Application of the EQP and EQS mass spectrometers to time resolved studies in ion beam and plasma processes

Similar documents
vacuum analysis plasma diagnostics surface science gas analysis

Hiden HPR60 Molecular Beam Mass Spectrometer System

Plasma Diagnostics Introduction to Langmuir Probes

Hiden SIMS Secondary Ion Mass Spectrometers. Analysers for surface, elemental and molecular analysis

Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis

Hiden EQP Systems. High Sensistivity Mass and Energy Analyzers for Monitoring, Control and Characterization of Ions, Neutrals and Radicals in Plasma.

FIB - SIMS. Focussed Ion Beam Secondary Ion Mass Spectrometry.

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

ICP-MS. High Resolution ICP-MS.


Extrel is widely respected for the quality of mass spectrometer systems that are

Pressure & temperature sampling options for Hiden gas analysis systems

DS0026 Dual High-Speed MOS Driver

CATALYSIS & THERMAL ANALYSIS

Mass Spectrometer A Comparison of Positive and Negative Ion RGA Methods

Hiden EQP Applications

Plasma parameter evolution in a periodically pulsed ICP

SNMS. SNMS Applications. Combined SIMS and SNMS

Supplementary Figures

Comments on the possible observation of d-d fusion in sonoluminescence (Reference-31 in Taleyarkhan et al. [2002] 1 )

High power impulse plasmas for thin film deposition

High Sensitivity Mass and Energy Analysers for Monitoring, Control and Characterisation of Ions, Neutrals and Radicals in Plasma

RESIDUAL GAS ANALYSIS MASS SPECTROMETERS FOR RESIDUAL GAS ANALYSIS - RGA

Ablation Dynamics of Tin Micro-Droplet Target for LPP-based EUV light Source

Using Alba with the FemtoFiber laser by Toptica for 2-photon quantitative imaging

Mass Spectrometers. for Surface Analysis SURFACE ANALYSIS

SURFACE ENGINEERING MASS SPECTROMETERS FOR THIN FILMS, PLASMA AND SURFACE ENGINEERING

Relative Sensitivity RS Measurements of Gases

TECHNIC A L WORK ING GROUP ITWG GUIDELINE ON SECONDARY ION MASS SPECTROMETRY (SIMS)

Autoresonant Ion Trap Mass Spectrometer The RGA Alternative

ORTEC. Counters/Ratemeters/ Multichannel Scalers. Choosing the Right Counting Solution. The Basic Functions of Counting Systems

OPTICAL DETECTION OF SLOW EXCITED NEUTRALS IN PLASMA- ASSISTED EXCIMER LASER ABLATION

Transient measurements using thermographic phosphors

The ESD5451R is available in DFP1006-2L package. Standard products are Pb-free and Halogen-free. Circuit diagram

AN-1080 APPLICATION NOTE

Hiden Analytical Ltd

THIN FILMS, PLASMA & SURFACE ENGINEERING. Mass Spectrometers. for Thin Films, Plasma & Surface Engineering

SIZE-SELECTED AEROSOL FILTER ANALYSIS USING ELECTROSTATIC CLASSIFICATION AND LIBS

Lab #10: Design of Finite State Machines

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Sciences

Extrel Application Note

Cesium Dynamics and H - Density in the Extended Boundary Layer of Negative Hydrogen Ion Sources for Fusion

MEASUREMENT OF TEMPORAL RESOLUTION AND DETECTION EFFICIENCY OF X-RAY STREAK CAMERA BY SINGLE PHOTON IMAGES

Mass Analyzers. Ion Trap, FTICR, Orbitrap. CU- Boulder CHEM 5181: Mass Spectrometry & Chromatography. Prof. Jose-Luis Jimenez

ACTIVE SEPARATION CONTROL ON A SLATLESS 2D HIGH-LIFT WING SECTION

Probing and Driving Molecular Dynamics with Femtosecond Pulses

Behavior and Energy States of Photogenerated Charge Carriers

Foundations of Modern Physics by Tipler, Theory: The dierential equation which describes the population N(t) is. dn(t) dt.

