Progress in long pulse production of powerful negative ion beams for JT-60SA and ITER

Similar documents
Long-pulse acceleration of 1MeV negative ion beams toward ITER and JT-60SA neutral beam injectors

Long pulse and high power density H - ion beam accelerations for ITER - Achievement for 60 s acceleration of 1 MeV beam in QST-

IT/P7-4 High energy, high current accelerator development for ITER NBI at JADA

Development of Long Pulse Neutral Beam Injector on JT-60U for JT-60SA

Long-pulse acceleration of 1MeV negative ion beams toward ITER and JT-60SA neutral beam injectors

Progress of experimental study on negative ion production and extraction

Status and Programmes on Negative Ion Beams at JAERI

Physical Performance Analysis And The Progress Of The Development Of The Negative Ion RF Source For The ITER NBI System

Ion Beam Sources for Neutral Beam Injectors: studies and design for components active cooling and caesium ovens

Modeling activities on the negative-ion-based Neutral Beam Injectors of the Large Helical Device

Physics-based Investigation of Negative Ion Behavior in a Negativeion-rich Plasma using Integrated Diagnostics

Advanced Ion Beam Calorimetry for the Test Facility ELISE

Relationship between production and extraction of D - /H - negative ions in a volume negative ion source

POLARIZED DEUTERONS AT THE NUCLOTRON 1

Beyond ITER: Neutral beams for DEMO

Volume Production of D - Negative Ions in Low-Pressure D 2 Plasmas - Negative Ion Densities versus Plasma Parameters -

Towards powerful negative ion beams at the test facility ELISE for the ITER and DEMO NBI systems

Spherical Torus Fusion Contributions and Game-Changing Issues

D- Charge Exchange Ionizer for the JINR Polarized Ion Source POLARIS

Thermo-mechanical design of the SINGAP accelerator grids for ITER NB injectors

Dynamics of ion internal transport barrier in LHD heliotron and JT-60U tokamak plasmas

A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling

Power transmission from the ITER model negative ion source on MANTIS

Beam Species Characteristics of High Current Ion Source for EAST Neutral Beam Injector

T. S. Kim and S. H. Jeong Korea Atomic Energy Research Institute, Daejeon, Korea

HIGH PERFORMANCE EXPERIMENTS IN JT-60U REVERSED SHEAR DISCHARGES

Cesium Dynamics and H - Density in the Extended Boundary Layer of Negative Hydrogen Ion Sources for Fusion

PIP-II Injector Test s Low Energy Beam Transport: Commissioning and Selected Measurements

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

High-Intensity Ion Beam Neutralization and Drift Compression Experiments

Driving Mechanism of SOL Plasma Flow and Effects on the Divertor Performance in JT-60U

STEADY-STATE EXHAUST OF HELIUM ASH IN THE W-SHAPED DIVERTOR OF JT-60U

Heating and Current Drive by Electron Cyclotron Waves in JT-60U

Study of High-energy Ion Tail Formation with Second Harmonic ICRF Heating and NBI in LHD

Modeling of Negative Ion Transport in Cesium-Seeded Volume Negative Ion Sources

Plasma heating with neutral beam injection

Evolution of Bootstrap-Sustained Discharge in JT-60U

Reconstruction of the two-dimensional energy flux profile of a particle beam using thermographic measurements

MITICA SPIDER. The Neutral Beam Test Facility NBTF is a joint international effort to develop the neutral beam injector prototypes for ITER.

