arxiv: v1 [astro-ph.im] 13 Nov 2015

Similar documents
Cosmology Large Angular Scale Surveyor. Wednesday, September 25, 13

The Polarimeter for Observing Inflationary Cosmology at the Reionization Epoch (POINCARE)

POINCARE. Polarimeter for Observing Inflationary Cosmology at the Reionization Epoch

POLARBEAR-2 receiver system on the Simons Array telescopes for CMB polarization measurements

Optimizing the observing bandwidths for the CLASS HF detectors

Multi-chroic Feed-Horn Coupled TES Polarimeters

Measurements of Degree-Scale B-mode Polarization with the BICEP/Keck Experiments at South Pole

The international scenario Balloons, LiteBIRD, PIXIE, Millimetron

News from BICEP/Keck Array CMB telescopes

Polarization of the Cosmic Microwave Background: Are Those Guys Serious? Al Kogut Goddard Space Flight Center

The first light in the universe

Pixellated Planar Bolometer Imaging Arrays

Cosmic Inflation and Neutrino Masses at POLARBEAR CMB Polarization Experiment

QUIET-I and QUIET-II:

CMB Polarization Experiments: Status and Prospects. Kuo Assistant Professor of Physics Stanford University, SLAC

The Once and Future CMB

CMB studies with Planck

Detection of B-mode Polarization at Degree Scales using BICEP2. The BICEP2 Collaboration

SPIDER: A Balloon-Borne Polarimeter for Measuring Large Angular Scale CMB B-modes

M. Kenyon P.K. Day C.M. Bradford J.J. Bock H.G. Leduc

Science Objectives. Test Inflationary models, particle physics at the highest energies

Large Scale Polarization Explorer

QUaD and Development for Future CMB Experiments

Exploring the primordial Universe with QUBIC

MoBiKID Kinetic Inductance Detectors for up-coming B-mode satellite experiments

Michel Piat for the BRAIN collaboration

Power spectrum exercise

Measurements of CMB Polarization Anisotropy and Searches for Galaxy Clusters with Bolometer Arrays

PLANCK lately and beyond

Quasi-Optical Filters

Multiphysics Simulation of Polymer-Based Filters for Sub-Millimetre Space Optics

The ultimate measurement of the CMB temperature anisotropy field UNVEILING THE CMB SKY

A5682: Introduction to Cosmology Course Notes. 11. CMB Anisotropy

Primordial gravitational waves detected? Atsushi Taruya

The Millimeter-Wave Bolometric Interferometer (MBI) Greg Tucker Brown University

Probing the Dark Ages with 21 cm Absorption

Feedhorn-Coupled Transition-Edge Superconducting Bolometer Arrays for Cosmic Microwave Background Polarimetry

The Einstein Polarization Interferometer for Cosmology (EPIC)

Revisiting the ALMA Band 1 Optics Design P. Zorzi 1, D. Henke 2, S. Claude 2, P. Mena 1, L. Bronfman 3, and J. May 3

The cosmic background radiation II: The WMAP results. Alexander Schmah

IMPLEMENTATION OF A QUASI-OPTICAL FREE-SPACE S-PARAMETERS MEASUREMENT SYSTEM

arxiv: v1 [astro-ph.im] 11 Jul 2018

The QUIET Experiment. Bruce Winstein The University of Chicago Inflation Probe Systematics Workshop Annapolis, MD July 28-30

Estimation of the Cosmic Microwave Background Radiation

Toward an Understanding of Foregrounds in the BICEP2 Region

Really, really, what universe do we live in?

Transition Edge Sensor Thermometry for On-chip Materials Characterization

arxiv: v1 [astro-ph.im] 5 Jul 2017

Sensitivity of surface resistance measurement of HTS thin films by cavity resonator, dielectric resonator and microstrip line resonator

Observational Cosmology

Variation in the cosmic baryon fraction and the CMB

WMAP 9-Year Results and Cosmological Implications: The Final Results

Lorenzo Moncelsi. SPIDER Probing The Dawn Of Time From Above The Clouds

CMB Polarization and Cosmology

arxiv: v1 [physics.ins-det] 13 Nov 2017

arxiv: v2 [astro-ph.im] 23 Jul 2018

Simulating Cosmic Microwave Background Fluctuations

Effective testing for wafer reject minimization by terahertz analysis and sub-surface imaging

Characterization of a high-performance Ti/Au TES microcalorimeter with a central Cu absorber

Cosmic Microwave Background Introduction

Short course: 101 level introductory course to provide a foundation for everyone coming to the workshop to understand the field.

