res (4): ISSN NO

Journal of Chemical and Pharmaceutical Research

Development and Validation of Stability Indicating RP-HPLC Method for the Determination of Anagrelide HCl in Pharmaceutical Formulation

Validated spectrophotometric determination of Fenofibrate in formulation

Received: ; Accepted:

Journal of Innovation in Pharmaceutical Sciences

Development and validation of HPTLC method for analysis of ursolic acid from methanol extract of mimosoups elengi L

STABILITY-INDICATING HPTLC METHOD FOR ESTIMATION OF GUAIFENESIN IN BULK AND IN PHARMACEUTICAL FORMULATION

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Validated First Order Derivative Spectroscopic Method for the determination of Stavudine in Bulk and Pharmaceutical Dosage Forms

Impact factor: 3.958/ICV: 4.10 ISSN:

International Journal of PharmTech Research CODEN (USA): IJPRIF, ISSN: , ISSN(Online): Vol.9, No.7, pp , 2016

DEVELOPMENT AND VALIDATION OF STABILITY INDICATING HPTLC METHOD FOR QUANTIFICATION OF LURASIDONE HCL A.R. Polawar and M.C. Damle *

Int. J. Pharm. Sci. Rev. Res., 30(2), January February 2015; Article No. 09, Pages: 63-68

Validated HPTLC Method for the Determination of Two Novel steroids in Bulk and Pressurized Metered-Dose Preparations

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form

Development of Validated Analytical Method of Mefenamic Acid in an Emulgel (Topical Formulation)

Research Article. Validated HPTLC method for simultaneous estimation of Aceclofenac and Pantoprazole in bulk and tablets dosage form

International Journal of Pharma and Bio Sciences

Zero And First Order Derivative Spectrophotometric Methods For Determination Of Dronedarone In Pharmaceutical Formulation

Development and validation of septrophotometricmethods for the estimation of rasagiline in tablet doage form

Journal of Pharma Research

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

Volume 6, Issue 2, January February 2011; Article-015

DEVELOPMENT AND VALIDATION OF SPECTROPHOTOMETRIC METHOD FOR SIMULTANEOUS DETERMINATION OF PREDNISOLONE ACETATE AND OFLOXACIN IN EYE-DROP

Available online on Journal of Advanced Drug Delivery 2014; 1(4); ISSN:

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF GABAPENTIN IN PURE AND PHARMACEUTICAL FORMULATIONS

Figure 1 Structure of Aceclofenac Figure 2 Structure of Pregabaline

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Pelagia Research Library

Dissolution study and method validation of alprazolam by high performance liquid chromatography method in pharmaceutical dosage form

J Pharm Sci Bioscientific Res (4): ISSN NO

Development and Validation of Stability Indicating HPTLC Method for Determination of Diacerein and Aceclofenac as Bulk Drug and in Tablet Dosage Form

Pharmacophore 2014, Vol. 5 (2), USA CODEN: PHARM7 ISSN Pharmacophore. (An International Research Journal)

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 9(1), 35-42

Analytical method development and validation of gabapentin in bulk and tablet dosage form by using UV spectroscopic method

Development and validation of HPTLC method for simultaneous estimation of canagliflozin and metformin hydrochloride in bulk and tablet dosage form

Praveen kumar.m 1 *, Sreeramulu.J 2. *Corres.author: Mobile no: India.

RP-HPLC Estimation of Trospium Chloride in Tablet Dosage Forms

Stability-indicating HPLC determination of tolterodine tartrate in pharmaceutical dosage form

Pelagia Research Library

Development and Validation of UV Spectrophotometric Estimation of Diclofenac Sodium Bulk and Tablet Dosage form using Area under Curve Method

Int. Res J Pharm. App Sci., 2012; 2(5): ISSN:

International Journal of Pharma and Bio Sciences V1(1)2010. HPLC method for analysis of Lercanidipine Hydrochloride in Tablets

Development And Validation Of Rp-Hplc Method For Determination Of Velpatasvir In Bulk

