SURFACE ENGINEERING MASS SPECTROMETERS FOR THIN FILMS, PLASMA AND SURFACE ENGINEERING

Similar documents
THIN FILMS, PLASMA & SURFACE ENGINEERING. Mass Spectrometers. for Thin Films, Plasma & Surface Engineering

SNMS. SNMS Applications. Combined SIMS and SNMS

Hiden SIMS Secondary Ion Mass Spectrometers. Analysers for surface, elemental and molecular analysis

vacuum analysis plasma diagnostics surface science gas analysis

Mass Spectrometers. for Surface Analysis SURFACE ANALYSIS

Hiden HPR60 Molecular Beam Mass Spectrometer System

RESIDUAL GAS ANALYSIS MASS SPECTROMETERS FOR RESIDUAL GAS ANALYSIS - RGA

CATALYSIS & THERMAL ANALYSIS

Pressure & temperature sampling options for Hiden gas analysis systems

Hiden Analytical Ltd

Plasma Diagnostics Introduction to Langmuir Probes

Hiden EQP Systems. High Sensistivity Mass and Energy Analyzers for Monitoring, Control and Characterization of Ions, Neutrals and Radicals in Plasma.

Hiden CATLAB Systems Microreactor for Catalysis Studies & Thermal Analysis

Catalysis CAPABILITIES

FIB - SIMS. Focussed Ion Beam Secondary Ion Mass Spectrometry.

Hiden EQP Applications

Mass Spectrometer A Comparison of Positive and Negative Ion RGA Methods

Extrel is widely respected for the quality of mass spectrometer systems that are

Application of the EQP and EQS mass spectrometers to time resolved studies in ion beam and plasma processes

Defining quality standards for the analysis of solid samples

Extrel Application Note

Secondary ion mass spectrometry (SIMS)

TMT4320 Nanomaterials November 10 th, Thin films by physical/chemical methods (From chapter 24 and 25)

Secondary Ion Mass Spectroscopy (SIMS)

Thin Films, Plasma and Surface Engineering. In the Press. Plasma Diagnostics for the Researcher. Hiden Applications

Hiden Isochema. Gravimetric Gas & Vapor Sorption Analyzers. Hiden Isochema IGA Series. Advancing Sorption Analysis

Secondary Ion Mass Spectrometry (SIMS)

Quantum Technology: Supplying the Picks and Shovels

IONTOF. Latest Developments in 2D and 3D TOF-SIMS Analysis. Surface Analysis Innovations and Solutions for Industry 2017 Coventry

PHI 5000 Versaprobe-II Focus X-ray Photo-electron Spectroscopy

X-Ray Photoelectron Spectroscopy (XPS) Prof. Paul K. Chu

Thin Films, Plasma & Surface Engineering

Application of the GD-Profiler 2 to the PV domain

Wafer holders. Mo- or Ta- made holders Bonding: In (Ga), or In-free (clamped) Quick and easy transfer

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Secondary Ion Mass Spectrometry (SIMS) Thomas Sky

Modern Methods in Heterogeneous Catalysis Research: Preparation of Model Systems by Physical Methods

PHI. Scanning XPS Microprobe

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Secondary ion mass spectrometry (SIMS)

High Sensitivity Mass and Energy Analysers for Monitoring, Control and Characterisation of Ions, Neutrals and Radicals in Plasma

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

A DIVISION OF ULVAC-PHI. Time-of-Flight Secondary Ion Mass Spectrometer with Parallel Imaging MS/MS for Confident Molecular Identification

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

Quadrupole Mass Spectrometry Concepts. Mass spectrometers for residual gas analysis: Intermediate Level Users Guide

Observations Regarding Automated SEM and SIMS Analysis of Minerals. Kristofor Ingeneri. April 22, 2009

A DIVISION OF ULVAC-PHI

Jlab FEL Photoemission DC Guns

A DIVISION OF ULVAC-PHI. Quantera II. Scanning XPS Microprobe

ToF-SIMS or XPS? Xinqi Chen Keck-II

Secondaryionmassspectrometry

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

X- ray Photoelectron Spectroscopy and its application in phase- switching device study

Relative Sensitivity RS Measurements of Gases

Defining an optimal plasma processing toolkit for Indium Phosphide (InP) laser diode production

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

Chapter 7 Plasma Basic

Atomic layer deposition of titanium nitride

Lecture 22 Ion Beam Techniques

Ion Pump Applications

Repetition: Practical Aspects

Keywords. 1=magnetron sputtering, 2= rotatable cathodes, 3=substrate temperature, 4=anode. Abstract

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Technical description of photoelectron spectrometer Escalab 250Xi

Introduction to the Q Trap LC/MS/MS System

Confirmation of paper submission

Gravimetric Analysers for the Characterisation of the Sorption Properties of Materials.

