HEAT TRANSFER AND EXCHANGERS

Similar documents
INTRODUCTION: Shell and tube heat exchangers are one of the most common equipment found in all plants. How it works?

Thermal Unit Operation (ChEg3113)

HEAT TRANSFER. Mechanisms of Heat Transfer: (1) Conduction

DESIGN AND COST ANALYSIS OF HEAT TRANSFER EQUIPMENTS

Analyzing Mass and Heat Transfer Equipment

Chapter 11: Heat Exchangers. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Introduction to Heat and Mass Transfer

INSTRUCTOR: PM DR MAZLAN ABDUL WAHID

Overall Heat Transfer Coefficient

Design of Heat Transfer Equipment

ANSI/AHRI Standard (Formerly ARI Standard ) 2006 Standard for Performance Rating of Desuperheater/Water Heaters

HEAT TRANSFER. PHI Learning PfcO too1. Principles and Applications BINAY K. DUTTA. Delhi Kolkata. West Bengal Pollution Control Board

Phone: , For Educational Use. SOFTbank E-Book Center, Tehran. Fundamentals of Heat Transfer. René Reyes Mazzoco

: HEAT TRANSFER & EVAPORATION COURSE CODE : 4072 COURSE CATEGORY : B PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 70 CREDIT : 5 TIME SCHEDULE

Designing Steps for a Heat Exchanger ABSTRACT

Design and Temperature Analysis on Heat Exchanger with TEMA Standard Codes

Thermal Unit Operation (ChEg3113)

23 1 TYPES OF HEAT EXCHANGERS

Principles of Food and Bioprocess Engineering (FS 231) Problems on Heat Transfer

Heat Transfer Equipment

S.E. (Chemical) (Second Semester) EXAMINATION, 2011 HEAT TRANSFER (2008 PATTERN) Time : Three Hours Maximum Marks : 100

If there is convective heat transfer from outer surface to fluid maintained at T W.

c Dr. Md. Zahurul Haq (BUET) Heat Exchangers: Rating & Sizing - I ME 307 (2017) 2 / 32 T666

T718. c Dr. Md. Zahurul Haq (BUET) HX: Energy Balance and LMTD ME 307 (2018) 2/ 21 T793

Examination Heat Transfer

Heat and Mass Transfer Unit-1 Conduction

Heat processes. Heat exchange

طراحی مبدل های حرارتی مهدي کریمی ترم بهار HEAT TRANSFER CALCULATIONS

How can we use Fundamental Heat Transfer to understand real devices like heat exchangers?

ESRL Module 8. Heat Transfer - Heat Recovery Steam Generator Numerical Analysis

Convection. forced convection when the flow is caused by external means, such as by a fan, a pump, or atmospheric winds.

Multiple pass and cross flow heat exchangers

Shell and Tube Heat Exchange Fundamentals, Design and Case Studies

Applied Heat Transfer:

Mathematical Modelling for Refrigerant Flow in Diabatic Capillary Tube

HEAT EXCHANGER. Objectives

8.1 Technically Feasible Design of a Heat Exchanger

Arctice Engineering Module 3a Page 1 of 32

VISIMIX TURBULENT. TACKLING SAFETY PROBLEMS OF STIRRED REACTORS AT THE DESIGN STAGE.

CHAPTER 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

Applied Fluid Mechanics

Heat and Mass Transfer Prof. S.P. Sukhatme Department of Mechanical Engineering Indian Institute of Technology, Bombay

Applied Fluid Mechanics

Estimating number of shells and determining the log mean temperature difference correction factor of shell and tube heat exchangers

PHYSICAL MECHANISM OF CONVECTION

Plant Design LECTURE 8: REBOILER CIRCUIT DESIGN. Daniel R. Lewin Department of Chemical Engineering Technion, Haifa, Israel

Specific heat capacity. Convective heat transfer coefficient. Thermal diffusivity. Lc ft, m Characteristic length (r for cylinder or sphere; for slab)

HEAT AND MASS TRANSFER. List of Experiments:

PLATE & FRAME HEAT EXCHANGER

Chapter 7: External Forced Convection. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Heat Exchanger Design

S.E. (Chemical) (Second Semester) EXAMINATION, 2012 HEAT TRANSFER (2008 PATTERN) Time : Three Hours Maximum Marks : 100

External Forced Convection. Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

Tutorial 1. Where Nu=(hl/k); Reynolds number Re=(Vlρ/µ) and Prandtl number Pr=(µCp/k)

Principles of Food and Bioprocess Engineering (FS 231) Exam 2 Part A -- Closed Book (50 points)