Stability Indicating RP-HPLC Method for Determination of Drotaverine HCL and Mefenamic Acid in Pure and Pharmaceutical Formulation

SIMULTANEOUS ESTIMATION OF MEFENAMIC ACID AND PARACETAMOL IN SUSPENSION FORM BY USING UPLC

Research Article. Simultaneous spectrophotometric estimation of Paracetamol and Aceclofenac by second order derivative method in combined dosage form

Chapter-4 EXPERIMENTAL WORK BY RP-HPLC

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

Simultaneous Estimation of Metolazone and Spironolactone in Combined Tablet Dosage Form BY UV Spectroscopy.

DEVELOPMENT AND VALIDATION OF HIGH PERFORMANCE THIN LAYER CHROMATOGRAPHIC METHOD FOR DETERMINATION OF REBAMIPIDE FROM ITS TABLET DOSAGE FORM

INTERNATIONAL RESEARCH JOURNAL OF PHARMACY

Development and Validation of Stability-Indicating RP-HPLC Method for Estimation of Atovaquone

DEVELOPMENT OF AN RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION AND FORCE DEGRADATION OF CEFIXIME AND MOXIFLOXACIN IN BULK AND PHARMACEUTICAL DOSAGE FORM

Research Article. UV Spectrophotometric Estimation of Alprazolam by second and third order derivative Methods in Bulk and Pharmaceutical Dosage Form

INTERNATIONAL RESEARCH JOURNAL OF PHARMACY

Simultaneous Determination of Ramipril, Hydrochlorothizide and Telmisartan by Spectrophotometry

Journal of Chemical and Pharmaceutical Research, 2014, 6(7): Research Article

Development of Ultraviolet Spectrophotometric Method for Analysis of Lornoxicam in Solid Dosage Forms

Development and validation of stability indicating reverse phase high performance liquid chromatography method for Timolol Maleate

Simultaneous Estimation Of Paracetamol And Pamabrom Inbulk Drugs And In Pharmaceutical Formulation By Spectrophotometry

Stability indicating RP-HPLC method for determination of azilsartan medoxomil in bulk and its dosage form

SIMPLE AND SENSITIVE VALIDATED REVERSE PHASE HPLC-UV METHOD FOR THE DETERMINATION OF LYMECYCLINE IN PHARMACEUTICAL DOSAGE FORMS

Available online Research Article

Stability Indicating RP-HPLC Method for Determination of Valsartan in Pure and Pharmaceutical Formulation

ORIENTAL JOURNAL OF CHEMISTRY An International Open Free Access, Peer Reviewed Research Journal.

Development and Validation of HPTLC Method for. Simultaneous Estimation of Sildenafil Citrate and Dapoxetine Hydrochloride in Combined Dosage Form;

Transcription:

Bulletin of Environment, Pharmacology and Life Sciences Bull. Env. Pharmacol. Life Sci., Vol 5 [10] September 2016: 48-54 2016 Academy for Environment and Life Sciences, India Online ISSN 2277-1808 Journal s URL:http://www.bepls.com CODEN: BEPLAD Global Impact Factor 0.533 Universal Impact Factor 0.9804 ORIGINAL ARTICLE OPEN ACCESS Stability Indicating HPTLC Method For Determination of Lornoxicam and Thiocolchicoside in the Pharmaceutical Dosage Form Atul R. Bendale* 1, R. P Singh 1, G. Vidyasagar 1 1 Suresh Gyan Vihar University, Mahal, Jagatpura, Jaipur-302 025, India *Corresponding Author E-mail: atulbendale123@gmail.com ABSTRACT A simple, sensitive and rapid high performance thin layer chromatographic (HPTLC) method has been developed and validated for quantitative determination of Lornoxicam (LOR) and Thiocolchicoside (THIO) in bulk and formulations. The chromatographic development was carried out on HPTLC plates precoated with Silica gel GF254 pre-coated on aluminum sheet (10 cm 10 cm) of 0.20 mm layer thickness as a stationary phase and Chloroform: Hexane: Methanol: Glacial Acetic Acid (2: 3.5: 2.5:0.2 v/v/v/v). Detection was carried out densitometrically at 286 nm (Absorbance mode). where Lornoxicam and Thiocolchicoside have significant absorbance. The retardation factor (Rf) values was found to be 0.17 ± 0.01 for LOR and 0.75 ± 0.01 for THIO. Peak Purity was found to be 0.998 and 0.997 respectuvely for LOR and THIO. The method was validated as per ICH guideline with respect to linearity, accuracy, precision, robustness etc. The method has demonstrated high sensitivity and specificity. The method was applied for Forced degradation studies also. The method is new, simple, economic and stability indicating for routine estimation of LOR and THIO in bulk, preformulation studies and pharmaceutical formulation to help the industries as well as researchers for their sensitive determination LOR and THIO rapidly at low cost in routine analysis. Key words: Lornoxicam,Thiocolchicoside, HPTLC,Stress degradation Received 22.06.2016 Revised 10.07.2016 Accepted 11.08.2016 INTRODUCTION Currently, HPTLC has become a usual analytical practice due to its advantages of consistency in quantitation of analytes at micro and nanogram levels and due to its cost efficiency. The main benefit of HPTLC is that a number of samples can be analyzed concurrently using a small amount of mobile phase unlike HPLC. This trim down the time and cost of analysis. As well it reduces revelation risks and appreciably reduces disposal problems of lethal organic effluents, in that way reducing possibilities of environment pollution. HPTLC also facilitates repeated detection (scanning) of the chromatogram with similar or dissimilar parameters. Simultaneous assay of several components in a multi component formulation is possible. The aim of the present study was to develop and validate a new, simple, accurate, specific and reproducible HPTLC method for determination of LOR and THIO. Lornoxicam is chemically ((3E)-6-chloro-3- [hydroxy(pyridin-2-ylamino)methylene]-2-methyl-2,3- dihydro-4h-thieno[2,3-e][1,2]thiazin-4-one1,1- dioxide, Lornoxicam (Fugure.1) is a non-steroidal antiinflammatory drug of the oxicam class with analgesic (pain relieving), anti-inflammatory and antipyretic properties. Thiocholchicoside is chemically N-[(7S)-3-(beta-D-glucopyranosy-loxy)-1,2-dimethoxy -10- (methylsulfanyl)- 9- oxo-5, 6, 7, 9-benzo [a] heptalen- 7-etrahydroyl] acetamide. Thiocolchicoside (Figure.2) is a muscle relaxant with anti-inflammatory and analgesic effects. It acts as a competitive GABA-A receptor antagonist and also inhibits glycine receptors with similar potency and nicotinic acetylcholine receptors to a much lesser extent [1-5]. The literature survey reveals that there are analytical methods available for determination of Lornoxicam and Thiocolchicoside from biological matrices, bulk drug and dosage forms by RP-HPLC/MS methods. The review of literature also reveal that no satisfactory HPTLC method available for determination of this combination. [6-13]. BEPLS Vol 5 [10] September 2016 48 P a g e 2016 AELS, INDIA

