Effect of AFM Cantilever Geometry on the DPL Nanomachining process

Similar documents
Vibration Studying of AFM Piezoelectric Microcantilever Subjected to Tip-Nanoparticle Interaction

Atomic Force Microscopy imaging and beyond

Measuring the spring constant of atomic force microscope cantilevers: thermal fluctuations and other methods

Characterization of MEMS Devices

NIS: what can it be used for?

DETERMINATION OF THE ADHESION PROPERTIES OF MICA VIA ATOMIC FORCE SPECTROSCOPY

Basic Laboratory. Materials Science and Engineering. Atomic Force Microscopy (AFM)

3.052 Nanomechanics of Materials and Biomaterials Thursday 02/08/06 Prof. C. Ortiz, MIT-DMSE I LECTURE 2 : THE FORCE TRANSDUCER

Dynamic Analysis of AFM in Air and Liquid Environments Considering Linear and Nonlinear Interaction Forces by Timoshenko Beam Model

Noninvasive determination of optical lever sensitivity in atomic force microscopy

Title Single Row Nano-Tribological Printing: A novel additive manufacturing method for nanostructures

Point mass approximation. Rigid beam mechanics. spring constant k N effective mass m e. Simple Harmonic Motion.. m e z = - k N z

FEM-SIMULATIONS OF VIBRATIONS AND RESONANCES OF STIFF AFM CANTILEVERS

Optimal Design and Evaluation of Cantilever Probe for Multifrequency Atomic Force Microscopy

SCANNING-PROBE TECHNIQUES OR APPARATUS; APPLICATIONS OF SCANNING-PROBE TECHNIQUES, e.g. SCANNING PROBE MICROSCOPY [SPM]

Outline Scanning Probe Microscope (SPM)

Scanning Probe Microscopy. Amanda MacMillan, Emmy Gebremichael, & John Shamblin Chem 243: Instrumental Analysis Dr. Robert Corn March 10, 2010

Lecture 4 Scanning Probe Microscopy (SPM)

Introduction to Scanning Probe Microscopy

1859. Forced transverse vibration analysis of a Rayleigh double-beam system with a Pasternak middle layer subjected to compressive axial load

AFM for Measuring Surface Topography and Forces

State Feedback Control for Adjusting the Dynamic Behavior of a

Scanning Force Microscopy

Improving the accuracy of Atomic Force Microscope based nanomechanical measurements. Bede Pittenger Bruker Nano Surfaces, Santa Barbara, CA, USA

Simulation of atomic force microscopy operation via three-dimensional finite element modelling

General concept and defining characteristics of AFM. Dina Kudasheva Advisor: Prof. Mary K. Cowman

Introductory guide to measuring the mechanical properties of nanoobjects/particles

Module 26: Atomic Force Microscopy. Lecture 40: Atomic Force Microscopy 3: Additional Modes of AFM

Lecture 12: Biomaterials Characterization in Aqueous Environments

Features of static and dynamic friction profiles in one and two dimensions on polymer and atomically flat surfaces using atomic force microscopy

Sliding Mode Control of AFM in Contact Mode during Manipulation of Nano-Particle

Contents. What is AFM? History Basic principles and devices Operating modes Application areas Advantages and disadvantages

CHAPTER 4 DESIGN AND ANALYSIS OF CANTILEVER BEAM ELECTROSTATIC ACTUATORS

Lorentz Contact Resonance for viscoelastic measurements of polymer blends

Title Single Row Nano-Tribological Printing: A novel additive manufacturing method for nanostructures

Design and Analysis of Various Microcantilever Shapes for MEMS Based Sensing

2018. Nonlinear free vibration analysis of nanobeams under magnetic field based on nonlocal elasticity theory

Lecture Note October 1, 2009 Nanostructure characterization techniques

Size dependence of the mechanical properties of ZnO nanobelts

ELASTIC MODULUS MEASUREMENT OF NANOCOMPOSITE MATERIALS BY ATOMIC FORCE MICROSCOPY

Lorentz Contact Resonance for viscoelastic measurements of polymer blends

AFM Imaging In Liquids. W. Travis Johnson PhD Agilent Technologies Nanomeasurements Division