Planck Mission and Technology

THE PLANCK MISSION The most accurate measurement of the oldest electromagnetic radiation in the Universe

The CMB sky observed at 43 and 95 GHz with QUIET

Future experiments from the Moon dedicated to the study of the Cosmic Microwave Background

Electro-Optical System. Analysis and Design. A Radiometry Perspective. Cornelius J. Willers SPIE PRESS. Bellingham, Washington USA

Supplementary Figure 1: SAW transducer equivalent circuit

Ir TES electron-phonon thermal conductance and single photon detection

Calibrating the Thermal Camera

Anisotropy in the CMB

Precise measurement of CMB polarisation from Dome-C: the BRAIN and CLOVER experiments

Priming the BICEP. Wayne Hu Chicago, March BB

Instrumental Systematics on Lensing Reconstruction and primordial CMB B-mode Diagnostics. Speaker: Meng Su. Harvard University

Physics of CMB Polarization and Its Measurement

A5682: Introduction to Cosmology Course Notes. 11. CMB Anisotropy

The Einstein Polarization Interferometer for Cosmology (EPIC)

Microwave Background Polarization: Theoretical Perspectives

A TES Bolometer for THz FT-Spectroscopy

Galaxies 626. Lecture 3: From the CMBR to the first star

TES for CMB. Flavio Gatti Università e INFN, Genova

Planck 2014 The Microwave Sky in Temperature and Polarisation Ferrara, 1 5 December The Planck mission

Ringing in the New Cosmology

The CMB and Neutrinos

arxiv: v1 [astro-ph.im] 17 Sep 2015

Constraining the topology of the Universe using CMB maps

Performance of horn-coupled transition edge sensors for L- and S-band optical detection on the SAFARI instrument

Lecture 03. The Cosmic Microwave Background

arxiv: v1 [astro-ph.im] 7 Jan 2016

PICO - Probe of Inflation and Cosmic Origins

MODELING OF AN ECR SOURCE FOR MATERIALS PROCESSING USING A TWO DIMENSIONAL HYBRID PLASMA EQUIPMENT MODEL. Ron L. Kinder and Mark J.

Theoretical study of two-element array of equilateral triangular patch microstrip antenna on ferrite substrate

Observational evidence for Dark energy

by applying two pairs of confocal cylindrical lenses

System design of 60K Stirling-type co-axial pulse tube coolers for HTS RF filters

SPICA/SAFARI (SPace Infrared telescope for Cosmology and Astrophysics)

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Astronomy 203 practice final examination

Multicolor mm/submm TES Bolometer Camera development for ASTE. Tai Oshima (NRO/NAOJ)

TES Bolometer Array for the APEX-SZ Camera

Semiconductor Disk Laser on Microchannel Cooler

Transcription:

Journal of Low Temperature Physics manuscript No. (will be inserted by the editor) arxiv:1511.04414v1 [astro-ph.im] 13 Nov 2015 D.T. Chuss A. Ali M. Amiri J. Appel C.L. Bennett F. Colazo K.L. Denis R. Dünner T. Essinger-Hileman J. Eimer P. Fluxa D. Gothe M. Halpern K. Harrington G. Hilton G. Hinshaw J. Hubmayr J. Iuliano T.A. Marriage N. Miller S.H. Moseley G. Mumby M. Petroff C. Reintsema K. Rostem K. U-Yen D. Watts E. Wagner E.J. Wollack Z. Xu L. Zeng Cosmology Large Angular Scale Surveyor (CLASS) Focal Plane Development the date of receipt and acceptance should be inserted later Abstract The Cosmology Large Angular Scale Surveyor (CLASS) will measure the polarization of the Cosmic Microwave Background to search for and characterize the polarized signature of inflation. CLASS will operate from the Atacama Desert and observe 70% of the sky. A variable-delay polarization modulator (VPM) modulates the polarization at 10 Hz to suppress the 1/f noise of the atmosphere and enable the measurement of the large angular scale polarization modes. The measurement of the inflationary signal across angular scales that span both the recombination and reionization features allows a test of the predicted shape of the polarized angular power spectra in addition to a measurement of the energy scale of inflation. CLASS is an array of telescopes covering frequencies of 38, 93, 148, and 217 GHz. These frequencies straddle the foreground minimum and thus allow the extraction of foregrounds from the primordial signal. Each focal plane contains feedhorn-coupled transition-edge sensors that simultaneously detect two orthogonal linear polarizations. The use of single-crystal silicon as the dielectric for the on-chip transmission lines enables both high efficiency and uniformity in fabrication. Integrated band definition has been implemented that both controls the bandpass of the single mode transmission on the chip and prevents stray light from coupling to the detectors. Keywords CMB, TES Department of Physics, Villanova University Villanova, PA 19085, USA Tel.:610-519-4884 Fax: E-mail: david.chuss@villanova.edu