MATERIAL AND METHOD Pure Lornoxicam was kind gifts from Sun Pharmaceuticals, India and Thiocolchoside from Glenmark Pharmaceuticals, India. Commercial tablets (LORCHEK tab) containing Lornoxicam (LOR) and Thiocolchicoside (THIO) were used for the study. Chloroform, hexane, Methanol, Acetonitrile and Glacial Acetic Acid used were of analytical grade (E. Merck, Mumbai, India). Hydrochloric acid, sodium hydroxide, and hydrogen peroxide used for stress degradation studies were of analytical reagent grade, CDH Chemicals, Delhi, India. De-ionized water prepared using Milli-Q plus purification system, Millipore (Bradford, USA) was used throughout the study. All the other chemicals used were also of analytical grade (E. Merck, India). Instrumentation: HPTLC plates pre-coated with silica gel GF aluminium TLC plate, (10 cm x 10 cm) were from Merck. Densitometry was carried out with a CAMAG TLC Scanner III, with a win CATS 1.3.4 planar chromatography manager software. Samples were applied to the HPTLC plates using the spray-on technique of CAMAG LINOMAT V, and developed in a CAMAG 10 cm x 10 cm twin trough chambers. Preparation of solutions: The 100 mg of LOR were accurately weighed and transferred to 100 ml volumetric flask containing few ml (10 ml) of methanol. The flasks were sonicated for 2 minutes to dissolve the solids and volume was made up to the mark with methanol to obtain a standard solution containing 1000μg/ml LOR. Further 1ml of standard stock solution was transferred to 10 ml volumetric flask and solution was diluted up to the mark with methanol to get 100 ng/µl of LOR. The 100 mg of THIO were accurately weighed and transferred to separate 100 ml volumetric flask containing few ml (10 ml) of methanol. The flasks were sonicated for 2 minutes to dissolve the solids and volume was made up to the mark with methanol to obtain a standard solution containing 1000μg/ml THIO. Further 1ml of standard stock solution was transferred to 10 ml volumetric flask and solution was diluted up to the mark with methanol to get 100 ng/µl of THIO. Chromatographic conditions The plates were prewashed with methanol and activated at 110 C for 5 min prior to chromatography. Samples and standards were applied to the plate as 8mm band under a flow of N 2 gas, 11.6 mm apart, 15 mm from the bottom edge, and starting 15 mm from the edge of the HPTLC plate with Linomat V applicator. The constant sample-application rate was 100nL/s. The radiation source was a deuterium lamp emitting continuous UV radiation between 190 and 400nm. The scanning speed is 20mm/sec was employed. The Slit dimension was 6 0.45 millimetres. The Spotting parameter is a) Band width: 8 millimetre b) Syringe size: 100μl. Spotting of samples was done by using Hamilton microliter syringe. Method validation The developed method was validated as per the International Conference on Harmonization (ICH) guidelines with respect to linearity and range, specificity, precision, accuracy, limit of detection and limit of quantification. [14,15] System suitability System suitability test of the chromatography system was performed before each validation run. Five replicate injections of a system suitability standard preparation (200ng/band for LOR and 200ng/band for THIO) and one injection of a check standard were made. The parameters measured were retardation factor, peak purity and peak area LOR and THIO. Stress Study To evaluate the stability indicating properties of the developed HPTLC method, forced degradation studies were carried out in accordance to the ICH guidelines. The stress studies were carried out under the conditions of hydrolysis, photolysis, oxidation and dry heat, as defined in the ICH guideline Q1A (R2) (ICH, 2002) Stock solutions were prepared by accurately weighing 25 mg of THIO and 25 mg of LOR and transferring to three separate 25 ml volumetric flasks containing few ml of methanol. The flasks were swirled to dissolve the solids and diluted up to the mark with methanol. These stock solutions were used for forced degradation studies including Alkali hydrolysis, Acid hydrolysis, Neutral hydrolysis, Oxidative stress degradation, Dry heat degradation, Wet heat degradation and Photo degradation study. The results are indicated in Table 1. Linearity and Range Semi automatic spotter was used for spotting the sample on HPTLC plate. Appropriate aliquots of LOR working standard solution were taken in 10 ml volumetric flasks to obtain final concentration of 50 µg/ml of LOR. Appropriate aliquots of THIO working standard solution were taken in 10 ml volumetric flasks to obtain final concentration of 50µg/ml THIO. The solution having concentration of 50 µg/ml of LOR and 50 µg/ml THIO was filled in the syringe and under nitrogen stream, it was applied in form of BEPLS Vol 5 [10] September 2016 49 P a g e 2016 AELS, INDIA

