S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

Similar documents
S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

Operating Instructions for Ammonium ISE Specifications

READING A. INTRODUCTION CHE425L POTENTIOMETRY WITH K + ION-SELECTIVE ELECTRODE. Skoog, Holler and Crouch: Chapter 23 and Appendix 3.

GENERAL INSTRUCTIONS GENERAL PREPARATION

Chapter 3 Electrochemical methods of Analysis-Potentiometry

Instrumental Chemical Analysis. Dr. Abdul Muttaleb Jaber Professor Faculty of Pharmacy Philadelphia University Fall 2012/2013

Chem 321 Lecture 17 - Potentiometry 10/24/13

COLE-PARMER INDUSTRIAL CALCIUM ION ELECTRODE INSTRUCTION MANUAL

Ch. 14. ELECTRODES AND POTENTIOMETRY

CHAPTER 14: ELECTRODES AND POTENTIOMETRY

Unit 2 Electrochemical methods of Analysis

F- Cl- Br- I- CN- S2- NO3-

COLE-PARMER INDUSTRIAL POTASSIUM ION ELECTRODE INSTRUCTION MANUAL

Na+ K+ Ag+ Ca2+ NH + 4. F- Cl- Br- I- CN- S2- NO3-

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015

Fig. Electrochemical Cell/ Potentiometric Titration

GENERAL INSTRUCTIONS GENERAL PREPARATION

COLE-PARMER LABORATORY CALCIUM ION ELECTRODE INSTRUCTION MANUAL

General terms relevant to ion-selective electrodes

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste

NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

Chemistry Instrumental Analysis Lecture 22. Chem 4631

INSTRUCTION MANUAL. Type: ORP500 C, ORP500 CD, ORP222 CD, ORP223 CD EN Introduction Helpful Operating Tips. 2

Ion Selective Electrode Probe

Chapter 13 POTENTIOMETRIC ELECTRODES AND POTENTIOMETRY

Buffer Preparation. Learning Objectives:

COLE-PARMER LABORATORY AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

Thermo Scientific Orion Fluoride Ion Selective Electrodes The standard in fluoride ion analysis EPA compliant

COLE-PARMER INDUSTRIAL AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER LABORATORY NITRATE ION ELECTRODE INSTRUCTION MANUAL

PRACTICAL 3 ph AND BUFFERS

Simplified Analysis for Soil Samples with Compact Water Quality Meter <LAQUAtwin>

The Cole-Parmer Ammonium Ion Electrode is used to quickly, simply, accurately, and economically measure ammonium ions in aqueous solutions.

Analysis of cations and anions by Ion- Selective Electrodes (ISEs)

COLE-PARMER REPLACEABLE MEMBRANE CALCIUM ION ELECTRODES INSTRUCTION MANUAL

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

Practical 1P3 Electrode Potentials

METHODS FOR DETERMINATIONS OF ELECTROLYTES AND BLOOD GASES

perfection Guidebook perfection Combination Fluoride Electrode Successful Ion Measurement

Electrochemistry. Redox reactions. Half Reactions. Nernst Equation Ion selective electrodes

A) QUICK GUIDE TO BASIC OPERATION

Supporting Information for: Potentiometric Sensing Array for Monitoring Aquatic Systems

Electro Analytical Methods

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

ph Probe Spear Tip Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth

The Cole-Parmer Nitrate Ion Electrodes are used to quickly, simply, accurately, and economically measure nitrate in aqueous solutions.

1) A ph/mv meter or an ion meter, either line operated or portable.

Ion Selective Electrodes

Rapid RH Portable ph Meter. User's Manual

NH 3 -selective electrodes

COLE-PARMER LABORATORY CUPRIC ION ELECTRODE INSTRUCTION MANUAL

ph Probe Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth 1 99 C

POTASSIUM ION SELECTIVE ELECTRODE

Electrochemical studies on Dowex-50 membrane using sodium chloride and urea solutions having variable composition

COLE-PARMER INDUSTRIAL NITRATE ION ELECTRODE INSTRUCTION MANUAL

ph Probe ReallyEasyData com

GENERAL INSTRUCTIONS GENERAL PREPARATION

Chapter 17: Additional Aspects of Aqueous equilibria. Common-ion effect

Ion-selective Measurements

ProPac WCX-10 Columns

COLE-PARMER INDUSTRIAL NITRATE ION ELECTRODE INSTRUCTION MANUAL

A SILVER/SILVER SULPHIDE SELECTIVE ELECTRODE PREPARED BY MEANS OF CHEMICAL TREATMENT OF SILVER WIRE

User Guide. High Performance Ammonia Ion Selective Electrode

We CAN have molecular solutions (ex. sugar in water) but we will be only working with ionic solutions for this unit.

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

perfection Guidebook perfection Combination Iodide Electrode Successful Ion Measurement

Chapter 14: Electrodes and Potentiometry

Guide to ph Analysis.

