Effect of Magnetic Filter in a Volume Production Multicusp Ion Source

Similar documents
The Extraction of Negative Carbon Ions from a Volume Cusp Ion Source

Volume Production of D - Negative Ions in Low-Pressure D 2 Plasmas - Negative Ion Densities versus Plasma Parameters -

Relationship between production and extraction of D - /H - negative ions in a volume negative ion source

Multicusp Sources for Ion Beam Lithography Applications

Plasma Optimization in a Multicusp Ion Source by Using a Monte Carlo Simulation

The Q Machine. 60 cm 198 cm Oven. Plasma. 6 cm 30 cm. 50 cm. Axial. Probe. PUMP End Plate Magnet Coil. Filament Cathode. Radial. Hot Plate.

The ISIS Penning H - SPS and Diagnostic Developments at RAL

Progress of experimental study on negative ion production and extraction

1 AT/P5-05. Institute of Applied Physics, National Academy of Sciences of Ukraine, Sumy, Ukraine

Huashun Zhang. Ion Sources. With 187 Figures and 26 Tables Э SCIENCE PRESS. Springer

SPECTRAL INVESTIGATION OF A COMPLEX SPACE CHARGE STRUCTURE IN PLASMA

Increasing the Space Charge Limit and Other Effects of Cesium Seeding in Hydrogen Negative Ion Sources

Study of DC Cylindrical Magnetron by Langmuir Probe

Physics-based Investigation of Negative Ion Behavior in a Negativeion-rich Plasma using Integrated Diagnostics

Development of Long Pulse Neutral Beam Injector on JT-60U for JT-60SA

Beam Species Characteristics of High Current Ion Source for EAST Neutral Beam Injector

Commissioning the Front End Test Stand High Performance H - Ion Source at RAL

ICPMS Doherty Lecture 1

Modeling of an Extraction Lens System

ELECTRON CYCLOTRON RESONANCE DISCHARGE AS A SOURCE FOR HYDROGEN AND DEUTERIUM IONS PRODUCTION

STRONG DOUBLE LAYER STRUCTURE IN THERMIONIC VACUUM ARC PLASMA *

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

1) Jozef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia

Contents: 1) IEC and Helicon 2) What is HIIPER? 3) Analysis of Helicon 4) Coupling of the Helicon and the IEC 5) Conclusions 6) Acknowledgments

PhysicsAndMathsTutor.com 1

Beams and magnetized plasmas

Physical Performance Analysis And The Progress Of The Development Of The Negative Ion RF Source For The ITER NBI System

Regenerative Soot-IX: C3 as the dominant, stable carbon cluster in high pressure sooting discharges

Studies of Charge Separation Characteristics for Higher Density Plasma. in a Direct Energy Converter Using Slanted Cusp Magnetic Field

Chopping High-Intensity Ion Beams at FRANZ

D- Charge Exchange Ionizer for the JINR Polarized Ion Source POLARIS

Enhancement of an IEC Device with a Helicon Ion Source for Helium-3 Fusion

Performance Measurements of a High Powered Quad Confinement Thruster.

A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling

Neutron Transport Calculations Using Monte-Carlo Methods. Sean Lourette Fairport High School Advisor: Christian Stoeckl

Photoelectric Effect Experiment

Why do we accelerate particles?

FLASH CHAMBER OF A QUASI-CONTINUOUS VOLUME SOURCE OF NEGATIVE IONS

Diagnostic Lithium Beam System for COMPASS Tokamak

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

Modeling of Negative Ion Transport in Cesium-Seeded Volume Negative Ion Sources

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

Langmuir Probes as a Diagnostic to Study Plasma Parameter Dependancies, and Ion Acoustic Wave Propogation

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Neutral beam plasma heating

(Total for Question = 5 marks) PhysicsAndMathsTutor.com

Design and numerical simulation of thermionic electron gun

COMPACT NEUTRON GENERATORS FOR MEDICAL, HOME LAND SECURITY, AND PLANETARY EXPLORATION*

The Franck-Hertz Experiment David Ward The College of Charleston Phys 370/Experimental Physics Spring 1997

Contents Motivation Particle In Cell Method Projects Plasma and Ion Beam Simulations

Repetition: Practical Aspects

Beam dynamics studies of H-beam chopping in a LEBT for project X

Combinatorial RF Magnetron Sputtering for Rapid Materials Discovery: Methodology and Applications

~1 V ~20-40 V. Electron collector PLASMA. Ion extraction optics. Ionization zone. Mass Resolving section Ion detector. e - ~20 V Filament Heater