band of desired concentration range for each of drug on a single plate having concentration of 50 to 500ng/band for LOR and 50 to 500ng/band for THIO. Triplicate 1 5µL portions of each standard solution were spotted as bands on a TLC plate. The plate was then developed using the previously described mobile phase and scanned under above established densitometry condition. The peak areas were plotted against the corresponding concentrations to obtain the calibration curves for each compound. The regression equation was found to be y = 17.02 x - 77.52 and correlation coefficient was found to be 0.997 for LOR. The regression equation was found to be y = 35.73 x - 27.35 and correlation coefficient was found to be 0.998 for THIO. The results are indicated in Table 2. Precision The repeatability of developed method was determined by analyzing 200ng/band LOR solution six times on the same day. The percentage RSD was found to be 0.032. The repeatability of developed method was determined by analyzing 200ng/band THIO solution six times on the same day. The percentage RSD was found to be 0.047. The results of repeatability data are shown in Table 5.5.7. The results of the intermediate precision (Intraday precision and Interday precision) experiments are shown in Table 5.5.8 for LOR. Replicate analyses of three different concentrations 50, 200 and 400 ng/band of LOR solutions showed good reproducibility. The percentages RSD of intraday and interday studies were found to be 0.023 0.035% and 0.031 0.15% respectively for LOR. The results of the intermediate precision (Intraday precision and Interday precision) experiments are shown in Table 5.5.9 for THIO. Replicate analyses of three different concentrations 50, 200 and 400 ng/band of THIO solutions showed good reproducibility. The percentages RSD of intraday and interday studies was found to be 0.025 0.04% and 0.028 0.434% respectively for THIO. Accuracy The recovery of the method was carried out by the standard addition to the preanalysed test sample at three different concentration levels 80%, 100% and 120%. Triplicate determinations were made at each concentration level. Known amount of standards of THIO (0, 160, 200 and 240 ng per band) and LOR (0, 80, 100 and 120 ng per band) were spiked to a pre-quantified sample (200 ng per spot) of THIO and (100 ng per spot) of LOR from tablet dosage form and the mixtures were analyzed by proposed HPTLC method. The percentage recovery of LOR and THIO was determined by measuring the peak areas and fitting these values into the regression equation of the calibration plot. The recoveries were found to be 100.21-100.64 and 99.04-100.21 for THIO and LOR, respectively. The values indicate that the method is accurate (table 3). Limit of detection and Limit of quantification The detection limits for LOR and THIO were found to be 0.65 ng/band and 1.8 ng/band, respectively, while quantitation limits were found to be 1.95 ng/band and 5.78 ng/band, respectively. The above data shows that a microgram quantity of both the drugs can be accurately and precisely determined. The values of LOD and LOQ of LOR and THIO respectively indicate the sensitivity of proposed method. Specificity and Selectivity The peak purity index and HPLC chromatogram showed peaks for both the drugs (LOR and THIO) without any interfering peak and the estimation of both the drugs were found to be satisfactory. Test solution is prepared by mixing of LOR and THIO with the tablet powder excipients. The peak purity of both drugs was assessed by comparing the respective spectra of standard drugs and samples at peak start, peak apex and peak end positions of the spot shown in figure 4 at peak start, peak apex and peak end positions of the spot. Specificity is proven by comparing the chromatogram of Diluent, standard solution and test preparation solution and by peak purity index to show that there was no any interference of excipients with the peak of LOR and THIO. Good correlation was obtained between standard and sample spectra of LOR and THIO. The comparative UV spectrum of standard and sample is found to be same. Also the results of comparison between peaks start, maximum, and end indicate the closeness in these positions between dosage forms and standards. The appearance of LOR and THIO spot at specific Rf different from its degrades indicates the specificity of the proposed method. Robustness Study The optimize densitometry condition of mobile phase is Chloroform: Hexane: Methanol: Glacial Acetic Acid (4: 3.5: 2.5:0.2 v/v/v/v), chamber saturation time is 30min and solvent migration distance is 80mm. The small changes chamber saturation time is 25 min and 35 min, and solvent migration distance is 70mm and 90mm, and mobile phase composition is evaluated. After small changes in this parameter effect on the peak area of LOR and THIO was determined. The low value of the RSD was found to indicating that the proposed method was robust, as small but deliberate changes in method parameters BEPLS Vol 5 [10] September 2016 50 P a g e 2016 AELS, INDIA

