SWARCO LIMBURGER LACKFABRIK GmbH Road Marking Systems. 1-component Afterglow paint system TECHNICAL INFORMATION

Similar documents
MATERIAL SAFETY DATA SHEET

RoHS. Specification CUD8DF1A. Drawn Approval Approval. 서식 Rev: 00

*These are the vinyl for MAX Bepop Cutting/printing machines. We have 100mm (4in) and 200mm(8in) width models available in North America.

Dynasylan SIVO 110. Description. Product Information. SIVO SOL Technology for coating systems

RoHS. Specification CUD8AF1C. 서식 Rev: 00

P8D137. Features. Applications. Power UV LED Series is designed for high current operation and high flux output applications. Super high Flux output

P8D1 P8D1. Features. Applications. Power UV LED Series is designed for high current operation and high flux output applications.

Safety in the Chemistry Laboratory

F50360 F Features. Applications

3. Chemical Hygiene Plan: Laboratory Standard Operating Procedures. A. Laboratory Specific Information and Signatures

J0NES-BLAIR PAINT MANUFACTURERS OF QUALITY PAINT SINCE 1928 INDUSTRIAL COATINGS (High Performance)

Hazard Communications

Hazardous Communication. Hazard Communication. Hazardous Communication. Hazardous Communication. Hazardous Communication. Hazardous Communication

Specification SPW08F0D

LED light engine / OLED LED compact. Umodule STARK DLE CLASSIC STARK DLE 82,8 54,4. Ordering data

Objective: Science Classroom Laboratory Safety

Specification SSC-SZ5P

Underlayment. bonded impact sound insulation

Technical Data Sheet. Pb Free. Specification GR101 SSC. Customer. Rev. 02 January 서식번호 : SSC- QP (Rev.0.

Z-POWER LED Series. Technical Datasheet for F50380 SEOUL SEMICONDUCTOR

INFRARED THERMOMETER TM0819

TITLE: Surface Decontamination of Iodine Compounds (Potassium Iodide (KI)) by DeconGel TM

Why we will apply Phosphorescent Pigment from NIC. Make safe and recycling-oriented society by using Phosphorescent Pigment

tel.: , fax: , mobile:

Hazard Communication Policy

WHAT S WRONG WITH THIS PICTURE?

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

XZ Features. Description. Applications

L u m b e r M e l a m i n e H a r d w o o d P l y w o o d A r c h i t e c t u r a l P a n e l s C o l o r e d C a u l k P a r t i c l e B o a r d E

Power LED I TECHNICAL DATA

OHD L-14 METHOD OF TEST FOR DETERMINING THE SPECIFIC GRAVITY AND UNIT WEIGHT OF COMPACTED BITUMINOUS MIXTURES

Applications of Neuburg Siliceous Earth in Coatings and Related Systems. We supply material for good ideas

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-3 EM umodule SPOT PHASED OUT NTC NTC LED + LED + LED EM LED EM

Specification SSC-SZ5M

N) manual. Biomaster Operating manual

PHASED OUT. LED light engine / OLED LED compact. Module SLE G4 6mm R SNC, SLE G4 10mm R SNC China domestic Modules SLE ESSENCE

SECTION AGGREGATE OR GRANULAR SUBBASE

LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC China domestic umodule SLE ESSENCE

Specification YGHR411-H

Power LED I TECHNICAL DATA

Borchers Rheological Additives for waterborne coating systems. Borchi Gel

ACRIFIX. Adhesives and Auxiliaries

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Standard Glossary of Packaging Inks and Coatings Terms

INFRARED THERMOMETER Model : TM-959

SEOUL SEMICONDUCTOR CO., LTD.

Specification LW514. [Preliminary] CUSTOMER SSC. Rev. 00 October Document No. : SSC-QP (Rev.00)

Liquid Polybutadienes and Derivatives

Specification LW514. Drawn Approval Approval. Rev. 02 December 서식번호 : SSC-QP (Rev.00)

Individual Laboratory Safety & Chemical Hygiene Plan

Nanoparticle Safety Program

Specification LY530. Drawn Approval Approval. Rev. 08 December 서식번호 : SSC-QP (Rev.00)

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm TINGE R SNC umodule SLE ESSENCE

Material Safety Data Sheet acc. to ISO/DIS 11014

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 17mm R SNC umodule SLE ESSENCE

Retroreflective Prismatic License Plate Film

Specification KWT803-S

2.8-1 SCIENCE EXPERIMENTS ON FILE Revised Edition. Dew Formation

GUIDELINES OF PROCUREMENT - CHEMICALS FOR RESEARCH CHEMICAL MANAGEMENT CENTRE

Specification LR530 SSC CUSTOMER. Rev. 07 January acriche.com. Document No. : SSC-QP (Rev.00)

