Performance of the AMS-02 Electromagnetic Calorimeter in Space

Similar documents
High-energy Gamma Rays detection with the AMS-02 electromagnetic calorimeter. F. Pilo for the AMS-02 ECAL Group INFN Sezione di Pisa, Italy

THE ELECTROMAGNETIC CALORIMETER OF THE AMS-02 EXPERIMENT

Precision measurements of nuclear CR energy spectra and composition with the AMS-02 experiment

Chapter 6.2: space based cosmic ray experiments. A. Zech, Instrumentation in High Energy Astrophysics

AMS : A Cosmic Ray Observatory

Dark Matter Searches with AMS-02. AMS: Alpha Magnetic Spectrometer

Cosmic Ray Physics with the Alpha Magnetic Spectrometer

arxiv: v1 [physics.ins-det] 3 Feb 2014

The AMS-02 Anticoincidence Counter

THE AMS RICH COUNTER

Dark Matter Particle Explorer: The First Chinese Cosmic Ray and Hard γ-ray Detector in Space

Preliminary results from gamma-ray observations with the CALorimeteric Electron Telescope (CALET)

The Latest Results from AMS on the International Space Station

PAMELA: a Satellite Experiment for Antiparticles Measurement in Cosmic Rays

CALET INSTRUMENT. Calorimeter CGBM

Correction for PMT temperature dependence of the LHCf calorimeters

Simulation and validation of the ATLAS Tile Calorimeter response

PAMELA satellite: fragmentation in the instrument

SUPPLEMENTARY INFORMATION

Operation and Performance of the AMS-02 Silicon Tracker

The Large Area Telescope on-board of the Fermi Gamma-Ray Space Telescope Mission

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Justin Vandenbroucke (KIPAC, Stanford / SLAC) for the Fermi LAT collaboration

The GILDA mission: a new technique for a gamma-ray telescope in the energy range 20 MeV GeV

New results from the AMS experiment on the International Space Station. Henning Gast RWTH Aachen

The space mission PAMELA

Validation of Geant4 Physics Models Using Collision Data from the LHC

Antimatter and DM search in space with AMS Introduction. 2 Cosmology with Cosmic Rays

Indirect Search for Dark Matter with AMS-02

The PAMELA Satellite Experiment: An Observatory in Space for Particles, Antiparticles and Nuclei in the Cosmic Rays

Studies of Hadron Calorimeter

A gas-filled calorimeter for high intensity beam environments

Indirect Dark Matter Detection

1 The beginning of Cosmic Ray Physics, the balloons BACKGROUND REJECTION AND DATA ANALYSIS. Aldo Morselli a and Piergiorgio Picozza a.

Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics. PAMELA MissioN 17 December 2010 Prepared by FatiH KAYA

Status of the PAMELA silicon tracker

1 Introduction STATUS OF THE GLAST LARGE AREA TELESCOPE. SLAC-PUB December Richard Dubois. Abstract

Cosmic Ray panorama. Pamela.roma2.infn.it PAMELA (2012) Experimental challenges : e + /p ~ 10-3 e + /e - ~ 10-1

Temperature Dependence Calibration and Correction of the DAMPE BGO Electromagnetic Calorimeter

Upgrade of the CMS Forward Calorimetry

PHY326/426 Dark Matter and the Universe. Dr. Vitaly Kudryavtsev F9b, Tel.:

GRAINE Project: a balloon-borne emulsion gamma-ray telescope

The Ring Imaging Cherenkov detector of the AMS experiment: test beam results with a prototype

Measurements of Heavy Nuclei with the CALET Experiment

The NUCLEON Space Experiment Preliminary Results. Skobeltsyn Institute of Nuclear Physics, Moscow State University, Moscow, , Russia

Calorimetry I Electromagnetic Calorimeters

GeV to Multi-TeV Cosmic Rays: AMS-02 Status and Future Prospects

SIMULATION OF THE GAMMA-RAY GALACTIC DISTRIBUTION AS SEEN BY THE AMS-02

Precision neutron flux measurement with a neutron beam monitor

PoS(DIS 2010)058. ATLAS Forward Detectors. Andrew Brandt University of Texas, Arlington

Future prospects for the measurement of direct photons at the LHC

Examples for experiments that can be done at the T9 beam line

PoS(ICRC2017)208. Particle tracking in the CALET experiment. Paolo Maestro (for the CALET Collaboration)

