How to Prepare an Experiment using the Gamma Beam System at ELI-NP

Similar documents
GAMMA BEAM DELIVERY AND DIAGNOSTICS

Gamma beam system at ELI-NP

NUCLEAR PHOTONICS. Opportunities for photonuclear reactions at the ELI-NP facility. Andreas Zilges University of Cologne.

Extreme Light Infrastructure - Nuclear Physics ELI - NP

French-Ukrainian workshop Kevin Dupraz 1 ELI-NP-GBS. Extreme Light Infrastructure Nuclear Physics Gamma Beam Source

Photoneutron reactions studies at ELI-NP using a direct neutron multiplicity sorting method Dan Filipescu

Extreme Light Infrastructure Nuclear Physics (ELI NP): Present status and perspectives

OPTIMIZING RF LINACS AS DRIVERS FOR INVERSE COMPTON SOURCES: THE ELI-NP CASE

Implementation status of the extreme light infrastructure - nuclear physics (ELI-NP) project

High Energy Photons at HI S

Experiments with combined laser and gamma beams at ELI-NP

2. THE HIGS FACILITY 2.1 The Free-Electron Laser Source

Photons in the universe. Indian Institute of Technology Ropar

Nuclear AstroPhysics at ELI-NP: preliminary experiments with ELISSA detector. Giovanni Luca Guardo

Development and test of the high-precision -beam monitor at the ESFRI facility ELI-NP

Romanian Reports in Physics, Vol. 68, Supplement, P. S5 S10, 2016 INTRODUCTION

Day-one photonuclear physics at ELI-NP

Characterizations and Diagnostics of Compton Light Source

Extreme Light Infrastructure Nuclear Physics

A European Proposal for the Compton Gamma-ray Source of ELI-NP

Ultra-intense laser and gamma beam systems at ELI-NP

Photofission of 238-U Nuclei

Photonuclear studies with gamma beams Gamma above neutron threshold

HIGS - A High-intensity, Mono-energetic, and Tunable Source of Polarized Gamma-rays

SLAC Summer School on Electron and Photon Beams. Tor Raubenheimer Lecture #2: Inverse Compton and FEL s

Challenges for the HI γs Compton Program

Laser-based acceleration for nuclear physics experiments at ELI-NP

ERL FACILITY AT CERN FOR APPLICATIONS

X ray and XUV phase contrast diagnostics for ELI NP

Development status of non-destructive assay of nuclear material by using laser Compton scattered gamma-rays

Physics studies with brilliant narrow-width γ -beams at the new ELI-NP Facility

BIG A Gamma Ray Source at FACET-II

Nuclear Science and applications with the next generation of High Power Lasers and Gamma beams

The Extreme Light Infrastructure Nuclear Physics Facility (ELI-NP): Project implementation and overview of the scientific program

Pushing the limits of laser synchrotron light sources

LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

Few-Body HIgS

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

Neutron emission asymmetries from linearly polarized γ rays on nat Cd, nat Sn, and 181 Ta

Development of Soft X-rayX using Laser Compton Scattering

GAMMA RAY OPTICS. Michael Jentschel Institut Laue-Langevin, Grenoble, France

1 Introduction. Figure 1: SPARC LAB Thomson source schematic layout.

Neutron and gamma ray measurements. for fusion experiments and spallation sources

Nuclear Resonance Fluorescence with. NRF with monoenergetic photons and fundamental experiments at ELI-NP. Julius Wilhelmy

High brilliance photon pulses interacting with relativistic electron and proton beams

The interaction of radiation with matter

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Small Quantum Systems Scientific Instrument

Radiation Signals and Signatures in a Detector (Gamma spectroscopy) Sangkyu Lee

FLASH overview. Nikola Stojanovic. PIDID collaboration meeting, Hamburg,

Fissile material experiments at the Device Assembly Facility

MaRIE. MaRIE X-Ray Free-Electron Laser Pre-Conceptual Design

Observation of Coherent Optical Transition Radiation in the LCLS Linac

Linac Driven Free Electron Lasers (III)