Visualization of Xe and Sn Atoms Generated from Laser-Produced Plasma for EUV Light Source

A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling

Output intensity measurement on a diagnostic ultrasound machine using a calibrated thermoacoustic sensor

SC1301A/B. 2A High Speed Low-Side MOSFET Driver in SOT-23 POWER MANAGEMENT. Applications. Typical Application Circuit

Ultrafast Dynamics and Single Particle Spectroscopy of Au-CdSe Nanorods

Beam Diagnostics. Measuring Complex Accelerator Parameters Uli Raich CERN BE-BI

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

2.3 Deflection Plates

MM54C221 MM74C221 Dual Monostable Multivibrator

HiSPARC Detector - Detector Station

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Chemistry Instrumental Analysis Lecture 35. Chem 4631

Plasma Spectroscopy in ISTTOK

Novel Plastic Microchannel-Based Direct Fast Neutron Detection

Photoluminescence Spectrometer (FLS980)

MILITARY SPECIFICATION MICROCIRCUITS, DIGITAL, BIPOLAR, TTL, MONOSTABLE MULTIVIBRATORS, MONOLITHIC SILICON

ORTEC. Time-to-Amplitude Converters and Time Calibrator. Choosing the Right TAC. Timing with TACs

MM74C912 6-Digit BCD Display Controller Driver MM74C917 6-Digit Hex Display Controller Driver

Fundamental investigation on CO 2 laser-produced Sn plasma for an EUVL source

Catalysis CAPABILITIES

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

arxiv: v1 [physics.ins-det] 29 Jun 2011

CHAPTER D4 ORTHOGONAL TIME OF FLIGHT OPTICS

The Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

Imaging gold nanoparticles in mouse liver by laser ablation inductively coupled plasma mass spectrometry

Multi-diagnostic comparison of femtosecond and nanosecond pulsed laser plasmas

channel system which covers both sides of the laser line. Coverage on both sides of the spectrum allows for

1. The range of frequencies that a measurement is sensitive to is called the frequency

Electron Temperature Modification in Gas Discharge Plasma

9A HIGH-SPEED MOSFET DRIVERS

Development of portable neutron generators based on pinch and plasma focus discharges 1

Additional Analytical Methods. Detrital zircon samples were collected from nine fine-, medium-, and coarse-grained

Accelerators and Lasers In Combined Experiments Susan Smith Daresbury Laboratory

X-Ray Measurements of the Levitated Dipole Experiment

High Resolution Optical Spectroscopy

arxiv: v2 [physics.ins-det] 17 Jun 2014

Laser heating of noble gas droplet sprays: EUV source efficiency considerations

Figure 1. Decay Scheme for 60Co

SERIALLY PROGRAMMABLE CLOCK SOURCE. Features

Abstract Submitted for the DPP99 Meeting of The American Physical Society

MM54HC73 MM74HC73 Dual J-K Flip-Flops with Clear

Plasma diagnostics of pulsed sputtering discharge

ICP-Mass Spectrometer

onlinecomponents.com

High Voltage Capacitors Designed to Avoid Catastrophic Failure Modes

Plasma Accelerator for Detection of Hidden Objects by Using Nanosecond Impulse Neutron Inspection System (NINIS)

Development of an Alternating Electric Field Accelerator for Laser-Ablation Plasma Acceleration

A novel sputtering technique: Inductively Coupled Impulse Sputtering (ICIS)

DATA SHEET. HEF4031B MSI 64-stage static shift register. For a complete data sheet, please also download: INTEGRATED CIRCUITS

Introduction to the Q Trap LC/MS/MS System

Quality Assurance. Purity control. Polycrystalline Ingots

CD4029BM CD4029BC Presettable Binary Decade Up Down Counter

Transcription:

PLASMA DIAGNOSTICS EQP APPLICATION NOTES Application of the EQP and EQS mass spectrometers to time resolved studies in ion beam and plasma processes EQP and EQS mass spectrometers can be used to study repetitive transients in ion beams or plasma afterglow. Mass and energy spectra of ions can be determined in a specified time window synchronised to the transients. Time windows can be as short as 1 microsecond. Applications include negative ion plasma analysis, time resolved measurements in pulsed plasmas and in the plume of laser ablation processes, and signal to noise ratio improvement in cyclical events. Introduction Many ion beam and plasma experiments, such as afterglow studies in a pulsed plasma, involve repeated transient signals. A mass spectrometer suitable for such studies must not only include energy and mass analysis of the ion population but also allow data to be acquired during a specific time gating period synchronised with the transient. Hiden s EQP and EQS mass spectrometers have an electrostatic sector field energy analyser followed by a quadrupole mass filter and ion counting detector (Figure 1 shows the EQP analyser). The pulses from the detector can be electronically gated so that only ions detected during the gate time are counted in either the energy or mass spectrum. Figure 1 EQP Mass Spectrometer Technical Information TI505-5 1 Hiden Analytical Ltd