CALICE scintillator HCAL

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

Muon reconstruction performance in ATLAS at Run-2

Calorimetry in particle physics experiments

Particle Energy Loss in Matter

Commissioning and Calibration of the Zero Degree Calorimeters for the ALICE experiment

P A M E L A Payload for Antimatter / Matter Exploration and Light-nuclei Astrophysics

The Alpha Magnetic Spectrometer on the International Space Station

The Fast Interaction Trigger Upgrade for ALICE

Introduction to Cosmic Rays Data Analysis Issues. Nicola De Simone INFN and University of Rome Tor Vergata

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

AIM AIM. Study of Rare Interactions. Discovery of New High Mass Particles. Energy 500GeV High precision Lots of events (high luminosity) Requirements

Ionization Energy Loss of Charged Projectiles in Matter. Steve Ahlen Boston University

The Fermi Gamma-ray Space Telescope

CALICE Test Beam Data and Hadronic Shower Models

1 Introduction. KOPIO charged-particle vetos. K - RARE Meeting (Frascati) May Purpose of CPV: veto Kl

Calibration of the BABAR CsI (Tl) calorimeter

Track measurement in the high multiplicity environment at the CBM Experiment

Particle Detectors A brief introduction with emphasis on high energy physics applications

DARK MATTER SEARCHES WITH AMS-02 EXPERIMENT

David Gascón. Daniel Peralta. Universitat de Barcelona, ECM department. E Diagonal 647 (Barcelona) IFAE, Universitat Aut onoma de Barcelona

Dual readout with tiles for calorimetry.

Measurement of the neutron fraction event-byevent

Particle Energy Loss in Matter

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

PoS(ICRC2017)168. PSD performance and charge reconstruction with DAMPE

AMS-02 measurement of cosmic ray positrons and electrons

The Silicon-Tungsten Tracker of the DAMPE Mission

Last Lecture 1) Silicon tracking detectors 2) Reconstructing track momenta

Theory English (Official)

arxiv: v1 [hep-ex] 18 Feb 2009

PoS(Vertex 2016)004. ATLAS IBL operational experience

Primary Cosmic Rays : what are we learning from AMS

The new event analysis of the Fermi Large Area Telescope

Interaction of particles in matter

PEBS - Positron Electron Balloon Spectrometer. Prof. Dr. Stefan Schael I. Physikalisches Institut B RWTH Aachen

ATLAS EXPERIMENT : HOW THE DATA FLOWS. (Trigger, Computing, and Data Analysis)

Timing calibration of the LHAASO-KM2A electromagnetic particle detectors

THE ATLAS TRIGGER SYSTEM UPGRADE AND PERFORMANCE IN RUN 2

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

Particle Flow Algorithms

IceCube. francis halzen. why would you want to build a a kilometer scale neutrino detector? IceCube: a cubic kilometer detector

University of California, Los Angeles, CA 90095, USA

Experimental review of high-energy e e + and p p spectra

Neutral particles energy spectra for 900 GeV and 7 TeV p-p collisions, measured by the LHCf experiment

Tracking properties of the ATLAS Transition Radiation Tracker (TRT)

Transcription:

Journal of Physics: Conference Series OPEN ACCESS Performance of the AMS-02 Electromagnetic Calorimeter in Space To cite this article: G Gallucci and the AMS-02 ECAL group 2015 J. Phys.: Conf. Ser. 587 012028 View the article online for updates and enhancements. Related content - Performance of the AMS02 Electromagnetic Calorimeter in space Sylvie Rosier-Lees and on behalf of the AMS02 collaboration) - Dead cell and side leakage correction for a lead-scintillating fiber electromagnetic calorimeter * Cheng Zhang, Zu-Hao Li, Zhi-Cheng Tang et al. - Correction of PMT position effect for a lead-scintillating fiber electromagnetic calorimeter Li Zu-Hao, Wang Ling-Yu, Xu Wei-Wei et al. Recent citations - New developments in calorimetric particle detection Richard Wigmans - The spectrum of darkonium in the Sun Chris Kouvaris et al This content was downloaded from IP address 148.251.232.83 on 06/10/2018 at 03:19