Dynamic Mechanical Analysis (DMA) of Polymers by Oscillatory Indentation

Investigation of Dynamical and Static Operation Modes of Atomic Force Microscope

Rheological measurements using microcantilevers

Characterisation Programme Polymer Multi-scale Properties Industrial Advisory Group 22 nd April 2008

Micro-rheology of cells and soft matter with the NanoTracker

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

Supporting Information. for. Angew. Chem. Int. Ed. Z WILEY-VCH Verlag GmbH & Co. KGaA

Modeling, Simulation and Optimization of the Mechanical Response of Micromechanical Silicon Cantilever: Application to Piezoresistive Force Sensor

TECHNIQUE TO EVALUATE NANOMECHANICS OF CANTILEVER AT NANOSCALE BY USING AFM

Finite Element Analysis of Piezoelectric Cantilever

The New Boundary Condition Effect on The Free Vibration Analysis of Micro-beams Based on The Modified Couple Stress Theory

Measurement of hardness, surface potential, and charge distribution with dynamic contact mode electrostatic force microscope

Foundations of Ultraprecision Mechanism Design

NONLINEAR ANALYSIS OF PULL IN VOLTAGE IN MICRO- CANTILEVER BEAM

Probing the Hydrophobic Interaction between Air Bubbles and Partially. Hydrophobic Surfaces Using Atomic Force Microscopy

INTRODUCTION TO SCA\ \I\G TUNNELING MICROSCOPY

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Microstructure cantilever beam for current measurement

MSN551 LITHOGRAPHY II

Atomic Force Microscopy (AFM) Part I

The Fluid-Coupled Motion of Micro and Nanoscale Cantilevers

RP 2.7. SEG/Houston 2005 Annual Meeting 1525

Characterization of MEMS Devices

AFM-Based Manufacturing for Nano-fabrication Processes: Molecular Dynamics Simulation and AFM Experimental Verification

Institute for Electron Microscopy and Nanoanalysis Graz Centre for Electron Microscopy

MODELING OF T-SHAPED MICROCANTILEVER RESONATORS. Margarita Narducci, Eduard Figueras, Isabel Gràcia, Luis Fonseca, Joaquin Santander, Carles Cané

Investigation of the Local Mechanical Properties of the SAC Solder Joint with AFM Judit Kámán a *, Attila Bonyár b

High-resolution imaging of elastic properties using harmonic cantilevers

Atomic and molecular interactions. Scanning probe microscopy.

And Manipulation by Scanning Probe Microscope

Scanning Probe Microscopy (SPM)

Outline. 4 Mechanical Sensors Introduction General Mechanical properties Piezoresistivity Piezoresistive Sensors Capacitive sensors Applications

ADVANCED DYNAMIC MECHANICAL ANALYSIS OF A TIRE SAMPLE BY NANOINDENTATION

Integrating MEMS Electro-Static Driven Micro-Probe and Laser Doppler Vibrometer for Non-Contact Vibration Mode SPM System Design

Nanomechanics Measurements and Standards at NIST

Please allow us to demonstrate our capabilities and test us testing your samples!

SUPPLEMENTARY INFORMATION

MS482 Materials Characterization ( 재료분석 ) Lecture Note 11: Scanning Probe Microscopy. Byungha Shin Dept. of MSE, KAIST

Intermittent-Contact Mode Force Microscopy & Electrostatic Force Microscopy (EFM)

DESIGN AND APPLICATION

Design and Control of Phase-Detection Mode Atomic Force Microscopy for Cells Precision Contour Reconstruction under Different Environments

2d-Laser Cantilever Anemometer

Mapping the mechanical stiffness of live cells with the scanning ion conductance microscope

Supporting Information. for. A robust AFM-based method for locally measuring the elasticity of. samples

nano-ta: Nano Thermal Analysis

GDQEM Analysis for Free Vibration of V-shaped Atomic Force Microscope Cantilevers