Recombination and Decay of Plasma Produced by Washer Stacked Plasma Gun inside a Curved Vacuum Chamber

Effect of Biasing on Electron Temperature in IR-T1 Tokamak

Characteristics and classification of plasmas

Long pulse and high power density H - ion beam accelerations for ITER - Achievement for 60 s acceleration of 1 MeV beam in QST-

Effect of Spiral Microwave Antenna Configuration on the Production of Nano-crystalline Film by Chemical Sputtering in ECR Plasma

3. Gas Detectors General introduction

Measurement of EEDF and Distribution of Primary Electron in a Bucket Ion Source

Optical Pumping of Rubidium

arxiv:physics/ v1 [physics.plasm-ph] 5 Nov 2004

Magnetic Field Design for a 2.45-GHz ECR Ion Source with Permanent Magnets

Chapter IX: Nuclear fusion

Anode double layer in magnetized radio frequency inductively coupled hydrogen plasma

Physics (B): Physics in Context

Spectroscopy A Powerful Diagnostic Tool in Source Development

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

KE = 1 2 mv2 = ev. (1)

Progress in long pulse production of powerful negative ion beams for JT-60SA and ITER

PIP-II Injector Test s Low Energy Beam Transport: Commissioning and Selected Measurements

SCALING OF HOLLOW CATHODE MAGNETRONS FOR METAL DEPOSITION a)

Physique des plasmas radiofréquence Pascal Chabert

Negative Ion Studies in an IEC Fusion Device

Sheaths: More complicated than you think a

Modélisation de sources plasma froid magnétisé

c = m/s h = Js e = C µ 0 = 4 π 10 7 T ma l ε 0 = C 2 N 1 1 = N m 2 C 2 me = 9.

The Franck-Hertz Experiment

Adjustment of electron temperature in ECR microwave plasma

This lab was adapted from Kwantlen University College s Determination of e/m lab.

Electrode and Limiter Biasing Experiments on the Tokamak ISTTOK

vacuum analysis plasma diagnostics surface science gas analysis

A novel helicon plasma source for negative ion beams for fusion

Robert A. Meger Richard F. Fernster Martin Lampe W. M. Manheimer NOTICE

AQA Chemistry A-Level : Atomic Structure

Revision Guide for Chapter 14

Measurements of plasma parameters in the plume of electric propulsion devices Recent works performed at the ESA Propulsion Laboratory

A comparison of emissive probe techniques for electric potential measurements in a Hall thruster plasma

Response of thin foil Faraday Cup lost alpha particle detector in intense neutron and gamma ray radiation fields

DPP06 Meeting of The American Physical Society. Production of negative ion plasmas using perfluoromethylcyclohexane (C 7 F 14 )

CBSE XII Physics 2015

ESTIMATION OF ELECTRON TEMPERATURE IN ATMOSPHERIC PRESSURE DIELECTRIC BARRIER DISCHARGE USING LINE INTENSITY RATIO METHOD

Chapter 5: Nanoparticle Production from Cathode Sputtering. in High-Pressure Microhollow Cathode and Arc Discharges

POLARIZED DEUTERONS AT THE NUCLOTRON 1

Neutron Generators for Detection of Explosives and Illicit Materials

The electron impact studies of ground state molecules have been extensively carried out, both experimentally and theoretically However, work on

Broad Ion Beams. Thin Film Sputter Etching broad ion beam technology. Broad Ion Beams August 2013

Assessment of the Azimuthal Homogeneity of the Neutral Gas in a Hall Effect Thruster using Electron Beam Fluorescence

International Journal of Scientific & Engineering Research, Volume 4, Issue 7, July ISSN

Transcription:

Effect of Magnetic Filter in a Volume Production Multicusp Ion Source Anand George 1, 3 a), Stephane Melanson 1, Dave Potkins 1, Morgan Dehnel 1, Hamish McDonald 2, Chris Philpott 2, Neil G.R. Broderick 3 1 D-Pace Inc. Suite 305, 625 Front Street, Nelson, BC, Canada. 2 Buckley Systems, 6 Bowden Road, Mt. Wellington, Auckland, NZ. 3 Dodd-Walls Centre, Department of Physics, University of Auckland, NZ. a) Corresponding author: a.george@auckland.ac.nz Abstract. D-Pace's volume production multicusp ion source utilizes dipole magnetic fields inside the plasma chamber to filter out energetic electrons that lead to the destruction of negative ions inside the source. The ion source uses the same magnetic field for the extraction of negative hydrogen and deuterium ions. The amount of deuterium ions extracted from the source is about 1/3 of the amount of negative hydrogen ions extracted. In this paper, we investigate if different magnetic field strengths are required for hydrogen and deuterium plasmas for maximum negative ion extraction. The effect of varying the strength of the magnetic filter fields in the extraction of negative ions of hydrogen and deuterium is studied. The response of plasma parameters like electron temperature and electron density to different magnetic fields are determined using a Langmuir probe. INTRODUCTION The ion source used for this study is a D-Pace filament based multicusp ion source licensed from TRIUMF[1], which produces negative ions based on volume production methods and uses low-pressure discharge plasmas of H 2 and D 2. This ion source is capable of producing 18 ma of H beam current at a beam energy of 30 kev[2]. However, the ion source achieves only 6 ma of D beam current under the same conditions[2]. We are attempting to increase the D beam current to 10 ma, so that the D-Pace ion source can achieve the requirements for Boron Neutron Capture Therapy (BNCT) applications[3]. The reactions producing D ions are believed to be the same as those producing H ions[4]. It is clear that volume production of negative ions of H and D occurs through dissociated electron attachment of low energy electrons (~0.5 ev) to molecules at a higher vibrational level[5]. Vibrationally excited molecules are created inside the volume production ion source mainly through collisions of gas molecules with high energy electrons in the plasma [6]. The filtering of high energy electrons in the region close to the extraction is accomplished through the presence of transverse magnetic fields (magnetic filter)[7].the ion source uses the same magnetic filter strength for the extraction of both hydrogen and deuterium ions. Since the D-Pace ion source is optimized for the production of H ions, it will be interesting to study if the same magnetic filter field strength is optimized for the formation of maximum amount of D ions. Magnetic filters of different strengths are placed near the extraction region of the ion source in the current study. The maximum amount of H and D beam currents that can be extracted from the ion source under these different magnetic fields are measured. The variations in the plasma characteristics of H 2 and D 2 under different magnetic fields are analyzed using a Langmuir probe.

ION SOURCE AND MAGNETIC FILTER FIELDS The schematic of the ion source used is presented in Fig.1a). Plasma is sustained inside the plasma chamber of the ion source via thermionic emission from the electrically heated filaments. Filaments are made of four half circles of tantalum. The plasma is confined by 10 rows of Sm 2Co 17 magnets and another 4 rows of magnets on the back plate, which holds the filaments. These magnets form cusp fields which confine the electrons in the plasma. The ion source uses three electrodes in the extraction system, consisting of the plasma electrode, the extraction electrode and the ground electrode, as shown in Fig. 1 b). Different power supplies control each of the electrodes. The plasma electrode and the extraction electrode are biased positively. The co-extracted electrons are dumped on the extraction electrode. Thus, the current measured on the extraction electrode power supply approximates the coextracted electron current. The ion source is biased at a negative potential with respect to the ground electrode for the extraction of negative ions. The magnitude of the negative potential determines the energy of the beam (0-30 kev). (a) FIGURE 1. a) Section view of the ion source. b) Schematic of the extraction system used for ion extraction. FIGURE 2. Variation in the magnetic field strength along the central axis of the ion source for different magnetic dipole filter fields. The position values correspond to the locations indicated in Fig. 1a). Each field is indicated with the integrated field value (Gauss mm) over the 160 mm length. The magnetic dipole filter indicated in Fig. 1 a) creates a transverse magnetic field. The electrons traversing the fields experience the Lorentz force and they follow the Larmor radius trajectory. This filters out the high energy electrons from the extraction region. The strength of the transverse magnetic filter field is varied by changing the Sm 2Co 17 magnet arrangement in the magnetic filter around the central axis of the ion source. The variation of the magnetic field along the axis of the ion source for different magnet arrangements in the magnetic filter is shown in

