Towards Proton Computed Tomography

Similar documents
Initial Studies in Proton Computed Tomography

Loma Linda University Medical Center, Loma Linda, CA 92354

Beam Test for Proton Computed Tomography PCT

Radiobiology at SCIPP

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 54, NO. 1, FEBRUARY

PROTON radiation therapy is one of the most precise forms

Prototype Tracking Studies for Proton CT

a) Dipartimento di Fisiopatologia Clinica, Università degli Studi di Firenze, v.le Morgagni 85, I-

Reconstruction for Proton Computed Tomography: A Monte Carlo Study

UNIVERSITY of CALIFORNIA SANTA CRUZ

Physics of Novel Radiation Modalities Particles and Isotopes. Todd Pawlicki, Ph.D. UC San Diego

The Most Likely Path of an Energetic Charged Particle Through a Uniform Medium

First Results and Realization Status of a Proton Computed Radiography Device

Proton radiography with a range telescope and its use in proton therapy

Physics of particles. H. Paganetti PhD Massachusetts General Hospital & Harvard Medical School

Fast and compact proton radiography imaging system for proton radiotherapy

Density resolution of proton computed tomography

UNIVERSITY of CALIFORNIA SANTA CRUZ

Tracking Study of 200 MeV Protons within a PMMA. Phantom

A Brief Introduction to Medical Imaging. Outline

Fitting the Bragg peak for accurate proton range determination

III. Energy Deposition in the Detector and Spectrum Formation

Compton Camera. Compton Camera

Synchrotron Radiation a Tool for Precise Beam Energy Measurements at the ILC

Monte Carlo study of the potential reduction in out-of-field dose using a patient-specific aperture in pencil beam scanning proton therapy

8/3/2016. Chia-Ho, Hua St. Jude Children's Research Hospital. Kevin Teo The Hospital of the University of Pennsylvania

Outline. Physics of Charge Particle Motion. Physics of Charge Particle Motion 7/31/2014. Proton Therapy I: Basic Proton Therapy

The interaction of radiation with matter

Development of High-Z Semiconductor Detectors and Their Applications to X-ray/gamma-ray Astronomy

CRaTER Pre-Ship Review (PSR) Instrument Calibration Science Requirements Compliance

Prompt gamma measurements for the verification of dose deposition in proton therapy. Contents. Two Proton Beam Facilities for Therapy and Research

Physics of Particle Beams. Hsiao-Ming Lu, Ph.D., Jay Flanz, Ph.D., Harald Paganetti, Ph.D. Massachusetts General Hospital Harvard Medical School

Controlled Si-Drift Detectors

Status Report: Multi-Channel TCT

9. Application to Proton Therapy

The Hermes Recoil Silicon Detector

Basic Radiation Physics of Protons

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Emphasis on what happens to emitted particle (if no nuclear reaction and MEDIUM (i.e., atomic effects)

THE mono-energetic hadron beam such as heavy-ions or

LET! (de / dx) 1 Gy= 1 J/kG 1Gy=100 rad. m(kg) dose rate

Status Report: Charge Cloud Explosion

Particle Detectors. Summer Student Lectures 2010 Werner Riegler, CERN, History of Instrumentation History of Particle Physics

A Monte Carlo Study of the Relationship between the Time. Structures of Prompt Gammas and in vivo Radiation Dose in.

How we wanted to revolutionize X-ray radiography, and how we then "accidentally" discovered single-photon CMOS imaging

Quantitative Assessment of Scattering Contributions in MeV-Industrial X-ray Computed Tomography

Title: Proton radiography and tomography with application to proton therapy. Short title: Proton radiography and tomography

pp physics, RWTH, WS 2003/04, T.Hebbeker

The LHC Experiments. TASI Lecture 2 John Conway

APPLIED RADIATION PHYSICS

Development of a High Precision Axial 3-D PET for Brain Imaging

CRaTER Pre-Environmental Review (I-PER) Science Requirements Update

Queen s University PHYS 352

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

CT-PET calibration : physical principles and operating procedures F.Bonutti. Faustino Bonutti Ph.D. Medical Physics, Udine University Hospital.