Chapter 18 Electrochemistry. Electrochemical Cells

2. Which of the following statements best describes the movement of electrons in an electrochemical cell?

Determination of fluorides in aqueous samples using membrane, ion selective electrode (ISE)

Chemistry 325 Instrumental Methods of Analysis March 13, Final Exam. Name

Electrochemistry. Part One: Introduction to Electrolysis and the Electrolysis of Molten Salts

The Oakton Cadmium Ion Electrodes are used to quickly, simply, accurately, and economically measure cadmium ions in aqueous solutions.

Ion-selective Measurement (ISE)

Membrane Electrodes. Several types

Ion Selective Sensors and Electrodes Technologies for Industrially, Environmentally and Biologically Significant Ion Measurements

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

Nanotechnology Sensors

Use a pipet bulb when pipeting cyanide solutions, as these solutions are highly toxic.

COLE-PARMER LABORATORY CYANIDE ION ELECTRODE INSTRUCTION MANUAL

Unit 4: Chemical Changes (Higher Content)

Use of Ion Selective Probes

ph electrodes: what users should know

Chemistry MultiMeasure Sensor PS-2170

MEASUREMENT OF ph: INTRODUCTION TO BUFFER AND BASICS OF ph Meter

CALCIUM SELECTIVE ELECTRODE

ELECTROCHEMISTRY. these are systems involving oxidation or reduction there are several types METALS IN CONTACT WITH SOLUTIONS OF THEIR IONS

EXPERIMENT 16 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

Direct Ion Speciation Analysis with Ion-selective Membranes Operated in a Sequential Potentiometric/Time Resolved Chronopotentiometric Sensing Mode

R S. Publication, Page 638

Chapter 29. Simple chemical cells

ION SELECTIVE ELECTRODES FOR SOLUBLE SALT MEASUREMENTS ON ICY WORLDS

If you like us, please share us on social media. The latest UCD Hyperlibrary newsletter is now complete, check it out.

Chapter 12 Tex-617, Determining Chloride in Concrete

Transcription:

150mV 300mV Mono/Reference Combination S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) 1376 340 456 Fax: +44 (0) 1376 340 453 Email: sentekuk@btconnect.com

Operating Instructions Calcium Ion Selective Electrode This Document includes operating instructions for two types of Ion Selective Electrode. A single sensing Half Cell Calcium Electrode which requires a separate Reference Electrode, and a Combination Calcium Electrode which has the Reference built into the outer shaft. For extremely low level work the Half Cell plus Reference Electrode should be used. For general applications the Combination is more convenient. Depending on the type of ISE chosen you will need to disregard some information for instance if you have the Combination Electrode then disregard any comments about reference electrodes. A quick guide is included with a more involved section following. SENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: + 44 (0) 1376 340 456 Fax: +44 (0) 1376 340 453 Email: sentekuk@btconnect.com

Operating Instructions for Calcium Ion Selective Electrode 1. Introduction 1.1 Construction The electrode consists of an inert fluorocarbon body with a solid state PVC membrane unit. The sensitive membrane consists of liquid ion exchange material immobilised in a poly-(vinyl chloride) matrix. Connection to a millivoltmeter is via coaxial cable and BNC plug. As an alternative, other plugs may be specified. 1.2 Operating Principles The electrical potential of an ion selective electrode is a function of the activity of certain ions in an aqueous solution. This potential can only be measured against a reference electrode, such as a saturated calomel electrode (SCE), placed in the same solution. Measurements are made with a high impedance millivoltmeter or expanded scale ph meter. A meter with digital display is obviously more accurate and most convenient. The calcium electrode cannot be used in non aqueous solvents but the presence of up to 40% organic solvents in an aqueous solution can be tolerated. For further discussion on the principals of ISE measurements, the user is referred to the Technical Bulletin which is available on demand. 1.3 Sensitivity The electrode will respond to uncomplexed calcium ion activity over the range10 o - 5x10-6 M. The linear detection limit is around 10-5 M but careful calibration allows the electrode to be used down to 5 x 10-6 M. Curvature of the response is observed at lower concentrations because the solubility of the liquid ion exchanger, leached from the membrane, contributes a small but significant amount of calcium to the solution being measured. Figure 1 shows a typical calibration plot of the electrode. Values for the slope of the plot should lie in the range 24-29mV/decade. If the total ionic strength of all solutions is maintained constant by the addition of a concentrated (ca. 10-1 M) inert electrolyte, such as potassium nitrate or sodium fluoride, the electrode can be calibrated directly in concentration units.

The activity coefficient of calcium ion depends upon the ionic strength of the solution. The following table can be used to calculate the approximate activity coefficients at various ionic strengths. Ionic Strength 0.001 0.005 0.01 0.05 0.1 0.2 Activity coeff. 0.905 0.809 0.749 0.57 0.485 0.405 The ionic strength of the solution to be tested can be calculated from the formula: N Ionic Strength = ½ CiZi 2 i=1 where Ci is the concentration of species i and Zi is its charge, and all species, cations and anions, must be taken into account. Once the ionic strength is calculated and the activity coefficient found from Table 1 then the activity of the ion of interest is found from: 1.4 Stability Activity (Ai) = Concentration (Ci) x Activity Coefficient (f) The long-term drift in the E0 value of the calcium electrode is usually in the region of 1-2mV/day.