Fig. 2. The peaks (A, B) correspond to the field created by the two sets of magnets in the extraction electrode, as shown in Fig. 1a). The magnetic field created by these magnets deflects the co-extracted electrons towards the extraction electrode, which is biased at a positive potential and thus removes the electrons from the beam line. A Faraday cup located 510 mm downstream from the plasma electrode is used for measuring the magnitude of the ion beam current. MAXIMUM ION CURRENT EXTRACTED FROM THE ION SOURCE An upper limit exists for the maximum amount of ion beam current that can be extracted from the D-Pace ion source, for a particular plasma density, due to space charge effects. This is predicted by the Child Langmuir law[8]. The total amount of charged particles reaching the ground electrode from the plasma chamber is denoted as the bias current (I bias ). It is measured on the power supply, which controls the magnitude of the negative bias between the ion source and ground electrode. The variation of I bias for different voltages on the extraction electrode at constant arc currents is shown in Fig. 3a). It can be seen that the ion source extraction system follows the space charge limited emission model, where the total amount of current extracted from the source follows a V 3/2 characteristic [9]. The extracted current flattens out beyond a particular extraction voltage, as it approaches the plasma density limit. (a) FIGURE 3. a) Variation of total extracted current (Ibias) in hydrogen plasma for different extraction voltages, at constant arc currents, an arc voltage of 120 V, a bias voltage of 5 kv, a plasma voltage of 3.5 V and gas flow of 7.5 sccm. The V 3/2 line is shown for reference only. b) Method of finding Ibias, m value from the data. A method of finding the maximum I bias, (I bias, m) for a particular plasma density (constant arc current) is illustrated in Fig. 3 b).the typical shape of the data curve indicates the presence of an inflection point. At first, the inflection point of the actual data curve is found using the second derivative method. Inflection point is the point where the second derivative value equals zero and crosses from positive values to negative values. Then, a new line is created with a slope value equal to half of the value of slope at the inflection point. The actual data curve will have a maximum and a minimum with respect to the new line. The maxima value is determined by the derivative method (differentiating the actual data curve with respect to the new line) and this value is assigned to I bias, m. I bias, m values are determined using the method mentioned above for different arc currents and magnetic filter field intensities for H 2 and D 2 plasmas. Plasma electrode voltages and gas flows are optimized before each measurement by tuning them to achieve maximum current at the Faraday cup, for a fixed arc current. The results are shown in Fig. 4a) and 4b). As evident from the graphs, the magnetic filter field intensity should be optimized for maximum ion extraction. Low intensity fields (< 3500 G mm) and very high intensity fields (>10000 G mm) will decrease the amount of beam current extracted from the ion source. As already known[2], more ion current can be extracted from hydrogen plasma compared to deuterium plasma. The graph indicates different responses for deuterium and hydrogen for the varying filter fields. The magnetic field intensities required for maximum ion extraction is higher for deuterium plasma (~ 7000-8000 G mm) compared to hydrogen plasma (~ 4000-6000 G mm).

(a) FIGURE 4. a),b) Variation of Ibias, m for Hydrogen and Deuterium plasmas at different magnetic filter field intensities and arc currents, at an arc voltage of 120 V and a bias voltage of 5 kv. Gas flows and plasma electrode voltages are tuned such that the Faraday cup current is maximum. PLASMA PARAMETERS FOR H2 AND D2 A movable Langmuir probe made of tantalum and enclosed in a ceramic sleeve is used for measuring the plasma properties of H 2 and D 2. The probe has a tip length of 5 mm and a diameter of 1.6 mm. It is inserted into the plasma through the extraction side of the ion source as shown in Fig. 1a). The current-voltage characteristics of the probe is determined at different locations inside the plasma chamber for H 2 and D 2 plasmas. Plasma electrode potential and bias potential are maintained at ground for the Langmuir probe measurements. A gas flow of 7.5 sccm and an arc current of 5 A at an arc voltage of 120 V is used for the study. The plasma potential V p is determined by finding the inflection point of the V-I characteristics through the second derivative method. An exponential fit using the equation (1) is used to find the electron temperature (T e ) and electron density (n e ) [10]. I = 1 2 ean eu B { 1 + [ 2M 1 2 i πm ] exp ( e(v p V) )} kt e (1) M i and m represent the H + ion mass and electron mass respectively. U B is the Bohm velocity, A is probe surface area, k is the Boltzmann constant and V is the varying voltage on the probe. The results of measurement of the electron temperature and the electron density at different locations inside the ion source for different magnetic filter field intensities are shown in Fig. 5. (a)