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

Finite Element Analysis Lecture 1. Dr./ Ahmed Nagib

142. Determination of reduced mass and stiffness of flexural vibrating cantilever beam

Noise, AFMs, and Nanomechanical Biosensors

Scanning Tunneling Microscopy

RHK Technology Brief

VEDA - Virtual Environment for Dynamic Atomic Force Microscopy

Positioning, Structuring and Controlling with Nanoprecision

Nanoindentation shape effect: experiments, simulations and modelling

Parametric Investigation of the Common Geometry Shapes for Added Mass Calculation

Instrumentation and Operation

Measurements of interaction forces in (biological) model systems

Transcription:

Int J Advanced Design and Manufacturing Technology, Vol. 9/ No. 4/ December 2016 75 Effect of AFM Cantilever Geometry on the DPL Nanomachining process A. R. Norouzi Department of New Sciences and Technologies, University of Tehran, Tehran, Iran E-mail: ahmad.r.norouzi@ut.ac.ir M. Tahmasebipour * Department of New Sciences and Technologies, University of Tehran, Tehran, Iran Email: tahmasebipour@ut.ac.ir *Corresponding author Received: 18 August 2016, Revised: 15 October 2016, Accepted: 3 November 2016 Abstract: With the development of micro and nanotechnology, machining methods at micro and nanoscale have now become interesting research topics. One of the recently-proposed methods for sub-micron machining, especially nanomachining, is dynamic plowing lithography (DPL) method. In this method an oscillating tip is used for machining soft materials such as polymers. The geometry of the oscillating beam and its vibrational properties are the most important parameters in this nanomachining process. In this study, effects of the AFM beam geometry on its stiffness coefficient, resonant frequency, beam stability, and the maximum stress created in the beam structure were investigated for 12 different general shapes using the finite element method. The obtained results indicate that circular and square membranes are the most favourable AFM cantilever geometries because these structures provide higher machining force and speed; while for noisy conditions and environments, straight and V-shaped beams are recommended (because of their higher stability factor) for the DPL nanomachining process. Keywords: AFM Beam, AFM nanomachining, DPL nanomachining, Dynamic plowing lithography, Nano lithography, Oscillating tip Reference: Norouzi, A. R., and Tahmasebipour, M., Effect of AFM Cantilever Geometry on the DPL Nanomachining Process, Int J of Advanced Design and Manufacturing Technology, Vol. 9/ No. 4, 2016, pp. 75-80. Biographical notes: M. Tahmasebipour is an assistant professor in the Faculty of New Sciences and Technologies at the University of Tehran (Iran). His research interests include Micro/Nanotechnology, MEMS/NEMS, Micro/Nanofluidics systems, Micro/Nanomanufacturing, Micro/Nano sensors & actuators, Nanomechanics, Nanostructures, and Nanocomposites. Dr. Tahmasebipour is a recipient of the TWAS prize (2011) to young scientists and 24th Khwarizmi International Award from Iranian Research Organization for Science and Technology (IROST, 2011). A. R. Norouzi received his MSc degree in Micro- Nanoelectromechanical Systems from University of Tehran, Iran (2016).