Ion Heating Experiments Using Perpendicular Neutral Beam Injection in the Large Helical Device

DEMO Concept Development and Assessment of Relevant Technologies. Physics and Engineering Studies of the Advanced Divertor for a Fusion Reactor

Additional Heating Experiments of FRC Plasma

Neutronics Experiments for ITER at JAERI/FNS

Fluctuation Suppression during the ECH Induced Potential Formation in the Tandem Mirror GAMMA 10

Huashun Zhang. Ion Sources. With 187 Figures and 26 Tables Э SCIENCE PRESS. Springer

Proton LINAC for the Frankfurt Neutron Source FRANZ

Modelling of JT-60U Detached Divertor Plasma using SONIC code

ONIX Results: Comparison of Grid Geometry (BATMAN - ELISE - Flat Grid)

Formation of High-b ECH Plasma and Inward Particle Diffusion in RT-1

Fast ion physics in the C-2U advanced, beam-driven FRC

1 AT/P5-05. Institute of Applied Physics, National Academy of Sciences of Ukraine, Sumy, Ukraine

Multicusp Sources for Ion Beam Lithography Applications

Magnetic field dependance of the plasma properties. in a negative hydrogen ion source for fusion

Electron Trapping in High-Current Ion Beam Pipes

Development of cable in conduit conductor for ITER CS in Japan

Development of Polarization Interferometer Based on Fourier Transform Spectroscopy for Thomson Scattering Diagnostics

Chopping High-Intensity Ion Beams at FRANZ

Development of a Lithium Beam Probe and Measurement of Density Pedestal in JT-60U

A Collisional Radiative Model for Caesium and Its Application to an RF Source for Negative Hydrogen Ions

Beam Extraction by the Laser Charge Exchange Method Using the 3-MeV LINAC in J-PARC )

Evolution of Bootstrap-Sustained Discharge in JT-60U

Simulation of Electron Behavior in PIG Ion Source for 9 MeV Cyclotron X. J. Mu 1, M. Ghergherehchi 1a, Y.H. Yeon 1, J.S. Chai 1

High Beta Discharges with Hydrogen Storage Electrode Biasing in the Tohoku University Heliac

Neutron Generators for Detection of Explosives and Illicit Materials

Axial symmetric open magnetic traps with depressed transversal losses of plasmas

Development of a Two-axis Dual Pendulum Thrust Stand for Thrust Vector Measurement of Hall Thrusters

Enhancement of an IEC Device with a Helicon Ion Source for Helium-3 Fusion

Alternative Neutralization Technique for a 40 Watt Quad Confinement Thruster

The ISIS Penning H - SPS and Diagnostic Developments at RAL

Imposed Dynamo Current Drive

Ion Implanter Cyclotron Apparatus System

Measurement of EEDF and Distribution of Primary Electron in a Bucket Ion Source

Double Null Merging Start-up Experiments in the University of Tokyo Spherical Tokamak

Measurement of beam power and profile for DNB on HT-7 tokamak

and expectations for the future

Materials for Future Fusion Reactors under Severe Stationary and Transient Thermal Loads

Contents Motivation Particle In Cell Method Projects Plasma and Ion Beam Simulations

PULSE-TO-PULSE TRANSVERSE BEAM EMITTANCE CONTROLLING FOR MLF AND MR IN THE 3-GeV RCS OF J-PARC

First plasma operation of Wendelstein 7-X

Progress Status of the Activities in EU for the Development of the ITER Neutral Beam Injector and Test Facility

PLASMA CONFINEMENT IN THE GAMMA 10 TANDEM MIRROR

Dense plasma formation on the surface of a ferroelectric cathode

GA A26686 FAST ION EFFECTS DURING TEST BLANKET MODULE SIMULATION EXPERIMENTS IN DIII-D

Beams and magnetized plasmas

Conceptual design of the beam source for the DEMO NBIs

Plan of Off-axis Neutral Beam Injector in KSTAR

Development of Key Technologies for Steady State Tokamak Reactor in JAERI

Heat Transfer Experiment and Simulation of the Verification Facility for High Power Rotating Tritium Target System

MITICA: il prototipo dell'iniettore di neutri da 1 MeV-22 MW per ITER

Advanced Tokamak Research in JT-60U and JT-60SA

Dependency of Gabor Lens Focusing Characteristics on Nonneutral Plasma Properties

Development of Target Injection and Tracking for IFE in Japan

Formation and Long Term Evolution of an Externally Driven Magnetic Island in Rotating Plasmas )

Development of Langmuir Probes on Divertor Cassettes in JT-60SA

Ion and Electron Heating Characteristics of Magnetic Reconnection in TS-3 and UTST Merging Startup Experiments

Beam-plasma interaction in the ITER NBI

Negative Ion Studies in an IEC Fusion Device

AP5301/ Name the major parts of an optical microscope and state their functions.