Performance of the AMS-02 Electromagnetic Calorimeter in Space G.Gallucci ( for the AMS-02 ECAL group) INFN - Sezione di Pisa, Largo Bruno Pontecorvo 3, 56127 Pisa, Italy E-mail: giovanni.gallucci@pi.infn.it Abstract. AMS-02(Alpha Magnetic Spectrometer) is an high energy particle detector developed to operate on the International Space Station. AMS-02 was installed on ISS on May 2011 and is expected to operate for 10-20 years collecting about 160-320 billions of events. The main goals of the experiment are the detection of primordial antimatter and dark matter by studying spectra and flux of different cosmic ray components (protons, electrons, nuclei, positrons, antiprotons, gamma rays, etc) in the high energy range (1-2000 GeV). Identification of electrons, positrons and photons is provided by the Electromagnetic Calorimeter (ECAL), a fine grained lead-scintillating fibers sampling calorimeter that allows for a precise threedimensional imaging of the longitudinal and lateral shower development. It provides an excellent reconstruction of electromagnetic shower energy and a highly efficient rejection of the hadronic background. Thanks to the 3D shower reconstruction capability, ECAL allows a stand-alone determination of the incoming particle direction, with unprecedented angular resolution. As a result, ECAL is able to identify high energy photons coming from galactic or extragalactic sources. 1. The AMS-02 Experiment The AMS-02 is a TeV precision multipurpose spectrometer designed to operate in space, outside the International Space Station (ISS). Its launch and subsequent installation on the ISS took place successfully on May 2011. The main goals of AMS are the precise measurements of cosmic ray composition and flux (protons, electrons, ions, strange matter, etc...), the indirect search of Dark Matter (positron fraction, anti-proton fraction, etc...) and search and study of primordial anti-matter (anti-helium, etc...). Moreover, it could study the diffused gamma rays in the GeV to TeV range. 2. The AMS-02 Detectors The layout of AMS-02 detector consists of a Transition Radiation Detector (TRD), a Time of Flight (TOF), a Magnetic spectrometer, an Anti-Coincidence scintillator counter system (ACC), a Ring Image Cherenkov (RICH) and an electromagnetic calorimeter (ECAL) as shown in figure 1: The TRD is composed by 5248 proportional tubes of 6mm diameter and maximum length of 2 m filled with Xe and CO2 (90:10 mixture). The tubes are organized in 16- tube modules and mounted in 20 layers. Between two layers there is a 20 mm thick polypropylene/polyethylene radiator. The TRD is used to distinguish between electrons and protons up to few hundred GeVs and to independently identify nuclei using de dx [1]. Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by IOP Publishing Ltd 1

16th International Conference on Calorimetry in High Energy Physics (CALOR 2014) IOP Publishing The TOF consists of four planes of plastic scintillators. Each plane contains eight or ten paddles and each paddle is readout by two or three phototubes on each end. It is used for charged particle triggers, timing information, beta and de/dx measurements[2]. The Magnetic spectrometer is composed by a silicon tracker (TRK) and a permanent magnet of 0.14 Tesla. The TRK is made by 192 ladders, each containing double-sided silicon sensors, mounted on 9 layers. Seven layers are in inside the magnet volume and constitute the inner tracker. One layer is located on top of TRD and the last one is located between the RICH and the ECAL. The TRK provides the rigidity, the charge and the charge sign of particles [3]. The ACC is made by 16 curved scintillator planes 0.8 m long surrounding the inner tracker inside the magnet. They are used as veto to reject events entering the detector through the sides and, in general, to detect unwanted particles that enter or leave the inner tracker volume transversely [4]. The RICH consists of two dielectric radiators with different refractive index and different beta thresholds. The Cherenkov light is detected by 10880 photosensors of 8.5x8.5 mm2. It is used to measure velocity of cosmic rays [5]. The ECAL is shown in the next section. TRD Identify e+, e- TOF Z, E 1 Silicon Tracker Z, P Magnet ±Z TRD TOF 2 5-6 7-8 ECAL E of e+, e-, γ Tracker 3-4 TOF RICH RICH Z, E 9 ECAL Figure 1. Sketch of the AMS-02 detector with the different sub detectors. 3. The Electromagnetic calorimeter: ECAL The calorimeter has been designed to precisely reconstruct the longitudinal and the lateral profiles of electromagnetic showers and to measure the deposited energy. For these characteristics it is used to provides energy and axis direction of electromagnetic showers as well as reject the protons using the different shape of hadronic showers. 2