Time Resolved Mass and Energy Spectra (TRMES) TRMES allows data to be taken only from selected time slots in a cyclical event by controlling acquisition with a gating pulse synchronised to the event. Typical cyclical events occur in pulsed plasmas or laser ablation, which are normally controlled by a reference signal. This signal can be used to control the mass spectrometer and synchronise acquisition with the events. As shown in figure 2 the event reference signal driving the experiment is used to trigger a variable delay generator, which in turn triggers the gating pulse generator. Since the mass spectrometer can only acquire data during the gating pulse on period, increasing the delay time moves the acquisition point through the event cycle, and decreasing the gate pulse width localises the values of the parameters monitored. One of the user set control parameters in the mass spectrometer is the dwell time used to count the ions detected by the instrument at each point in the scan and derive the count rate. When time resolution gating is used, assuming the dwell time is longer than the gating pulses, the set dwell time is divided into segments by the gating pulses. Where the gate time is greater than the dwell time, acquisition of a point may complete in one or two gate pulses depending on the relative phase of the signals. If a dwell time of 1 ms has been set and each gating pulse is 10 µs wide, the dwell gate will remain open for 100 gating pulses. If the gating pulses occur at 100 µs intervals, then the total time to acquire each point will be 10 ms. (See the Timings section below.) TRMES can be used either to improve the signal to noise ratio of transient events or to monitor particular parts of the event cycle. Event reference Experiment Data Mass Spectrometer Variable Delay generator Variable Gate pulse generator External trigger Event reference T2 T1 Delay pulse Gating pulse T3 T4 T5 Figure 2 TRMES schematic Technical Information TI505-5 2 Hiden Analytical Ltd

Signal to noise improvement Time resolution sampling can improve the signal to noise ratio in experiments where the on to off time of the triggered event is small. If no gating is used, acquisition will average the count rate over the dwell period, and effectively divide the on period total counts by the dwell time to obtain the rate. If the event on period is short compared to the dwell time and only one event occurs within it, this can result in an apparently very low count rate. For example, if the event on time is 10 µs and 10 ions are counted, the actual count rate is 10 6 c/s, but if one of these events is seen during a dwell time of 10 ms, the reported count rate will be 10 3 c/s (10 ions in 10 ms). Dwell time gating is also unlikely to be synchronised with the event rate, which can result in the dwell gate opening or closing part way through an event in some cycles and not others, thus increasing the apparent noise on the signal. In extreme cases there may be no event while the dwell gate is open, resulting in an apparently zero count rate. Figure 3 gives an example of how to use TRMES to improve the signal to noise ratio in an experiment where the mass spectrometer is used to monitor the ablation plume created by a laser shot with a low repetition rate. The laser firing signal is used to trigger a delay which drives the gate generator. When the delay and gate timings are correctly adjusted the highest count rate will be seen. These timings may be set by using an oscilloscope or by using the mass spectrometer itself. To use an oscilloscope, the display must be triggered by the laser trigger and the gating pulses and the external pulse output from the mass spectrometer monitored on the screen. Delay and gate timings can then be adjusted so that the gating pulse is seen to cover the time when the greatest concentration of ion pulses occur. Using the mass spectrometer to set the timings is slightly more difficult, but does not require any other equipment. First a scan tree should be built to monitor the MID trend of the largest ion seen in the event. If this is not known, the instrument should first be used without external gating to acquire a mass scan, which can then be examined to find the largest peak. The MID scan should then be run and the monitored event cycle started. Initially the delay time should be set to zero and the gate time set to minimum or 1 µs whichever is the larger. Watching the MID trend display, increase the delay time until a signal is seen. If no signal is seen after the delay has passed through the point at which one would be expected, it may be that the actual count rate is too small to register with the minimum gate time, and the process should be repeated with a longer initial gate time. When a signal is seen, this is the delay to the start of the event reaction. The gate time should now be increased until the count rate maximises. At this point both times are optimum and should be noted for future use. Once these are set, other scan trees can be built to monitor the required parameters, and, provided the experiment does not change, the noted times can be reused. Acquisition time slot Ablation plume intensity laser trigger delay gating pulse Figure 3 Improving the signal/noise ratio of a triggered event Technical Information TI505-5 3 Hiden Analytical Ltd