HEAT TRANSFER 1 INTRODUCTION AND BASIC CONCEPTS 5 2 CONDUCTION

Countercurrent heat exchanger

Heat transfer analysis in wire bundles for aerospace vehicles

Chemical and Biomolecular Engineering 150A Transport Processes Spring Semester 2017

Journal of NUCLEAR SCIENCE and TECHNOLOGY, Vol. 41, No. 7, p (July 2004)

Experiment 1. Measurement of Thermal Conductivity of a Metal (Brass) Bar

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

Chapter: Heat and States

1. Introduction. Technical presentation of the Bernoulli Filter

Latest Heat Transfer

COVENANT UNIVERSITY NIGERIA TUTORIAL KIT OMEGA SEMESTER PROGRAMME: MECHANICAL ENGINEERING

Ministry of Higher Education And Scientific Research. University Of Technology Chemical Engineering Department. Heat Transfer

CHAPTER 3 SHELL AND TUBE HEAT EXCHANGER

C ONTENTS CHAPTER TWO HEAT CONDUCTION EQUATION 61 CHAPTER ONE BASICS OF HEAT TRANSFER 1 CHAPTER THREE STEADY HEAT CONDUCTION 127

1. Nusselt number and Biot number are computed in a similar manner (=hd/k). What are the differences between them? When and why are each of them used?

Applied Fluid Mechanics

Innovation in. Motionless Mixers

Effect of flow velocity on the process of air-steam condensation in a vertical tube condenser

CHAPTER FOUR HEAT TRANSFER

Chapter 7: External Forced Convection

4.1 Derivation and Boundary Conditions for Non-Nipped Interfaces

DESIGN OF A SHELL AND TUBE HEAT EXCHANGER

Chapter 10: Boiling and Condensation 1. Based on lecture by Yoav Peles, Mech. Aero. Nuc. Eng., RPI.

Forced Convection: Inside Pipe HANNA ILYANI ZULHAIMI

Nusselt Correlation Analysis of Single Phase Steady-State Flow through a Chevron Type Plate Heat Exchanger

Heat Transfer Performance in Double-Pass Flat-Plate Heat Exchangers with External Recycle

Chapter 7 The Energy Equation

Investigation of Heat Transfer on Smooth and Enhanced Tube in Heat Exchanger

Piping Systems and Flow Analysis (Chapter 3)

Thermal Unit Operation (ChEg3113)

Experimental Analysis of Double Pipe Heat Exchanger

Chapter 3 NATURAL CONVECTION

WTS Table of contents. Layout

MAHATMA GANDHI MISSION S JAWAHARLAL NEHRU ENGINEERING COLLEGE, HEAT TRANSFER LABORATORY MANUAL

Thermal Analysis. with SolidWorks Simulation 2013 SDC. Paul M. Kurowski. Better Textbooks. Lower Prices.

Heat and Mass Transfer Prof. S. P. Sukhatme Department of Mechanical Engineering Indian Institute of Technology, Bombay Lecture No.

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

PERFORMANCE ANALYSIS OF SHELL AND TUBE HEAT EXCHANGERS USING AN EDUCATIONAL APPLICATION

Thermal Systems. What and How? Physical Mechanisms and Rate Equations Conservation of Energy Requirement Control Volume Surface Energy Balance

UNIT II CONVECTION HEAT TRANSFER

CFD ANALYSIS OF HEAT TRANSFER FOR TUBE-IN- TUBE HEAT EXCHANGER

ME 331 Homework Assignment #6

Lectures on Applied Reactor Technology and Nuclear Power Safety. Lecture No 6

Figure 1.1. Relation between Celsius and Fahrenheit scales. From Figure 1.1. (1.1)

ECH 4224L Unit Operations Lab I Thin Film Evaporator. Introduction. Objective

Transcription:

HEAT TRANSFER AND EXCHANGERS Although heat-transfer rates can be computed with reasonable accuracy for clean or new pipe, the effect of dirty or corroded pipe surfaces cannot he satisfactorily estimated. With the greatest possible care, the accuracy with which the rate of heat transfer can be computed is probably not better than ±5 per cent. There are three common methods of transferring heat, viz., radiation, conduction through solids, and conduction through fluids. In practice a combination of two or even all of these methods may take place simultaneously. CONDUCTION THROUGR SOLIDS Conduction is the most simple method of heat transfer. Newton's fundamental law of resistances and driving forces, if applied to conduction, takes the following form: Q = k x (T 2 T 1 ) A L where Q = Btu heat transferred per hr A = area of surface, sq ft T2 and TI = temperatures at hot and cold surfaces k = conductivity as Btu/('F diff.)(sq ft)(hr) for 1 ft thickness ( Refer Tables 17-1 and 17-2) L = thickness, ft In using Newton's law, the factor L / k may be considered to be a resistance (R) to the driving force represented by the temperature difference (T 2 T 1 ) = T Q / A = T / R (17-2) Where R = L / k