(c) (d) FIGURE 5. a), b) Variation of electron temperature inside the ion source for different magnetic filter fields for H2 and D2. c), d) Variation of electron density inside the source for different magnetic filter fields for H2 and D2. An arc current of 5 A, arc voltage of 120 V and gas flow of 7.5 sccm is used. The results indicate a higher electron temperature and electron density distribution inside the ion source for deuterium plasma compared to hydrogen. As evident from the graphs in Fig. 5 a) and 5 b), increasing the magnetic filter field intensity reduces the electron temperature close to the plasma electrode region. The lowest magnetic field intensity (820 G mm) results in an electron temperature on the order of 1eV at 5 mm from the plasma electrode for H 2 and D 2. The electron temperature needed for dissociative electron attachment reactions[5], which produces H and D ions, is on the order of 0.5 ev. The graphs reveal that a magnetic field intensity around 5000 G mm is required for hydrogen plasma to reduce the electron temperature to 0.5 ev, whereas deuterium plasma require fields around 8000 G mm to achieve this temperature. This can explain the behavior observed in Fig. 4, where a higher magnetic field intensity is required for achieving maximum extracted current for deuterium, compared to hydrogen. Figures 5 c) and 5 d) shows that the filter field reduces the electron density in the regions close to the plasma electrode (0-30 mm), with the lowest field resulting in the highest density and vice versa. The decrease in the electron density for high magnetic fields can be one of the reasons for the decrease of extracted ion currents at high magnetic filter fields. CONCLUSION The study was conducted to understand the influence of different dipole magnetic filter fields on beam currents extracted from the TRIUMF licensed D-Pace ion source. The maximum beam current that could be extracted from the ion source for a given plasma density was determined for H 2 and D 2 plasmas. This revealed that deuterium plasma requires a higher magnetic filter field intensity (7000-8000 G mm) compared to hydrogen (4000-6000 G mm) for extraction of maximum current. Plasma parameters of H 2 and D 2 under different magnetic filter fields were studied with a Langmuir probe. Results indicated that a higher magnetic field was required for the D 2 plasma compared to H 2, for reducing the electron temperature near the plasma electrode (at 5 mm) to ~0.5 ev. The distribution of electron temperature and density along the central axis of the ion source for H 2 and D 2 plasmas were also determined in the current study. Future works aim at measuring the maximum ion current that can be extracted from the TRIUMF licensed D-Pace ion source for D 2, for very high arc currents (~50 A) at a bias voltage of 30 kv. We need to determine if the differences in the intensity of the optimum magnetic field for H 2 and D 2, observed in the current study, are present at very high arc currents also. ACKNOWLEDGEMETS The authors are grateful to New Zealand s Callaghan Innovation grant and Canada s SR&ED programme for significant R&D funding and Buckley Systems, New Zealand for the research support.

REFERENCES [1] T. Kuo et al., "On the development of a 15 ma direct current H multicusp source," Review of scientific instruments, vol. 67, no. 3, pp. 1314-1316, 1996. [2] S. Melanson, M. Dehnel, H. McDonald, C. Philpott, and D. Potkins, "H-, D-, C2-: A Comparison of RF andfilament Powered Volume-Cusp Ion Sources," in 8th Int. Particle Accelerator Conf.(IPAC'17), Copenhagen, Denmark, 14â 19 May, 2017, 2017, pp. 1685-1687: JACOW, Geneva, Switzerland. [3] M. Capoulat and A. Kreiner, "A 13C (d, n)-based epithermal neutron source for Boron Neutron Capture Therapy," Physica Medica: European Journal of Medical Physics, vol. 33, pp. 106-113, 2017. [4] O. Fukumasa and S. Mori, "Volume production of D negative ions in low-pressure D2 plasmas negative ion densities versus plasma parameters," Nuclear fusion, vol. 46, no. 6, p. S287, 2006. [5] M. Bacal and M. Wada, "Negative hydrogen ion production mechanisms," Applied physics reviews, vol. 2, no. 2, p. 021305, 2015. [6] K. Jayamanna, F. Ames, I. Bylinskii, M. Lovera, and B. Minato, "A 60 ma DC H multi cusp ion source developed at TRIUMF," Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 895, pp. 150-157, 2018. [7] K. Ehlers and K. Leung, "Effect of a magnetic filter on hydrogen ion species in a multicusp ion source," Review of Scientific Instruments, vol. 52, no. 10, pp. 1452-1458, 1981. [8] S. Lawrie, D. Faircloth, A. Letchford, C. Gabor, and J. Pozimski, "Plasma meniscus and extraction electrode studies of the ISIS H ion source," Review of Scientific Instruments, vol. 81, no. 2, p. 02A707, 2010. [9] S. Lawrie, D. Faircloth, A. Letchford, M. Whitehead, and T. Wood, "Detailed beam and plasma measurements on the vessel for extraction and source plasma analyses (VESPA) Penning H ion source," Review of scientific instruments, vol. 87, no. 2, p. 02B122, 2016. [10] R. L. Merlino, "Understanding Langmuir probe current-voltage characteristics," American Journal of Physics, vol. 75, no. 12, pp. 1078-1085, 2007.