EX/C3-5Rb Relationship between particle and heat transport in JT-60U plasmas with internal transport barrier

PFC/JA NEUTRAL BEAM PENETRATION CONSIDERATIONS FOR CIT

Transcription:

1 FIP/2-5Rb Progress in long pulse production of powerful negative ion beams for JT-60SA and ITER A. Kojima 1), N. Umeda 1), M. Hanada 1), M. Yoshida 1), M. Kashiwagi 1), H. Tobari 1), K. Watanabe 1), N. Akino 1), M. Komata 1), K. Mogaki 1), S. Sasaki 1), N. Seki 1), S. Nemoto 1), T. Simizu 1), Y. Endo 1), K. Oasa 1), M.Dairaku 1), H.Yamanaka 1) and L. R. Grisham 2). 1) Japan Atomic Energy Agency, Naka, Ibaraki 311-0193, Japan 2) Princeton Plasma Physics Laboratory, Princeton, NJ 08543, USA E-mail contact of main author: kojima.atsushi@jaea.go.jp Abstract. Significant progress in the extension of pulse durations of the powerful negative ion beams has been made to realize the neutral beams injectors for JT-60SA and ITER. As for the long pulse production of high-current negative ions for JT-60SA ion source, the pulse durations have been successfully increased from 30 s at 13 A on JT-60U to 100 s at 15 A by modifying the JT-60SA ion source, which satisfies 70% of the rated beam current for JT-60SA. This progress is based on the R&D efforts about the temperature control of the plasma grid and uniform negative ion productions with the modified tent-shaped filter field configuration. As for the long pulse acceleration of high power density beams in the MeV accelerator for ITER, the pulse duration of MeV-class negative ion beams has been extended by more than 2 order of magnitude from the last IAEA conference. A long pulse acceleration of 60 s has been achieved at 70 MW/m 2 (683 kev, 100 A/m 2 ) by modifying the extraction grid with high cooling capability and high-transmission of negative ions. These results are the longest pulse durations of high-current and high-power-density negative ion beams in the world. 1. Introduction To proceed the JT-60SA [1] and ITER [2] projects successfully, negative-ion-based neutral beam injectors (N-NBIs) providing 10 MW D 0 beam for 100 s and 16.5 MW for 3600 s are necessary for actuators of the plasma heating/current drive. For the realization of these N- NBIs, the long pulse generations of the powerful negative ion beams of 500 kev, 22 A (130 A/m 2 ) and 1MeV, 40 A (200 A/m 2 ) are essential challenges [3]. In order to obtain these negative ion beams, lots of R&D efforts to improve negative ion productions [4-5], beam optics [6] and voltage holding capability [7] have been made in the world. In Japan Atomic Energy Agency (JAEA), high energy accelerations with multi-stage multiaperture accelerators were the priority of R&D activities [8]. In order to design the acceleration gaps for JT-60SA and ITER, the voltage holding capability of large-size multiaperture grids has been intensively investigated. Up to the last IAEA conference, the required beam energies for JT-60SA [9] and ITER [10] have been realized by modifying the accelerators based on the experimental database. After that, one of the remaining common issues for JT-60SA and ITER is the extensions of pulse durations. Toward this issue, the development of the key technologies for the long pulse production/acceleration of the negative ions has been concentrated by using the JT-60SA ion source and the MeV accelerator. This paper reports the recent activities and progresses on the development of the long-pulse negative ion beams toward the realization of JT-60SA and ITER N-NBIs. 2. Long Pulse Production of Negative Ions

