XMM-Newton Calibration

Similar documents
RGS CALIBRATION STATUS

XMM-Newton Chandra Blazar Flux Comparison. M.J.S. Smith (ESAC) & H. Marshall (MIT) 7 th IACHEC, Napa, March 2012

Evaluation of the capabilities of the XMM-Newton SciSim from the EPIC calibration point-of-view. André Burzlaff, FH Aachen

Status of the EPIC calibration

ENERGY SCALE IN EPIC-PN TIMING MODE

XMM-Newton. XMM-Newton Science Analysis System 15.0 scientific validation. XMM-SOC-USR-TN-0026 Issue 1.0

Analysis of extended sources with the EPIC cameras

XMM-Newton SOC Technical Note

XMM-Newton Optical-UV Monitor: introduction and calibration status OM instrument and calibration

XMM-Newton. Routine Calibration Plan. Version Edited by: M. J. S. Smith. September 6, Revision history

XMM-Newton Calibration Technical Note

XMM-Newton. XMM-Newton Science Analysis System 12.0 scientific validation. XMM-SOC-USR-TN-0019 Issue 1.1

Serendipitous UV source catalogues for 10 years of XMM and 5 years of Swift

XMM-Newton Calibration Technical Note

EPIC Straylight. telescopes/sieves/rga revisited. David Lumb, Athena Study Scientist

Calibration Activities the MOS perspective

XMM-Newton. XMM-Newton Science Analysis System 17.0 scientific validation. XMM-SOC-USR-TN-0029 Issue 1.1

XMM-Newton - Chandra Synergy: Maximizing their Future Science Impact over the Next Decade

Serendipitous UV source catalogues for 10 years of XMM and 5 years of Swift

XMM. XMM-Newton Optical and UV Monitor (OM) Calibration Status. XMM-SOC-CAL-TN-0019 Issue 6.0

MONTE CARLO METHODS FOR TREATING AND UNDERSTANDING HIGHLY-CORRELATED INSTRUMENT CALIBRATION UNCERTAINTIES

GDR1 photometry. CU5/DPCI team

JEREMY DRAKE, PETE RATZLAFF, VINAY KASHYAP AND THE MC CALIBRATION UNCERTAINTIES TEAM MONTE CARLO CONSTRAINTS ON INSTRUMENT CALIBRATION

High Resolution X-Ray Spectra A DIAGNOSTIC TOOL OF THE HOT UNIVERSE

EPIC OBSERVATIONS OF BRIGHT BL LAC OBJECTS: WHAT CAN WE LEARN FROM THE X-RAY SPECTRA ABOUT THE ISM

arxiv: v1 [astro-ph.im] 14 Mar 2014

XMM-Newton Observations of the Isolated Neutron Star 1RXS J / RBS 1774

The 3XMM catalogue. Natalie Webb. Institut de Recherche en Astrophysique et Planétologie Toulouse, France

The High Energy Transmission Grating Spectrometer

Temporal &Spatial Dependency of the MOS RMF

Updated flux calibration and fringe modelling for the ACS/WFC G800L grism

The Behaviour of the XMM-Newton Background: From the beginning of the mission until May XMM-SOC-GEN-TN-0014 issue 3.10

The Effective Spectral Resolution of the WFC and HRC Grism

Calibration of ACS Prism Slitless Spectroscopy Modes

Major Releases: BG analysis web page with recommended information, papers, summary tables etc:

A Library of the X-ray Universe: Generating the XMM-Newton Source Catalogues

Absolute Flux Calibration for STIS First-Order, Low-Resolution Modes

Status and Calibration of the erosita X ray Telescope

Legacy IACHEC Working Group: the first steps

Study of the evolution of the ACS/WFC sensitivity loss

IBIS - IN FLIGHT CALIBRATION ACTIVITIES

Reduction procedure of long-slit optical spectra. Astrophysical observatory of Asiago

NICMOS Status and Plans

Problem Solving. radians. 180 radians Stars & Elementary Astrophysics: Introduction Press F1 for Help 41. f s. picture. equation.