Il picco di Bragg. G. Battistoni INFN Milano. 08/06/2015 G. Battistoni

2. Passage of Radiation Through Matter

X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND TRANSPORT. University of California Davis. Dorthe Wildenschild & Annette Mortensen

Chapter V: Cavity theories

Proposal to convert TLS Booster for hadron accelerator

Hadron Therapy Medical Applications

ATHENA Radia+on Environment Models and X-Ray Background Effects Simulators

Gamma-Ray Polarimetry in the Pair Production Regime

CHARACTERISTICS OF DEGRADED ELECTRON BEAMS PRODUCED BY NOVAC7 IORT ACCELERATOR

Development of beam delivery systems for proton (ion) therapy

User Documents and Examples II

AN ALGORITHM FOR TWO DIMINUTIONS DENSITY RECONSTRUCTION IN PROTON COMPUTED TOMOGRAPHY (PCT) A Thesis. Presented to the. Faculty of

Particle Beam Technology and Delivery

Imaging principle and experiment results of an 11 MeV low-energy proton radiography system

Detector R&D in KAPAC

User Documentation and Examples (II) in GEANT p01

Nuclear AstroPhysics at ELI-NP: preliminary experiments with ELISSA detector. Giovanni Luca Guardo

III. Proton-therapytherapy. Rome SB - 2/5 1

CRaTER Science Requirements

Characterization of heavy charged particle fields using fluorescent nuclear track detectors

Semiconductor X-Ray Detectors. Tobias Eggert Ketek GmbH

LECTURE 4 PRINCIPLE OF IMAGE FORMATION KAMARUL AMIN BIN ABDULLAH

FLUKA simulations of selected topics regarding proton pencil beam scanning

Interactions of Particulate Radiation with Matter. Purpose. Importance of particulate interactions

Dario Barberis Evaluation of GEANT4 electromagnetic physics in ATLAS

ABSOLUTE AIR-KERMA MEASUREMENT IN A SYNCHROTRON LIGHT BEAM BY IONIZATION FREE-AIR CHAMBER

Validity of the Analysis of Radiochromic Film Using Matlab Code

EEE4101F / EEE4103F Radiation Interactions & Detection

Towards efficient and accurate particle transport simulation in medical applications

Simulation study of scintillatorbased

Transition Radiation Detector for GlueX

CHIPP Plenary Meeting University of Geneva, June 12, 2008 W. Lustermann on behalf of the AX PET Collaboration

Joe Parker for the Cosmic Ray γ Group Kyoto University

Interaction of Particles and Matter

Progress in using prompt gammas for ion range monitoring during hadrontherapy

Technical University of Denmark

GEANT4 simulation of the testbeam set-up for the ALFA detector

CMOS Active Pixel Sensors as energy-range detectors for proton Computed Tomography

PHITS calculation of the radiation field in HIMAC BIO

Estimate of Photonuclear Reaction in a Medical Linear Accelerator Using a Water-Equivalent Phantom

The Silicon-Tungsten Tracker of the DAMPE Mission

Interaction of particles with matter - 2. Silvia Masciocchi, GSI and University of Heidelberg SS2017, Heidelberg May 3, 2017

Radiation (Particle) Detection and Measurement

SciBar and future K2K physics. F.Sánchez Universitat Aútonoma de Barcelona Institut de Física d'altes Energies

NGRM Next Generation Radiation Monitor new standard instrument for ESA

Transcription:

SCIPP Towards Proton Computed Tomography L. R. Johnson, B. Keeney, G. Ross, H. F.-W. Sadrozinski, A. Seiden, D.C. Williams, L. Zhang Santa Cruz Institute for Particle Physics, UC Santa Cruz, CA 95064 V. Bashkirov, R. W. M. Schulte, K. Shahnazi Loma Linda University Medical Center, Loma Linda, CA 92354 Proton Energy Loss in Matter Proton Tomography / Proton Transmission Radiography Proton Transmission Radiography Data Proton Transmission Radiography MC Study

Computed Tomography (CT) CT: Based on X-ray absorption Faithful reconstruction of patient s anatomy Stacked 2D maps of linear X-ray attenuation Coupled linear equations Invert matrices and reconstruct z- dependent features Proton CT: replaces X-ray absorption with proton energy loss reconstruct mass density (ρ) distribution instead of electron distribution X-ray tube Detector array

Radiography: X-rays vs. Protons Attenuation of Photons, Z N(x) = N o e - µ x Energy Loss of Protons, ρ E = de dx dx de ρ dx l µ 10 4 100 [1/cm] 1 X-Ray Absorption Coefficient Bone Muscle H2O Fat 0.01 1 1 10 100 1000 10 100 1000 X-Ray Energy [kev] NIST Data Proton Energy E [MeV] Measure statistical process of X-ray removal 100 de/dl [MeV/cm] 10 Stopping Power for Protons de dl de = ρ dx Bethe-Bloch Low Contrast: ρ = 0.1 for tissue, 0.5 for bone Bone Muscle H2O Fat Measure energy loss on individual protons