2 FIP/2-5Rb FIG.1. Schematic views of the ion sources developed in JAEA. KAMABOKO-type arc-driven ion sources with three- and five-stage accelerators insulated by fiber-reinforced-plastic (FRP) insultators. The ion sources composed of plasma grid (PG), extraction grid (EXG) and acceleration grids. (a) JT-60SA negative ion source (b) MeV accelerator for ITER. In JT-60U, the longest pulse duration was 30 s with the beam current of 13 A [11], which was limited by the increase of a grid heat load due to a deviation from an optimum perveance condition. Since the JT-60U negative ion source was originally designed for short-pulse of 10 s with an inertially-cooled plasma grid (PG), the PG was overheated according to the pulse duration. This overheat of the PG resulted in a degradation of cesium (Cs) coverage on PG, namely negative ion current. To suppress this degradation for the long pulse production, the active control of the PG temperature has been developed for the JT-60SA ion source [12]. Moreover, in order to increase an extractable negative ions, the improvement of the beam uniformity has been tried by changing the magnetic field configuration of an arc discharge chamber to the tent-shaped filter configuration [13]. In order to overcome these issues, a teststand by using the JT-60SA ion source and power supplies was constructed in 2012. Since the 500 kv acceleration power supply is not available in this teststand, the long pulse production/extraction of 10 kev hydrogen negative ion beam are carried out. Fig. 1(a) shows the JT-60SA negative ion source which is basically reuse of that for JT-60U. Source plasmas are produced by filament-driven arc discharges in the FIG.2. (a) PG temperature control system for JT-60SA ion source. Maximum flow rate of the fluid is 60 L/min, the fluid temperature can be controlled up to 200 o C. (b) Photograph of the prototype PG.

3 FIP/2-5Rb KAMABOKO type chamber and confined with permanent magnets and the PG filter field [14]. The negative ions are mainly produced on a surface of Cs covered PG made of molybdenum. The PG composed of 5 segments with 1080 apertures in the extraction area of 110 cm x 45 cm. To receive 10 kev, 22 A beams for 100 s, a beam target was installed below the EXG, instead of the acceleration grids for this teststand. 2.1 Temperature Control of Plasma Grid Since the negative ion production strongly depends on the work function on the PG given by the coverage of Cs, the negative ion production can be controlled by the Cs coverage via the temperature of the PG. According to the previous studies [15], the temperature of the PG should be kept within 150-250 o C in order to obtain an optimum negative ion production. In order to extend the pulse duration with keeping the negative ion current, the active-control system of the PG temperature has been newly developed as shown in Fig. 2(a)(b). In this system, the PG is cooled and heated by the fluid, at the same time, a heat flux of maximum 0.1 MW/m 2 is removed by the fluid. In some candidates of the primary fluid, the fluorinated fluid (GALDEN HT-270) was applied in this system, which gives a big advantage of a high boiling point of 270 o C at 0.1 MPa with low viscosity [12]. The key parameter to design the system was the time constant of the temperature control of the PG. The saturation time of the PG temperature during the arc discharge was designed to be 7 s which was shorter than the decay time of the negative ion current which had been found to be about 30 s from the past experimental results. At first, for the proof-of-principle (PoP) of the long pulse production, the PG temperature control was applied to only 1 of 5 segments of the PGs. This PoP-PG was made of Cu and had 14 cooling channels with size of 3 x 6 mm 2 between 110 apertures corresponding to 10% of the extraction area. Fig. 3 shows that the saturation time of the PG temperature is decreased with the temperature increase of the fluid by improving the cooling capability due to the physical property of the fluid, and the design value of 7 s has been satisfied in the operational range of 150 o C-200 o C at a flow speed of 1.3 m/s. By applying the temperature control of the PG, the long pulse capability of the negative ion FIG.3. Time constant for the saturation of the PG temperature with the Proof-of-Principle-PG and the prototype PG for JT-60SA. Schematic view shows the definition of the saturation time. FIG.4. (a) Waveforms of the PG temperature with (proof-of-principle PG) and without (original PG) control. (b) Relation between pulse length and negative ion current density averaged in each segment.