have no detrimental effect on the method performance. The low value of percentage relative standard deviation indicates that the method is robust. RESULT AND DISCUSSION The summary of method validation parameter and their result are shown in Table 4 indicating that the developed is validated as per ICH guidelines and result are within the ICH guidelines values. Figure 1. Chemical Structure of Lornoxicam Figure 2. Chemical Structure of Thiocolchicoside Figure 3. Typical Densitogram of Lornoxicam (LOR) and Thiocolchicoside (THIO) in marketed formulation BEPLS Vol 5 [10] September 2016 51 P a g e 2016 AELS, INDIA

Figure 4. Purity spectra of LOR and THIO Table 1: Stress Study by Proposed HPTLC Method % Degradation Stress condition Time THIO LOR Alkaline hydrolysis (1N NaOH) 2 hr 16.23 13.5 Acidic hydrolysis (0.1N HCl) 4 hr 12.23 7.5 Neutral Hydrolysis 4 hr 1.2 1.5 Oxidative Degradation (6% H2O2) 4 hr 19.23 12.5 Dry heat (70 C) 4 hr 1.23 9.5 Wet Heat (Boiling Water bath) 4 hr 0.93 6.75 Sun light 72 hr 1.03 1.75 UV radiation (254nm) 4hr 2.3 2.35 UV radiation (365nm) 4hr 1.6 1.15 Table 2: Statistical analysis data of calibration curve Parameters THIO LOR Linear Range 50-500 ng/band 50-500 ng/band Slope 35.73 17.02 Intercept 27.35 77.52 Regression Coefficient (r 2 ) 0.997 0.996 Standard deviation of slope 139.88 63.05 Standard deviation of intercept 287.24 85.76 LOD (ng/band) 0.65 1.8 LOQ (ng/band) 1.95 5.78 Table 3: Accuracy study Level Drug added (ng/band) Drug Recovered (ng/band) a % Drug Recovered ± SD For LOR 80 80 80.15 100.18 ± 0.95 100 100 100.21 100.21 ± 1.40 120 120 118.85 99.04 ± 1.62 For THIO 80 160 160.15 100.19 ± 1.98 100 200 201.31 100.65 ± 1.51 120 240 242.02 100.84 ± 1.41 a=average of Three determination BEPLS Vol 5 [10] September 2016 52 P a g e 2016 AELS, INDIA