1.5 Selectivity The calcium electrode is free from any really major interference with the exception of zinc ions. Relative selectivity ratios for several interfering ions are given in the table below: Interfering Ion Selectivity Ratio Mg 2+ 2.5 x 10-4 Ba 2+ 3 x 10-3 Pb 2+ 0.1 Zn 2+ 1.0 Fe 2+ 0.8 Na + 1.45 x 10-4 K + less than 10-6 The selectivity ratios vary with interferent activity and according to method of measurement. These figures should be used as a guide only. The electrode should be used in the ph range 4-9. 1.6 Response Time The electrode will respond to a step change in the calcium ion activity in solution in less than 10 seconds. When however, the electrode is removed from one solution and placed in another of different calcium concentration, it may take up to 30 seconds to achieve a new equilibrium. The presence of some interfering ions, especially Mg 2+, Zn 2+ and Sr 2+ can cause considerable increase in the response time. After exposure to strong concentrations of such ions, the electrode should be reconditioned in 10-2 M calcium solution or about an hour. 2. Operating and Handling 2.1 Initial Setting Up On receipt of the electrode remove it from its packaging and inspect for damage, particularly to the delicate membrane, which forms the sensing end of the electrode. The electrode is now ready for use. 2.2 Making a Measurement The electrode should first be calibrated as follows. Clamp the electrode vertical in a position such that the membrane is immersed in a beaker of 10-1 M calcium solution placed on a magnetic stirrer. Ensure that the liquid level does not come above the membrane unit/electrode body junction. Clamp a reference electrode (a single junction Ag/AgCl or S.C.E. is quite adequate) so that its end is immersed in the same solution and connect both electrodes to a ph or millivoltmeter. Record the potential when it becomes steady. Change the test solution sequentially for 10-2 M, 10-3 M and 10-4 M calcium solutions and plot the calibration curve, washing and drying the electrode between solutions.

Unknown solutions can now be measured directly. For further details of methods of measurement, the user is referred to Technical Bulletin E1 available from the electrode supplier. 2.3 Storage If the electrode is to be sued within a week or so, it can be merely removed from the test solution, washed and dried and be clamped in a vertical position in the air. There is in principal no limit to the storage time, but gradual oxidation of the membrane will, however, cause it to harden and lose its response. Shelf life, in its dry state, is better than twelve months. 2.4 Flow Through Configuration A conversion kit is available to enable continuous flow-through measurements to be made. The reference contact can be made at any point in the solution stream joined to the flow cell by a continuous stream of liquid usually downstream of the electrode. The flexible nature of the membrane causes the pump pulses to produce rather more 'noise' on the electrode signal than normally found (+0.8mV as opposed to +0.2mV). This can be mitigated by either damping the recorder input signal or using a pulseless pump. 3. Applications and Bibliography The calcium electrode has been used extensively for the measurement of inorganic calcium in aqueous systems. Applications such as titration's, complexometric studies and activity coefficient determinations are now commonplace and references can be found in almost any journal. The increasingly widespread use of calcium electrode in physiological and biological fluids has been a result of the many research papers published in this field. Continuous flow measurements of ionised calcium in blood and serum have provided a new simple and rapid method for the routine determination of free¼bound calcium ratios, which are of significant physiological importance. The following is a selected list of some of the more interesting applications of the calcium electrode. Calcium in Tap Water G. J. Moody et al., Analyst, 95 (1970) 910 Calcium in Sea Water D. Jager and K. Aren, Anal. Chim. Acta, 57 (1971) 185

M. E. Thompson, Science, 153 (1966) 867 M. E. Thompson and J. W. Ross, Science, 154 (1966) 1643 Calcium in Detergents R. W. Cummins, Detergent Age, March 1698, P.22 Calcium in Soil Extracts S. A. El-Swaify and M. W. Gazdar, Soil Sci. Soc. Amer. Proc, 33 1968 665 J. G. A. Fiskell and H. L. Breland, Soil Crop Sci. Soc. Fla. Proc., 29 (1970) 63 E. A. Woolson et al., Soil Sci., 109 (1970) 279 K. L. Cheng et al., Microchem J., 18 (1973) 256 Calcium in Milk P. J. Muldoon and B. J. Liska, J. Dairy Sci., 52 (1969) 460 R. Kramer and H. Lagoni, Naturwiss., 56 (1969) 36 Calcium in Serum J. Ruzicka and J. C. Tjell, Anal. Chim. Acta., 47 (1969) 475 D. E. Arnold et al., Amer. J. Clin. Path., 49 (1968) 627 D. E. Arnold et al., Amer. J. Clin. Path., 49 (1968) 52 D. S. Bernstein, Endocrinol., 85 (1969) 589 E. W. Moore, J. Clin. Invest., 49 (1970) 318 I. C. Radale et al., Clin. Chem., 17 (1971) 1002 W. G. Robertson and M. Peacock, Clin. Chim. Acta., 20 (1968) 315