76 Int J Advanced Design and Manufacturing Technology, Vol. 9/ No. 4/ December 2016 1 INTRODUCTION Atomic force microscopy (AFM) machining is one of the few methods that can create small nanoscale features. This method has been widely studied in recent years. Intensive efforts have been made for AFM nanomachining like different techniques such as Dip- Pen Nanolithography (DPNL) [1], thermal affecting [2], mechanical nanomachining [3], and the field emission. Due to their widespread use in macroscale, mechanical machining methods have attracted particular attention. The implementation of computer numerical control (CNC) techniques using SPM at the nanoscale has been investigated in a number of studies [4], [5]. Two methods that are used in mechanical AFM nanomachining are as follows: plowing the sample surface using the static force-displacement indentation (FDI) method and using the dynamic plowing lithography (DPL) method. The later method is used for creating groove on the surface of soft and polymer samples [6]. The advantage of the static method lies in its capability in machining a variety of materials, whereas its disadvantage is low tool life and low machining speed compared to the dynamic method (DPL). The dynamic method can only be used for machining polymers and other soft materials. The ridges formed along the grooves are much larger in the dynamic method compared to the static method, and the ridge density in the DPL method is much lower than that in the FDI method. A number of techniques have been proposed to eliminate them or reduce their size, which are not applicable in the FDI method [6], [7]. Thus, higher speeds and longer tool life have made the dynamic method a better choice in the nanomachining of polymers compared to the static method. Accordingly, several researches have been conducted to optimize this method, through studying damping, force, and beam stiffness coefficient, duration of the contact between the tip and the sample surface, as well as the beam deformation [8-20]. One of the main components of this nanomachining process that directly affects the machining results is the cantilever that acts as a spring to which the tip is attached. The most important parameter in a beam is its stiffness. The higher the stiffness, the greater force exerted by the tip to the surface (considering a constant displacement) and, consequently, the greater the plastic deformation (the amount of material removed from the sample surface) [21]. The beam stiffness is also directly related to its natural frequency (which is the beam working frequency). Increased beam stiffness increases the machining speed. Increasing the machining speed is very important especially in top-down manufacturing, which is generally slow, and can further expand its applications. Beam stability is another important parameter in the DPL process. Beam stability can be evaluated through calculating the ratio of the second mode frequency to that of the first mode. Higher frequency of the second mode compared to the first mode means that second vibrational mode is distant from the first mode which causes the beam to remain in the first vibrational mode. The final parameter is the maximum stress induced in the beam. The nanomachining depth (groove depth) is determined by the vibration amplitude of the beam, which is known and constant. It is desired to have less stress in the beam structure for a constant deflection (vibration amplitude) because lower stress causes increase in the beam s life or allows the nanomachining depth to be increased. In this research, effect of the AFM beam geometrical shape on its stiffness coefficient, resonant frequency, stability and maximum stress was studied using the finite element method. 2 MODELING OF THE AFM CANTILEVER In this research, finite element analysis method was used to evaluate effect of the AFM beam geometry on the DPL nanomachining process through the following parameters: 1. Stiffness coefficient of the beam: An increased stiffness coefficient increases the beam stiffness and the force is exerted on the sample surface and consequently allows machining of the harder materials. 2. The natural or resonance frequency: the greater the resonance frequency, the higher the machining speed. 3. Beam stability: Increase in the beam stability raises accuracy and repeatability of the machining process and the tool life. 4. The stress induced in the beam: a low stress value ensures longer beam life and allows for increasing the depth of nanomachining. A 225 35 7 commercial cantilever (Pointprobe NCL, Nanosensors, Wetzlar-Blankenfeld, Germany) with a natural frequency of 156 KHz and spring constant of 30 N/m [7] was used for modelling as the base dimensions. As it is shown in the Fig. 1, Effect of the different beam geometries including base cantilever, cantilevers with half and twice the width of the base cantilever, V-shaped beam with angles of 30, 60, 90 and 120, X-shaped beam, square beam (membrane) with four constrained sides, and circular beam (membrane) with constrained circumference was studied. 3 RESULTS AND DISCUSSION 3.1. Stiffness Coefficient Stiffness coefficient or spring constant of the AFM beam is an important parameter in DPL nanomachining