Monitoring part of an event cycle. Where the condition of the monitored system changes through the event cycle, for example the plasma in a pulsed plasma system, external gating can be used to look at the ions during a small part of the cycle. This method may also be used to monitor negative ions formed in the bulk plasma which cannot normally escape the plasma due to the confining effect of the sheaths (see example figs. 5 and 6). Figure 4 shows the gating input used to monitor the afterglow in a pulsed plasma system. Here a fixed gate timing to look at the ions in a small part of the cycle. If the delay generator time is increased as data is acquired, the instrument will scan across the afterglow period. Acquisition time slot Plasma plasma power delay gating pulse Figure 4 Pulsed plasma afterglow monitoring Timings Each point that the mass spectrometer acquires is read for the set dwell period. If external gating is used, the point is not read until the sum of the gating pulses equals the dwell time. Thus the time to acquire each point is longer than that where external gating is not used. Referring also to Figure 2 above, if the set dwell time is T d and the gating pulse width is T4, then the number of gating pulses required for each point, ng is: T p T = Td 1 = T4 Td gating pulse duty cycle If T d = 100 ms, T1 = 400 µs, and T4 = 100 µs, each point requires 400 ms, and the total acquisition time for a 100 amu histogram spectrum is 40 seconds. Td ng = T 4 If the period of the gating pulses is T1 (i.e. the event reference period), then the total time to acquire each point (T p ) is: or Td Tp = ng T1= T1 T4 Technical Information TI505-5 4 Hiden Analytical Ltd

Example Figures 5 and 6 show two energy selected negative ion mass spectra from an RF Carbon Tetrachloride discharge. The spectra were taken at 25 mtorr and 70 mtorr in an inductively coupled plasma pulsed at 1kHz. Intensity / cps 9000 8000 F - 7000 6000 5000 Negative Ion Spectrum CF 4 25mT 100W 1kHz Pulse Rate 4000 3000 2000 1000 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 m/e Figure 5 Mass Spectrum at 25 mtorr Intensity / cps 2000 1800 F - 1600 1400 1200 Negative Ion Spectrum CF 4 70mT 100W 1kHz Pulse Rate 1000 800 600 400 200 F 2-0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 m/e Figure 6 Mass Spectrum at 70 mtorr Technical Information TI505-5 5 Hiden Analytical Ltd

Specifications The Mass Spectrometer Interface Unit (MSIU) external gate input should be driven by a TTL level signal with the characteristics shown below. The instrument will operate with shorter T4 and T5 times, but this is not recommended as the gate signal is retimed to an internal clock, and shorter pulse widths increase the retiming uncertainty. Refer also to Figure 2 above. Signal Minimum Maximum Event reference period (T1) > T3 + T4 - Event reference pulse width (T2) Depends on delay generator < T1 - delay generator setup time Delay period (T3) Depends on delay generator < T1 - T4 Gate on period (T4) 1 µs - Gate off period (T5) 1 µs - Gate signal rise/fall time - less than 50 ns Table 1 Timing specifications for Time Resolved Mass and Energy Spectra signals External gating signals are connected to the MSIU as follows: Description Signal Common Active high input AC-05 pin 21 AC-05 pin 9 Active low input AC-05 pin 8 AC-05 pin 9 Table 2 External gating signal connections See also the EQP/EQS Analyser Operator s Manual HA-085-003 Chapter 8 Input/Output Subsystem Manufactured in England by: HIDEN ANALYTICAL LTD 420 EUROPA BOULEVARD WARRINGTON WA5 7UN ENGLAND Tel: +44 (0) 1925 445225 Fax: +44 (0) 1925 416518 E.mail: info@hiden.co.uk Web Site: http://www.hidenanalytical.com Please note the specifications in this document may be changed and cannot form part of any contract H:\wordproc\techinfo\plasma\ti505-5.doc Technical Information TI505-5 6 Hiden Analytical Ltd