4 FIP/2-5Rb FIG.5. (a) Schematic view of the concept of the original filter field (left) and calculated population profile of primary electrons (right) (b)the modified tent-shaped filter concept with 2D-mentionally rotated filter field (left) and its population profile production has been significantly improved as shown in Fig 4(a)(b). This improvement implies the success of the sustainment of the Cs coverage on the PG. As a results, the sustainable current density for 100 s was 5 times higher than the original inertially-cooled PG. Based on the results, 5 segments of the prototype PGs having 1080 aperture corresponding to 100% of the extraction area have been developed. The PGs were made of molybdenum for 3 segments, oxygen free copper for 2 segments. 10 cooling channels with the same size as PoP- PG are arranged between each aperture lines. Due to the size limitation between apertures, the thickness of the PG was increased from 6 mm to 9mm, and the shape of the apertures was modified to the 75 o taper-type. Although the configuration of the PG aperture was varied from the original one, the extraction of the required current density of 130 A/m 2 has been confirmed by the dedicated experiments for negative ion extractions from various aperture shapes. Since the time constant of the prototype PG was designed to be same as the PoP-PG, the similar saturation time of the PG temperature has been obtained as shown in Fig. 3, which is also enough shorter than the decay time of the negative ions. By using the prototype PG, the long pulse production has been tried with the prototype PG. 2.2 High Current Production with Uniform Negative Ion Profile In order to realize high-current longpulse production, one of remaining issues is a uniformity of beam profile. Since the beam current is determined by ensemble of each beamlets, each beamlets should be produced and accelerated in the same focusing property. If un-uniform plasma is FIG.6. The temperature increase (ΔT) profile on the beam target at 45mm below the EXG. Beam pulse duration is 1 s. ΔT is proportional to the bean intensity. Cooling pipes are arranged transversely.

5 FIP/2-5Rb produced, lower beam current with higher grid heat load is expected due to the un-uniform negative ion extraction/acceleration. In JT-60U, past experimental results suggested that the magnetic field configuration with the PG filter field caused the low beam uniformity of 70%, where the uniformity is defined as the ratio of the beam current and the estimated beam current where maximum current density is uniformly assumed ( I/ jmax ds). In order to increase the negative ion current by improving the plasma uniformity, the tent-shaped filter configuration was tested, which had been developed in JAEA by using the small ion source [16]. From the past results [13], the key factor for the beam uniformity was found to be a uniform plasma production with control of the magnetic drift for primary electrons emitted from filaments. The calculated electron population profile for the original configuration shows the localized profile due to one way grad-b drift by the PG filter field as shown in Fig.5(a). In order to resolve the localization of the primary electron, the tent-shaped filter concept has been designed for the JT-60SA ion source as shown in Fig. 5(b). By adjusting the permanent magnets from asymmetry to axial symmetry, the orbits of the primary electrons were designed to go around the magnetic filter by the rotational grad-b drift. As a result, by applying the tent-shaped filter concept, the uniformity of the extracted beam profile has been significantly improved from 68% to 83% as shown in Fig 6, where 32 A negative ions has been produced. Moreover, 22 A negative ion has been obtained only from the 3 segments of Seg.2~4. Because the extractable negative ion current for this configuration become 1.14 times higher than the original one at the same condition, the negative ion current of 22 A has been realized at the arc power of 200 kw, the extraction voltage of 7.4 kv and the PG temperature of 250 o C. Although the co-extracted electrons accompanied with the negative ion extraction was increased from 20% to 50% of the total extraction current due to the reduction of the filter field strength from 0.7 to 0.4 mtm, this heat flux was below the allowable level of the cooling capability of the EXG (1 MW/m 2 ). The highcurrent production for JT-60SA has been realized by this modified tentshaped filter concept. 2.3 Long Pulse Production of High Current Negative Ions for JT-60SA In 2013, the long pulse production of 2A negative ions has been demonstrated with the PoP-PG from 10% extrication area [12]. In 2014, the prototype PG having 100% extraction area and the tent-shaped filter configuration has been installed in the JT-60SA ion source. By utilizing these FIG.7. (a) The progress of the long pulse production started from 2013 with proof-of principle PG and prototype PG for the PG temperature control. (b) Progress of the achieved performance required for JT-60SA.