Several materials usually compose the vessel or wall through which heat is being conducted, and hence conduction problems involve the conduction of heat through a series of resistances. The quality of heat Q that passes through each material is the same, but the temperature difference across each material will be different for each material. Suppose a wall is composed of three materials having conductivities of k1, k2, and k3, having thickness. of L1, L2 and L3 and having temperature differences of T1, T2 and T3.. Also

The temperature difference across the three materials is the sum of the three individual differences.

Thus, we find that resistance to the flow of Heat corresponds exactly to resistances to the flow of electricity through a series electrical circuit. For the special case of heat transfer through a flat wall, the area ratio in each resistance term is unity, i.e., A1 = A2 = As etc. The temperature differences are directly proportional to the resistances to flow, so that T: T 1 : T 2 : T 3 :: R:R 1 :R 2 :R 3

Heat losses from many petroleum equipment are so small compared with other heat quantities that for design work the approximations of Table 17-3 are usually adequate. ( Since the outside temperature cannot be easily measured, the air temperature is usually used, but this involves the conductivity of a film of stagnant air at the wall (see Example 17-5). Pipe Insulation. : In the case of pipe insulation the area through which heat is transferred is not constant. If the thickness of the material is small, compared with the diameter, the arithmetic average of the larger area and the smaller area may be used. The arithmetic mean area may be used with an error of only 4 per cent for all cylindrical vessels and for pipe sizes down to about 2 in. if standard insulation is used. If the thickness is great compared with the diameter, the logarithmic mean area must he used in the denominator of the resistance term.

CONDUCTION THROUGH FLUID FILMS (CONVECTION) As indicated earlier, all fluids are bounded at the retaining walls by a film of stagnant fluid. Heat must be transferred through these films by conduction. The films are very thin, their thickness L cannot be easily measured, and hence the thickness L which is involved in the resistance of the film cannot be determined directly. In order to avoid this difficulty, the resistances of fluid films have been correlated by expressing the resistance as 1/h in which h is the film coefficient of heat transfer. From commonly accepted heat transfer coefficients the apparent film thickness varies from about 0.1 for gases to about 0.0001 for condensing steam. If the conduction equation is applied to the transfer of heat from a fluid into a solid partition wall and into another fluid, the conduction equation takes the following form: In this equation, ho and hi represent the outside and inside film coefficients of heat transfer of the two fluids; L w and k w. the thickness and conductivity of the partition wall; Ro and Ri the resistances due to corrosion, dirt, or roughness of thelsurfaces; and Ao., Ai, and Aw. represent the areas of the wall at the outside, at the inside, and at about the mean of the two (A.). Two fouling resistances are used throughout but most of the literature fails to indicate whether one or both factors are being reported. Accordingly, a single fouling resistance R d, which is the sum of Ro. and Ri, will be used in this derivation and no correction for outside and inside surfaces will be made except in such necessary cases as fin-tube resistances. The resistance in the denominator may, for convenience, be added and the total equals 1/Ho. or 1/Hi, in which Ho is the over-all transfer rate based on outside surface.

If one film Coefficient is small compared with the other coefficients, the resistance l/h which corresponds to it will be proportionally large. In such a ease the value of the over-all coefficient will be nearly the same as the small film coefficient corrected to the reference surface. For the same reason the resistance of the metal wall may often be neglected. Example Over-all Coefficient of Heat Transfer. Heat is being transferred from a gas through the walls of a standard 2-in. pipe and into water that is flowing on the'inside of the pipe. ho = 6, h w = 500, and k for the pipe wall is 25 [see Eq. (17-8a)l. Thus, the resistance of the metal wall and the water film could be neglected with an error of only 1.66 per cent.