Introduction. Sample kit content

FLUXA-CONTROL: AN AUTOMATED MONITORING OF FLUORESCENT PARTICLES IN MAGNETIC PARTICLE TESTING

LED light engines LED compact. Module SLE G7 ADV Modules SLE ADVANCED

Copyright Materials PROSOCO, Inc 2011

8.6 Product data sheet

Micro Volume QuEChERS kit

Ionizing Radiation Awareness (Non-User)

Material Safety Data Sheet acc. to ISO/DIS 11014

Specification LY521. <080924> Rev. 0.3 Document No. : SSC-QP (Rev.00) Drawn Approval Approval. Rev. 00 December

Technology offer: Environmentally friendly holographic recording material

SPEC NO: DSAJ6327 REV NO: V.1 DATE: JUL/31/2009 PAGE: 1 OF 8 APPROVED: WYNEC CHECKED:

Safe Use of Pyrophoric/Water Reactive Materials

RADIATION SAFETY GUIDELINES FOR NON-USERS

Thermal Imaging Best Practices: The Measuring Object. Page 2

PREFERRED RELIABILITY PRACTICES. Practice:

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-2 umodule SPOT C.PHASED NTC

HPLC Columns. STANDARD Pullulan P-82 MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia

SPECIFICATIONS OF CITILIGHT 1 / Scope of Application These specifications apply to chip type LED lamp, CITILIGHT, model CL-822 -U1D-T.

Features Instant light (less than 100ns) Lead free reflow soldering RoHS compliant Cool beam, safe to the touch

Material Safety Data Sheet acc. to ISO/DIS 11014

Material Safety Data Sheet acc. to ISO/DIS 11014

LOW E SATINÉ 5500 LOW E

DARKROOM HAZARDOUS WASTE MANAGEMENT GUIDE

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-2 umodule SPOT C.PHASED NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-3 umodule SPOT PHASED OUT 46,5 39,5 35,5 NTC NTC LED + LED 8,5 4,5 8,5

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-3 EM umodule SPOT PHASED OUT 39,5 35,5 NTC NTC

QuickZyme Total Protein Assay (to be used with acid hydrolyzates)

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE

PRETREATMENT TECHNICAL DATA SHEET IRON PHOSPHATE CLEANER COATER / CONVERSION COATING PRODUCT DESCRIPTION

MATERIAL SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006

SCREEN LOW E SATINÉ 5500 LOW E

RISK RATING SAFE WORK METHOD STATEMENT 1 HIGH 2 MEDIUM 3LOW. I approve the use of this Safe Work Method Statement: NAME: POSITION: Department Manager

Presented at the 6 th Strassenkonferenz, Budapest 1988

Power LED I TECHNICAL DATA

SCREEN LOW E SATINÉ 5500 LOW E

Specification STW8T36B

8.1 Product data sheet

1 PRODUCT AND COMPANY IDENTIFICATION. Manufacturer. Description: Natural occuring clay mineral SDS. GHS Safety Data Sheet. PROFILE Products, LLC

Specification LR530. Drawn Approval Approval. Rev. 08 December Document No. : SSC-QP (Rev.00)

Transcription:

1-component Afterglow paint system TECHNICAL INFORMATION

1-component Afterglow paint system Art.-No.: 8129016 white, 1-comp. Afterglow primer Art.-No.: 8121111 yellow-green, 1-comp. Afterglow paint Art.-No.: 8120000 transparent, 1-comp. UV-clear varnish Special applications afterglow systems Version: 2016-06-01 CONTENTS 1 Main characteristics / Fields of application... 3 2 Technical Data... 3 3 Efficacy of afterglow markings... 4 4 Processing instructions... 4 4.1 Preparation of material and application technique... 4 4.2 Optimizing of application properties... 5 5 Surfaces / pretreatment... 5 5.1 General information... 5 5.2 Concrete and cement-bound surfaces... 5 5.3 Bituminous surfaces... 5 5.4 Cobbled pavement... 5 5.5 Floor coatings... 6 5.6 Other surfaces... 6 6 Application techniques... 6 E. info.limburgerlackfabrik@swarco.com, www.swarco.com/limburgerlackfabrik 2/6