6 FIP/2-5Rb FIG.8. (a) 3D beam analysis and thermal analysis for the JT-60 type EXG and ESG. (b) for the long pulse EXG. new techniques, the long pulse production of high current negative ions has been tried. As a result, 15 A negative ions with pulse duration of 100 s has been achieved for the first time as shown in Fig.7(a). This performance has reached to 70% of the required current for JT-60SA and fulfil the required pulse duration which is 3 times longer than the result on JT-60U. The long pulse production is going on in the teststand. Fig.7(b) shows the progress of a performance diagram for the JT-60SA N-NBI. At present, the long pulse capability has been significantly improved. Therefore, long pulse accelerations with high-current negative ion beams are expected in JT-60SA operation. Moreover, for ITER, this R&D result contributes to the PG design of the ITER ion source in terms of the required time constant for the high-current long pulse production. 3. Long pulse acceleration of high power density beams with improved extractor To realize the long pulse acceleration of the high-power density MeV-class beam for ITER, the reduction of the heat load and the heat removal from acceleration and extraction grids are essential techniques. Up to the last IAEA conference, the reduction of the heat load by controlling the beam trajectories to compensate the beam deflection was the key issue for the acceleration of ITER relevant beams [10]. After that, one of remaining issues is the heat removal of the co-extracted electrons from the EXG. Because the EXG has magnets to deflect the co-extracted electrons, the operational temperature is strongly restricted by the demagnetization temperature of the SmCo-magnets about 200 o C. In the MeV accelerator (Fig. 1(b)), since the EXG of JT-60 type was used, the pulse duration of the ITER relevant high power density beams was limited to 0.4 s. This was

7 FIP/2-5Rb because an allowable heat flux of the EXG was limited to 1MW/m 2 for JT-60 type where 20% of the electron current ratio was assumed. However, the heat flux of the coextracted electrons for ITERrelevant beam was estimated to be over 2MW/m 2 due to higher current density and higher electron ratio of 50% were assumed. Therefore, a new EXG has been developed for FIG.9. (a) Hydrogen negative ion current for the JT-60 and the demonstration of the long ITER type EXG. (b) Grid heat loads on the acceleration grids pulse acceleration of highpower density beams for ITER [17]. from A1G to GRG. The key parameters for the long pulse EXG are the cooling capability for the co-extracted electrons and the transmission of the extracted negative ions. In order to improve the cooling capability, the position of water-cooling channels was moved near the electron receiving area as shown in Fig. 8(a)(b). Moreover, the cross section of the cooling channels was enlarged by 3 times than that of JT-60 type. As a result, the maximum temperature of the EXG has been reduced from 257 o C to 104 o C in 3D thermal analysis. In addition, the configuration of the EXG has been re-designed to enhance the transmission of the negative ions [18]. In the JT-60 type, a clearance of 0.4 mm between the beam outline and the electron suppression grid (ESG) was marginal to increase the beam current density. In this case, the direct interception of the negative ions to the ESG results in both of the low negative ion current and the production of the secondary electron flux to downstream grids. Therefore, the aperture size and its displacement of the EXG-ESG configurations has been modified as shown in Fig. 8(b). As a result, the clearance is increased to 1.4 mm in 3D beam analysis, which indicates the higher transmission is expected even in higher current density. The long pulse acceleration has been tested in the MeV accelerator with the developed EXG-ESG from 2014. As a result, the negative ion current has been increased by 10% at the same condition as shown in Fig. 9(a), which indicate the improvement of the transmission in high-arc-power high-current condition. The higher transmission also affects to the reduction of the grid heat on the upstream acceleration grids of A1G-A3G as shown in Fig.9(b). Totally the grid heat load has been reduced from 17% to 12%, which is considered to be the effect of the suppression of secondary electrons production due to the direct interception of the negative ions to the ESG. This level of the grid heat load is enough lower than the ITER requirement (25%) even if assuming the increase of the stripping loss in the ITER accelerator. FIG.10. Progress of the long pulse accelerations for high-power density beams in the MeV accelerator.