Negative Slope in the Bethe-Bloch Formula 300 Proton Energy Loss in H 2 O 10 Relatively low entrance dose (plateau) Maximum dose at depth (Bragg peak) Rapid distal dose fall-off 200 Proton Energy [MeV] 100 E = 130 MeV E = 250 MeV Energy Deposit in 1mm [MeV/mm] 5 RBE close to unity 0 0 0 10 20 30 40 50 Water Depth [cm] Imaging Treatment

Protons vs. X-Rays in Therapy Protons: Energy modulation spreads the Bragg peak across the malignancy X-rays: High entrance dose Reduced dose at depth Slow distal dose fall-off leads to increased dose in non-target tissue

Milestones of Proton Computed Tomography R. R. Wilson (1946) Points out the Bragg peak, defined range of protons A. M. Cormack (1963) M. Goitein (1972) Tomography 2-D to 3-D, Simulations A. M. Cormack & Koehler (1976) K. M.Hanson et al. (1982) U. Schneider et al. (1996) Tomography, ρ 0.5 % Human tissue, Dose advantage Calibration of CT values, Stoichiometric method T. J. Satogata et al. (Poster M10-204) Reduced Dose of Proton CT compared to X-Ray CT

What is new in pct? SCIPP Increased # of Facilities with gantries etc. See the following talk by Stephen G. Peggs) 2 Ph.D. Theses at PSI and Harvard Cyclotron (U. Schneider & P. Zygmanski) Existence of high bandwidth detector systems for protons semiconductors high rate data acquisition ( > MHz) large-scale (6 wafers) fine-grained (100 s um pitch) Concerted simulation effort Exploitation of angular and energy correlations Support of data analysis Optimization of pct set-up (detector, energy,..) Dose calculation

Potential of Proton CT: Treatment Planning X-ray CT use in proton cancer therapy can lead to large uncertainties in range determination Range Uncertainties (measured with PTR) > 5 mm > 10 mm > 15 mm Schneider U. & Pedroni E. (1995), Proton radiography as a tool for quality control in proton therapy, Med Phys. 22, 353. Alderson Head Phantom Proton CT can measure the density distribution needed for range calculation. There is an expectation (hope?) that with pct the required dose can be reduced.

Low Contrast in Proton CT Sensitivity Study: Inclusion of 1cm thickness and density ρ at midpoint of 20cm H 2 O 1 0.8 Energy Loss in Water ρ l [g/cm 2 ] 1.0 1.1 ρ Energy [MeV] 164.1 163.6 Range [cm] 38.2 38.1 TOF [ps] 1309 1311 0.6 Energy Loss 0.4 [MeV/mm] 0.2 2500 200 Proton Energy [MeV] de (250) de (250)+1.1 de (250)+1.5 de (250)+2 Proton Energy ρ 1.0 1.1 1.5 2.0 1.5 2.0 161.5 158.9 37.7 37.2 1317 1325 150 0 5 10 15 20 25 Depth in H 2 O [cm]

Requirements for pct Measurements Tracking of individual Protons requires Measurement of: Proton location to few hundred um Proton angle to much better than a degree Multiple Coulomb Scattering Θ MCS 1 o θ CMS 13.6MeV β p z l / X 0 Average Proton Energy <E> to better than % Improve energy determination with statistics σ = < E> σ E N Issue: Dose D = Absorbed Energy / Mass N/A = Fluence ( for Voxel with diameter d = 1mm 10 5 protons of 200 MeV = 7 [mgy]) D = A N de dx In order to minimize the dose, the final system needs the best energy resolution! Energy straggling is 1-2 %. σ E 1%

Dose vs. Voxel Size for pct Measurements Trade-off between Voxel size and Contrast ( ρ ρ) to minimize the Dose Define voxel of volume d 3 Dose in voxel = D v Take n =20cm/d settings Total dose D = n* D v Dose [mgy] 1 pct: Contrast - Voxel Size - Dose 200 MeV Protons, 3Stdv. 1 0.01 0.01 Require 3σ Significance D ~ 2 σ E 2 ρ d 5 0.0001 10-6 Voxel Diameter d=5mm, Si d=2mm, 2% d=5mm, 2% d=1cm, 2% 0.01 0.1 1 10 Density Difference [g/cm 3 ] 0.0001 10-6