Cover Page. The handle holds various files of this Leiden University dissertation.

ETCHING Chapter 10. Mask. Photoresist

INTRODUCTION TO THE HYBRID PLASMA EQUIPMENT MODEL

( 1+ A) 2 cos2 θ Incident Ion Techniques for Surface Composition Analysis Ion Scattering Spectroscopy (ISS)

Applications. Hiden. Hiden s quadrupole mass spectrometer systems address a broad application range in: Gas Analysis.

Experimental analysis of plasma conditions in an inverted cylindrical magnetron sputtering system

Surface Analysis - The Principal Techniques

Plasma Chemistry Study in an Inductively Coupled Dielectric Etcher

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Introduction to Thin Film Processing

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

Competitive Advantages of Ontos7 Atmospheric Plasma

Real-Time Chemical Sensing for Advanced Process Control in ALD

Methods of surface analysis

6.5 Optical-Coating-Deposition Technologies

In-situ Ar Plasma Cleaning of Samples Prior to Surface Analysis

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Plasma Deposition (Overview) Lecture 1

IRMS. perspective. Isotope Ratio Mass Spectrometry.

Atomic Force/Magnetic Force Microscope

THIN FILMS FOR PHOTOVOLTAICS AND OTHER APPLICATIONS. BY Dr.A.K.SAXENA PHOTONICS DIVISION INDIAN INSTITUTE OF ASTROPHYSICS

Chapter 7. Plasma Basics

The sercon group Isotope Ratio Mass

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

TECHNIC A L WORK ING GROUP ITWG GUIDELINE ON SECONDARY ION MASS SPECTROMETRY (SIMS)

PERSPECTIVE STABLE ISOTOPE RATIO MS

Plasma diagnostics of pulsed sputtering discharge

DYNAMIC VAPOR SORPTION ANALYZER FULLY AUTOMATED COMPACT BENCH-TOP DVS ANALYZER, FOR FAST AND ACCURATE SORPTION MEASUREMENTS.

Reduced preferential sputtering of TiO 2 (and Ta 2 O 5 ) thin films through argon cluster ion bombardment.

EE143 Fall 2016 Microfabrication Technologies. Lecture 6: Thin Film Deposition Reading: Jaeger Chapter 6

SCALING OF HOLLOW CATHODE MAGNETRONS FOR METAL DEPOSITION a)

Transcription:

SURFACE ENGINEERING MASS SPECTROMETERS FOR THIN FILMS, PLASMA AND SURFACE ENGINEERING

HIDEN MS MASS SPECTROMETERS for Thin Films and Surface Engineering Hiden Analytical have been designing and developing the highest quality quadrupole mass spectrometer based gas analysis systems for over 25 years. We have built a reputation for delivering instruments with superior sensitivity, accuracy and reproducibility together with a first class global service and applications support network. www.hidenanalytical.com

THIN FILM THIN FILM Thin Film Processing Thin film processing in research, development and functionalisation of surfaces has a broad application range in microelectronics, nanotechnology, solar, flat panel, mechanics, optics, photonics, textiles, coatings, chemistry, biology, and medicine. Thin film processing utilises a wide range of techniques, including: Magnetron sputtering ALD - atomic layer deposition CVD - chemical vapour deposition MOCVD - metal organic chemical vapour deposition PECVD - plasma enhanced chemical vapour deposition MBE - molecular beam epitaxial growth RIE - plasma reactive ion etch IBE/RIBE - ion beam etch and reactive ion beam etch Each technique is often tailored for a specific application, requiring special process parameters to produce the surface/film properties required. CONTENTS: Hiden mass spectrometers provide critical insight into thin film processing and characterisation enabling optimisation of thin film production and surface quality. Hiden systems are individually configured to ensure optimum analyser response for sensitivity and speed. HPR-30 and RGA residual gas analysers PSM and EQP plasma ion analysers ESPion Langmuir probe IMP-EPD end point detector for IBE/RIBE XBS - MBE deposition flux rate monitor SIMS systems & components UHV TPD workstation