Int J Advanced Design and Manufacturing Technology, Vol. 9/ No. 4/ December 2016 77 process. Several studies have measured the spring constant and evaluated its impact on machining [9], [19], [22]. According to Eq. (1), stiffness coefficient (K) is directly related to the force applied by the beam on the sample surface. An increased stiffness increases the applied force (F) and the deformation generated in the sample, as well as machinability of the process, and allows for machining of the harder materials [9]. F Kx (1) Where, x is deflection of the beam. According to Eq. (2), an increased stiffness coefficient increases the natural frequency of the beam which, in turn, increases the nanomachining speed. K (2) m In order to calculate the stiffness coefficient of different beam geometries, a known 10-4 N force was applied to the free end of the beam, and the displacement was determined through the finite element method. The spring constant was then calculated using Eq. (1). The results are presented in Fig. 2. The stiffness coefficient calculated for the straight beam with dimensions similar to the base dimensions was 36.11 N/m which is very close to the value reported by [7]. This validates the presented model in this research. A comparison between the stiffness coefficients calculated for different beam geometries showed that the circular membrane has the highest stiffness coefficient. Further investigations showed that the beams that were constrained in more than one side have higher stiffness coefficients compared to those that were constrained in only one side. Therefore, they can be used to increase the stiffness coefficient of the vibrating beam and improve the machining efficiency. Among the beams constrained at one side, the 90 V- shaped beam geometry is the best geometry that has the highest stiffness coefficient. Another point observed in this study was that in straight beams, an increased beam width increases the stiffness coefficient and, consequently, the machining force. However, it should be noted that increase in the stiffness coefficient reduces the sensitivity in sensing applications of the AFM cantilever because this would require higher interatomic forces to overcome the spring constant for maintaining optimal performance of the AFM in topography applications. Therefore, this issue should be noted in applications other than nanomachining. As it can be seen in Fig. 2, the stiffness coefficient increases in the following order with beam shape: the straight beam with half-width of the base cantilever (b), straight cantilever (a), 30 V-shaped beam (e), straight beam with twice-width of the base cantilever (c), U- shape cantilever (d), 60 V-shaped beam (f), triangular beam (i), 120 V-shaped beam (h), 90 V-shaped beam (g), X-shaped beam (j), square membrane (k), and the circular membrane (l). Fig. 1 The studied AFM cantilevers; straight cantilever (as base dimension): a, cantilever with half of the width of base cantilever: b, and twice the width of base cantilever: c, U-Shape cantilever: d, 30, 60, 90, and 120 degree V-Shape beams: e, f, g, and h, respectively, triangular beam: i, X-Shape beam: j, square membrane: k, and circular membrane: l Fig. 2 The Stiffness coefficients calculated for different beam geometries 3.2. Resonant frequency In order to improve efficiency in both machining and surface evaluation modes, the AFM beam must vibrate

78 Int J Advanced Design and Manufacturing Technology, Vol. 9/ No. 4/ December 2016 at its natural frequency. Considering the importance of this issue, several studies have been conducted on AFM beam vibration [11], [12], [18], [20]. In the present study, vibrational analysis of the AFM beam with various geometric shapes was performed using the finite element method and the natural frequency of the beams was determined. Results of this simulation including the first mode shape of the studied AFM beams are shown in Fig. 3. As previously mentioned, an increase in the natural frequency is desirable since it can increase the nanomachining speed. Figure 4 represents the natural frequency of the beams calculated for different geometric shapes. In straight beams, increasing width enhances the stiffness; however, it does not considerably affect the natural frequency. Unexpectedly, using two straight beams connected via a joint to form a U-shaped beam significantly reduces the natural frequency of the beam as a whole. It was observed that the circular membrane has the highest natural frequency. Among the beams constrained on one end (side), the 120 V-shaped beam has the highest frequency. It was observed that the natural frequency calculated for the base cantilever (base dimensions) is in a good agreement with the natural frequency computed by reference 7. This also shows the validity of the modeling performed in this research. According to the Fig. 4, among the AFM beams, the circular membrane (l) has the highest natural frequency, followed by 120 V-shaped beam (h), square membrane (k), 90 V-shaped beam (g), 30 V- shaped beam (e), triangular beam (i), X-shaped beam (j), 60 V-shaped beam (f), straight beam with twicewidth of the base cantilever (c), base cantilever (a), straight cantilever with half-width of the base cantilever (b), and U-shaped beam (d). Fig. 4 The Natural frequency for different beam geometries. Fig. 3 First mode shape of the studied AFM beams 3.3. Stability Oscillators generally tend to vibrate around their natural frequency. However, in some cases, they may exit from their initial frequency mode and vibrate under undesirable conditions in other frequency modes. When beams vibrate at higher frequencies, the mode shape also changes, and the tip and the sample can be damaged. Therefore, in designing AFM beams, the second natural frequency is better than the first natural frequency. To address this problem, the frequencies of the first and second resonance frequency modes were calculated using the finite element method. Then, ratio of natural frequency of the second mode to that of the first mode was obtained. As this ratio increased, stability of the AFM beam enhances. Fig. 5 Ratio of the second to first mode of the natural frequency for different beams. Fig. 5 indicates ratio of the second to first mode of the natural frequency for different beams. It is observed that, in terms of stability, V-shaped beams are the best selection after the straight beams. Although square and circular membranes are better options considering

