Application Note 059 Direct Desorption of Car Trim Materials for VOC and SVOC Analysis in Accordance with VDA Method 278

Similar documents
Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Application Note 032

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Thermal Desorption Technical Support

Application Note. Application Note 081 Innovative Cryogen-Free Ambient Air Monitoring in Compliance with US EPA Method TO-15. Abstract.

Enhanced odour profiling of strawberries using TD GC TOF MS

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Thermal Desorption Technical Support. Note 56: TD-GC/MS analysis of vapour-phase organic compounds for materials emissions testing.

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Magnitudes of Back Diffusion During Long-Term Diffusive Sampling of Volatile Organic Compounds Using Carbotrap and Chromosorb 106

Thermal Desorption Technical Support

Analysis of Extractable and Leachable (E&L) Compounds Using a Low-Energy EI-Capable High Resolution Accurate Mass GC/Q-TOF

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

TDTS 16 Round-the-clock, on-line and cryogen-free monitoring of hydrocarbons from acetylene to trimethylbenzene in ambient air

Ultra-Inert chemistry for Trace Level Analysis

Industrial Applications with a New Polyethylene Glycol-Based GC Column

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Low-Level Sulfur Compounds in Beer by Purge and Trap with a Pulsed Flame Photometric Detector (PFPD)

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

INNOVATIVE PRODUCTS, SUPERIOR SUPPORT. Presenter: Anne Jurek, Senior Applications Chemist, EST Analytical

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

Series 2. Continuous monitoring of trace chemical vapours

SURVEY OF CHEMICALS EMISSION FACTORS FROM BUILDING MATERIALS FOR INTERIORS

Understanding Gas Chromatography

Characterising Volatile Organic Compounds from Sewer Emissions by Thermal Desorption coupled with Gas- Chromatography-Mass Spectrometry

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

VOC TEST REPORT AgBB

Automated Characterization of Compounds in Fire Debris Samples

VOC EMISSION TEST REPORT ISO 16000

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Copyright 2009 PerkinElmer LAS and CARO Analytical Services, Inc.

VOC TEST REPORT EMICODE

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

TDTS. Keywords. Introduction. TD Operation; Calibration; Impedance; Discrimination

VOC TEST REPORT M1. 6 April Regulation or protocol Conclusion Version of regulation or protocol

VOC EMISSION TEST REPORT BREEAM NOR

Test Report. Muovihaka Oy. Product Emissions in accordance with the Swedish Building Material Assessment Ultima graphite.

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Agilent J&W PoraBOND Q PT Analyzes Oxygenates in Mixed C4 Hydrocarbon Streams by GC/FID and GC/MSD

Evaluation of a New Analytical Trap for Gasoline Range Organics Analysis

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

A New PEG GC Column with Improved Inertness Reliability and Column Lifetime Agilent J&W DB-WAX Ultra Inert Polyethylene Glycol Column

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

A Generic Method for the Analysis of Residual Solvents in Pharmaceuticals Using Static Headspace-GC-FID/MS

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

Optimization of 1,4-Dioxane and Ethanol Detection Using USEPA Method 8260 Application Note

VOC TEST REPORT EMICODE

Headspace Technology for GC and GC/MS: Features, benefits & applications

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Intertek Environmental VOC Emissions

Author. Abstract. Introduction

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

EPA TO-17 Volatile Organic Compounds

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Test Report- VOC emission regulations in Europe

Test Report- VOC emission regulations in Europe

TO-17 Extending the Hydrocarbon Range above Naphthalene for Soil Vapor and Air Samples Using Automated

Test Report- VOC emission regulations in Europe

UltiMetal Plus Advanced Chemistry for Stainless Steel Surface Deactivation

Application Note. Abstract. Authors. Introduction

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

VOC TEST REPORT M1. 16 August Regulation or protocol Conclusion Version of regulation or protocol

Maximizing Sample Throughput In Purge And Trap Analysis

Thermal Desorption Applications Guide:

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Application. Gas Chromatography February Introduction

VOC TEST REPORT M1. 23 October Regulation or protocol Conclusion Version of regulation or protocol

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

Water Injections in GC - Does Water Cause Bleed?

