Optics lab 2. Kai Beckwith. Laboratory date: Delivery date: Revision delivery date:

Similar documents
Major Concepts Langevin Equation

Brownian motion using video capture

Assignment 3: The Atomic Nature of Matter

Endres 1. Mackenzie Endres. An Experimental Exploration into Brownian Motion: Size Dependence and the Boltzmann s Constant

University of Leipzig Faculty of Physics and Earth Science Institute for Experimental Physics I Department of Soft Matter Physics

CHE3935. Lecture 10 Brownian Dynamics

PHYS 391 Lab 2: Brownian Motion

Twenty-six year old patent clerk in Bern, Switzerland

Brownian Motion and The Atomic Theory

How DLS Works: Interference of Light

Introduction to Nanoparticle Tracking Analysis (NTA) Measurement Principle of ZetaView

Origins of Modern Physics

EXPERIMENT 17. To Determine Avogadro s Number by Observations on Brownian Motion. Introduction

Visualize and Measure Nanoparticle Size and Concentration

BROWNIAN MOTION. 1 Introduction. 2 Theory. Physics 120 General Physics I

Smoluchowski Symposia: Why are we here?

Systematic Analysis for Ultra-fast Single-Particle Tracking in Live Cells

Evidence for the Quantization of Electric Charge and Measurement of the Fundamental Unit of Electric Charge

ROBERT BROWN AND THE POLLEN STUFF

Computational Neuroscience. Session 2-1

Seeing the Nano-scale: Nanoparticle Tracking Analysis HVM MNT Expo 2006 Oxford. Jeremy Warren CEO, NanoSight Ltd

Entropic forces in Brownian motion

Experimental biophysics: Optical tweezer lab Supervisor: Stefan Holm,

Brownian Motion. Experiment BM. University of Florida Department of Physics PHY4803L Advanced Physics Laboratory

CHAPTER V. Brownian motion. V.1 Langevin dynamics

Collision and Oxidation of Silver Nanoparticles on a Gold Nanoband Electrode

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

REVIEW: Waves on a String

GEOMETRICAL OPTICS Practical 1. Part II. OPTICAL SYSTEMS

Particle size analysis -Chapter 3

PAF Chapter Comprehensive Worksheet May 2016 Science Class 7 (Answering Key)

Lecture 3: From Random Walks to Continuum Diffusion

Supporting Information

This is a Gaussian probability centered around m = 0 (the most probable and mean position is the origin) and the mean square displacement m 2 = n,or

Particle Size Determinations: Dynamic Light Scattering: page 161 text

Supporting Information. Even Hard Sphere Colloidal Suspensions Display. Fickian yet Non-Gaussian Diffusion

Year 7 Science. 7C1: The Particle Model. PPA Challenge

The theory of Brownian motion one hundred years old

INDUCE NANOSTRUCTURES WITH ELECTRIC FIELDS

Math 345 Intro to Math Biology Lecture 21: Diffusion

Module 5: Rise and Fall of the Clockwork Universe. You should be able to demonstrate and show your understanding of:

Supplementary table I. Table of contact angles of the different solutions on the surfaces used here. Supplementary Notes

Brownian Motion and Single Particle Tracking

FLOW VISUALIZATION OF FERROMAGNETIC NANO- PARTICLES ON MICROCHANNEL FLOW USING DARK FIELD MICROSCOPY

5. 3P PIV Measurements

MILLIKAN OIL-DROP EXPERIMENT. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin Abstract

Measuring Viscosity. Advanced Higher Physics Investigation. Jakub Srsen SCN: Boroughmuir High School Center Number:

Lab 7: Brownian Motion

Optical Tweezers. BGGN 266, Biophysics Lab. June, Trygve Bakken & Adam Koerner

4. The Green Kubo Relations

Dynamic Self Assembly of Magnetic Colloids

Analyzing SHO of a double pendulum

LAB 3: Confocal Microscope Imaging of single-emitter fluorescence. LAB 4: Hanbury Brown and Twiss setup. Photon antibunching. Roshita Ramkhalawon