Chandra Analysis of a Possible Cooling Core Galaxy Cluster at z = 1.03

NuStar has similar area kev, Astro-H better at E> 80 Kev

UVIT IN ORBIT CALIBRATIONS AND CALIBRATION TOOLS. Annapurni Subramaniam IIA (On behalf of the UVIT team)

Corrections for time-dependence of ACIS gain

Lab 4 Radial Velocity Determination of Membership in Open Clusters

On-flight calibration of the Swift-XRT telescope

NuSTAR observation of the Arches cluster: X-ray spectrum extraction from a 2D image

PACS spectroscopy Data Analysis

PACS Wavelength Switching AOT release note

The HST Set of Absolute Standards for the 0.12 µm to 2.5 µm Spectral Range

Chandra was launched aboard Space Shuttle Columbia on July 23, 1999!!!

PoS(INTEGRAL 2012)090

FLAT FIELDS FROM THE MOONLIT EARTH

Photometric Techniques II Data analysis, errors, completeness

Improving the Relative Accuracy of the HETGS Effective Area

PACS Spectrometer Wavelength Calibration

ACS CCDs UV and narrowband filters red leak check

Ivan Valtchanov Herschel Science Centre European Space Astronomy Centre (ESAC) ESA. ESAC,20-21 Sep 2007 Ivan Valtchanov, Herschel Science Centre

High-resolution spectroscopy of the low-mass X-ray binary EXO

The XMM-Newton EPIC background and the production of background blank sky event files. J. A. Carter and A. M. Read ABSTRACT

Gaia Photometric Data Analysis Overview

NAOYUKI TAMURA Subaru Instrument Astronomer Subaru Telescope, NAOJ

INTEGRAL/IBIS calibration status

NuSTAR Bringing the High Energy Universe into Focus. IACHEC 2016 Pune 1

Effective Areas. Herman L. Marshall Nov. 17, 2014

Analysis of Off-Nuclear X-Ray Sources in Galaxy NGC Sarah M. Harrison

The quest for Type 2 quasars: What are the X-ray observations of optically selected QSOs2 telling us?

Performance of the NICMOS ETC Against Archived Data

The Palermo Swift-BAT Hard X-ray Catalogue

A Cluster of Galaxies, Abell 496

The Bright Side of the X-ray Sky The XMM-Newton Bright Survey. R. Della Ceca. INAF Osservatorio Astronomico di Brera,Milan

PSF in-flight calibration for MOS 1 and MOS 2 cameras

arxiv:astro-ph/ v1 6 Oct 2002

Annapurni Subramaniam IIA UVIT-PMB Meeting 08 June 2012

Comets observed with XMM-Newton

Impressions: First Light Images from UVIT in Orbit

Modeling Pile-up. John E. Davis. CXC 5th Chandra/CIAO Workshop, October 2003

MWL. A Brief Advertisement Before Your Regularly Scheduled Program

Solar wind Magnetosphere Ionosphere Link Explorer: SoH X-ray Imager (SMILE-SXI)

SBC FLATS: PRISM P-FLATS and IMAGING L-FLATS

70µm Warm Campaign 10K Sensitivity Tests D. Frayer, A. Noriega-Crespo, S. Wachter, & D. Fadda (MIPS-IST) 2005-Jun-16, Version 1.

Impacts of focus on aspects of STIS UV Spectroscopy

Spectral Analysis of High Resolution X-ray Binary Data

arxiv:astro-ph/ v3 24 Mar 2006

The Magnificent Seven Similarities and Differences

Principal Component Analysis

On the calibration of WFCAM data from 2MASS

MEMORANDUM. Focal-Point: Point on the focal plane where the sharpest PSF is located.

