Reliability and Improvements of Water Titration by the Karl Fischer Technique

Similar documents
Comparing Various Moisture Determination Methods for Power Transformers MAIK KOCH*, MICHAEL KRÜGER, STEFAN TENBOHLEN

CIGRE SC A2 & D1 JOINT COLLOQUIUM 2011, KYOTO JAPAN. Water Saturation Limits and Moisture Equilibrium Curves of Alternative Insulation Systems

[RNH]SO3CH3 [RNH]SO 4 CH [RNH]I

Aquagent. The Scharlau comprehensive pyridine-free solutions range for a reliable Karl Fischer Titration

WATER. Brighter. Determination. Aquastar reagents for brilliant Karl Fischer titration results.

Analytix. HYDRANAL Product Line Overview

Diagnosis of Electrical Performance and Aging Behavior of Transformer Dielectrics

Karl-Fischer Titration the method for determining water

Theory of Headspace Sampling

Karl Fischer Volumetric Titration Theory and Practice

Citric Acid Analysis L-6-1. MOISTURE (Karl Fischer)

COMPARATIVE EVALUATION OF BREAKDOWN STRENGTH OF NATURAL ESTERS AND MINERAL OIL

Karl Fischer Titration Of Food : Towards Complete Automation

Corn Sugar (crude & refined) Analysis F MOISTURE (Karl Fischer)

Glossary of Common Laboratory Terms

J.T.Baker Brand HYDRA-POINT KARL FISCHER REAGENTS. Europe Middle East Africa

Application Determination of water in petrochemistry products using Titrator TitroLine 7500 KF trace

Method for the determination of 1,3-butadiene

CHEMISTRY HIGHER LEVEL

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

á921ñ WATER DETERMINATION

Background on Solubility

Biology Basics Unit Review Guide

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Experiment 1: Thin Layer Chromatography

Hy = KFt Ori x Acy. HYDRANAL Product Overview Guide. Hydranal TM. Karl Fischer titration. Research Chemicals. Discover the perfect formula

Hy + Hw = Cy + Inv. Discover the perfect formula. Hydranal TM Honeywell Consistency Innovation

Prelab Reading Assignment: Laboratory Techniques in Organic Chemistry, 4 th Ed. Chapter 19

GENERAL INSTRUCTIONS GENERAL PREPARATION

Easy and reliable KF titrations From 1 ppm to 100%

Evaluation of Capacitance in Motor Circuit Analysis Findings. Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN

Geavanceerde bepaling van water in poeders en vaste stoffen via geautomatiseerde Karl Fischer titratie. Peter van de Spreng 8 November 2011

Volumetric Analysis. Quantitative analysis answers the second question

Cl 2(g) + NaCl + H 2 O. light. 2Cl. Once formed, the chlorine radical can react with the heptane as shown below: + Cl

Final Review Graphs and Charts TWO Page 1 of 35

Experiment 12: Grignard Synthesis of Triphenylmethanol

Biology Basics Unit Review Guide

EE6701 HIGH VOLTAGE ENGINEERING UNIT II-DIELECTRIC BREAKDOWN PART A

From 1 ppm to 100% Karl Fischer water content determination

Solutions. LiCl (s) + H2O (l) LiCl (aq) 3/12/2013. Definitions. Aqueous Solution. Solutions. How Does a Solution Form? Solute Solvent solution

Understanding the Impacts of Moisture and Thermal Ageing on Transformer s Insulation by Dielectric Response and Molecular Weight Measurements

Flk = Acy + Cy z. Discover the perfect formula Fluka Reagents. Fluka TM Accuracy Consistency AUTHENTIC

Solids, liquids and gases

Experiment 6 Alcohols and Phenols

Conductivity Meter For Liquids LCM-8716 Manual

Chemistry Instrumental Analysis Lecture 23. Chem 4631

Experiment 2 - Using Physical Properties to Identify an Unknown Liquid

INTERNATIONAL STANDARD

Chapter 27: Gas Chromatography

CHEMISTRY HIGHER LEVEL

I. CHEM. E. SYMPOSIUM SERIES NO. 68

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

Basic Digestion Principles

London Examinations IGCSE

Sem /2007. Fisika Polimer Ariadne L. Juwono

Operating Instructions. METTLER TOLEDO DL37 KF Coulometer

PC Control / Touch Control

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Understanding Importance of Water Sorption Isotherm Shape, Hysteresis, and Models on Pharmaceutical Materials