CHAPTER 16 A MACROSCOPIC DESCRIPTION OF MATTER

CHAPTER TWO: EXPERIMENTAL AND INSTRUMENTATION TECHNIQUES

Fractal trajectories of the dynamical system

Topics covered so far:

The structure of Atom I

Biophysics I. DIFFUSION

File ISM02. Dynamics of Soft Matter

Statistical Mechanics

Particle Dynamics: Brownian Diffusion

Optical Trapping Experiment - Optical Tweezers. PHY 431 Optics, Fall 2011

Biological and Medical Applications of Pressures and Fluids. Lecture 2.13 MH

Einstein Classes, Unit No. 102, 103, Vardhman Ring Road Plaza, Vikas Puri Extn., Outer Ring Road New Delhi , Ph. : ,

Why Complexity is Different

Moonbows. Friday somebody asked if rainbows can be seen at night.

Guidance for Writing Lab Reports for PHYS 233:

School. Team Number. Optics

ENVR 416 Aerosol Technology - Laboratory Session Fall 2007

What are the odds? Coin tossing and applications

Application of Micro-Flow Imaging (MFI TM ) to The Analysis of Particles in Parenteral Fluids. October 2006 Ottawa, Canada

Capturing and Processing Planetary Images. Petros Pissias Eumetsat Astronomy Club 11/06/2015

Refractive index determination of single sub micrometer vesicles in suspension using dark field microscopy

Direct observation of aggregative nanoparticle growth: Kinetic modeling of the size distribution and growth rate

(From the Laboratory of General Physiology, Harvard University, Cambridge)

Digital Holographic Measurement of Nanometric Optical Excitation on Soft Matter by Optical Pressure and Photothermal Interactions

Basic structure of SEM

SUPPLEMENTARY INFORMATION

Physics 104 Exam 3 April 24, Name ID # Section # TA Name

Confocal Microscopy Imaging of Single Emitter Fluorescence and Hanbury Brown and Twiss Photon Antibunching Setup

Experimental Optics. Optical Tweezers. Contact: Dr. Robert Kammel, Last edition: Dr. Robert Kammel, February 2016

Supporting Information

Physics 208 Exam 1 Oct. 3, 2007

TEST BANK FOR PRESCOTTS MICROBIOLOGY 9TH EDITION BY WILLEY SHERWOOD WOOLVERTON

Supplementary Information. SI Text 1: Derivation and assumptions of the effective temperature model

A Quantum Gas Microscope for Detecting Single Atoms in a Hubbard regime Optical Lattice

Droplets and atoms. Benjamin Schumacher Department of Physics Kenyon College. Bright Horizons 35 (July, 2018)

Foundations of. Colloid Science SECOND EDITION. Robert J. Hunter. School of Chemistry University of Sydney OXPORD UNIVERSITY PRESS

C1a The particulate nature of matter

MILLlKAN S OIL DROP EXPERIMENT

How to measure the zeta potential of individual Nanoparticles (NPs)? To anticipate the answer: With the

Magnifying Glass. Angular magnification (m): 25 cm/f < m < 25cm/f + 1. image at 25 cm (= normal near point) relaxed eye, image at (normal) far point

PHYS 1112 In-Class Exam #1, Version D

Lecture 6 Examples and Problems

Chapter 7 Notes. Matter is made of tiny particles in constant motion

Diffusion and Osmosis

A sound wave needs a medium through which it is transmitted. (MS-PS4-2)

Errata for The Feynman Lectures on Physics Volume I New Millenium Edition (1 st printing)

Transcription:

Optics lab 2 Kai eckwith Laboratory date: 20.02.08 Delivery date: 04.03.08 Revision delivery date: 31.03.08 Abstract In the second optics lab we use light microscopy and computer tracking software to estimate the oltzman konstant (k ) by studying the brownian motion of 1µm particles dispersed in water. The experiment showed that when adjusting the equipment correctly relatively accurate values of k were estimated, but only specific configurations of the microscope and tracking software could be used to obtain reliable data. 1 Introduction When small particles are dispersed in a liquid they are subject to brownian motion (background information in section 2.2). The distribution of step sizes in the brownian motion is related to the thermal energy of the system, which again is given by the temperature and the olzman constant. Thus by observing and recording the random motion of the particles, tracking the particle walks, and employing statistical models on the data we can estimate the value of the olzman constant. 2 Theory 2.1 Optical microscopy Optical lab 1 was an introduction to optical microscopy and the techniques described there are applicable for this lab. For the general theory and additional details behind optical microscopy see Optics lab 1 by Kai eckwith, 20.02.08 ([1]). 2.2 rownian motion rownian motion was first discovered and described by Robert rown in 1827 [2]. He concluded that the movement of the particles later named of him was not caused by external forces such as movement in the liquid, but only the particles themselves. Despite being 1

partly wrong, he did discover this very important effect. Albert Einstein was the first to mathematically characterize the brownian motion, and also give a physical interpretation of the phenomenon [3]. Small particles, such as watermolecules in the rown s case, are constantly crashing into a large particle, such as the pollen grain, at a very high pace. ut each collision causes only a very small displacement of the pollengrain, at the same time as so many collisions happen each second that it would be impossible to observe the motion caused by this. ut Einstein solved this problem by combining the two effects with statistical theory: Once in a while there will be a discrepancy in the amount of bombardments from one side compared to the other, and the particle will lurch a relatively large step in the opposite direction, which is what we then see as brownian motion. Using thermodynamics, diffusion theory and statistics, he obtained several useful formulas which will be discussed now. The diffusion constant for spherical particles is given by D = RT N6πηP, (1) where R is the universal gas constant (8.315 J/K mol), related to the olzman constant by R = k N. T is the temperature in Kelvin, N is Avogadro s number (6, 022 10 23 ), η is the viscosity of the liquid and P is the radius of the sphere. The probability of a certain displacement along a given axis can be calculated for a certain time interval τ by assuming the step sizes follow a Gaussian distribution (normal distribution). Relating the step time to the diffusion constant Einstein obtained: λ x = 2Dτ, (2) where λ x is the expected (mean) dislplacement in the time interval τ. Thus by measuring the mean displacement during a given time interval, we can estimate D and thus find the value of k, assuming the other variables are known. 2.3 Measuring k As mentioned in section 2.2 we can find D and thus k by measuring the mean distance a particle moves during a given time. If we use several particles and set up a distribution of step sizes, we can get relatively accurate values of k. This method is described in a 2002 paper by Paul Nakroshis et. al. [4]. The tracking is done by first taking a small video using the imaging software ImageJ, then using a tracking plugin to obtain particle trajectories. For the tracking plugin to work, the video has to be converted to 8-bit greyscale colouring, inverted, and the contrast and brightness needs to be adjusted until the particles are all that are visible. The trajectories are then output as a text file which gets imported into matlab. In matlab this data is used 2

to compile a histogram of the distribution of step sizes. The histogram is normalized and fit with a gaussian distribution, and from the gaussian distribution we can establish the diffusion constant, and k. The error in the results is estimated using standard statistics approach to measuring the sample variance. The sample deviation is given by S = 1 N (X i N 1 X) 2 (3) where N is the amount of samples, X i is the value of the given sample and X = 1 N N i=1 X i is the mean of the samples. S is the sample variance, and it s computed value is denoted s. i=1 3 Experiment 3.1 Sample The sample used was spherical polystyrene particles with a diameter of 1µm. These particles where dispered in clean water at room temperature, 19 degrees C. The sample was put onto a dimpled microscope slide, covered with a cover slide, and put into the microscope for study. 3.2 Adjustment The microscope was of the model Leica DMLS, a standard optical microscope with magnifications ranging from 10X to 100X. The 100X objective is an oil objective. The microscope was first adjusted at 20X magnification using Köler s principle[1] to obtain maximum contrast. The condenser aperture[5] was opened to decrease the depth of field (DOF), because in this experiment it was important to view only a limited amount of particles which where in focus. right field[1] was chosen as method, due to the type of sample used. The sample was not transparent enough for phase contrast to give a significant advantage, nor was did it scatter enough for dark field to be advantageous. Figure 1 shows the end result after the microscope was adjusted to optimal settings, but before any digital enhancements were done to the image. 3