Amateur Astronomer Participation in the TESS Exoplanet Mission

Bright gamma-ray sources observed by DArk Matter Particle Explorer

ACTIVE GALACTIC NUCLEI: optical spectroscopy. From AGN classification to Black Hole mass estimation

Transiting Exoplanet in the Near Infra-red for the XO-3 System

Exoplanetary transits as seen by Gaia

CONTENTS AIM OF THE PROJECT. INTRODUCTION: AGNs, XMM-Newton, ROSAT. TECHNIQUES: IDL, SQL, Catalogues RESULTS SUMMARY DESIRED OUTPUTS QUESTIONS

The Gaia Mission. Coryn Bailer-Jones Max Planck Institute for Astronomy Heidelberg, Germany. ISYA 2016, Tehran

Extraction of Point Source Spectra from STIS Long Slit Data

Transcription:

XMM-Newton Calibration Michael Smith, on behalf of XMM-SOC and Instrument Teams 18 th XMM-Newton Users Group Meeting, ESAC, 11 May 2017 ESA UNCLASSIFIED - For Official Use

Outline 1. Status of calibration related to the Users Group resolutions and recommendations 2. Calibration monitoring and improvements over the last 12 months 3. Additional future calibration activities ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 2

2016 UG Recommendations Recommendation 2016-06-08/01: As result of some recent investigations, there is now a requirement to implement an iterative adjustment to the parameters for the 2-D PSF. [ ] This activity needs to be considered as of the highest priority because of its impact on many other aspects of the calibration. Recommendation 2015-05-22/02: The UG identifies the following tasks in order of priority; 1. Cross-calibration of the responses of the XMM-Newton X-ray cameras and spectrometers. This is a longstanding issue, and it should be resolved as far as is possible in the near future. 2. Evidence for a shift in gain of the PN detectors, which is dependent on the quiescent background. This should be investigated and quantified, and a correction implemented. 3. Calibrated spectra from NuSTAR and XMM-Newton sometimes show a significant mis-match in spectral slope and offset above 3keV. This is a matter which the IACHEC should be encouraged to investigate. 4. Complete the calibration of the PN Burst Mode, RDPHA correction. Recommendation 2016-06-08/02: The time and energy reconstruction of the pn Timing mode should be studied with respect to recently observed discrepancies. ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 3

EPIC: PSF Investigations PKS 2155-304 - Piled-up - Annular extraction regions for EPIC Sample of non-piled-up on-axis sources Read el al. 2014 ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 4

EPIC: PSF Investigations NGC 5506 (Seyfert 2) Dominated (>90%) by point source emission. PN spectral comparison: annuli from 20-25 to 40-45 compared with 20 circle Other sources show similar results ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 5

EPIC: PSF Investigations Systematics in the current PSF modelling for all 3 XRTs Hopefully can be improved by tuning the PSF model parameters Source sample consists of 11 observations of bright non-piled-up point sources located at the nominal aim point 5-6 nested annuli being compared (up to 60 outer radius) 2 PSF model parameters (r0 and α) being varied changes affect off-axis angles < 3 ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 6

EPIC: PSF Investigations Iterative scheme for the empirical correction of XRT XPSF parameters: Per source: o o o o o o Extract spectrum from circular region Extract spectra from several nested annular regions Create respective RMFs Create respective ARFs Fit model to circular region spectrum Apply this as reference model to annular spectra, derive residuals For all annular spectra, and all sources, determine a suitable statistic: (di mi) 2 e i 2 i Modify ELLBETA parameters in order to minimise the statistic ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 7

EPIC: PSF Investigations ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 8

EPIC: PSF Investigations PN: MCG-5-23-16 ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 9

EPIC: PSF Investigations PN: Mkn 6 ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 10

EPIC: PSF Investigations MOS2: PKS B1334-127 ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 11

EPIC: PSF Investigations MOS1 MOS2 MOS1 MOS2 Public XRTn CCFs Candidate XRTn CCFs ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 12