Chemistry Gas Chromatography: Separation of Volatile Organics

WATER PROPERTIES. Supplemental Textbook Material Ch. 16, p

Introduction to Gas Chromatography

Thin Layer Chromatography

Boiling Point ( C) Boiling Point ( F)

Adsorption Processes. Ali Ahmadpour Chemical Eng. Dept. Ferdowsi University of Mashhad

TWO ENZYME CATALYSIS OVERVIEW OBJECTIVES INTRODUCTION

Punnett, Campbell and Vacala, Trevor - Integrating Microlab into General Chemistry I & II Experiments

Module 2. Measurement Systems. Version 2 EE IIT, Kharagpur 1

Karl Fischer Moisture Determination

The stoichiometry of burning hydrocarbon fuels

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

CHEMISTRY HIGHER LEVEL

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Determination of Nutrients. Determination of total phosphorus. Extraktion with aqua regia, reflux method. Introduction

Test Booklet. Subject: SC, Grade: HS CST High School Chemistry Part 2. Student name:

What is Science? Science is both a collection of knowledge and the process for building that knowledge.

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Rule 2. Rule 1. Rule 4. Rule 3. Rule 5. Rule 6. Rule 7. Rule 8

AP Chemistry: Designing an Effective Hand Warmer Student Guide INTRODUCTION

GENERAL INSTRUCTIONS GENERAL PREPARATION

Requirements to perform accurate dielectric material analysis

Comparing the Strength of Intermolecular Forces

Reproduction of Fleischmann and Pons experiments

"In Terms Of" 1. Explain, in terms of electron configuration, why arsenic and antimony are chemically similar.

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

Catalytic bead sensors are used primarily to detect

Experiment 1: Extraction and Thin Layer Chromatography

Definition: A hydrocarbon is an organic compound which consists entirely of hydrogen and carbon.

The Chemistry and Energy of Life

3.5 Alcohols H H C C. N Goalby chemrevise.org 1 H H. Bond angles in Alcohols. Boiling points. Different types of alcohols H 2 C CH 2 CH 2

What is the importance of redox reactions? Their importance lies in the fact that we can use the transfer of electrons between species to do useful

Lecture outline: Chapter 13

Structural characterization begins with a purity check!

Sampling. Information is helpful in implementing control measures for reducing pollutant concentration to acceptable levels

Experiment 3. Condensation Reactions of Ketones and Aldehydes: The Aldol Condensation Reaction.

STOICHIOMETRY AND THE CHEMICAL REACTION

CfE Higher Chemistry. Unit 3: Chemistry in Society. Chemical Analysis as part of quality control

4.2.1 Alcohols. N Goalby chemrevise.org 1 C O H H C. Reactions of alcohols. General formula alcohols C n H 2n+1 OH

CHEMICAL REACTIONS. Chapter11 OUTLINE GOALS Gas Fuels Solid Fuels

Whitepaper. How to Measure Conductivity over a Wide Range and at Ultra-low Levels

Transcription:

15 th IS 27-31 August 27 Ljubljana, Slovenia Reliability and Improvements of Water Titration by the Karl Fischer Technique M. Koch 1*, S. Tenbohlen 1, J. Blennow 2, I. oehlein 3 1 University of Stuttgart, IE, Pfaffenwaldring 47, 7569 Stuttgart, Germany 2 Chalmers University of Technology, S-412 96 Goeteborg, Sweden 3 Siemens AG, PTD, Transformers, Katzwanger Str. 15, 9461 Nuernberg, Germany *Email: maik.koch@ieh.uni-stuttgart.de Abstract: For the measurement of moisture in oilpaper-insulations the titration by Karl Fischer is considered as a reliable state of the art method. owever factors like moisture ingress during sampling and transportation, handling in the laboratory, chemical bonds of water and aging byproducts influence the result. The results of a round robin test on oil and paper samples revealed surprising differences in the water content measured by eight participating laboratories. In this investigation many of the discrepancies were explained. The influence of the heating temperature and the solvent for oil extraction for paper samples was systematically investigated. Best results obtained 16 C for paper and 18 C for pressboard samples and heptane for oil extraction. Besides three techniques for moisture in oil measurements were compared: volumetric titration with direct injection, coulometric titration with direct injection and coulometric titration with external oil heating. Coulometric titration with direct injection seems to deliver the most reliable results. Special emphasis is given to the comparison of Karl Fischer titration to results of moisture saturation measurements e.g. by capacitive probes or headspace systems. This illuminates the frequent discussions that question the validity of Karl Fischer titration in aged oils. Recommendations for reliable Karl Fischer titrations conclude this investigation. 1 INTRODUCTION Reliable assessment of the actual condition of high voltage power transformers allow for time- and costsaving maintenance actions. Moisture in cellulose and oil is an ageing indicator and accelerator, decreases the dielectric withstand strength and may generate gaseous bubbles in the liquid insulation. Aging gains importance since utilities keep transformers in service even if the estimated life cycle is exceeded. ence the number of wet transformers because of aging or even inadequate maintenance increases. 1.1 Difficulties with a State of the Art Method To evaluate the moisture content in the liquid and solid insulation the titration according to Karl Fischer is not only widely used, but also serves as a benchmark for other methods like dielectric response methods. Nevertheless it is affected by the following influences: (1) There is always a moisture ingress from atmosphere during sampling, transportation and sample preparation, for answers see section 5. (2) Cellulose binds water with chemical bonds of different strengths. It is unsure, if the thermal energy releases all the water. eating temperature and time strictly changes the released water (section 3.1). (3) Laboratories differently treat constraints, that are not covered by standards, such as the solvent for oil extraction (section 3.2). (4) Sometimes direct injection and heating method lead to different results for moisture in oil. This might be due to the influence of oil additives and ageing by products (section 4.1). Thus round robin tests revealed an unsatisfactory comparability of different laboratories. Additional discussions arose because of discrepancies between titration results and online moisture probes, e.g. capacitive sensors and headspace systems. This investigation will explain the difficulties and gives advice for practical problems. 1.2 Moisture Absorption in Oil Pure mineral transformer oil consists of saturated hydrocarbons such as paraffins and naphthenes. Because of their nonpolar molecule structure pure oil can dissolve only a very small quantity of water dispersed as water vapour according to enry s law. owever insulation oil in power transformers is polluted by remains from refinery, ageing byproducts and cellulosic particles. Thus the water solubility increases; water exists in the following states: - dispersed as water vapour in the oil bulk - bound to ageing byproducts by Van Der Vaals and hydrogen bonds - adsorbed by impurities e.g. cellulose fibres - small drops, when the saturation level is exceeded The moisture content W is usually related to oil weight (ppm as µg water / g oil) or as relative moisture saturation RS to the saturation value (%). 1.3 Moisture Absorption in Cellulose Pressboard and paper used as insulation materials consist to 85 % of cellulose, to 3-7 % of lignin and of 1 % hemicelluloses. In the following explanations cellulose should be the collective name for insulation materials such as pressboard, Transformerboard (Weidmann), Kraft paper (insulation paper) and thermally upgraded paper. Cellulose owns polar glucose

