COMPREHENSIVE LC X LC ANALYSIS OF FLAVORING INGREDIENTS IN DISTILLED SPIRITS

Similar documents
Screening of pesticides in water using SPE on line

A novel approach to the analysis of multivitamin by online supercritical fluid extraction/supercritical fluid chromatography

Chiral Separation Using SFC and HPLC

Preparative Separation of Active Components from Natural Products using Low-pressure Gradient Preparative HPLC

Development of high speed CYP cocktail inhibition assay using UHPLC-MS/MS

Evaluation of a novel glass vial overcoming adsorption effect for pharmaceutical drugs

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

A Method for Simultaneous Analysis of 174 Pesticides in Grape Using GC-MS/MS

HPLC Praktikum Skript

Highly sensitive quantitative estimation of genotoxic impurities from API and drug formulation using LC/MS/MS

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

Nexera UC Unified Chromatography

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Simultaneous determination of 74 kinds of pesticides in Chinese herbal medicine listed in Chinese pharmacopoeia (2015) by GPC-GC-MS/MS

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Highly sensitive quantitative analysis of Felodipine and Hydrochlorothiazide from plasma using LC/MS/MS

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS

Analysis of allergens found in cosmetics using MDGC-GCMS (Multi-Dimensional Gas Chromatograph Mass Spectrometer)

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003

Open Column Chromatography, GC, TLC, and HPLC

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research

Analysis of Beer by Comprehensive 2D-LC with the Agilent 1290 Infinity 2D-LC system

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

Benzodiazepines and Barbiturates

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Routine MS Detection for USP Chromatographic Methods

Research of Polychlorinated Biphenyls (PCBs) in Vegetables by GC-MS/MS

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

Application Note. Authors. Abstract. Food Testing & Agriculture. Stephen E. Reichenbach University of Nebraska Lincoln, NE, USA

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Biochemistry. Biochemical Techniques HPLC

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

HPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Chromatography. Gas Chromatography

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Successfully Scaling and Transferring HPLC and UPLC Methods

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Protein Sequencer PPSQ-31A / 33A C297-E055B

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

Agilent LC & LC-MS Cannabis Testing

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Comprehensive 2D-LC Analysis of Chinese Herbal Medicine

ChromTech HPLC System

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

High Performance Liquid Chromatography

Chapter content. Reference

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

High Pressure/Performance Liquid Chromatography (HPLC)

Analysis of Polyphenols in Saffron Petal Extracts with UHPLC/UV/MS

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Varian Galaxie Chromatography Data System for Preparative HPLC

Determination of Caffeine by HPLC

ION CHROMATOGRAPHY SYSTEM S 150

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Speeding up 2D chromatography (HPLCxSEC) at it s limits. ..fast, faster ups broken...

Volume 6, Issue 2, January February 2011; Article-015

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Instrumental Chemical Analysis

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

FAQ's. 1 - Which column would be the most appropriate for my application?

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

LC-MS Based Metabolomics

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

DEVELOPMENT OF PFCs HIGH SENSITIVITY ANALYSIS METHOD APPLIED RETENTION GAP TECHNIQUE WITH UPLC/MS/MS Tatsuya Ezaki 1, Nobutake Sato 1, Jun Yonekubo 1,

DEVELOPMENT OF HPLC METHOD FOR ANALYSIS OF NITRITE AND NITRATE IN VEGETABLE

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Expediting Achiral SFC Method Development Using a Multi-Channel SFC System with MS Detection

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Cation Exchange HPLC Columns

Structural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS

883 Basic IC plus. The smallest Metrohm ion chromatograph

penta-hilic UHPLC COLUMNS

Transcription:

PO-CON1574E COMPREHENSIVE LC X LC ANALYSIS OF FLAVORING INGREDIENTS IN DISTILLED SPIRITS HPLC 2015 PSB-MULTI-01 Gesa J. Dr. Schad; Brigitte Dr. Bollig; Robert Ludwig; Björn T. Dr. Erxleben Shimadzu Europa GmbH, Duisburg, Germany