1 Main characteristics / Fields of application 1-component Afterglow paint system... is a three-layered marking system consists of a 1-component primer, 1-component afterglow paint and a 1-component UV-clear varnish and belongs to the group of aromatic-free, solvent containing 1-component paints can be incited by UV radiation as well as by white daylight or artificial light, in the dark afterglow paint is visible by its afterglow properties (emission of light), the special afterglow pigments are free of phosphor, radioactive substances or other toxic chemicals. Incitation and emissions can be repeated without limitation suitable for near-ground optical safety guide systems and identification of emergency exit routes in tunnels, staircases, parking garages, factories, shopping centers, tunnels etc. when a power blackout or fire with formation of smoke takes place supplemented existing emergency light systems invisible by smoke marking's good luminescence does not only show the direction of evacuation routes, but also make staircases, obstacles, doors etc. visible product is not suitable for areas with car traffic impact; applicable on horizontal surfaces with low pedestrian traffic density only or on vertical surfaces (e.g. walls) developed for inside rooms with intensive lights, the afterglow paint should be applied close to those light sources suitable for bituminous surfaces (e.g. mastic asphalt, asphaltic concrete), not suitable for floor coatings tested and approved at Federal Institute for Materials Research and Testings (BAM, Berlin) according to DIN 67510 part 1 (longtime afterglow products) suitable for airspray technique (for airless machines: in advance tests are recommended). 2 Technical Data Three-layered system first layer second layer third layer Product Primer for UV clear varnish for 1-component Afterglow paint 1-component Afterglow paint 1-component Afterglow paint Art.-No.: 8129016 8121111 8120000 Standard colors white yellow-green transparent Density 1.57 kg/l +/- 0.1 1.13 kg/l +/- 0.1 0.96 kg/l +/- 0.03 Thinner on request: Thinner for HS-paint (Art.-No.: 3080) Thinner for cleaning Special cleaner for marking machines Art.-No.: 3086 Next application after approx. 5 15 min. (must not be sticky but dust-dry) approx. 10 25 min. (must not be sticky but dust-dry) approx. 10 15 min. Drying time / Overrollability approx. 1 hour after last application (must not be sticky)* Wet layer thickness to be applied Theoretical consumption approx. 200 µm - 400 µm make sure: evenly and all over coverage approx. 0.314 kg/m² (0.20 l/m²) approx. 0.628 kg/m² (0.40 l/m²) min. 100 µm - max. 600 µm depending on requested afterglow time span. Thickness more than 300µm needs application with two layers approx. 0.11 kg/m² (0.102 l/m²) to approx. 0.68 kg/m² (0.6 l/m²) min. 60 µm max. 100 µm spray in two applications approx. 0.058 kg/m² (0.062 l/m²) to approx. 0.096 kg/m² (0.103 l/m²) E. info.limburgerlackfabrik@swarco.com, www.swarco.com/limburgerlackfabrik 3/6

Standard packaging Identification Storage stability Processing temperature min. + 5 C 2.5l - tin foil container 5.0l - tin foil container 10.0l - tin foil container Surface temperature + 5 C to + 45 C Relative humidity 2.5l - tin foil container 10.0l - tin foil container 2.5l - tin foil container 10.0l - tin foil container The regulations and instructions concerning appropriate transport, handling, storage, first aid measures, toxicology and ecology are stated in our material safety data sheets! The instructions stated on the product label and in the MSDS must be followed 1 year in unmixed, sealed original packaging and sheltered from frost and direct sun exposure max. 75% (dew point spreadsheet has to be regarded) * In general the markings` work-on stability must be checked before exposing them to traffic impact 3 Efficacy of afterglow markings Influencing factors affecting afterglow properties: Quality of the afterglow pigment Line width Effective source of light enables a proper incitation for the whole spectral range charging time quality of the white primer layer thickness Optical properties tested at BAM* - Afterglow paint system according to DIN 67510-1 - sample Wet film thickness µm 1.layer 2.layer 3.layer Test April 2010 400 400 60 Test June 2005 400 600 60 luminance mcd / m² after 1 min 10 min 30 min 60 min 2880 1736 ecay time ** in min. * BAM Bundesanstalt für Materialforschung und prüfung (Berlin) or: Federal Institute for Materials Research and Testings ** decay time until luminance amount to 0,3 mcd /m² 312 219 90 68 39 30 2700 2450 4 Processing instructions 4.1 Preparation of material and application technique All products of the afterglow paint system must be homogeneously stirred in their original container before processing by using an appropriate stirring device. The application and drying properties of the material depend on temperatures, of air- material and surface. Proper storage conditions improve application conditions partly. Theoretical material consumption is stated in: Table Theoretical material- and drop-on consumption on our homepage The exact machine adjustments have to be done according to the manufacturers` instructions. Layer thickness has to be evenly distributed to get consistent afterglow properties. Cleaning of machine (paint tank, hoses, tools) must takes place before curing occurs with Special cleaner for marking machines Art.-No.: 3086. E. info.limburgerlackfabrik@swarco.com, www.swarco.com/limburgerlackfabrik 4/6