If the pipe could be made of copper,(an excellent conductor of heat (k = 220)) the over-all coefficient would be scarcely changed: Ho = 1 = 5.92 0.1667 + 0.000062 + 0.0023 Logarithmic mean temperature. difference. In exchangers, etc., the temperature difference between the two fluids is not constant because a one fluid is heated the other is cooled. The arrows of Fig. 17-2 indicate the direction of the flow of the fluids with respect to one another for the common arrangements of flow. Almost all commercial equipments are designed for countercurrent flow, but the conditions indicated in d and e are closely simulated in steam heaters and in coil-in-box coolers. Flow arrangement Fig 17.2c shows a single shell-side pass but two tube passes.figure 17-2f indicates condensing of a hydrocarbon mixture followed by cooling of the condensate, all in the same equipment. Such a condition should he considered as two separate zones, each with its own mean temperature difference.. For the simplified case of a constant transfer coefficient and constant specific heats for the two fluids, the logarithmic mean temperature difference is valid: Θ = log mean temp diff = larger temp diff smaller tem diff log e (larger temp diff/smaller temp diff.) The logarithm to the base 10 may be converted to base e by multiplying by 2.3. Experimental tests indicate that logarithmic mean temperature difference is not exact for either streamline or turbulent flow of oils, but no means of easily handling the true case are available.

Example 17-3. The Logarithmic Mean-temperature Difference. An oil is to be cooled from 200 to 100'F by water that enters at 60 and leaves at 80'F.What is the logarithmic mean temperature? (200-80) - (100-60) log e (120/40 ) = 80 /1.1 = 72.8 of The arithmetic, temperature difference would be in error by about 10 per cent. Arithmetic T = (120 + 40) / 2 = 80 of If the ratio of the temperature differences is less than 2, the arithmetic average temperature difference may be used with an error of only 4 per cent.

Multipass Flow. True countercurrent flow is not attained in most multi pass exchangers. In such exchangers, the fluid is guided back and forth in the shell by means of longitudinal baffles, and in the tubes by means of partitions in the heads. Efficiencies (or multipliers for the log- arithmetic mean difference) are shown in Figs. 17-4 and 17-51 in terms of R and P. T I T 2 t 2 - t 1.R = P = t 2 t 1 T 1 - t 1 Where T I = inlet temperature, shell side T 2 = outlet temperature,shell side t 1 = inlet temperature, tube side t 2 = outlet temperature, tube side Figure's 17 4 and 17-5 extend down to an F factor of only 0.8 because it is lot good practice to use lower values., The correction factors are not applicable if a sudden change in phase occurs, so abrupt as to cause a sharp break in the temperature curve of one of the fluids.

Number of Passes. In order to obtain a high velocity, it is usually necessary to arrange the flow of liquid through the tubes so that the fluid passes through one section of tubes and then returns through another section of tubes. As many as 16 sections or passes have been used. The same effect is produced on the outside of the tubes by means of baffles.- In the past, exchangers have been built with as many as six shell side passes and even more passes within the tubes. Today there is a tendency to utilize only one or two shell passes because of mechanical difficulties with leaks and with the removal of the large tube bundles of highly multi pass exchangers. If more passes are used, the conditions of true countercurrent flow may not be attained and the mean temperature difference and total heat transferred may be decreased (Figs. 17-4 and 17-5) even though higher shell and tube velocities are maintained. Bowman, Mueller, and Naglel question the economy of an exchanger design in which the mean-temperature-difference correction factor is under 0.8. As exceptions, multiple tube passes are an advantage if several exchangers are used in series and in the case of vapor condensers. In an attempt to obtain true countercurrent flow, some refiners require single-pass exchangers for all services, but the cost of several small shells, as against the cost of fewer large shells with several passes, is great. In addition, a single-tube-pass floatinghead exchanger requires some type of packed joint or internal expansion joint. From an operating standpoint, the single-pass exchanger has many advantages: 1. Countercurrent flow is attained. 2. Cleaning is facilitated because one unit at a time can be removed from the system and cleaned without markedly interrupting continuous operation or changing the operating conditions. 3. For the same reason the repair of leaky tubes is facilitated. 4. Small tube bundles can be more easily removed and more easily flushed or cleaned. 5. Large multiple - pass units are bulky and cannot be easily installed and removed.