Introduction Composition of flavoring ingredients in distilled spirits is largely dependent on make and storage of the product after distillation. The so-called aging of alcoholic beverages takes place in charred wooden, mostly oak barrels. During this process of maturation, wood components are extracted into the distillate, which has a major effect on their final aroma. The complex composition and a distinct change over the period of storage in the cask provide a unique profile for any distilled spirit after aging. Due to anaerobic decomposition of the lignin underneath the wood charcoal layer in the cask, aromatic aldehydes, such as vanillin or p-anisaldehyde are formed. Colour and (poly-)phenol content of the distillate are a result of extractable wood components. Additional flavoring ingredients are formed by oxidative, interactive chemical reactions of the various constituents. Table 1: Examples of flavoring ingredients in distilled spirits 2

A comprehensive two-dimensional LC method for the simultaneous determination of polyphenols, and a large number of different flavouring substances has been developed. This online 2D approach offers enhanced resolving power compared to a one dimensional run by employing two successive separations, with different selectivities in a single analysis. This LC x LC analysis also allows for 2D pattern profiling for quick and easy quality control and identification of counterfeit products. Degasser Mixer Column oven 6-Port 2-Position Valves Detector 2nd dimension column Solvent delivery pump Autosampler Mixer 1st dimension column Degasser Waste Figure 1: System configuration of Nexera-e two-dimensional LC system Instrument and Software A comprehensive separation is achieved on two distinct columns connected in series with a transfer system of two sample loops on 6-port 2-position valves located between them (figure 1). This interface cuts and then releases continuous fractions of the primary column effluent onto a fast separation column in the second dimension. This way, through continuous heart-cutting, the entire sample is subjected to two different separations. An ultra-fast UHPLC separation in the second dimension ensures that the bands injected onto the secondary column elute before the next fraction is injected. 3

Figure 2: Schematic demonstration of a two-dimensional LC x LC separation Figure 2 shows the schematic demonstration of a two-dimensional LC x LC separation. The wide compound peaks from the slow first dimension method undergo a fast second separation, that allows for co-eluting peaks to be resolved by the different selectivity of the 2 nd dimension column. In a two dimensional approach the chances for full separation even of complex samples are multiplied as peak capacity is increased and two different separation mechanisms are exploited. However, not only the instrument set-up is crucial, but also the software for visualization of the results. Even though the system is running two separate methods, data is recorded by only one detector. The ChromSquare software produces a 2D contour plot (see figure 3) based on the recorded data and the modulation time in the method the 2 nd dimension analysis time. 1D gradient 2D contour plot 2D gradient 2D separation Acquired chromatogram Loop A B A 1D separation Modulation Figure 3: Nexera-e System Operation Overview 4

Separation Method In order to benefit from the two-dimensional method set-up, the two separations must offer different selectivty. As there are lipophilic flavonoids, as well as very polar analytes among the compounds of interest, a RPxRP system was chosen with a purely lipophilic ODS (ACE 3 Super C18, 150 x 1.0 mm) and a polar embedded RP Cyano phase (ACE Excel 2 CN-ES; 100 x 2.1 mm). To further increase the differences between the two methods, ammonium formate buffer, ph 2.8 and acetonitrile were used as mobile phase in the first dimension the same buffer and methanol in the second separation method. Oven temperature was set to 45 C. The LCxLC assist software created the two-dimensional time program for a very slow 1D gradient of 8 to 43 %B in 60 min at a flow rate of 0.02 ml/min and an ultra-fast 2D gradient of just 1.6 min at a flow rate of 1.2 ml/min with increasing start %B from 30 to 40 over the time of the 1D gradient to match the increasing content of organic solvent from the first dimension effluent. Detection was carried out with a PDA detectot to evaluate the most sensitive wavelength for all compounds of interest during data analysis. Figure 4: Creation of 2D time program in LCxLC assist software Results After separate optimisation of the two gradient methods, over 20 compounds of interest with large differences in structure and physicochemical properties could be separated and quantified in one two-dimensional LCxLC separation. The contour plot of the analysis of a mixed standard solution is displayed in figure 5. In the chromatogram below the 2D plot the peaks separated in one chosen modulation time can be identified. Integration contours and peaks in the chromatogram are colour coded for clarification. UV spectra of each blob are also available. 5

Figure 5: Contour plot of the 2D separation of polyphenols, and different flavouring substances mixed standard sample First Edition: June, 2015 www.shimadzu.com/an/ For Research Use Only. Not for use in diagnostic procedures. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. Shimadzu Corporation, 2015