Figure 1: right field image of the 1µm particles at 20X magnification (not to scale, only for comparison purposes). The depth of field was tweaked to obtain maximum detail on particles in a single plane. 4

4 Results 4.1 Measurements with 20X magnification lens The first measurements were done by two videos at 20X magnification, 100 frames at 7,5fps. Figure 2 shows the image after editing to make the tracking software as accurate as possible. Figure 2: Image taken under similar conditions as figure 1, but after digital manipulation for maximum contrast. Using the methods described in section 2.2 and 2.3 we obtain results for k based on steps in x-direction and y-direction. The results were: k x 1 k y 1 k x 2 k y 2 = 5, 919 10 21 = 5, 129 10 21 = 3, 064 10 21 = 4, 002 10 21 k = 4, 529 10 21 k (292K) = 4, 06 10 21, where the first four are the actual results, k is the avarage result, and k (292K) is the real value of k at 19 degrees C. The error of k is calculated using the method in the end of section 2.3, which gives an error (sample deviation) of ±1, 61 10 21 for the above data. 5

4.2 Other measurements Magnifications of 40X and 10X where tried, using exactly the same technique as above. The results at 40X where very widely spread, giving no conclusive results. In the tracking software the number of trajectories measured varied between 500-1000, despite there only being between 10-20 particles in the video at a given time. The same happened for 10X magnification. See section 5 for discussion as to why this could be. 5 Discussion For 20X magnification we obtained results that under more controlled experiment conditions and with more repeats could yield accurate results for the oltzman constant. The totally inconclusive and widely spread results for both 10X and 40X magnification indicates that the tracking program has trouble tracking the particles accuratly. For 40X the reason is probably due to the particles movement along the z-axis. Although the program is supposed to correct for this, it appears not to do so adequately. When the particles move along the z- axis and appear and disappear from the focal plane, they get registered as different particles. This is also indicated by the high trajectory count despite a limited amount of particles. For 10X magnification a similar, but different problem occurs. Due to lower magnification, the DOF increases, causing more particles to appear and disappear into the focal plane. This was impossible to regulate, despite extensive time spent adjusting the microscope and capturing software. Therefore a huge amount of trajectories was tracked, and we get similarily diverging results. Other sources of error that can be considered are agglomeration of the polymer particles, especially in regions close to air/water bounderies where the particles have been known to self-assemble. To counteract this areas where no such agglomeration was present was chosen for the samples. Particles near the glass slide might also not move in a completely random brownian motion, du to electrostatic or other influences from the glass. ut due to using samples from different depths and diverging results regardless, this problem is likely dwarfed by the tracking problems described above. 6 Conclusion Our results show that 20X magnification seems to be the optimal setting for this experiment, as 10X proved too low and 40X proved too high. With the correct settings this method gives a way to estimate the olzmann constant relatively accurately, and it also proves again Einstein s postulates about random motion and diffusion. Obtaining good results proved to be hard unless optimal settings were used, showing that correct adjustment and use of the equipment is as important for the experiment as a good sample. Knowing the limits of the equipment and possible sources of error can also make the error seeking process easier, and save a lot of time during the experiment. 6

References [1] Lab report: Optics lab 1 by Kai eckwith, 20.02.08. Contact beckwith@stud.ntnu.no for details and access. [2] rown, Robert, A brief account of microscopical observations made in the months of June, July and August, 1827, on the particles contained in the pollen of plants; and on the general existence of active molecules in organic and inorganic bodies. Phil. Mag. 4, 161-173, 1828. [3] Einstein, A. (1905), Über die von der molekularkinetischen Theorie der Wrme geforderte ewegung von in ruhenden Flssigkeiten suspendierten Teilchen., Annalen der Physik 17: 549-560 [4] Paul Nakroshis, Matthew Amoroso, Jason Legere, and Christian Smith, Measuring oltzmanns constant using video microscopy of rownian motion, Am. J. Phys. 71 (6), June 2003 [5] Pawel Sikorski, Section 2.1, Laboratory in TFY4330: Light Microscopy Exercises 1 and 2, February 1, 2008. 7