8 FIP/2-5Rb At present, long pulse acceleration of 700 kev, 70 MW/m 2 beam for 60 s has been achieved as shown in Fig. 10. Although the pulse duration of 60 s is limited by the power supplies, no limitation has been observed to increase the power density. 4. Summary Toward the realization of JT-60SA and ITER N-NBIs the key technologies to realize the high-current long-pulse negative ion beams have been developed to overcome the common issues. As for the long pulse production of high current beams, the PG temperature control system successfully demonstrated the sustainment of the negative ion production. In addition, the beam uniformity has been improved to enhance the negative ion current. The improvement of the uniformity also contributes the reduction of the grid heat load. Since the JT-60SA ion source has been upgraded by these techniques, the negative ion production of 15 A for 100s has been achieved, which has reached to 70% of the target current. As for the long pulse acceleration, the EXG with high cooling capability and high transmission has been developed to accelerate ITER relevant power density beams. By applying the developed EXG, the long pulse acceleration of 70 MW/m 2 beam for 60 s has been obtained successfully. This pulse duration was 2 orders higher than that for the last IAEA conference and has reached to the limit of the present power supplies. Both of the obtained experimental results of the long pulse production/acceleration are the first breakthroughs to realize the long pulse production/acceleration of the high-current/highpower-density negative ion beams in the world. References [1] ISHIDA, S., et al., Proc. of the 23rd Fusion Energy Conf., 2010, OV/P-4. [2] IKEDA, K,'Progress in the ITER Physics Basis', Nucl. Fusion 47 (2007) S1. [3] IKEDA, Y.,et al.,ieee Trans. Plasma Sci.36, 1519 (2008). [4] TSUMORI, K., et al., AIP Conference Proceedings 1515 (2013) 149. [5] FANTS, U., et al., AIP Conference Proceedings 1515 (2013) 187. [6] KASHIWAGI. M., et al., Nucl. Fusion 49 065008 (2009). [7] KOJIMA, A, et al., Rev. Sci. Instrum. 83, 02B117 (2012). [8] KOJIMA, A, et al., Nucl. Fusion 51(2011) 083049. [9] HANADA, M, et al., Proceeding of IAEA Fusion Energy Conference 2012, FTP/P1-18. [10] INOUE, T, et al., Proceeding of IAEA Fusion Energy Conference 2012, FTP/1-2. [11] HANADA, M., IAEA Fusion Energy Conference 2008, FT/P2-27. [12] KOJIMA, A, et al., Rev. Sci. Instrum. 85, 02B312 (2014). [13] YOSHIDA, M, et al., Rev. Sci. Instrum. 85, 02B314 (2014). [14] KURIYAMA, M., et al., Fusion Eng. Des. 26 (1995), p. 445. [15] KASHIWAGI, M, et al., Rev. Sci. Instrum. 73, 964 (2002). [16] TOBARI, H, et al., Review of Scientific Instruments 79 (2008) 02C111. [17] KASHIWAGI, M, et al., Rev. Sci. Instrum. 85, 02B320 (2014). [18] UMEDA, N, et al., Rev. Sci. Instrum. 85, 02B304 (2014).