Int J Advanced Design and Manufacturing Technology, Vol. 9/ No. 4/ December 2016 79 stiffness coefficient and natural frequency, they have low stability. Therefore, they are not recommended for noisy environments. It was also observed that in straight beams, an increased width increases stability. As can be seen in Fig. 5, the straight beam with twicewidth of the base cantilever (c) has the highest stability among the AFM beams, followed by the base cantilever (a), 60 V-shaped beam (f), 30 V-shaped beam (e), triangular beam(i), 90 V-shaped beam (g), 120 V-shaped beam (h), straight cantilever with halfwidth of the base cantilever (b), X-shaped beam (j), U- shaped beam (d), circular membrane (l) and square membrane (k). finite element method. Results of this simulation are shown in Fig. 6. As it can be seen in Fig. 7, the circular membrane (l) has the highest maximum stress among the AFM beams, followed by the square membrane (k), 120 V- shaped beam (h), X-shaped beam (j), 90 V-shaped beam (g), 60 V-shaped beam (f), triangular beam (i), 30 V-shaped beam (e), U-shaped beam (d), straight beam with twice-width of the base cantilever (c), base cantilever (a), straight cantilever with half-width of the base cantilever (b). Therefore, the maximum and minimum stresses occurred in the circular membrane and straight cantilever with half-width of the base cantilever, respectively. As a result, the straight cantilever with half-width of the base cantilever is the best choice with regards to the beam life and the potential to be used in larger displacements. Fig. 7 Maximum von Mises stress induced in the studied beams for a constant displacement 7 CONCLUSION Fig. 6 The Von Mises stress induced in the studied AFM beams with different shapes 3.4. Von Mises Stress analysis Oscillators in the atomic force microscope are set to a certain displacement amplitude. The displacement is in a way that it does not damage the beam; however, reducing the displacement excessively decreases the efficiency of AFM. At a certain tip displacement, lower maximum stress values are more desirable, because it increases the beam life, and the beam can be used in larger displacements. To measure this parameter, a fixed 5 µm displacement was applied to the free end of the beam (to the center of the X-shaped beam, square and circular membranes) and the maximum von Mises stress induced in the beam was calculated using the In this paper, effect of the AFM beam geometry on the DPL nanomachining capabilities was analysed using the finite element method. The characteristics of stiffness coefficient, resonance frequency, stability, and maximum stress were investigated for 12 AFM cantilevers with different geometry shapes. This Analysis showed that the square and circular vibrating membranes are more suitable among the geometries constrained in the circumference, and 120 and 90 V- shaped beams among the beams fixed at one end with regards to stiffness and oscillation frequency. Using such geometries increases speed and efficiency of the DPL nanomachining. However, these oscillators are not desirable in terms of stability and maximum stress. Therefore, straight and V-shaped beams (rather than 120 and 90 degree) are recommended for the DPL nanomachining where unfavourable oscillations and noises exist. In straight beams, increasing the beam width improves nanomachining characteristics but