2016 UG Recommendations Recommendation 2016-06-08/01: As result of some recent investigations, there is now a requirement to implement an iterative adjustment to the parameters for the 2-D PSF. [ ] This activity needs to be considered as of the highest priority because of its impact on many other aspects of the calibration. Recommendation 2015-05-22/02: The UG identifies the following tasks in order of priority; 1. Cross-calibration of the responses of the XMM-Newton X-ray cameras and spectrometers. This is a longstanding issue, and it should be resolved as far as is possible in the near future. 2. Evidence for a shift in gain of the PN detectors, which is dependent on the quiescent background. This should be investigated and quantified, and a correction implemented. 3. Calibrated spectra from NuSTAR and XMM-Newton sometimes show a significant mis-match in spectral slope and offset above 3keV. This is a matter which the IACHEC should be encouraged to investigate. 4. Complete the calibration of the PN Burst Mode, RDPHA correction. Recommendation 2016-06-08/02: The time and energy reconstruction of the pn Timing mode should be studied with respect to recently observed discrepancies. ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 13

Correction RGS: Effective Area Correction Algorithm and Implementation: Time and wavelength dependent correction RGS1 and RGS2, 1 st and 2 nd order For each 0.05 Å bin: t<0.538 P 1 + t 0.538 P 2 0.538 t<1.408 P 1 + P 2 + P 6 + t 0.538 0.870 1.408 t< 2.112 P 1 + P 2 + P 3 + P 6 + P 7 + P 3 t 1.408 0.704 2.112 t<2.816 P 1 + P 2 + P 3 + P 4 + P 6 + P 7 + t 2.112 0.704 t>2.816 P 1 + P 2 + P 3 + P 4 + P 5 + P 6 + P 7 +narrow gaussians at specific wavelengths P 4 P 5 Estimated calibration uncertainty of the effective area after the application of this correction: 1-2% in first order p 1 p2 p 6 p 3 p 7 t= rev 1000 P 1 correction at time 0 P 2 P 5 p 4 p 5 slopes P 6 discontinuity at cooling P 7 discontinuinity at change to RGS2 Single Node Readout mode implemented in SASv16 as a non-default option new CCF issued cooling RGS2 SNR 2112 2816 XMM-CCF-REL-340 revolution ESA UNCLASSIFIED - For Official Use J. Kaastra, C. de Vries XMM-Newton & J.W. den Calibration Herder M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 14

RGS: Effective Area Correction Testing: RGS1 v. RGS2 without correction 3C 273 @ rev 1465 with correction RGS1 RGS2 RGS1 RGS2 residuals with respect to best fit RGS1 model [two absorbed power-laws] ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 15

RGS: Effective Area Correction Testing: RGS1 v. RGS2 RGS1 3C 273 @ rev 1465 independent RGS1 and RGS2 fits RGS2 Model:[two absorbed power-laws without correction N H (10 20 ) +0.55 +0.95 2.28 0.56 1.89 0.79 +0.53 +0.77 1.85 0.52 2.19 0.69 Slope power-law #1 +0.15 +0.17 1.68 0.33 1.68 0.41 +0.22 +0.26 1.51 0.43 1.52 0.56 RGS1 RGS2 Norm (10-2 ) power-law #1 Slope power-law #2 +0.41 +0.42 3.61 1.02 3.52 1.28 +0.67 +0.78 3.13 1.20 3.20 1.52 +0.76 +1.18 3.61 0.70 3.69 0.97 +0.70 +0.93 3.16 0.52 3.20 0.65 with correction Norm (10-2 ) power-law #2 +0.94 +1.19 0.56 0.34 0.43 0.31 +1.14 +1.45 0.97 0.61 1.01 0.69 RGS1 RGS2 without correction ESA UNCLASSIFIED with correction - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 16

RGS: Effective Area Correction Testing: RGS2 / RGS1 Flux Ratio 7-37 Å 7-21 Å 24-37 Å without correction 0.988 ± 0.013 0.988 ± 0.011 0.989 ± 0.016 Based on observations of PKS 2155-304 and 3C 273 with correction 1.009 ± 0.008 1.013 ± 0.005 1.004 ± 0.007 ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 17