In the case of vacuum partial condensers, the weight of the several units of condenser often amounts to over 50 tons. This great bulk at a height of 40 ft or more is indeed awkward. 6. If many units (double-pipe or. fin-tube) are in service (some refiners have hundreds of units), they may be disconnected and reassembled to meet changes that are constantly occurring in services or operating conditions. Double-pipe fin-tube equipment' meets nearly all these requirements. Even 20 of these units are sometimes used for a single exchanger operation, and they may be assembled in many combinations, such as (1) 5 units in parallel, 4 units in series, and vice versa, (2) 10 units in parallel, 2 units in series, and vice versa, (3) all in parallel or all in series, etc. Which Material through Tubes. Fixed rules cannot be given because many of the factors or reasons are at variance with one another. Dirty stocks are passed (1) Through the tubes, because they can be easily cleaned., particularly if the tube bundle cannot be removed. but (2) Through shell if the tubes cannot be cleaned (hairpin bundles) or if large amounts of coke or debris are present which can he accumulated in the shell and removed by dumping the shell. High pressure fluids, corrosive stocks and water are sent through the tubes because the strength of small diameter ( and thickness ) surpasses that of the shell, because corrosion resistant tubes are relatively cheap and because corrosion or water scale can easily be removed, Ordinarily, exchanger shells are built for a pressure of only 125 to 150 psig. Large-volume fluids (vapors) are passed through the shell so that adequate space is available, but small volume fluids are also passed through the shell where cross baffles can be used to increase the transfer rate without producing an excessive pressure drop.

Vapors that contain non condensable gases are sent through the tubes so that the accumulation of non condensables will be swept out. If the pressure drop must be low the material is sent through the.shell and the same applies to viscous or low-transfer-rate fluids :because maximum transfer rates for a fixed pressure drop can be obtained by the use of cross baffles in the shell.. In fin-tube equipment, high-pressure, dirty, or corrosive stocks are sent through the fin tube because it is relatively cheap, can be easily cleaned, and has a higher strength than the outside tube. Obviously, it is advantageous to keep the low-transfer-rate fluid in contact with the fins of a fin-tube equipment.

Analysis of Heat Exchanger Performance. The Analysis of Performance in an Existing 1-2 Exchanger. When all the pertinent equations are used to calculate the suitability of an existing exchanger for given process conditions, it is known as rating an exchanger. There are three significant points in determining the suitability of an existing exchanger for a new service. 1. What clean coefficient Uc can be "performed / achieved " by the two fluids as the result of their flow and individual film coefficients hio, and ho? 2. From the heat balance Q = WC(T I - T 2 ) = wc(t 2 - t 1 ), known surface A, and the true temperature difference for the process temperatures a value of the design or dirty coefficient, U D is obtained. Uc must exceed Ud sufficiently so that the dirt factor, which is a measure of the excess surface, will permit operation of the exchanger for a reasonable period of service. 3. The allowable pressure drops for the two streams may not be exceeded. When these are fulfilled, an existing exchanger is suitable for the process conditions for which it has been rated. In starting a calculation the first point which arises is to determine whether the hot or cold fluid should be placed in the shell. There is no fast rule. One stream may be large and the other small, and the baffle spacing may be such that in one instance the shell-side flow area a. will be larger. Fortunately any selection can be checked by switching the two streams and seeing which arrangement gives the larger value of Uc without exceeding the allowable pressure drop. Particularly in preparation for later methods there is some advantage, however, in starting calculations with the tube side, and it may be well to establish the habit. The detailed steps in the rating of an exchanger has been shown in earlier chapters. The subscripts s and t are used to distinguish between the shell and tubes, and for the outline the hot fluid may be assumed to be in the shell.

By always placing the hot fluid on the left the usual method of computing the LMTD may be retained. The Calculation of an Existing 1-2 Exchanger. Process conditions required

The Efficiency of an Exchanger. In the design of many types of apparatus it is frequently desirable to establish a standard of maximum performance. The efficiency is then defined as the fractional performance of an apparatus delivering less than the standard. Dodge' gives the definition of the efficiency of an exchanger as the ratio of the quantity of heat removed from a fluid to the maximum which might have been removed. Using the usual nomenclature, which is identical with the temperature group S and presumed that t 2 = T 1. Depending upon whether the hot or cold terminal approaches zero, the efficiency may also be expressed by Although there is merit to this definition from the standpoint of thermo dynamics there is a lack of realism in an efficiency definition which involves a terminal difference and a temperature difference of zero. It is the same as defining the efficiency as the ratio of the heat transferred by a real exchanger to an exchanger with infinite surface. In process heat transfer there is another definition which is useful. The process temperatures are capable of providing a maximum temperature difference if arranged in counter flow. There appears to be some value in regarding the efficiency of an exchanger as the ratio of the temperature difference attained by any other exchanger to that for.true counter flow. This is identical with F T, which proportionately influences the surface requirements. It will be seen that other flow arrangements besides 1-2 parallel flow - counter flow can be attained in tubular equipment and by which the value of F T may be increased for given process temperatures. These obviously entail flow patterns which approach true counter flow more closely than the 1-2 exchanger.

Reference: 'Dodge, B. F., "Chemical Engineering Thermodynamics," McGraw-Hill Book Company, Inc., New York, 1944.