80 Int J Advanced Design and Manufacturing Technology, Vol. 9/ No. 4/ December 2016 decreases the beam life. In general, triangular beam is found to be more suitable for the DPL nanomachining applications considering the four parameters of stiffness coefficient, resonant frequency, stability, and maximum stress. REFERENCES [1] Huang, L., Braunschweig, A. B., Shim, W., Qin, L., and Lim, J. K., et al., Matrix Assisted Dip Pen Nanolithography and Polymer Pen Lithography, Small, Vol. 6, No. 10, 2010, pp. 1077 1081. [2] Gnecco, E., Riedo, E., King, W. P., Marder, S. R., and Szoszkiewicz, R.,. Linear ripples and traveling circular ripples produced on polymers by thermal AFM probes, Physical Review B, Vol. 79, No. 23, 2009, pp. 235421. [3] Sumomogi, T., Endo, T., Kuwahara, K., Kaneko, R., and Miyamoto, T., Micromachining of metal surfaces by scanning probe microscope, Journal of Vacuum Science & Technology B, Vol. 12, No. 3, 1994, pp. 1876 1880. [4] Yan, Y., Hu, Z., Zhao, X., Sun, T., Dong, S., and Li, X., Top Down Nanomechanical Machining of Three Dimensional Nanostructures by Atomic Force Microscopy, Small, Vol. 6, No. 6, 2010, pp. 724-728. [5] Yan, Y., Sun, T., Liang, Y., and Dong, S., Investigation on AFM-based micro/nano-cnc machining system, International Journal of Machine Tools and Manufacture, Vol. 47, No. 11, 2007, pp. 1651-1659. [6] Cappella, B., Sturm, H., Comparison between dynamic plowing lithography and nanoindentation methods, Journal of applied physics, Vol. 91, No. 1, 2002, pp. 506 512. [7] Cappella, B., Sturm, H., Weidner, S. M., Breaking polymer chains by dynamic plowing lithography, Polymer, Vol. 43, No. 16, 2002, pp. 4461-4466. [8] Su, C., Huang, L., and Kjoller, K., Direct measurement of tapping force with a cantilever deflection force sensor, Ultramicroscopy, Vol. 100, No. 3, 2004, pp. 233-239. [9] Salapaka, M. V., Chen, D. J., and Cleveland, J. P., Linearity of amplitude and phase in tapping-mode atomic force microscopy, Physical Review B, Vol. 61, No. 2, 2000, pp. 1106. [10] Sader, J. E., Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope, Journal of applied physics, Vol. 84, No. 1, 1998, pp. 64-76. [11] Neumeister, J. M., Ducker, W. A., Lateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers, Review of Scientific Instruments, Vol. 65, No. 8, 1994, pp. 2527-2531. [12] Delnavaz, A., Mahmoodi, S. N., Jalili, N., and Zohoor, H., Linear and nonlinear approaches towards amplitude modulation atomic force microscopy, Current Applied Physics, Vol. 10, No. 6, 2010, pp. 1416-1421. [13] Sader, J. E., Parallel beam approximation for V shaped atomic force microscope cantilevers, Review of Scientific Instruments, Vol. 66, No. 9, 1995, pp. 4583-4587. [14] J. Chen, R. K. Workman, D. Sarid, and R. Hoper, Numerical simulations of a scanning force microscope with a large-amplitude vibrating cantilever, Nanotechnology, Vol. 5, No. 4, 1994, pp. 199. [15] Van Eysden, C. A., Sader, J. E., Frequency response of cantilever beams immersed in compressible fluids with applications to the atomic force microscope, Journal of applied physics, Vol. 106, No. 9, 2009, pp. 94904. [16] Tamayo, J., Garcia, R., Deformation, contact time, and phase contrast in tapping mode scanning force microscopy, Langmuir, Vol. 12, No. 18, 1996, pp. 4430-4435. [17] Van Eysden, C. A., Sader, J. E., Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope: Arbitrary mode order, Journal of applied physics, Vol. 101, No. 4, 2007, pp. 44908. [18] Levy, R., Maaloum, M., Measuring the spring constant of atomic force microscope cantilevers: thermal fluctuations and other methods, Nanotechnology, Vol. 13, No. 1, 2002, pp. 33. [19] Schäffer, T. E., Cleveland, J. P., Ohnesorge, F., Walters, D. A., and Hansma, P. K., Studies of vibrating atomic force microscope cantilevers in liquid, Journal of applied physics, Vol. 80, No. 7, 1996, pp. 3622-3627. [20] Green, C. P., Sader, J. E., Frequency response of cantilever beams immersed in viscous fluids near a solid surface with applications to the atomic force microscope, Journal of applied physics, Vol. 98, No. 11, 2005, p-. 114913. [21] Liu, W., Yan, Y., Hu, Z., Zhao, X., Yan, J., and Dong, S., Study on the nano machining process with a vibrating AFM tip on the polymer surface, Applied Surface Science, Vol. 258, No. 7, 2012, pp. 2620 2626. [22] Gibson, C. T., Weeks, B. L., Abell, C., Rayment, T., and Myhra, S., Calibration of AFM cantilever spring constants, Ultramicroscopy, Vol. 97, No. 1, 2003, pp. 113-118.