RGS: Effective Area Correction Testing: RGS to EPIC-pn Rectification Factors With effective area correction Based on 42 observations of bright BL Lac 1.037 ± 0.009 1.033 ± 0.008 0.992 ± 0.008 0.983 ± 0.012 EPIC-pn in Small Window mode in current CCF 1.031 ± 0.011 1.025 ± 0.016 0.985 ± 0.015 0.976 ± 0.013 ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 18

EPIC: Update of the CORRAREA Correction The CORRAREA tool was implemented in SAS 14 (autumn 2014): Applies an empirical correction to the EPIC effective areas. Can be used to evaluate the impact that the current relative EPIC A eff uncertainties have on astrophysical parameters derived from spectral fitting. Currently, a non-default SAS option. A recalibration and full validation of the CORRAREA correction is currently being undertaken: Based on SAS 15.1, and latest calibration (as of Oct 2016). Revised screening: common GTIs, background selections, pile-up evaluation. Largely automated pipeline from data reduction to spectral and residual fitting. A new CORRAREA correction is close to release ( summer 2017). Outlook: Include a wider sample of sources, observing modes (LW, SW) and filters (Thick) ( autumn 2017). Cross-mission comparison in order to justify absolute A eff correction. ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 19

Mirrors: Effective Area Simulations In mid 2016 an investigation (by D. Lumb) was started into possible unaccounted for mirror contamination present pre-launch. Using industry reports on expected contamination, SciSim was used to compare telescope effective areas. Results show the currently implemented values are inconsistent. The discrepancies are telescope-dependent, implying absolute and relative changes to the EPIC (and RGS) effective area calibration. Progress has been made, resulting in preliminary estimates based on the best knowledge of the telescope contamination. Assuming this contamination is present after launch this would mean: o Absolute changes in telescope effective area: ~ 2-4%. o Relative changes between EPICs (esp. XRT3 and XRT1/2): ~ 0 3%. ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 20

2016 UG Recommendations Recommendation 2016-06-08/01: As result of some recent investigations, there is now a requirement to implement an iterative adjustment to the parameters for the 2-D PSF. [ ] This activity needs to be considered as of the highest priority because of its impact on many other aspects of the calibration. Recommendation 2015-05-22/02: The UG identifies the following tasks in order of priority; 1. Cross-calibration of the responses of the XMM-Newton X-ray cameras and spectrometers. This is a longstanding issue, and it should be resolved as far as is possible in the near future. 2. Evidence for a shift in gain of the PN detectors, which is dependent on the quiescent background. This should be investigated and quantified, and a correction implemented. 3. Calibrated spectra from NuSTAR and XMM-Newton sometimes show a significant mis-match in spectral slope and offset above 3keV. This is a matter which the IACHEC should be encouraged to investigate. 4. Complete the calibration of the PN Burst Mode, RDPHA correction. Recommendation 2016-06-08/02: The time and energy reconstruction of the pn Timing mode should be studied with respect to recently observed discrepancies. ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 21

PN: Quiescent Background Gain Correction Details of the quiescent background gain correction (QBGC) were presented at the 2016 Users Group meeting. In order to correct the PN gain, the discarded line rate is used as proxy for the quiescent background. Original implementation envisaged the use of an observation averaged rate, already stored in the events file (NDISCLIN keyword). However, the QB may vary significantly within an observation, necessitating the use of the instantaneous discarded line rates, included in the housekeeping data stream. This requires a fundamentally different implementation at S/W level. Main issue is the robust handling of telemetry gaps, outlier values, intrinsic noise. Aim is for SAS 17 implementation (end of 2017). ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 22