HPR-30 The HPR-30 is a residual gas analyser configured for analysis of gases and vapours in vacuum processes and for vacuum diagnostics. The system is fully configurable for individual process applications such as CVD, plasma etching, MOCVD, process gas purity and in-process contaminant monitoring. HPR-30 & RGA Process and Residual Gas Analysis The HPR-30 system features a close-coupled re-entrant aperture for sampling directly within the process region, providing maximum data integrity and fast confirmation of process status. Options include the innovative Hiden 3F series triple filter quadrupole system providing enhanced abundance sensitivity, part-per-billion (ppb) detection levels and high contamination resistance, particularly suited to the analysis of aggressive gases in CVD and RIE applications. HPR-30 The HPR-30 sampling system configuration is directly suited to analysis of high mass species and precursors used in ALD and MOCVD applications. HPR-30 data on TiN deposition Products RGA Series - residual gas analysers for vacuum measurement through to fundamental scientific research. qrga with separation of He/D 2, 3 He/HD/T and deuterated hydrocarbons (e.g. C x H y and C x D y ) with mass range to 200 amu. HPR-30 Series - vacuum process analysers configured for high sensitivity, fast response gas and vapour analysis of thin film deposition and etching processes: CVD, ALD, MOCVD and RIE for example. RGA FEATURES/OPTIONS: custom inlet systems with optimised sampling for metals and metal organic vapours high mass range options available - 500 and 1000 amu high sensitivity RGA for UHV quality chamber base pressure measurements and leak detection re-entrant sampling orifice for fast response to process gas/vapour composition changes gas/vapour sampling systems optimised for response and sensitivity over a wide pressure range www.hidenanalytical.com RGA series

EQP & PSM EQP & PSM Plasma Sampling Mass Spectrometers A wide range of industrial processes use electrical plasmas, and new applications are developing rapidly. In the microelectronics industry the demands of higher yields and shrinking device geometries mean that process reproducibility and understanding is vital. Hiden plasma probes measure some of the key plasma parameters and provide detailed information relating to plasma reaction chemistry. EQP Detailed understanding of the reaction kinetics of plasma ions and neutral species plays a key role in the development of advanced surface engineering processes such as HIPIMS. EQP system - in plasma The EQP system directly measures mass and energy of both positive and negative process ions, measuring masses up to 2500 amu and ion energies up to 1000 ev. The integral electron bombardment ion source provides for analysis of neutrals and, with the addition of the EAMS (electron attachment mass spectrometry) electron attachment mode, for separation and identification of electronegative radical species. 2 10M E = 0.5 ev FEATURES/OPTIONS: mass and energy analysis of positive and negative ions neutrals and neutral radical analysis magnetic shielding options for magnetically confined plasmas integral signal gating with automatic timing control for detailed pulsed plasma analysis PSM analyser includes an in-line energy analyser for positive ion analysis EQP analyser includes a 45 degree sector field energy analyser for positive and negative ion analysis Flux, (x10 6 counts -1 ) 1 0 Countrate, cs -1 1M 100k 10k 1k 100 Cr(1+) Ar(1+) 10 0 5 10 Energy, (ev) N 2(1+) N 2 + 0 10 20 30 40 50 60 mass: amu Example EQP data N + Cr 2+ Ar + Cr+

ESPion PROBE ESPion LANGMUIR PROBE for Measurement of Plasma Properties The ESPion Langmuir probe provides for measurement of the electrical properties of plasmas including: Plasma Potential Floating Potential Electron Temperature Electron Density Ion Density Electron Energy Distribution Ion Flux ESPion with 300 mm automatic Z-drive ESPion data Routine monitoring of the I-V plasma characteristic by the Hiden ESPion probe gives direct information relating to plasma stability and reproducibility. Automatic real-time extrapolation of plasma parameters gives detailed information on plasma properties for use in characterisation and uniformity monitoring. The ESPion system employs Orbital Motion Limited (OML) and Allen Boyd Reynolds (ABR) as standard plasma analysis models. The Hiden automatic Z-drive provides for spatially resolved measurements across the plasma volume. The standard Z-drive translation options are: 300, 600 and 900 mm. ESPION PROBES MEASURE: ion and electron density over the range 10 14-10 19 m -3 electron temperature up to 10 ev Electron Energy Distribution Function (EEDF) plasma potential floating potential Debye length developed for pulsed, DC, RF and ECR plasma integrated signal gating for pulsed plasma analysis www.hidenanalytical.com