Agilent UltiMetal Plus Stainless Steel Deactivation for Tubing, Connectors, and Fittings

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

Detection of Chemical Warfare Agents by Transportable GC/MS

Analytical Trap Comparison for USEPA Method 8260C

AIR. Ambient, Indoor, Workplace Air and Stack Emissions Proficiency Testing Scheme. Sample Preparation Instructions Round 1

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Analysis of BTEX in Natural Water with SPME

Test report No. MAIC Chamber emission test of a leather sample.

VOC TEST REPORT Indoor Air Comfort

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Screening for 171 Volatile Organic Air Pollutants Using GC/MS with Deconvolution Reporting Software and a New Indoor Air Toxics Library Application

M1 Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Test Report. Glava AS. Emission test of Ecophon Venus according to M1 classification. October / November Smedeskovvej 38, DK-8464 Galten

Solid Phase Micro Extraction of Flavor Compounds in Beer

Chemistry Gas Chromatography: Separation of Volatile Organics

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

Transcription:

Application Note Direct Desorption of Car Trim Materials for VOC and SVOC Analysis in Accordance with VDA Method Application Note Abstract In this application note, we demonstrate the suitability of Markes TD- automated thermal desorption system for performing the analysis of volatile and semivolatile organic compounds (VOCs and SVOCs) in three types of automotive trim materials (polypropylene, artificial leather, and foam) in accordance with the German Association of the Automotive Industry (VDA) Method. Introduction The German Association of the Automotive Industry (VDA) consists of automobile manufacturers, their development partners, and their suppliers. The VDA promotes German motor trade interest by participating in the development of economic, transport, and environmental policy, and setting appropriate technical standards. Given the international nature of the automotive industry, VDA actions have an impact on subsidiaries and suppliers based in other countries. Concern is growing worldwide over the quality of air in vehicle cabins. Many people, including vulnerable groups such as children and the elderly, spend a significant proportion of their time in cars and are at risk of being exposed to odorous or toxic organic chemicals that may be emitted from car interior trim components. The levels of volatile and semivolatile organic compounds (VOCs and SVOCs) found in car cabin air can be several times higher than normal ambient air levels (indoor or outdoor) see Application note.

In response to (S)VOC concerns, the VDA developed a series of methods for assessing (S)VOC emissions from car trim components such as upholstery, carpets, glues, sealing compounds, plastics, foam, leather, coatings, and paint. One such test, known as VDA Method, requires the assessment of two values: VOC value: The sum of the VOCs and SVOCs up to n-c emitted under one set of specified analytical conditions. FOG value: The sum of the SVOCs (from n-c to n-c ) emitted under a different set of specified test conditions. VDA Method specifies direct thermal desorption (TD) (using heat and a flow of inert gas) of small samples of relatively homogeneous materials used in car trim components (leather, plastic, and so forth). VOCs and SVOCs are extracted from the sample into the gas stream and are refocused onto a secondary focusing trap prior to injection into a GC/MS or GC/FID system for analysis. VDA Method comprises two extraction stages: VOC analysis: This involves desorbing the sample at C for minutes to extract compounds with volatilities up to n-c. This is followed by semiquantitative analysis of each compound as micrograms of toluene equivalents per gram of sample. FOG analysis: This involves desorbing the sample at C for minutes to extract compounds ranging in volatility from n-c to n-c. This is followed by semiquantitative analysis of each compound as micrograms of n-hexadecane equivalents per gram of sample. Experimental Samples Polypropylene: ± mg Leather: ± mg Foam: ± mg All samples were weighed directly into an empty unfritted glass sample tube with restrictions at either mm or mm, depending on the sample material. Step : Determination of VOC value Parameter Instrument: Value Desorption temperature: C Desorption time: Focusing trap: TD- (Markes International) minutes Focusing trap low: C Focusing trap high: C Focusing trap hold: General-purpose hydrophobic (Tenax TA graphitised carbon black) minutes Flow path temperature: C Trap flow: Split flow (inlet and outlet): Carrier gas flow: Temperature program: ml/min ml/min Mass range: m/z - Auxiliary temperature: C. ml/min (constant flow) C ( minutes), then C/min to C, then C/min to C, then C/min to C ( minutes) Step : Determination of FOG value Parameter Instrument: Value Desorption temperature: C Desorption time: Focusing trap: TD- (Markes International) minutes Focusing trap low C Focusing trap high: C Focusing trap hold: General-purpose hydrophobic (Tenax TA graphitised carbon black) minutes Flow path temperature: C Trap flow: Split flow (inlet and outlet): Temperature program: ml/min ml/min Mass range: m/z - Auxiliary temperature: C C ( minutes), then C/min to C, then C/min to C ( minutes) A calibration solution of toluene and hexadecane in methanol at a concentration of ng/µl was introduced into the sampling end of a sample tube packed with mg of Tenax TA sorbent in a stream of pure inert gas.