Studies in Proton Computed Tomography Collaboration Loma Linda University Medical Center UC Santa Cruz Exploratory Study in Proton Transmission Radiography Silicon detector telescope Simple phantom in front Understand influence of multiple scattering and energy resolution on image Theoretical Study (GEANT4 MC simulation) Evaluation of MCS, range straggling, and need for angular measurements Optimization of energy

Exploratory Proton Radiography Set-up Proton Beam from Loma Linda University Medical Ctr @ 250 MeV Degraded down to 130 MeV by 10 wax block Object is aluminum annulus 5 cm long, 3 cm OD, 0.67 cm ID Very large effects expected, x = ρ*l = 13.5 g/cm 2 Traversing protons have 50 MeV, by-passing protons have 130 MeV Silicon detector telescope with 2 x-y modules: measure energy and location of exiting protons Wax block Air Air Object Beam from Synchrotron 30 cm 27.3 cm y x Si Modules x y 250MeV 130MeV 50 + 130MeV

Silicon Detector Telescope Simple 2D Silicon Strip Detector (SSD) Telescope of 2 x-y modules built for Nanodosimetry 2 single-sided SSD / module measure x-y coordinates GLAST Space Mission developed SSD 194 µm pitch, 400 µm thickness 6.4 cm GLAST Readout 1.3 µs shaping time Binary readout Time-over-Threshold TOT Large dynamic range 6.4 cm 5 x 64 channels

Time-Over-Threshold ~ Energy Transfer Digitization of position (hit channel) and energy deposit (TOT) Time-over-Threshold TOT TOT charge LET TOT Measurement vs Charge 120 Pulse Threshold 100 80 TOT [us] 60 40 20 0 0 50 100 150 200 Input Charge [fc]

300 250 200 150 100 50 TOT Spectra for Low-energy Protons Calibration of Proton Energy vs. TOT 250MeV 40MeV 24MeV 17MeV 0 0 50 100 150 TOT [us] Good agreement between measurement and MC simulations TOT [us] 100 TOT vs Proton Energy Measurement and Expectation TOT Saturation ToT measured TOT expected σ /Ε Ε 0.4 0.3 0.2 Proton Energy Resolution 0.4 0.3 0.2 10 LLUMC Synchrotron P Beam 10 100 1000 10 4 Proton Energy [MeV] GLAST SLAC Test Beam 0.1 0.1 0 0 10 100 1000 Proton Energy [MeV] Derive energy resolution from TOT vs. E plot

Image of Al Annulus Subdivide SSD area into pixels 1. Strip x strip 194um x 194um 2. 4 x 4 strips (0.8mm x 0.8mm) Image corresponds to average energy in pixel

Energy Resolution => Position Resolution Slice of average pixel energy in 4x4 pixels (need to apply off-line calibration!) Hole filled in Fuzzy Edges Clear profile of pipe, but interfaces are blurred

Image Features: Multiple Scattering: Migration Washed out image in 2 nd plane (30cm downstream) Energy diluted at interfaces (Fuzzy edges, Large RMS, Hole filled in partially) Migration of events are explained by Multiple Coulomb Scattering MCS Protons scatter OUT OF target (not INTO). Scatters have larger energy loss, larger angles, fill hole, dilute energy

GEANT4 MC: Use of Angular Information Si Telescope allows reconstruction of beam divergence and scattering angles Select 2 Areas in both MC and Data A = inside annulus : Wax + Al B = outside annulus : Wax only Angular distributions well understood

GEANT4 MC: Migration Beam profile in slice Migration out of object Energy of protons entering front face Protons entering the object in front face but leaving it before the rear face

GEANT4 MC: Use of Angular Information Angular Cut at Θ MCS of the Wax Less Migration Energy Profile before (after ) Angle Cut Sharp Edges (Energy Average) Sharp Edges (Energy RMS) Angular cut improves the contrast at the interfaces Energy RMS before (after ) Angle Cut

Present status of pct: Conclusions Long tradition, increased interest with many new proton accelerators (see next talk by Stephen G. Peggs) pct will be useful for treatment planning (reconstruction of true density distribution) Potential dose advantage wrt X-rays ( see Poster M10-204 by Satogata et al. ) Use of GEANT4 simulation program aids in planning of experiments Our future plans: Optimization of beam energy (correlation of energy and angle, migration ) (see Poster M6-2, L. R. Johnson et al.) Investigation of optimal energy measurement method Dose contrast - resolution relationship on realistic phantoms