3.1. Structure and light collection ECAL is a lead-scintillating fiber sandwich with an active area of 648x648 mm 2 and a thickness of 166mm for a weight of 500 Kg [6]. The calorimeter consists of 9 modules (called superlayers) with a thickness of 18.5 mm (figure 2a). Each superlayer is composed by grooved lead foils alternate with 1mm scintillating fiber layer glued to the foils by mean of optical epoxy. The resulting ECAL volume is 58% of lead, 33% of fibers ( 50000) and the remaining part of optical glue. The fibers run only in one direction so, in order to obtain a 3D image, the 9 modules are stacked with fibers alternatively parallel to x-axis (five superlayers) and y-axis (4 superlayers). Each superlayer is readout by 36 four-anode photomultipliers (PMTs), only at one edge. In order to avoid dead zones the PMTs are place alternatively on the two opposite ends. The entire calorimeter is readout by 324 PMTS, 1296 anodes. Each anode covers an active area equal to 9x9 mm 2 corresponding to 35 fibers called cell (figure 2b). Each cell correspond to 1 radiation length and half Moliere radius. Thus the calorimeter consists of 18 longitudinal independent samplings and 72 lateral samplings. The entire structure corresponds to 17 radiation lengths but only 0.7 nuclear interaction lengths. To maximize light yield and reduce crosstalk between cells, scintillating light is collected by individual light guides wrapped in an aluminum foil with chromium and quartz coating (figure 3). Furthermore for each PMT, the light guides and the front end electronics are shielded from residual magnetic filed by a 1mm thick soft iron square tube(figure 4). In order to have a good linearity in a large energy range (from few MeVs up to about 60 GeVs), each anode signal is split into two different channels and digitized. The first channel (High Gain) is amplified and is sensitive to Minimum Ionizing Particles (MIP) that release around 7 MeV/cell. The second one (Low Gain) is not amplified and is used for high energy measurement. The gain ration between the two is about 33. Also the signal of the last dynode of each PMT is readout to ensure a redundant measurement of energy deposition and to provide input to the trigger logic. 3.2. ECAL trigger ECAL is involved in the trigger for electromagnetic particles and provides a standalone trigger for photons. When a high energy-deposit is recorded in the innermost layers of the calorimeter, a fast signal is generated and processed by the trigger board which can enable the event acquisition. Also the incident particle direction is evaluated by taking, for x and y sides, the average position of the fired PMTs. A cut at 20 degrees is applied to select particles inside AMS-02 geometrical acceptance and reject charged particles entering by side. The efficiency for photons is about 20% at 1 GeV and reaches about 99The one-orbit average ECAL trigger rate is about 115 Hz (approximately 10% of total AMS-02 rate). 4. ECAL calibration and performances at Test Beam ECAL was tested at CERN on H4 and H8 beam lines, alone and after the integration with rest of apparatus. It was exposed to electrons and positrons beams with energy in the range 6-250 GeV and to primary proton beam line of 400 GeV. Using test beam data, equalization and calibrations procedures have been created and verified and the calorimeter performance has been measured. 4.1. Light attenuation In order to measure light attenuation along fibers we used the MIP peak (figure 5). The light attenuation is parametrized using two different attenuation constants, λ s and λ f fast and slow respectively: x λ A(x) = fe f + (1 f)e x λs (1) 3

16th International Conference on Calorimetry in High Energy Physics (CALOR 2014) IOP Publishing 1 2 3 4 5 6 7 8 9 a) b) Figure 2. a) ECAL Structure. b) One of the 9 superlayers of the calorimeter with the footprint of the PMT and single cell superimposed. Figure 3. Scheme of the PMT light collection system. Figure 4. Light guides and polycarbonate support. with A the attenuation factor and x the distance travelled by the light along the fiber. Typical value are f = 0.17,λf = 110mm and λs = 2605mm with a spread shown in figure 5. 4.2. Equalization Equalization is done adjusting each High Voltage so that the cell response to MIP is the same. Because of intrinsic fluctuation of the four different anodes of each PMT and the fact that 84 PMT pairs are fed by the same HV lines, a offline correction is needed. Only HG channels are equalized but HG-LG ratio is constantly evaluated. 4