IMP-EPD IMP-EPD End Point Detector for Ion Beam Etch The IMP-EPD is a differentially pumped, ruggedised secondary ion mass spectrometer for the analysis of secondary ions and neutrals from the ion beam etch process. The system includes integrated software with process specific algorithms developed for optimum process control. The IMP-EPD system is process proven for the production of high specification thin film devices for applications IMP-EPD with Z-drive including magnetic thin films, high temperature superconductors and III-V semiconductors. End point controls: Ta / NiFe /Ta SEM c/s 14000 13000 12000 11000 10000 9000 8000 7000 6000 5000 4000 Tantalum Nickel Rising and falling edge algorithms Layer counting for end point on a selected interface in a multilayered stack Endpoint relative to a reference peak 3000 2000 1000 0 00:00 03:20 06:40 10:00 13:20 16:40 20:00 Time MM:SS Automatic signal correction due to wafer rotation IMP data 100000 Multilayered Sample: FeMn/NiFe/Co/Cu/Co/NiFe/Ta Iron 10000 Copper APPLICATIONS: end point analysis SEM c/s 1000 100 Manganese Cobalt Nickel target impurity determination quality control/spc 10 00:00 01:40 03:20 05:00 06:40 08:20 10:00 11:40 13:20 15:00 Time MM:SS Tantalum residual gas analysis leak detection SEM c/s Multilayered Sample: FeMn/NiFe/Co/Cu/Co/NiFe/Ta 160000 15000 14000 13000 12000 11000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 04:50 05:10 05:30 05:50 06:10 06:30 06:50 07:10 07:30 07:50 08:10 Time MM:SS Iron Copper Manganese Cobalt Nickel Tantalum

XBS XBS TRIPLE FILTER MS MBE Deposition Flux Rate Monitor Electron beam (e-beam) sources require accurate control for reproducible production quality thin film growth. Hiden s XBS system provides in-situ monitoring of multiple sources with real-time signal output for precise control of the deposition. The high sensitivity and fast data acquisition of the XBS system provide signals for control of growth rates from 0.01 Angstrom per second. MBE monitoring and control Molecular beam studies XBS probe Multiple beam source analysis High performance RGA Desorption / outgassing studies / bakeout cycles Chamber / process gas contaminants XBS probe with water-cooled shroud and z-drive www.hidenanalytical.com Integral water-cooled shroud FEATURES: high sensitivity, enhanced detection from 100% to 5 ppb, mass range to 510 amu enhanced long-term stability (less than ±0.5% height variation over 24 h) crossbeam ion source, beam acceptance through +/- 35 to transverse axis ion source control for soft ionisation and appearance potential mass spectrometry enhanced sensitivity for high mass transmission 2 mm beam acceptance aperture configured to specific user application

TPD WORKSTATION TPD WORKSTATION for UHV Thermal Desorption Studies The Hiden TPD Workstation is a complete experimental system for UHV temperature programmed desorption (TPD) studies. The TPD Workstation features a multiport UHV chamber with heated sample stage coupled to a high precision triple filter analyser with digital pulse ion counting detector for ultimate sensitivity and time resolution. The triple filter mass analyser is configured TPD Workstation viewport with a liquid N 2 cooled shroud giving the analyser optimum sensitivity to desorption products from the sample. A fast sample load lock with sample transfer mechanism is included to provide for rapid sample change. Hiden s TPDsoft thermal analysis PC software included with the Workstation provides automatic control of sample temperature integrated with analyser control. TPD analysis routines (e.g. peak integration/deconvolution etc) are also included in this package. Software provides control and TPD analysis routines FEATURES: Hiden 3F PIC mass spectrometer for fast data acquisition (>500 data points per sec) multiport UHV chamber for attachment of additional instrumentation (e.g. ellipsometry) linear sample transfer mechanism and loadlock, including gate valve and viewport heated sample stage to 1000 C Z-drive for optimum sample/detector positioning TPD Workstation bakeout jacket (200 C max) integrated software control of experimental protocols