THE INSTALLATION FOR EXPERIMENTAL NEUTRON SPECTRA RESEARCH IN REACTOR MATERIALS COMPOSITIONS Hliustin D.V. Institute for Nuclear Research, Moscow,

A Simple Estimate of Production of Medical Isotopes by Photo-Neutron Reaction at the Canadian Light Source

Monte Carlo Characterization of a Pulsed Laser-Wakefield Driven Monochromatic X-Ray Source

Photonuclear Data at ELI-NP

STAR (Southern Europe Thomson Back-Scattering Source for Applied Research) State of the Art

Detection of γ-rays from nuclear decay: 0.1 < E γ < 20 MeV

High-efficiency and fast-timing scintillators

Laser Ion Acceleration: Status and Perspectives for Fusion

An introduction to Neutron Resonance Densitometry (Short Summary)

Light Source I. Takashi TANAKA (RIKEN SPring-8 Center) Cheiron 2012: Light Source I

Intrinsic beam emittance of laser-accelerated electrons measured by x-ray spectroscopic imaging

Experimental Optimization of Electron Beams for Generating THz CTR and CDR with PITZ

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons

Diagnostic Systems for Characterizing Electron Sources at the Photo Injector Test Facility at DESY, Zeuthen site

Present and Future of Fission at n_tof

Emergency information

Deuteron activation cross section measurements at the NPI cyclotron

A Photon Collider Experiment based on SLC

Positron program at the Idaho Accelerator Center. Giulio Stancari Idaho State University and Jefferson Lab

Preparatory experiments for cold-neutron induced fission studies at IKI

Fission Studies at the New ELI-NP Facility

ENERGY DEPOSITION EFFECTS OF THE X PHOTON BEAM ON THE MIRROR OF PLASMON-X EXPERIMENT AT LI2FE. Francesco Broggi, Luca Serafini

The VELA and CLARA Test Facilities at Daresbury Laboratory Peter McIntosh, STFC on behalf of the VELA and CLARA Development Teams

Laser Compton Scattering Gamma-Ray Experiments for Supernova Neutrino Process )

Nuclear Photonics: Basic facts, opportunities, and limitations

Two-Stage Chirped-Beam SASE-FEL for High Power Femtosecond X-Ray Pulse Generation

Microbunching Workshop 2010 March 24, 2010, Frascati, Italy. Zhirong Huang

W. Udo Schröder Departments of Chemistry & of Physics and Astronomy

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Development of a Hard X-Ray Polarimeter for Solar Flares and Gamma-Ray Bursts

New light in nuclear physics: The extreme light infrastructure

Update on and the Issue of Circularly-Polarized On-Axis Harmonics

Beam Dynamics and SASE Simulations for XFEL. Igor Zagorodnov DESY

Developments for the FEL user facility

Research with Synchrotron Radiation. Part I

Compton Scattering Effect and Physics of Compton Photon Beams. Compton Photon Sources around the World, Present and Future

Gamma beam industrial applications at ELI-NP

GOVERNMENT OF ROMANIA. Sectoral Operational Programme Increase of Economic Competitiveness Investments for Your Future

Femto-second FEL Generation with Very Low Charge at LCLS

Coherent X-Ray Sources: Synchrotron, ERL, XFEL

X-ray Free-electron Lasers

An Overview of the Activities of ICS Sources in China

Experimental Measurements of the ORION Photoinjector Drive Laser Oscillator Subsystem

The UCLA/LLNL Inverse Compton Scattering Experiment: PLEIADES

A Brief Introduction to Medical Imaging. Outline

Week 7: Ch. 10 Spec. w/ Scintillation Ctrs. Photomultiplier Devices

Transcription:

EUROPEAN UNION GOVERNMENT OF ROMANIA Structural Instruments 2007-2013 Project co-financed by the European Regional Development Fund How to Prepare an Experiment using the Gamma Beam System at ELI-NP Catalin Matei ELI-NP, Romania Carpathian Summer School of Physics, 06/2016

outline Gamma Beam System: layout and status GBS Parameters & Protocols Diagnostics from EuroGammaS Diagnostics developed by ELI-NP Experimental areas and instruments #ELINP #CSSP2016