2016 UG Recommendations Recommendation 2016-06-08/01: As result of some recent investigations, there is now a requirement to implement an iterative adjustment to the parameters for the 2-D PSF. [ ] This activity needs to be considered as of the highest priority because of its impact on many other aspects of the calibration. Recommendation 2015-05-22/02: The UG identifies the following tasks in order of priority; 1. Cross-calibration of the responses of the XMM-Newton X-ray cameras and spectrometers. This is a longstanding issue, and it should be resolved as far as is possible in the near future. 2. Evidence for a shift in gain of the PN detectors, which is dependent on the quiescent background. This should be investigated and quantified, and a correction implemented. 3. Calibrated spectra from NuSTAR and XMM-Newton sometimes show a significant mis-match in spectral slope and offset above 3keV. This is a matter which the IACHEC should be encouraged to investigate. 4. Complete the calibration of the PN Burst Mode, RDPHA correction. Recommendation 2016-06-08/02: The time and energy reconstruction of the pn Timing mode should be studied with respect to recently observed discrepancies. ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 23

EPIC-pn / NuSTAR Comparison Mean ratios Comparison of 18 AGN spectra: PN imaging modes Strictly simultaneous PN-NuSTAR data Models fit to PN Systematic NuSTAR residuals A. Gokus Slope differences of ~0.15 However: Recent NuSTAR results (Madsen et al. 2017, comparing focused with non-focused measurements of the Crab) confirm NuSTAR normalisation underestimated by ~ 10%. Change in PSF parameters may affect EPIC spectral slope. ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 24

2016 UG Recommendations Recommendation 2016-06-08/01: As result of some recent investigations, there is now a requirement to implement an iterative adjustment to the parameters for the 2-D PSF. [ ] This activity needs to be considered as of the highest priority because of its impact on many other aspects of the calibration. Recommendation 2015-05-22/02: The UG identifies the following tasks in order of priority; 1. Cross-calibration of the responses of the XMM-Newton X-ray cameras and spectrometers. This is a longstanding issue, and it should be resolved as far as is possible in the near future. 2. Evidence for a shift in gain of the PN detectors, which is dependent on the quiescent background. This should be investigated and quantified, and a correction implemented. 3. Calibrated spectra from NuSTAR and XMM-Newton sometimes show a significant mis-match in spectral slope and offset above 3keV. This is a matter which the IACHEC should be encouraged to investigate. 4. Complete the calibration of the PN Burst Mode, RDPHA correction. Recommendation 2016-06-08/02: The time and energy reconstruction of the pn Timing mode should be studied with respect to recently observed discrepancies. ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 25

PN: Timing & Burst Mode Issues PN Timing Mode observations show several cases of sources with: larger than expected residuals at instrumental edges significant differences in line energies with respect to e.g. grating data (up to 70 ev at ~ 6 kev) Sources are in the moderate count rate regime. Possible issue with rate dependent correction in Timing Mode (and Burst Mode). The chain of corrections affecting the TI & BU mode energy scale is being systematically evaluated. Work in progress Rate dependent correction (pattern recognition) Find event patterns Rate dependent correction (applied to charges) Gain correction Mode-specific gain correction CTI correction Long-term CTI correction CCD offset correction ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 26

Outline 1. Status of calibration related to the Users Group resolutions and recommendations 2. Calibration monitoring and improvements over the last 12 months 3. Additional future calibration activities ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 27

Summary of Calibration Monitoring EPIC bad pixels (XMM-CCF-REL-338) EPIC background and offset maps (XMM-CCF-REL-339) EPIC energy scale (XMM-CCF-REL-336) EPIC variable boresight (XMM-CCF-REL-343) EPIC-MOS contamination EPIC-pn flux stability EPIC-pn timing OM sensitivity degradation (XMM-CCF-REL-346) OM photometric stability OM grism flux stability OM astrometry OM variable boresight (XMM-CCF-REL-343) RGS bad columns (XMM-CCF-REL-347) RGS wavelength scale RGS CTI & gain (XMM-CCF-REL-345) RGS background RGS contamination RGS flux stability RGS offsets (XMM-CCF-REL-342) ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 28

RGS: Contamination Monitoring Carbon contamination layer building-up slowly No changes in the trend C. de Vries ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 29