15 th IS 27-31 August 27 Ljubljana, Slovenia chains and therefore dissolves high quantities of water in the following states: - Strongly bound to O-groups of glucose chains by hydrogen bonds (at water contents below 1-2 %) - Weakly bound by Van Der Vaals bonds, water molecules may form multiple layers attracted to glucose chains (at medium water content) - old by capillary forces (at high water content) The ability to dissolve water is, depending on temperature, some thousand times higher compared to that of oil. Chemical adsorption O O O O O O O O O O O O C O Physical adsorption Fig. 1: Bonds of water molecules in cellulose O Capillar condensation 1.4 The Karl Fischer Titration Technique Karl Fischer titration is a method in analytical chemistry that determines trace amounts of water in a sample using volumetric or coulometric titration. The german chemist Karl Fischer (191-1958) introduced this titration method in 1935. Titration basically means to add a reagent of known concentration (titre) to a unknown substance until the concentrations are balanced. At volumetric titration the added volume is measured and the demanded value (here water content) is calculated by a stoichiometric equation. The sensitivity of volumetric titration is limited to some 1 µg water so that it is hardly applicable for dry insulation oils. At coulometric titration the reagent iodine is generated by a generator electrode and the need of its standardization is eliminated.. (1) is a simplified stoichiometric equation illustrating the reactions taking place in the titration vessel. The detection limit of coulometric titration reaches down to some µg of water. 2 2 O + SO 2 + I 2 2 SO 4 + 2 I (1) Equation (2) then calculates moisture relative to weight C W as the ratio of the measured water mass to the mass of dry and oil free paper m P multiplied with 1 %. Moisture ingress into the system as defined by the drift D (µg/min) and the humidity in an empty sample vessel (blind value m 2O,B in µg) must be substracted from the total moisture income m 2O. m 2O t D m 2O, B C W = 1% (2) m Electrolysis electrodes Anode chamber Rotor P Drying tube Cathode chamber Sample injection cap Sample injection port Detection electrode Fig. 2: Electrolysis cell for coulometric Karl Fischer titration The moisture of the material could be brought into the electrolysis cell (Fig. 2) by three methods: Firstly it is possible to inject the material directly into the reaction vessel, e.g. oil through a syringe. This method pollutes the reagent and side reactions of ageing products or inhibitors with the reagent are possible. Section 4.1 deals with this influence. Secondly the water from a cellulose sample can be extracted by immersion into a hydrophilic medium, e.g. methanol. Methanol and water will then be injected into the reaction vessel. Because of the slow extraction this methanol extraction is nowadays rarely applied. Thirdly the sample can be heated in an external oven and a gas stream with water vapour is lead into the reaction vessel. Advantageously the reaction vessel remains clean from pollutions and also from ageing byproducts, depending on their boiling point. A drawback of this method is the blank value of the gas stream and of the heating vessel. This decreases the sensitivity compared to the direct injection method, especially for oil. Fig. 3 illustrates a Karl Fischer titration in a pressboard sample using an external oven. Current water mass [µg/min] 1 9 8 7 6 5 4 3 2 1 Current water mass Accumulated water mass 1 2 3 4 5 6 Time [min] 2 18 16 14 12 1 8 6 4 2 Fig. 3: Currently measured and accumulated water mass at a typical water titration in pressboard with external heating Accumulated water mass [µg]

15 th IS 27-31 August 27 Ljubljana, Slovenia 1.5 Comparability to Other Moisture Sensing Methods Some users compared the moisture result in oil from Karl Fischer titration to the moisture in oil in ppm obtained from capacitive probes or photo-acoustic DGA. Capacitive probes basically indicate moisture relative to saturation. They consist of two electrodes with a dielectric made by a hydroscopic polymer. Water molecules penetrate into the polymer depending on the relative saturation of the ambient material driven by equilibrium processes [1]. Some operators stated significant differences comparing results from Karl Fischer titration and capacitive probes or other instruments based on moisture equilibrium, e.g. [2]. They concluded, that Karl Fischer titration is not valid for aged oils for two reasons: Firstly, a deviation between capacitive probes and Karl Fischer titration appears only for oils with an observable acidity. Secondly, for aged oils the breakdown voltage was good, although Karl Fischer titration measured a high moisture content. Capacitive probes however indicated a low moisture content. Contrary to this the authors of this publication argue: Firstly, it is principally incorrect to compare the ppm-result of capacitive probes to the ppm-result of Karl Fischer titration. Karl Fischer titration measures water mass by a stochiometric equation while capacitive probes measure moisture equilibrium and therefore the relative moisture saturation. Moisture by weight in ppm is delivered only by the mathematical equation using two constants A and B [3]. These constants depend on water saturation level of the oil (e.g. aging state, pollutions, kind of oil). Therefore to obtain reliable ppm-values the sensor must be calibrated for each oil, otherwise the comparison will fail. Because of the different measurement techniques there is no direct comparability given to KFT. This explanation applies for all techniques based on moisture equilibrium such as e.g. head space methods used in photo-acoustic DGA. Breakdown Voltage [kv] 8 7 6 5 4 3 2 1 2 4 6 8 1 12 14 Moisture Saturation in Oil [%] Fig. 4: Breakdown Voltage and Relative Moisture Content in Mineral Oil Secondly, the influence of moisture on the breakdown voltage of oil depends directly on the moisture content relative to saturation [4]. There is only an indirect sensitivity to moisture by weight in ppm. An example: For new oil a moisture content of 4 ppm of moisture by weight at 4 C means a RS of 33 % [1]. Therefore the breakdown value will be 58 kv (Fig. 4). For an aged oil the same moisture content follows in a RS of 16 %, the breakdown voltage will be unexpectedly high with 69 kv. 2 ROUND ROBIN TEST 2.1 Participating Laboratories Eight laboratories from four European countries took part in a round robin test. Tab. 1 describes the equipment used in the test. Tab. 1: Titration techniques used in the round robin test Lab Instrument for Paper samples eating temp. Instrument for Oil samples A Coulometric, 16 C Coulometric, direct injection B Coulometric, 2 C Coulometric, direct injection C Coulometric, 135 C Coulometric, heating with oven D Coulometric, 135 C E Volumetric - Volumetric F Coulometric, 14 C Coulometric, heating with oven at 8 C G Coulometric, Coulometric, direct injection 2.2 The Samples Three oil and paper samples filled in flasks made of PE were the measurement objects. Two of the samples consisted of new Kraft paper and new insulation oil Nynas Nytro 3 having a relative moisture saturation in oil and paper of 2,7 % resp. 4,7 % measured at 8 C. The third sample was a service-aged paper from 1954 in service-aged Shell K 6 SX having a relative moisture saturation of 33 % at 27 C. The oils neutralization number was very high with,49 mg KO / g Oil. 2.3 Measurement Results for Water in Paper The laboratories measured the water content in paper relative to weight and the water content in oil relative to weight according to their standard procedure. The results as depicted in Fig. 5 show a reasonable conformance compared to previous tests. One systematic influence is obvious: The heating temperature of paper in the oven increases the released mass of water. This is due to chemical bonds of different strengths which keep the water molecules in the paper. Beside this the differences could be explained by stochastic influences only. For the low water content of sample A the comparability is worst and hardly acceptable.