SIMS/SNMS SIMS/SNMS SYSTEMS for Thin Film Surface Analysis SIMS is a high sensitivity surface analysis technique for the determination of surface composition, contaminant analysis and for depth profiling in the uppermost surface layers of a sample. Applied to analysis within the first few microns of a surface, Hiden's SIMS systems provide depth profiles with depth resolution to 5 nanometres. The Hiden SIMS Workstation provides for high performance static and dynamic SIMS applications for detailed surface composition analysis and depth profiling. Hiden's elemental SIMS imaging facility provides for high resolution surface chemical mapping. SIMS Workstation The SNMS facility complements the SIMS technique, providing quantification for thin film composition measurements. Hiden s new SIMS-on-a-Flange provides a complete SIMS facility on a single UHV conflat type flange. SIMS-on-a-Flange SURFACE ANALYSIS COMPONENTS: EQS spectrometer SIMS Workstation - full SIMS/SNMS facility SIMS-on-a-Flange - a complete SIMS analysis system on a single conflat flange MAXIM - SIMS/SNMS analyser EQS - surface science analyser SIM - low cost SIMS/surface science analyser www.hidenanalytical.com

SIMS/SNMS SIMS/SNMS SYSTEMS for Thin Film Surface Analysis SIMS offers very high sensitivity, PPM/PPB level contamination analysis; significantly higher in sensitivity than routine XPS analysis (for example), by several orders of magnitude SIMS provides unrivalled performance for depth profile and interface analysis, vital in the development of coatings SNMS uniquely offers quantitative surface analysis (for example, dopant levels) IG20 gas ion gun Intensity / s -1 2x10 6 1x10 6 Positive SIMS mass spectrum of contamination 0 0 10 20 30 40 50 60 70 m/z IG5C-caesium ion gun for high sensitivity negative ion SIMS analysis of electro-negative species. The 56 Fe image of a hard steel engine component shows Fe, Cr (and Na and K) on the clean surface. A mass spectrum in the region of a stain, which masks the iron signal, shows surface contamination by calcium - a bio-diesel contaminant Intensity / s -1 2x10 5 1x10 5 0 0 10 20 30 40 50 60 70 m/z Positive SIMS mass spectrum of cleaned surface IG20 - general purpose argon/oxygen ion gun for depth profiling IG5C - caesium ion gun for electro-negative species for thin film depth profile and surface imaging analysis Surface Analysis Systems - modular UHV grade surface analysis platforms Signal intensity (s -1 ) 10 6 10 5 10 4 10 3 10 2 10 1 10 0 22 23 24 25 26 27 28 29 30 31 32 m/z Dopant depth profiling - SIMS detects and quantifies semiconductor dopants and impurities with high sensitivity and accuracy making it suitable for the study of redistribution and diffusion phenomena as well as production monitoring. The analysis shown was made using 5 kev Cs + primary ions from the IG5C whilst collecting AsSi - secondary ions Concentration / atoms cm -3 5E15 As implant into Si 1.E+21 As 1.E+20 1.E+19 1.E+18 1.E+17 1.E+16 0 50 100 150 200 250 Depth / nm Positive SIMS mass spectrum from Si target, 5 kev Ar + primary ions

HIDEN APPLICATIONS Hiden s quadrupole mass spectrometer systems address a broad application range in: Gas Analysis Surface Science Plasma Diagnostics Vacuum Analysis dynamic measurement of reaction gas streams catalysis and thermal analysis molecular beam studies dissolved species probes fermentation, environmental and ecological studies UHV TPD SIMS end point detection in ion beam etch elemental imaging - surface mapping plasma source characterisation etch and deposition process reaction kinetic studies analysis of neutral and radical species partial pressure measurement and control of process gases reactive sputter process control vacuum diagnostics vacuum coating process monitoring quadrup oles for advanced science Hiden Analytical Ltd. 420 Europa Boulevard Warrington WA5 7UN England Tel: +44(0)1925 445225 Fax: +44(0)1925 416518 Email: info@hiden.co.uk Web: www.hidenanalytical.com TECHNICAL DATA SHEET 184 Hiden Analytical E & O E