2 1 Introduction Measurement of the polarization of the cosmic microwave background (CMB) provides a means to test and constrain inflation. Inflation provides a mechanism for producing the observed flatness of the universe, near uniformity of the CMB, and the nearly scale invariant scalar perturbations in the density of the early universe. In addition to these density perturbations, inflation predicts a spectrum of gravitational waves that will polarize the CMB. Whereas polarization that arises from the density fluctuations will contain only a curl-free component ( E-modes ), the inflationary gravitational waves will contain both E-modes and a divergence free set of B-modes. Thus, a search for CMB B-mode polarization provides a well-posed test of inflationary physics. In addition to testing inflation, CLASS s measurement of the E-mode polarization to unprecedented precision will provide significant improvements in the measurement of the optical depth to reionization. These measurements will distinguish between reionization scenarios and, in conjunction with data from higher resolution instruments, will help constrain neutrino masses. The challenges in measuring the CMB polarization in search of inflation stem from the small expected amplitude of the signal and the fact that it needs to be measured in the presence of an unpolarized signal that is 8-9 orders of magnitude larger than the desired signal. These two conditions push instrument designs to minimize systematic errors, but also maximize sensitivity. The latter criterion motivates focal planes that have sufficient sensitivity to make the measurement with feasible integrations times. There are two features that are important here. First, the detectors should be sensitive enough such that photon noise dominates over detector noise. For single-mode sensors, throughput is proportional to the number of sensors in the focal plane; however, the number of detectors does not by itself constitute an effective metric for sensitivity. The efficiency of the sensor architecture along with that of the instrument are also important in determining array sensitivity. In this work, we describe the CLASS focal plane technology, focusing on the completed 38 GHz array. 2 CLASS The Cosmology Large Angular Scale Surveyor (CLASS) is a telescope array designed to measure the CMB at a unique combination of angular scales and frequencies. A more complete summary of the instrument is given in Essinger- Hileman et al. (2014), 1 but the main features will be summarized here. The four focal planes consist of the following. One focal plane with 36 detector pairs operating at 38 GHz, two focal planes with 259 detector pairs each operating at 93 GHz, and a dual-band telescope with 1000 detector pairs at each of 148 and 217 GHz. The NEQ per single polarization mode is expected to be 208 µk s for the 38 GHz receiver that is described here. The combined efficiency of the optics and the detector is 68%. CLASS is located at an altitude of 5200 feet in the Atacama Desert. The CLASS survey will cover 70% of the sky in order to access multipoles (l < 10) associated with the reionization feature of the predicted B-mode spectrum. The large-scale survey is enabled by front-end polarization modulation provided by