15 th IS 27-31 August 27 Ljubljana, Slovenia Moisture in paper [%] 5, 4, 3, 2,43 2,25 2,25 1,97 2, 1,79 1,7 1,78 1,64 1,65 1,45 1,36 1,24 1,2 1,8 1,, A B C D E F G 3,64 3,4 3,38 3,27 3,2 2,97 Sample A Sample B Sample C 2,19 Fig. 5: Moisture in paper in % relative to weight as measured by the laboratories 2.4 Measurement Results for Water in Oil Water in oil [ppm] 6 5 4 3 2 11,2 12,1 9,5 1 6,7 4,7 4,8 3,5 A B C D E F G 19,8 16,2 15,2 12,2 8,9 7,5 5,8 32,8 54,8 44,3 39,8 Sample A Sample B Sample C 34,5 ppm 35,3 Fig. 6: Moisture in oil in ppm relative to weight as measured by the laboratories 39,7 The measurement results of Fig. 6 provide a reasonable conformance only for the wet sample C. For the rather dry samples A and B only a trend is recognizable. Systematic differences are obvious. It has to be mentioned, that at dry oils the results also scatter within one single laboratory, a standard deviation of 2 % is not unusual. The following chapters of this article will investigate the influences and thus try to explain the discrepancies. 3 IMPROVED MEASUREMENTS IN PAPER 3.1 Influence of eating Temperature eating with an external oven is widely used for water in cellulose measurements. Cellulose binds water with chemical bonds of different strengths (Fig. 1). Water measurements should reveal all water from the material, however it is unsure, if the thermal energy releases all the water. eating temperature and time strictly changes the amount of released water molecules. According to IEC 6814 the temperature should be 13-14 C. The authors of [5] found, that at pressboard samples only a temperature of 18 C leads to results comparable to the methanol extraction method (section 1.4). On the other hand the upper limit for the heating temperature is given by pyrolysis or oxidation of cellulose with subsequent water production in the heating chamber. This occurs for paper above 17 C, for pressboard above 2 C. Several measurements at various increasing temperatures determine the heating temperature for the material to be measured. ere the optimal heating temperature was found for insulation paper to 16 C and for pressboard to 18 C. These temperatures not only detect more water, rather the measurement is faster (e.g. 5 min at 17 C instead of 12 min at 12 C) and the single measurements are less scattered. Fig. 7 illustrates the influence of heating temperature on water content and scattering. 3.2 Solvent for Oil Extraction After titration it is necessary to extract oil from paper in order to obtain the true dry weight of the paper sample for application in equation (2). Unfortunately the standard IEC 6814 does here only state a appropriate chlorine-free solvent. Some laboratories do not separate oil from paper and thus obtain a too high paper mass. Others use methanol as oil solvent. Indeed methanol cannot dissolve oil, a dispersion arises instead of a solution, a lot of oil remains in the paper. For this reason heptane was investigated in comparison to methanol. Its nonpolar molecule structure enables heptane to extract the likewise nonpolar mineral oil from cellulose. Other paraffin mixtures with boiling points of 7-9 C are applicable too (e.g hexane). Water in paper [%] 5 4 3 2 1 eptane Methanol 1 11 12 13 14 15 16 17 18 Temperature [ C] Fig. 7: Detected amounts of water in insulation paper for different heating temperatures and solvents for oil