Gamma Beam System: general layout and status

ELI-NP large equipment High Power Laser System - 2 x 10 PW maximum power contracted by Thales Optronique SA (~65 M ) Gamma Beam System - high intensity, tunable energy up to 20MeV contracted by EuroGammaS Consortium led by INFN Rome (~65 M )

ELI-NP experimental areas Anti vibration platform Platform vibrations ±1 µm @ < 10 Hz Laboratories HPLS Experimental caves GBS

The Gamma Beam System (GBS) gamma rays from Inverse Compton Scattering photon scattering on ultra relativistic electrons (g 1) the most efficient frequency amplifier Photon accelerator maximum upshift: head on collision (θ L =0) & backscattering (θ γ =0) E γ = 2γ 2 e 1+ ( γ θ ) e 1+ cosθ γ 2 + a 2 0 L + 4γ ee mc L 2 E L

Gamma Beam System Layout Photo gun e source Interaction Laser High Energy e RF LINAC High Energy 720 MeV Interaction Laser Low Energy e RF LINAC Low Energy 300 MeV Photo gun Laser

Gamma Beam System Layout Low Energy Gamma Beam < 3.5 MeV Photo gun e source Interaction Laser High Energy e RF LINAC High Energy 720 MeV Interaction Laser Low Energy e RF LINAC Low Energy 300 MeV Photo gun Laser

Gamma Beam System Layout High Energy Gamma Beam < 19.5 MeV Photo gun e source Interaction Laser High Energy e RF LINAC High Energy 720 MeV Interaction Laser Low Energy e RF LINAC Low Energy 300 MeV Photo gun Laser

The Gamma Beam System (GBS) Parameter [units] Value Photon energy [MeV] 0.2 19.5 Spectral density [ph/s/ev] > 10 4 Bandwidth < 0.5 % # photons / shot FWHM bdw. 1.0 4.0. 10 5 Low energy stage: Eγ < 3.5 MeV Q1 2017 High energy stage: Eγ < 19.5 MeV Q4 2018 # photons/sec FWHM bdw. 2.0 8.0. 10 8 Source rms size [µm] 10 30 Source rms divergence [ µrad] 25 250 Peak brill. [N ph /sec. mm 2 mrad 2. 0.1%] 10 22 10 24 Radiation pulse length [ps] 0.7 1.5 Linear polarization > 99 % Macro repetition rate [Hz] 100 # of pulses per macropulse >31 Pulse to pulse separation [ns] 16

GBS Parameters and Protocols

spatial & temporal parameters

spectral parameters

power parameters

Diagnostics from EuroGammaS

! EuroGammaS diagnostics station

Diagnostics developed by ELI-NP

gamma beam - spatial parameters

spatial monitoring l l l CCD camera detector system, scintillator converter, mirror possible image collection at microbunch level with fast CCD design requirements: sub-mm resolution and high contrast

gamma beam - temporal parameters

temporal structure monitoring 10 ms (100 Hz) 16 ns 16 ns >31 pulses for 512 ns @ 0.5J/pulse l l beam monitor would be placed near one of the major beam-matter interaction points: collimators, attenuator, beam dump use a small 2 x2 LaBr 3 may be able to count microbunches

gamma beam - spectral parameters

energy & bandwidth - detectors l attenuated beam l HPGe (150%) l FWHM = 2.2 kev at 1.3 MeV l LaBr 3 (3 x 4 ) l anti-compton shield l main use for energy spread w/ HPGe l possible use for intensity and time structure w/ LaBr 3 l NaI annulus 15 cm diameter, 25 cm long

energy & bandwidth - proposed design

gamma beam polarization methods l l photo-dissociation of the deuteron in the d(γ,n)p reaction significant theoretical and experimental work over the last 40 years to understand the differential cross section and polarization asymmetry l l Nuclear Resonance Fluorescence the angular distribution of the emitted gamma rays depends on the multipolarity and electric or magnetic character of the transition several candidates have been identified based on the strength of the transition and the availability of the material l l Compton scattering use the quantum mechanical Klein-Nishina differential cross section for polarized photons could also be used for beam intensity and bandwidth

gamma beam polarization dgn reaction

dgn @ HIGS circular polarized beam E γ = 3 MeV E n =384 kev (ideal beam & target) Li-glass at 15 cm D 2 O target (L=4 cm, Φ=3 cm)

dgn @ HIGS linear polarized beam E γ = 3 MeV E n =384 kev (ideal beam & target) Li-glass at 15 cm D 2 O target (L=4 cm, Φ=3 cm)