3 Radiation from Telescope Probe Antennas Band-Defining Filter microwave circuitry for OMT, power combiner, bolometer, w/ read-out lead to signal MUX chip. mass reduction hollow OMT Magic Tee Si layers TES (H) TES (V) Thermal Blocking Filter /4 wave backshort Fig. 1 Left The schematic of the detector concept is shown. Right The layout of the 40 GHz detector chip is shown. (Color figure online.) a variable-delay polarization modulator 2,3 for each of the four telescopes. Rapid ( 10 Hz) polarization switching is used to suppress the long term (1/ f ) fluctuations of the atmospheric emission. Secondary modulations such as constant elevation scanning and periodic rotations about the boresight will be used to decouple instrumental effects and fill in the parameter space for the survey. CLASS will have sensitivity below a tensor-to-scalar ratio, r = 0.01. Techniques foreground removal using the 4 CLASS bands 4 and mitigation of systematic effects associated with using a VPM to recover the large scale polarization modes 5 have been validated through simulations and have been found to be effective for the target r. 3 Detector Concept The detector concept is shown in Figure 1. 6,3,11 Light from the telescope is incident on an array of feedhorns. To make fabrication less expensive, and thus improve the scalability of these arrays, the array is implemented using monotonic smooth-walled feedhorns 7 that exhibit good beam symmetry and a measured cross-polarization response of better than -30 db across each of the 38 and 93 GHz bands out to the edge of the pupil stop. At the base of each feedhorn is a planar orthomode transducer (OMT) fabricated in niobium microcircuitry with a monocrystalline silicon dielectric. The monocrystalline silicon provides several advantages. First, the dielectric loss in the silicon is negligible, resulting in high efficiency for the sensor. Second, the electrical permittivity of the material is highly uniform, reducing the variability of the electrical properties of the circuit between detectors. Third, the acoustic properties of the material are uniform, allowing precision control over thermal conductance of the devices. The interface between the metallic feedhorn and the silicon wafer is controlled by implementing a photonic choke, 8 which consists of an array of square pillars that prevent leakage at this interface without a conductive connection. The photonic choke is implemented by direct machining the metallic part of the interface

4 TES Fig. 2 Left The 38 GHz detector chip is shown. Upper Right The fully integrated single 38 GHz dual-polarization sensor is shown. The black box is the backshort cap that completes the OMT by maximizing the electric fields in the vicinity of the antennas as well as blocks stray light from coupling to the TESes. Lower Right A photo of one of the TESes is shown. Thermal conductance of the detector is set by a ballistic leg connecting the TES island to the substrate, visible at the bottom of the TES island (Color figure online.) in the 38 GHz array; in the 93 GHz array, the choke is etched into the top layer of the wafer assembly. The OMT independently couples two orthogonal polarization modes into independent microstrip circuits. Unwanted modes are rejected by the OMT design, which consists of a magic-tee that is used to difference the signal from opposite antennas. 9,10 The desired (symmetric) signal for each antenna pair is coupled to the microstrip line for that polarization. The asymmetric modes are resistively terminated at the sum port of the magic-tee. Once the signal for each polarization is in the microstrip, a series of banddefining and thermal blocking filters limit the response of the sensor to the desired passband. For the case of the 38 GHz focal plane, this is 33-43 GHz. For the 93 GHz focal planes, the bandpass is 77-108 GHz. After filtering, the signal is terminated in a resistor that is thermally coupled to a transition-edge sensor (TES) that has a target transition temperature of T c =150 mk. The circuit is shown in the left panel of Figure 2. The TES is shown in the lower right panel of the same figure. The microwaves are transmitted to the absorber by the two straight legs near the top of the photo. The curved legs on either side are the TES bias leads. These long legs contribute very little to the thermal conductance of the TES to the frame because their side walls are rough. The thermal conductance is primarily set by the ballistic phonon conduction in the short leg near the bottom of the image. 15 In the interest of minimizing systematic errors, stray light control is essential. As mentioned above, out-of-band radiation that enters the detector via the microstrip lines is blocked by the thermal blocking filters (and by the waveguide cutoff in the feedhorn on the low frequency side). Direct stray light coupling to the TES is minimized by incorporating radiation shielding into the backshort cap (see Fig 2, top right). Fabrication has been described in previous work. 12,13,14 4 CLASS Focal Planes Each CLASS focal plane is housed in a separate cryostat having lenses that are cooled to 4 K and 1 K via a pulsed tube cooler. The focal plane is cooled to 100