15 th IS 27-31 August 27 Ljubljana, Slovenia Fig. 7 proves the qualification of heptane in comparison to methanol. eptane releases more oil from paper, the dry weight of paper decreases, thus according to equation (2) the obtained water content increases. ere a titration system called Aqua 4. by EC Germany with head space module Coulomat Oven AG from Riedel de aen as reagent was used. 4 IMPROVED MEASUREMENTS IN MINERAL OIL 4.1 Influence of Aging Byproducts Aging byproducts from oil degradation and inhibitors may influence the Karl Fischer reaction of oil samples with direct injection. Aging of oil causes alcohols, aldehydes, ketones, acids and sludge. It is assumed, that aldehydes and ketones react with methanol of the reagent to acetales and ketales with water as a byproduct. To prove this suspicion, a coulometric titration cell with direct injection titrated various oil samples (new, aged, inhibited). Two different reagents from Riedel de aen were used; ydranal Coulomat AG with methanol and Coulomat AK without, that especially suites for titrations in aldehydes and ketones preventing side reactions. Water in oil [ppm] 3 25 2 15 1 5 1 3 5 7 9 11 13 15 17 Sample number Coulomat AG Coulomat AK 19 21 23 25 Average 12 1 Fig. 8: Titration results comparing the reagents Coulomat AG and AK at various oil samples Fig. 8 shows the reagent Coulomat AG in comparison to Coulomat AK, which is not sensitive to ketones. The results scatter, but the reagent AG systematically measures 1 % more water compared to AK, which might be explained by side reactions with ketones. Still one has to consider that 1 % are a minor deviation compared to that in the round robin test in Fig. 6. It is not favorable to always use reagents that are insensitive to ketones and aldehydes, since their water absorption capacity is smaller. Currently Karl Fischer reagents based on ethanol instead of methanol are introduced to the market, which promise to be nontoxic, to better dissolve mineral oil and have no side reactions with alcohols [6]. These reagents are not involved in this test. AG AK 8 6 4 2 Average [%] 4.2 Direct Injection versus eating Method Three variations of the Karl Fischer technique for oil titration were compared: - volumetric titration using a Schott Titroline Alpha, with reagent Coulomat Solvent Oil - coulometric titration with direct injection using an EC Aqua 4. and Coulomat Oil by Riedel de aen as reagent - coulometric titration with heating chamber for oils using an EC Aqua 4. and Coulomat Oven AG by Riedel de aen as reagent, heating temperature 8 C, oil volume 1 ml Of course all the techniques should come to the same moisture content in oil. One remark about water in oil measurements by heating in an external oven: Transformer oils usually have very low water contents of sometimes less than 5 µg/g oil. Unfortunately for the heating method the water mass should exceed 5 µg to be distinguishable from the drift and the blank value. Therefore an oil volume of at least 1 ml should be heated. It is not sufficient to use the vials from paper measurements since their useable volume is 2,5 ml only, a special heating chamber for oil is necessary. Water in oil [ppm] 14 12 1 8 6 4 2 Nynas Nitro 3 Shell Diala D Oil 25a aged Aged Shell K6SX Oil A Shell Diala G Oil B aged Volumetric Coulometric - direct Coulometric - heating Oil C aged Petro 5GX Shell GX Oil Bushing Fig. 9: Moisture in various oils for volumetric titration, coulometric titration with direct injection and coulometric titration with external heating Fig. 9 depicts the results of the comparative measurements at various new and aged oil samples. For new oils all the three methods came to comparable results, although also here a deviation of 2 % appears. Volumetric titration indicates the highest water contents, followed by direct coulometric titration. Coulometric titration with an external heating chamber comes to the lowest water contents. In aged oils the situation became even worse. Also here volumetric titration measures the highest water contents. Unfortunately the coulometric titration with external heating in some oils was not able to measure their water content. The drift did not decrease to the