Results and Discussion VOC and FOG analyses Results of the VOC and FOG analyses for samples of polypropylene, artificial leather, and foam, using Markes TD automated thermal desorber, are presented in Figures -. System inertness and recovery of active compounds To demonstrate system suitability (inertness) for polar species, an activity test mix containing compounds was prepared at a concentration of. µg/µl ±. µg/µl (Table ). Table. Activity test mix and associated component concentration levels. Concentration (μg/µl) Benzene. n-heptane. Toluene. n-octane. p-xylene. o-xylene. n-nonane. n-decane. -Ethylhexan--ol. n-undecane.,-dimethylphenol. n-dodecane. n-tridecane. n-tetradecane. Dicyclohexylamine. n-pentadecane. n-hexadecane. Bis(-ethylhexyl) adipate. Amount. -Methylpropene.. Acetone.. -Methylhexane..,-Dimethylheptane..,-Dimethylhept--ene.. -Methyloctane.. Tris(-butoxyethyl) phosphate..,-dimethyldecane.. -Methylundecane.. Dodecane..,,-Trimethyldecane.. -Ethyl--methyloctane.. Tetradecane.. Pentadecane.. Hexadecane.. Heptadecane.. Octadecane.. Eicosane.. Heneicosane.. Pentacosane. Figure. VOC analysis of a. mg sample of polypropylene.

.................... Amount -Methylpropene. Acetone.,-Dimethylhept--ene. Decane.,-Dimethyldecane. -Methylundecane. Dodecane.,,-Trimethyldecane. -Ethyl--methyloctane. Tetradecane. Pentadecane.,,-Trimethyldodecane. Hexadecane. Heptadecane. Octadecane. Eicosane. Heneicosane. Docosane. Pentacosane. Triacontane. System blank Figure. FOG analysis of a sample of polypropylene, followed by a system blank, showing no carryover of high-boiling compounds. Amount. Sulfur dioxide.. Trimethylsilanol.. -Butoxyethanol.. Propylene carbonate.. -(-Methoxy--methylethoxy)propan--ol.. -Methyl--pyrrolidinine.. -(-Butoxylethoxy)ethanol.. Tetradecane.. Dodecane.., -Dimethyldiphenyl ether. (-Benzyloxyphenyl)-ethylamine..,,,-Tetramethyl pentadecane. Figure. VOC analysis of a. mg sample of artificial leather.

Mean amount. mg sample. mg sample. Sulfur dioxide. ±.. Formic acid. ±.. Trimethylsilanol. ±.. Triethylamine. ±.. -Butoxyethanol. ±.. Propylene carbonate. ±.. -Methyl--pyrrolidinine. ±.. -(-Butoxyethoxy)ethanol. ±.., -Dimethyldiphenyl ether. ±.. -Cyclohexylundecane. ±.., -Methylene-bis. ±. (-(,-dimethylethyl)) --methylphenol. mg sample Figure. FOG analysis of three samples of artificial leather. Mean amount. mg sample.,-dichloropropan--ol. ±.. Triethylenediamine. ±.. -Ethylhexanoic acid. ±.. Octa-,-diene. ±..,-Dimethylquinoline. ±.. mg sample. mg sample Figure. VOC analysis of three samples of foam.