Figure 5. Left: Typical distribution of MIP signal in an ECAL cell. Right: Light attenuation along the fibers. The two dashed lines represent the typical spread in attenuation. 4.3. Radiation length Using the different electron and positron beams, we measured the X 0 of calorimeter. Figure 6a shows the energy longitudinal distribution for 10 and 180 GeV. The distribution is well parametrized from a Rossi function []. Figure 6b shows the distribution of the max as function of the energy beam and we obtained: X 0 = 0.98 ± 0.02 cm (2) as expected from the project. The total thickness of ECAL, corresponding to 17.0X 0, still contains 75% of energy of 1 TeV electrons. 4.4. Anode Efficiency and rear leakage We observed that anode efficiency in not uniform, in particular it decreases at the cell border with respect to the centre. Farther there is a small dead space at the edge of each cell. This effect appears to be linearly dependent on the ratio between the sum of the maximum energy deposited in each layer (S1) and the sum of (S1) plus the content of the two cells adjacent to the maximum in each layer (S3). This ratio, called S1/S3, tends to 0.5 for particles hitting ECAL between two cells, corresponding to maximal energy loss ( 10%), and to 1 for particles hitting ECAL in the cell centre, corresponding to minimal energy loss. Figure 7 shows the ECAL energy response before and after correction. A second correction is applied to take into account of the energy leakage after the 17 radiation lengths of ECAL. This loss is proportional to the energy deposited in the last part of the shower. We used the energy fraction of the last two layers of ECAL ( 2 X 0 ) and computed the following formula: E true E dep = α(e dep ) + β E LS + γ E 2 LS E dep E dep with E dep the deposited energy corrected for anode efficiency, E LS the deposited energy in the last two layers. α, β and γ has been measured at test beam. α has a slightly energy dependence and it has been corrected using an iterative process. (3) 5

Figure 6. a)typical longitudinal electromagnetic shower profiles for two different beam energies. b)position of the peak of the Rossi function vs the logarithm of the beam energy. A straight fit provides the parameter X 0 in layer units. Figure 7. Energy deposited as a function of the impact point before (histogram) and after ( red dots) impact correction. 4.5. Energy resolution and linearity Using the different energy beams we measured the linearity and the energy resolution of ECAL. The linearity is within 1% in the range 6-250 GeV (figure 8), energy resolution is well 6

parametrized by (figure 9): σ(e) E = (10.4 ± 0.2)% E(GeV ) (1.4 ± 0.1)% (4) Figure 8. The energy linearity is held within 1%. Figure 9. ECAL energy resolution from Test Beam. 4.6. Angular resolution The high granularity of calorimeter allows a good reconstruction of shower axis and, consequently, a good angular resolution. Shower directions, in x and y side, are determined by fitting the axis positions in each layer. Three different methods has been developed to do it: 7

(i) the Centre Of Gravity (COG), evaluated from the energy weighted centres of the cells belonging to the shower: yi (x i )E i y COG (x COG ) = (5) Ei where E i is the energy deposited in the i-th cell and y i (x i ) is its position; (ii) the Neighbour Cells (NC) method, which uses the ratio of the energy deposited in the cells adjacent to the most energetic one as a function of the impinging position; (iii) the Lateral Fit method, in which the energy distribution of the cells in the layer is fitted using the following parametrization: f(x) = 2(x x C )R 2 ((x x C ) 2 + R 2 ) 2 (6) where the lateral width R and the axis position x C are the output of the fit. Figure 10 summarizes angular resolution for the three methods. Figure 10. Angular resolution as a function of Test Beam momentum for the three analysis methods. 5. ECAL performances on flight The launch was a very stressing test for apparatus. Otherwise the hard environment conditions in the space needed for a continuously monitoring of calorimeter response and performance. After three years of data taking no major problems have happened and only 1 PMT is dead and 1 PMT is noisy. No fiber aging has been observed. 8

5.1. Equalization and light attenuation Using cosmic ray MIPs it is possible to perform the same tests and measurement done on ground. Figure 11 shows the light attenuation measured in two different periods compared to the on ground one. The thermal environment in space is severe: Sun light as well as the position of the Figure 11. Attenuation length measured in two different data taking periods (June and September 2011) compared to the test beam one. solar panels onboard the ISS can affect the thermal configuration of the instrument producing temperature changes of several degrees. A dependence between the PMT gain and temperature was observed in flight data. The gain is anti-correlated with temperature and change 1% for 4 degrees (figure refmiptemp). An offline correction has been developed and implemented. 5.2. Energy scale Energy scale has been checked using MIP peak as well as the ratio between the reconstructed energy and the pulse measured by the tracker. Figure 13 shows that energy scale is stable at 1%. 6. Proton rejection As mentioned before, high granularity of calorimeter provides a good 3D reconstruction of the shower development. It allows the identification of electromagnetic particles with respect of protons using the different shapes of showers. Several approaches have been studied and developed to achieve the necessary separation between electrons and protons: cut based methods and multivariate analysis. The best method for ECAL has been a Boosted Decision Tree (BDT). To avoid any bias the training samples (background and signal) were selected from ISS data using the TRD and the tracker. Figure 14 shows the distribution of the BDT for electrons (and positrons) and hadrons. Adding the match between the reconstructed energy and the pulse measured by the tracker, we obtained a proton rejection more than 10 4 until 300 GeV and still 10 3 at 1 TeV (figure 15). 9