15 th IS 27-31 August 27 Ljubljana, Slovenia original value but remained at 2-3 µg/min, which possibly indicates a side reaction. This leads to water contents of some 1 ppm as in the round robin test in Fig. 6. As a conclusion, the external heating method cannot be recommended for aged oils, while aged materials are the common case in transformer diagnostics. 5 RECOMMENDATIONS FOR RELIABLE TITRATIONS 5.1 Onsite Sampling The sampling procedure determines the reliability of the moisture result, it should be performed with care. Oil should be sampled from different levels in the transformer; if possible top, middle and bottom. Samples should not be taken at high air humidity (rain, fog). When taking the samples, a few litres of oil should be drained out for preventing sludge and standing oil to be sampled. The bottle should be dry and technically clean that moisture inside the bottle cannot contaminate the oil. For the same reason the bottle should be completely filled, leaving no space for air at the top. Since transformer oil is considered to be harmful to the environment, precautions must be taken to avoid contamination of the soil around the transformer. Paper should be sampled as soon as possible after opening the transformer. The outer layers of the conductor insulation may be moistened by air, thus it should be removed. Remove the edge of paper and pressboard samples too for the same reason. The transformers insulation oil is useful to store paper and pressboard samples during transportation to the laboratory. Besides the cellulose samples keep the oil humidity at a low level close to the original value. When storing oil and paper together, the temperature of oil titration must be identical to that of oil sampling. Notice the oil temperature during sampling directly in the oil, don t use the transformers thermometer. The transportation time should be short, the time between sampling and measurement ought to be below one week, depending on the tightness of the vessel. Check for the measurement date of the laboratory. 5.2 Quality Assurance in the Laboratory (1) Before titration the instrument should be conditioned resulting in a stable drift below 12 µg/min. During this the gas circulation and the oven if available should be active. At external heating three single measurements of the blind value will give a reliable average to compensate for this factor. (2) Water standards (liquid for direct injection, solid for external heating) should periodically check the reactivity of the reagent. A consumed reagent cannot be indicated by a high or unstable drift value only. (3) The heating temperature for paper should be 16 C, for pressboard 18 C. Thus the reproducibility increases, the measurement time decreases and the sample will not be oxidized. (4) To separate oil from cellulose an oil-solving medium such as heptane suits better than methanol. (5) For titration of oil the coulometric titration with direct injection seems to be the most reliable method. External heating in an oil chamber cannot be recommended because of possible side reactions in aged oils. Volumetric titration owns a lower sensitivity compared to coulometric titration. 6 SUMMARY AND OUTLOOK The titration according to Karl Fischer serves as a state of the art method for moisture determination in liquid and solid samples. Nevertheless it is subject to several influences, which lead to a bad comparability of results from different laboratories, especial for moisture determination in oils. This was revealed by two round robin tests. Four influences were investigated: heating temperature of paper/pressboard, solvent for oil separation, aging byproducts in oil, external heating of oil. This lead to a guide for reliable titrations, see section 5. Future research might try to replace methanol in the reagent since it is toxic and sensitive to aging byproducts. The reliability of the external heating method for oils should be improved, especially in respect of aged oils. A comparison to other methods like gas chromatography might be useful, but will raise additional questions. 7 REFERENCES [1] M. Koch: Improved Determination of Moisture in Oil-Paper- Insulations by Specialised Moisture Equilibrium Charts Proceedings of the XIVth International Symposium on igh Voltage Engineering, p. 58, Beijing, China, 25 [2] J. Altmann, Bukvis: The Oil-Moisture Diagnostic Problem of Aged Transformers, ARS2. www.transformerconsulting.com [3] PPM Calculations for Transformer Oils User s Guide MP 228, M11-A, Vaisala Oyj, elsinki, Finland 2 [4] Fonfana, I., Wasserberg, V., Borsi,., and Gockenbach, E.: Challenge of Mixed Insulating Liquids for Use in igh-voltage Transformers, Part 1: Investigations of Mixed Liquids. IEEE Electrical Insulation Magazine 18 (22), No. 3, pp. 18 25. [5] O. Kleboth-Lugova, B. Buerschaper, T. Leibfried: Feuchtebestimmung in Isoliermedien - ein Erfahrungsbericht ETG Fachtagung Diagnostik, Koeln 24 [6] M. Jeitzinger,. offman: Non-Toxic ydranal Karl Fischer Reagents Based on Ethanol, Analytix, Advances in Analytical Chemistry, 4/26, Sigma Aldrich Chemie Gmb, Buchs, Switzerland