Mean amount. mg sample.,-dichloropropan--ol. ±.. Triethylenediamine. ±.. -Ethylhexanoic acid. ±..,-Dimethyl--oxobutanoic acid. ±.. Octa-,-diene. ±..,-Dimethylquinoline. ±.. Tris(-butoxyethyl) phosphate. ±.. mg sample. mg sample Figure. FOG analysis of three samples of foam. A µl sample of the activity mix was injected into the sampling end of a conditioned Tenax TA tube in a stream of inert gas using the Markes Calibration Solution Loading Rig (CSLR). During analysis, the split portion of the sample was re-collected into a second conditioned Tenax TA tube. Figure shows the chromatogram obtained from the analysis of a Tenax TA tube loaded with µl of activity test mix and desorbed using the VOC analysis conditions. This procedure was repeated a second time, giving three analyses from the one sample (Figure ). The lack of bias between the three chromatograms shows that there are no losses in the system, thus validating recovery of all analytes.

.. Peak shape for -ethylhexan--ol. Benzene. n-heptane. Toluene. n-octane. p-xylene. o-xylene. n-nonane. n-decane. -Ethylhexan--ol. n-undecane.,-dimethylphenol. n-dodecane. n-tridecane. n-tetradecane. Dicyclohexylamine. n-pentadecane. n-hexadecane. Bis(-ethylhexyl) adipate Figure. Analysis of. μg/µl activity test mix spiked onto a Tenax TA tube. Second re-collection First re-collection Original sample Figure. Repeated analyses of the activity test mix. Repeatability of toluene analysis A. µg sample of toluene was injected into tubes packed with Tenax TA. These samples were analyzed for week and produced the following values: Average recovery: % Standard deviation: % Minimum recovery: % (%) Maximum recovery: % (%) These were found to be within the limits outlined in VDA Method (bracketed). Linearity and limit of determination/detection System linearity was demonstrated over the range. µg by preparing a range of liquid standards of toluene and eicosane (n-c ) in methanol, and dotriacontane (n-c ) in n-hexane. These were introduced into the sampling end of conditioned Tenax TA tubes in a stream of clean inert gas. Detection and determination limits were determined in accordance with the procedure described in VDA Method. Split and GC conditions used correspond with the VOC and FOG method parameters, respectively. All tubes were desorbed at C to ensure complete recovery of the standard solutions from the Tenax TA sorbent.

Figures - show plots of the linearity of the system for toluene, eicosane, and dotriacontane. In each case, LOD and LOQ values were determined using the.. µg loading ranges (Table ). Table. Values for limit of detection (LOD) and limit of determination (LOQ) for the three compounds investigated over the loading range.-. µg. Peak area... R =....... R =. Compound LOD* LOQ Toluene. μg (<. μg). μg Eicosane. μg (<. μg). μg Dotriacontane. μg (<. μg). μg * The limit cited in VDA Method is given in parentheses. Loading (µg) Figure. Linearity of toluene over the loading range.- μg and (inset) over the range.-. μg. Peak area.... R =...... R =. Loading (µg) Figure. Linearity of eicosane over the loading range. μg and (inset) over the range.-. μg.... R =...... Peak area R =. Loading (µg) Figure. Linearity of dotriacontane over the loading range.- μg and (inset) over the range.-. μg.

Conclusions The suitability of Markes TD- thermal desorber for performing the analysis of automotive trim materials in accordance with VDA Method has been demonstrated. Analyses of a variety of typical trim materials/standard solutions demonstrated: Excellent linearity. Low detection/determination levels. Excellent peak shape for reactive (polar) compounds, demonstrating good system inertness. Repeatable results even for very high-boiling compounds. Key features of the TD- system that are essential for VDA Method include: Trademarks CSLR and TD- are trademarks of Markes International. Tenax is a registered trademark of Buchem B.V.. Applications were performed under the stated analytical conditions. Operation under different conditions, or with incompatible sample matrices, may impact the performance shown. For More Information These data represent typical results. For more information on our products and services, visit our Web site at www.agilent.com/chem. Leak-testing of each tube prior to analysis to ensure data integrity. Effective sealing of all sample tubes loaded onto the autosampler before and after analysis to prevent contamination and loss of volatiles. Inert flow path for compatibility with reactive species. Backflushed and electrically-cooled (cryogen-free) focusing trap for efficient trapping and desorption of compounds from C to n-c. Full EPC control of carrier gas through the TD system for optimum retention time stability and improved qualitative identification of minor compounds. Quantitative re-collection for repeat analysis or method validation, to demonstrate quantitative recovery through the system and allow method validation.

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., Printed in the USA July, -EN