Y C,L Apol counts P dgn P gamma beam polarization Y L reaction YL Apol = γ flash 105 in plane YC P L BYpol YC in plane 384 kev 104 Bpol out plane + out plane Apol Ameasured pol Aexpected pol 30 35 40 45 50 55 60 Bpol 65 70 75 YL YC = 0.9 0.89 = = 98.9% 0.9 80 TOF (ns) Linear polarization, in-plane vs. out-of-plane P P counts L YY L C YC Y in plane plane in = P P Y LL pol= AApol Y C YC Y in plane plane in 600 P P YYLL YYCC out out plane plane P P YYLL + + YYCC out out plane plane C,L,= 2650 33 430 232 43 measured A pol ABmeasured = 0.89, pol pol expected = expectedapol = =9 103 102 P YC 2650 330 430 2320 430 + 710 420 892 290 892 = 0.89

gamma beam polarization dgn reaction P IOP P S M R : April 8, 2016 R : May 12, 2016 A : May 22, 2016 P :???, 2016 Investigation of the d(,n)p reaction for gamma beam monitoring at ELI-NP C. Matei, a,1 J.M. Mueller, b,c M.H. Sikora, b,d G. Suliman, a C.A. Ur a and H.R. Weller b,d a Extreme Light Infrastructure Nuclear Physics, Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering, Bucharest-Magurele, 077125, Romania b Triangle Universities Nuclear Laboratory, Durham, North Carolina 27708, U.S.A. c Department of Nuclear Engineering, North Carolina State University, Raleigh, North Carolina 27695, U.S.A. d Department of Physics, Duke University, Durham, North Carolina 27708, U.S.A.

let s design dgn instrument for ELI-NP T γ T n T 0 γ n D2 O 10 5 γ GBS 7 MeV E γ =7 MeV è E n =2.4 MeV v γ =30 cm/ns v n =2.1 cm/ns TOF (ns) distance = 35 cm T γ =T 0 +1 ns T n =T 0 +17 ns

let s design dgn instrument for ELI-NP every 16 ns n γ D2 O 10 5 γ GBS 7 MeV t t+16 t+32 t+48 TOF (ns)

TOF spectrum at ELI-NP T n =T 0 +6-10 ns distance = 12-20 cm n D2 O γ t t+16 t+32 t+48 TOF (ns)

TOF spectrum at ELI-NP T n =T 0 +22-26 ns distance = 45-50 cm n D2 O γ t t+16 t+32 t+48 TOF (ns)

gamma beam polarization dgn reaction l d(γ,n)p systems used at HIGS l D 2 O cell 4 cm long l threshold reaction 3 MeV l well known cross sections ~3% l 3-4 neutron detectors l Li-glass below 4 MeV l NE213-type above 4 MeV l beam fluence accurate to 5%

gamma beam - power parameters

gamma beam intensity dgn reaction

gamma beam fluence w/ fission l simple design l almost 100% efficiency l U-235, U-238, Pu-239 l areal density determined to 1% l photofission cross sections to 5% l usable above 6 MeV l P-10 gas at max 1.2 bar l beam fluence accurate to 5%

gamma beam fluence w/ fission l simple design l almost 100% efficiency l U-235, U-238, Pu-239 l areal density determined to 1% l photofission cross sections to 1% l usable above 6 MeV l P-10 gas at max 1.2 bar l beam fluence accurate to 2% Estimated fission rates for 200 µg target

summary GBS & diagnostics precise measurement of beam parameters is essential multiple monitoring devices (the more, the better) it doesn t stop here. more devices to be proposed experiments have dedicated floor space beam transport is versatile / change is possible diagnostic instruments are movable