RGS: Bad Surface Monitoring << 1% of detector surface < 1.5% of detector surface XMM-SOC-CAL-TN-0209 C.Gabriel ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 30

RGS: Wavelength Scale Monitoring RGS 1 1 st order RGS 2 : 5 må 1 st order : 5 må Bright sample 85 observations of AB Dor, Capella, HR 1099 and Procyon Faint sample 70 observations of fainter emission line stars RGS 1 2 nd order : 4 må RGS 2 2 nd order : 4 må Heliocentric and Sun angle corrections applied; most recent XMM variable boresight ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 31

MOS: Contamination Monitoring Primary monitoring source: SNR 1E0102 Contamination status shows no change in trend: MOS1 stable MOS2 steadily increasing ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 32

OM: Time Sensitivity Degradation Originally based on linear fit to standard stars: OM_PHOTTONAT_0005.CCF Now based on a quadratic fit to selected catalogue sources: OM_PHOTTONAT_0006.CCF ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 33

OM: Time Sensitivity Degradation Testing of the new correction on standard stars: + old correction new correction ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 34

OM: Repeatability of Filter Photometry SAS 16 data processing: Count rates (cts/s) of standard stars observed regularly since 2001: Star Nobs UVW2 UVM2 UVW1 U B V GD 153 14 83.1 161.8 329.5 420.5 283.5 71.4 error (%) 1.4 1.5 0.8 1.4 1.0 2.1 Hz 2 17 23.8 48.3 111.7 168.8 148.8 43.7 error (%) 2.0 1.3 1.3 0.9 0.8 2.9 BPM 16274 32 14.7 30.3 72.9 112.7 107.8 33.0 error (%) 1.7 1.2 1.0 0.8 0.8 2.2 ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 35

OM: Serendipitous UV Source Survey New version 3 of the XMM-Newton Serendipitous Source Survey ( the OM Catalogue ): SUSS3 Released in March 2017 Observations till mid-2015: 7866 XMM-Newton pointings 6,9 million entries 4,8 million sources 0,9 million sources with multiple observations Full reprocessing with SAS 15 & new time-dependent sensitivity degradation correction (OM_PHOTONAT_0006.CCF) New flag: Sky_Image to identify sources detected in mosaic / stacked images Available through the ESA XSA: query I/F or full catalogue download Catalogue sources can be overlaid in the ESA-Sky utility ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 36

Multi-wavelength study of the Crab (Dubner et al., ApJ, 2017) UV data from the XMM-Newton Optical Monitor UVW1 filter (291 nm): 75 exposures (2001 2015) 221 ks exposure time ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 37

Outline 1. Status of calibration related to the Users Group resolutions and recommendations 2. Calibration monitoring and improvements over the last 12 months 3. Additional future calibration activities ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 38

Additional Future Calibration Activities EPIC-pn: Include Cu-Ka fluorescence emission (8.0 kev) in the long-term CTI correction; will complement the existing data points at 1.5 kev (Al-Ka) and 5.9 kev (Mn-Ka). OM: Continued study of time-dependent sensitivity degradation. RGS: Re-evaluation of effective area corrections. Assessment of background templates and background correction methods. Cross-Calibration: Streamlining the XMM-Newton Cross Calibration Archive in order to improve flexibility in validating calibration products. 51 targets 228 exposures on and off-axis point and extended sources ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 39

Summary of Calibration Plans & Activities EPIC encircled energy correction: new XRTn XPSF parameters Summer 2017 EPIC CORRAREA: recalibration Summer 2017 extended validation Autumn 2017 EPIC-pn quiescent background gain correction in SAS 17 End of 2017 EPIC-pn empirical RMF modelling Implications of mirror contaminant simulations In progress Re-evaluation of EPIC-pn fast mode energy scale corrections ESA UNCLASSIFIED - For Official Use XMM-Newton Calibration M. Smith 18 th XMM-Newton Users Group Meeting 11/05/2017 Slide 40