Table 4: Summary of validation parameters Parameters LOR THIO Linear Range 50-500 ng/band 50-500 ng/band Regression Coefficient 0.997 0.998 Regression equation y = 17.02 x - 77.52 y = 35.73 x - 27.35 Recovery % 97.39 99.52 97.67 99.59 Repeatability (RSD, n=6) 0.032 0.047 Precision (RSD) Intra - day (n=3) Inter - day (n=3) Bendale et al 0.023 0.035 0.031-0.15 0.025 0.04 0.028 0.434 Limit of Detection (ng/spot) 1.8 0.65 Limit of Quantitation (ng/spot) 5.78 1.95 Robustness Robust Robust Solvent stability Stable for 48hrs Stable for 48hrs Specificity Specific Specific Peak Purity 0.998 0.997 CONCLUSION A quick, precise and accurate method based on normal-phase HPTLC has been developed for routine analysis of metformin Lornoxicam (LOR) and Thiocolchicoside (THIO) in fixed-dose combination tablets. The method was validated for linearity, precision, accuracy and specificity. Forced degradation studies were carried out and degradation product peaks were well resolved from drug peaks. It has the advantage over HPLC methods in general. It consumed less than 35mL of mobile phase per run (8 samples per plate), whereas HPLC methods would consume more than 50mL per runs of similar number of samples. If we consider the time from sample preparation to densitometric evolution for one plate, the new method took an average of 1 h, whereas HPLC methods would generally take more than 2 h for the same number of samples. It is cheap, quick and does not use chloroform, therefore suitable for routine analysis Lornoxicam (LOR) and Thiocolchicoside (THIO) in fixed-dose combination tablets. When compared with the reported HPLC method, the developed HPTLC method is both time and cost effective for the determination Lornoxicam (LOR) and Thiocolchicoside (THIO) mixtures. REFERENCES 1. The Merck Index, An Encyclopedia Of Chemical, Drug s and Biologicals, Maryadele J.O. Neil.Eds,14th edition, (2006). Merck Research Lab, Division of Merck and Co. Inc., Whitehouse Station, NJ: p.1603. 2. Martindale, The Extra Pharamcopoeia. (2005). Published by Direction of the Council Of Royal Pharmaceutical society of Great Britain. 34th ed, Vol.11. London Royal Pharmaceutical society; 1996. p1395 3. European Pharmacopoeia 6th ed. (2005). The directorate for the quality of medicines of the council of Europe; P.909 4. Indian Pharmacopoeia Vol.3 Ghazibad: (2007). Published by Ministry of Health and family welfare, Indian Pharmacopoeia commission;.p.193,246,681 5. Martindale. The complete drug reference. (2009). The extra Pharmacopoeia, published by direction of the council of royal pharmaceutical society of Great Britain. London Royal Pharmaceutical society 1996, 36th edition USA, P.773 6. Suganthi. A et al.,(2012). Stability Indicating HPLC Method for Simultaneous Determination of Thiocolchicoside and Lornoxicam. American Journal of PharmTech Research; 2(6), 369-379 7. Patil KR, Rane VP. (2009). Stability-Indicating LC Method for Analysis of Lornoxicam in the Dosage Form. Chromatographia;69: 1001-5. 8. Radhofer-Welte S, Dittrich P. (1998). Determination of the novel nonsteroidal anti-inflammatory drug lornoxicam and its main metabolite in plasma and synovial fluid. J Chromatogr B Biomed Sci Appl ;707:151-9. 9. Nemutlu E, Demircan S, Kir S. (2005). Determination of lornoxicam in pharmaceutical preparations by zero and first order derivative UV spectrophotometric methods. Pharmazie; 60:421-5. 10. Bhupendra S, Geetanjali S, Devendra NNS, Saumendu DR and Nishant G. (2011). Estimation of Lornoxicam in tablet dosage form by UV spectrophotometric method Int J Pharm Sci Res; 2(1): 116-20. 11. Kiran RP, Vipul PR, Jaiprakash NS, Devanand BS. (2009). Stability-Indicating LC method for Analysis of lornoxicam in the dosage form, Chromatogra. 69: 1001 05. 12. Shekhar MB, Dasharath MP, Amit PK, Patel CN. (2010). Validated RP-HPLC method for simultaneous estimation of lornoxicam and thiocolchicoside in solid dosage form. J Che Pharm Res; 2(2): 563-72. 13. El-Ragehy NA, Ellaithy MM, El-Ghobashy MA. (2003). Determination of thiocolchicoside in its binary mixtures (thiocolchicoside-glafenine and thiocolchicoside-floctafenine) by TLC-densitometry. Farmaco ;58:463-8. BEPLS Vol 5 [10] September 2016 53 P a g e 2016 AELS, INDIA

14. International Conference on Harmonization Guidance for Industry, In: (1994). Q2A Text on Validation of Analytical Methods, Switzerland, IFPMIA, pp. 1 4. 15. International Conference on Harmonization Guidance for Industry, In: (1996). Q2B Text on Validation of Analytical Methods, Switzerland, IFPMIA. pp. 1 8. CITATION OF THIS ARTICLE Atul R. Bendale, R. P Singh, G. Vidyasagar. Stability Indicating HPTLC Method For Determination of Lornoxicam and Thiocolchicoside in the Pharmaceutical Dosage Form. Bull. Env. Pharmacol. Life Sci., Vol 5 [10] September 2016: 48-54 BEPLS Vol 5 [10] September 2016 54 P a g e 2016 AELS, INDIA