4.2 Optimizing of application properties The 1-component afterglow paint system in its delivery state is ready for processing. In general it is not necessary to add thinner but for optimizing the material`s spray properties approx. 2% Thinner for high solid paints (Art.-No.: 3080) can be added. Thinner recommended by the manufacturer must be used only. 5 Surfaces / pretreatment 5.1 General information The surface must be dry, clean free from grease, oil and loose gravel and other contaminations. The surface and potential existing old markings must be checked for their carrying capacity and compatibility with material to be applied. In case of doubt, test applications and adhesion tests are required. Ideally, old markings should be removed with appropriate mechanical procedures. If the 1-component Afterglow paint system is applied onto old markings, drying times could be prolonged. Attention: 1-comp. Afterglow paint system is not suitable for large scale asphalt markings. 5.2 Concrete and cement-bound surfaces The pavement components that prevent good bonding, especially on new concrete, as fine mortar layer, concrete slurries, concrete after-treatments as setting retarders, paraffin, impregnations on silicate basis etc. must be appropriate removed (e.g. with high pressure waterjet, fine millcut or similar). We recommend conducting test applications in case of doubt communicate concerns in writing about paint bounding properties. On new washed concrete surfaces (with grit) poor bonding properties may occur, not caused by marking paint quality. Therefore we recommend applying test markings. When applying the paint to concrete or cement-bound surfaces, the formation of bubbles is likely to occur. In order to prevent formation of bubbles the concrete - Primer for 1-component Afterglow paint - should be used blended 1:1 with Thinner for HS-Paints (Art.-No.: 3080) and sprayed with approx. 150 µm wet film thickness. Once dried, a second, undiluted layer can be applied. The humidity of concrete must not exceed 4% during the marking job. 5.3 Bituminous surfaces Any loose components such as chippings must be removed. Flux oils of new bituminous surfaces are detrimental to bonding of markings and may lead to discolouration. Since these oils are not removable mechanically, the surface should be applied with 1-comp. Primer for Afterglow paint and after 4 6 weeks waiting time conduct test markings (tests for adhesive properties and discoloration). Furthermore has to be regarded: new bituminous surfaces applied inside car parks and industrial buildings are not as good compacted as road asphalt. Therefore underneath the marking or sidewards the marking cracks / chippings may occur. 5.4 Cobbled pavement Natural, artificial and compound stone pavements are loose surfaces that move. Basically they are no suitable surfaces for the 1-component Afterglow paint system. No guarantee is given in cases of: crack formation, chippings caused by the movement of pavement parts, poor marking bonding (e.g. natural or artificial stones), penetration of moisture and wear of marking. Test markings are always necessary. E. info.limburgerlackfabrik@swarco.com, www.swarco.com/limburgerlackfabrik 5/6

5.5 Floor coatings For markings on floor coatings, SWARCO LIMBURGER LACKFABRIK s indoor marking products should be used. The 1-component Afterglow paint system is not suitable for floor coatings. 5.6 Other surfaces Inside building`s further surfaces are applied (e.g.: PVC, wood, chipboards). Test markings are mandatory. The 2-component Afterglow paint system may be an option. Metal surfaces are no suitable surface for the 1-component Afterglow paint system. 6 Application techniques With marking airspray machines (in advance tests are necessary when using airless machines) or with hand spray gun or roller. Application of the 1-component Afterglow paint system is to be conducted in the following sequence: 1. 1-component Afterglow primer apply evenly 2. 1-component Afterglow paint apply evenly, gives the afterglow effect, depending on wanted thickness: two applications are necessary 3. 1-component UV clear varnish for 1-component Afterglow paint protects afterglow paint against dirt and wear and prolonged life time The above mentioned layer thicknesses and number of stated spray operations have to be applied in order to get the optimal afterglow properties. Afterglow paint thickness can be modified between 100 µm to max. 600 µm depending on requested afterglow effect. Regard waiting times stated in the spreadsheet. The 1-component UV-clear varnish for Afterglow paint needs enough time for drying. Otherwise varnish`s surface gets soiled. i i Please consider our General Terms and Conditions and the general notes of the Technical Information Sheet! No liability is accepted for any errors! The information is provided to our best knowledge and experience. This information is, however, no warranty for any properties of the material. We provide this information without obligation, also regarding the rights of third parties. The user has to make sure that the material is appropriate for the respective application. E. info.limburgerlackfabrik@swarco.com, www.swarco.com/limburgerlackfabrik 6/6