5 Fig. 3 Left The CLASS 38 GHz focal plane is shown from the feedhorn side. Right The back of the focal plane consists of 36 dual polarization individual detectors that are accurately mounted to a single plate. (Color figure online.) 20 Number of bolometers 15 10 5 =4.2 mk 15 10 5 =0.7 nw/k 4 15 10 5 =0.7 pw 0 15 10 5 0 5 10 15 0 2.0 1.5 1.0 0.5 0.0 0.5 1.0 1.5 2.0 0 2 1 0 1 2 T c (mk) (nw/k 4 ) P sat (pw) Fig. 4 The intra-wafer spread of the critical temperature (T c ), thermal conuctance, κ, and saturation power (P sat ) are shown for the 38 GHz focal plane. mk via a continuous dilution refrigerator. A 4 K stop is located near the window of the cryostat. The pupil is re-imaged by warm reflective optics onto the 60 cm diameter VPM, which is located at the front of the optics. 17 The CLASS 38 GHz focal plane is complete and shown in Figure 3. The focal plane consists of 36 detector pairs, each containing a feedhorn-coupled TES for each polarization. Because of the large size required at this frequency, each detector pair is individually fabricated, integrated with its backshort cap, and mounted to the focal plane. This process has resulted in 98% of the TESes operational. The detector noise at the modulation frequency has been measured to be 10-15 awhz 1/2 for all sensors. The measured efficiency for the detector is 90%, and using a waveguide calibration source, 16 we have verified no appreciable out-ofband leaks up to 500 GHz. Histograms of the deviation from the wafer average for achieved T c, thermal conductivity (κ), and saturation power (P sat ) are shown in Figure 4. These are similar to those previously reported, 18 but have been updated to include the entire 38 GHz CLASS focal plane. The 38 GHz focal plane is currently integrated into the CLASS cryostat and will be deployed to the Atacama in late 2015. Additional receivers will follow. For frequencies higher than 38 GHz, focal planes consist of tilable modules. Photographs of a 93 GHz module and a 93 GHz integrated wafer are shown in Figure 5.

6 Fig. 5 Left A CLASS 93 GHz detector module is shown. Right A fully integrated 37-element CLASS 93 GHz wafer is shown. The pattern of squares visible on the surface are the photonic choke pillars (Color figure online.) Acknowledgements Support for CLASS has been provided by the National Science Foundation through grant numbers 0959349 and 1429236. The NASA ROSES/APRA program has provided funding for the development of the detectors. K. Harrington was supported by a NASA Space Technology Research Fellowship (NNX14AM49H). D Watts is funded by the Maryland Space Grant Consortium. References 1. T. Essinger-Hileman et al., Proc. SPIE, 9153:1 (2014), DOI: 10.1117/12.2056701 2. D. T. Chuss, E. J.Wollack, S. H.Moseley, and G.Novak Applied Optics, 45:5107-5117, (2006), DOI:10.1117/12.671927 3. D. T. Chuss et al. J. Low Temp. Phys., 167:923 928 (2012), DOI:10.1007/s10909-011-0433-2 4. D. Watts et al. Submitted to Ap. J., arxiv:1508:00017, (2015). 5. N. Miller et al., Submitted to Ap. J., arxiv:1509.04628, (2015). 6. T. Stevenson et al., J. Low Temp. Phys, 151:471 476 (2008), DOI: 10.1007/s10909-007-9679-0 7. L. Zeng et al. IEEE TAP, 58:1383 1387, 2010, DOI: 10.1109/TAP.2010.2041318. 8. E.J. Wollack, K.U-Yen, and D.T. Chuss, Microwave Symposium Digest (MTT), IEEE MTT-S:177 180, (2010). 9. K. U-Yen et al., In Microwave Symposium, 2007. IEEE/MTT-S International: 37 40, (2007). 10. K. U-Yen et al., IEEE Trans. Microwave Theory Tech, 56(1):172 177, (2008). 11. K. Rostem et al., Proc. SPIE, 9153:0, (2014), DOI: 10.1117/12.2057266 12. K. L. Denis et al., AIP Conference Series, 1185: 371-374, (2009), DOI: 10.1063/1.3292355 13. E.J. Crowe et al., Applied Superconductivity, IEEE Transactions on, 23(3):2500505 2500505, (2014). 14. K.L. Denis et al. J. Low Temp. Phys., submitted, (2015). 15. K. Rostem et al. J. Appl. Phys., 115:124508, (2014), DOI:10.1063/1.4869737. 16. K. Rostem et al., Rev. Sci. Inst, 84:044701, (2013), DOI:10.1063/1.4795556.

17. J. R. Eimer et al. Proc. SPIE, 845220:15, (2012), DOI: 10.1117/12.925464 18. J. W. Appel et al. In SPIE Conference Series, 9153:1, (2014), DOI: 10.1117/12.2056530 7