Figure 12. Up: MIP Peak as function of the time. Down: Temperature as function of the time in same period of the above picture. Figure 13. The energy linearity is stable at 1%. 7. Photon study The material before ECAL is only 0.6 X 0 so we expected 60% of photons interact directly in the calorimeter. Applying the selection cuts summarized in table 1 to the ECAL standalone trigger data we selected a photon sample. Backtracking electromagnetic shower axis and correcting for exposition time we obtained a picture of photon sky in which we could recognize known photon sources (figure 16). The two black holes in figure 16 are blind regions due to the ISS orbits. Reversing the procedure we used know positions of photon sources to measure the angular resolution of ECAL obtaining expected values. 8. Conclusions The AMS-02 electromagnetic calorimeter design has been described, as well as its performance with Test Beam and flight data. After 3 years of data taking, ECAL is performing according to expectations. Energy resolution and electromagnetic shower identification already achieved 10

Figure 14. BDT variable distribution for electrons and positrons (blue distribution), as well as for protons (red distribution) for all energies. Figure 15. Proton rejection as function of proton momentum. ECAL BDT plus a 0.75 cut on ratio are applied. E P Detector TRD Tracker TOF ACC RICH ECAL Cut Table 1. Selection cuts to obtain photon sample. No tracks reconstructed No tracks reconstructed, no hits correlated with shower axis Limits on hits numbers. Time difference between Upper and Lower TOF Limits on the number of hits Limits on the number of hits Shower axis within ECAL fiducial volume Extrapolation of shower inside active upper TOF area Electromagnetic shower shape 11

Figure 16. Photon sky obtained using ECAL reconstructed photons. Inside the red circles there are known photon sources (Vela, Galactic Center, etc...). Black holes are blind regions due to the ISS orbits. relevant scientific results on electron/positron measurement [7]. Otherwise angular and energy resolution allow to search for substructures in the diffused gamma flux from center of galaxy or other possible dark matter candidate sources. 9. References [1] Th. Kirn, Nucl. Instrum. Methods Phys. Res., Sect. A 706, 43 (2013); Ph. Doetinchem et al., Nucl. Instrum. Methods Phys. Res., Sect. A 558, 526 (2006); F. Hauler et al., IEEE Trans. Nucl. Sci. 51, 1365 (2004). [2] A. Basili, V. Bindi, D. Casadei, G. Castellini, A. Contin,A. Kounine, M. Lolli, F. Palmonari, and L. Quadrani,Nucl. Instrum. Methods Phys. Res., Sect. A 707, 99 (2013); V. Bindi et al., Nucl. Instrum. Methods Phys. Res., Sect. A 623, 968 (2010). [3] B. Alpat et al., Nucl. Instrum. Methods Phys. Res., Sect. A 613, 207 (2010);K. Luebelsmeyer et al., Nucl. Instrum. Methods Phys. Res., Sect. A 654, 639 (2011). [4] Ph. von Doetinchem, W. Karpinski, Th. Kirn, K. Lu belsmeyer, St. Schael, and M. Wlochal, Nucl. Phys. B, Proc. Suppl. 197, 15 (2009). [5] M. Aguilar-Benitez et al., Nucl. Instrum. Methods Phys. Res., Sect. A 614, 237 (2010); M. Aguilar-Benitez et al., in Proceedings of the 30th ICRC, 2007 (Universidad Nacional Auto noma de Me xico, Mexico City, 2008), Vol. 2, p. 461; P. Aguayo et al., Nucl. Instrum. Methods Phys. Res., Sect. A 560, 291 (2006); B. Baret et al., Nucl. Instrum. Methods Phys. Res., Sect. A 525, 126 (2004); J. Casaus, Nucl. Phys. B, Proc. Suppl. 113, 147 (2002). [6] C. Adloff et al., Nucl. Instrum. Methods Phys. Res., Sect. A 714, 147-154 (2013). [7] AMS Collaboration (M. Aguilar et al.), Phys.Rev.Lett. 110 141102 (2013). 12