Continuous Evaluation of Odour Concentration at a Plant Emission by Electronic Nose

Similar documents
MSWI Flue Gas Two-Stage Dry Treatment: Modeling and Simulation

Development of on-line and Field Dual TD-GC-FID/MS for Automatic and Continuous Volatile Organic Compounds (VOCs) Ambient Air and Odour Monitoring

A New Batch Extractive Distillation Operational Policy for Methanol Recovery

Determining Separation Distances to Avoid Odour Annoyance With Two Models for a Site in Complex Terrain

ANN TECHNIQUE FOR ELECTRONIC NOSE BASED ON SMART SENSORS ARRAY

Investigation of Performance of Different Sorbents in a Twostage Flue Gas Dry Treatment of a MSWI

Biogas Clean-up and Upgrading by Adsorption on Commercial Molecular Sieves

Use of TG-DSC-MS and Gas Analyzer Data to Investigate the Reaction of CO 2 and SO 2 with Ca(OH) 2 at Low Temperature

Falling Film Evaporator: Drying of Ionic Liquids with Low Thermal Stress

An Advanced Hand Held Electronic Nose for Ambient Air Applications

Isopropyl Alcohol Vapour Removal from Diluted Gaseous Stream by Adsorption: Experimental Results and Dynamic Model

Drum Burst due to Runaway Reaction and the Limits of MOC

Assessment of the Performance of a Fully Electric Vehicle Subsystem in Presence of a Prognostic and Health Monitoring System

PUGET SOUND CLEAN AIR AGENCY

Compression and Expansion at the Right Pinch Temperature

Implementation of the Dynamic Modeling for Development of Chemical Processes

Achim J. Lilienthal Erik Schaffernicht Achim J. Lilienthal. AASS, Örebro University

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

Three-dimensional Modelling of Reactive Solutes Transport in Porous Media

Indirect Series of Falling Film Distillation Column to Process Synthetic Naphtha

Carbon dioxide removal processes by alkanolamines in aqueous organic solvents Hamborg, Espen Steinseth

An Alternative Way to Determine the Self-Accelerating Decomposition Temperature by Using the Adiabatic Heat- Pressure Accumulation Test

Comparison of the Heat Transfer Efficiency of Nanofluids

Use of Stripping or Rectifying Trays for a Distributed Control Strategy in Distillation Column

Synthesis and Application of Green Surfactant from Oil Palm Empty Fruit Bunches s Lignin for Enhanced Oil Recovery Studies

air protection technology

VOC TEST REPORT M1. 23 October Regulation or protocol Conclusion Version of regulation or protocol

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Battery Pack Temperature Estimation Model for EVs and Its Semi-transient Case Study

Characterising Volatile Organic Compounds from Sewer Emissions by Thermal Desorption coupled with Gas- Chromatography-Mass Spectrometry

Solid-Fluid Equilibrium for the System Activated Carbon and Aqueous Solutions of Phenol under Supercritical Water Conditions

Test Report- VOC emission regulations in Europe

Questions, Myths and Misconceptions about Using Photoionization Detectors

Soft Sensor Modelling based on Just-in-Time Learning and Bagging-PLS for Fermentation Processes

Numerical Analysis of Flow Dynamics of Cyclone Separator Used for Circulating Fluidized Bed Boiler

The Failure-tree Analysis Based on Imprecise Probability and its Application on Tunnel Project

A User-Defined Pervaporation Unit Operation in AspenPlus on the Basis of Experimental Results from Three Different Organophilic Membranes

Odor Detection and Analysis using GC/SAW znose

Effect of the Temperature in the Decanter on Total Annual Cost of the Separation Process for Binary Heterogeneous Azeotropic Mixture

Test Report. Glava AS. Emission test of Ecophon Venus according to M1 classification. October / November Smedeskovvej 38, DK-8464 Galten

Oxidation of C 3 and n-c 4 aldehydes at low temperatures

Wagerup Refinery: Odour Strength vs Concentration of VOC, Aldehydes & Ketones from Various Operating Units

Oppau 1921: Old Facts Revisited

ANA - Online Measurements of Dioxins

Advanced technique to reduce emissions of fine particulate matter using ultrasounds

Separation Performance of Polymer Membranes for Organic Solvent Mixtures

Experimental Study on Durability and Mechanical Properties of Basalt Fiber Reinforced Concrete under Sodium Sulfate Erosion

Influence Of The Substrates On Water-based Paints Emissions Fabio Abbà,1*, Mikaela Decio 2, Tiziano Cerulli 2 and Roberto Leoni 2

Fact sheet on Intermediates under REACH

Pool Evaporation at Higher Vapour Pressures

Evaluation of the Dynamics of a Distillation Column with Two Liquid Phases

HETEROGENEOUS CONDENSATION FOR SUBMICRONIC PARTICLE ABATEMENT: EXPERIMENTS AND MODELLING

VOC TEST REPORT CDPH

Supercritical Antisolvent Precipitation of Sotalol Hydrochloride: Influence of Solvent and of Apparatus Design

Application of low temperature plasma environment for reduction of selected carcinogenic compounds in asphalt industry off-gases

Fluctuation-Enhanced Sensing with Commercial Gas Sensors

Comparison of Conventional and Middle Vessel Batch Reactive Distillation Column: Application to Hydrolysis of Methyl Lactate to Lactic Acid

Modeling Vapor Liquid Equilibrium of Binary and Ternary Systems of CO 2 + Hydrocarbons at High-Pressure Conditions

Exercise 4-4. Titration of a Buffer Solution EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Buffer solutions

Real Time On-Site Odor and VOC Emission Measurements Using a znose

TEST REPORT Formaldehyde Reduction

VOC TEST REPORT M1. 16 August Regulation or protocol Conclusion Version of regulation or protocol

Condensation and Evaporation Characteristics of Flows Inside Three Dimensional Vipertex Enhanced Heat Transfer Tubes

Fragrances Sampling and Analysis

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

inputs. The velocity form is used in the digital implementation to avoid wind-up [7]. The unified LQR scheme has been developed due to several reasons

VOC TEST REPORT M1. 6 April Regulation or protocol Conclusion Version of regulation or protocol

Extrel is widely respected for the quality of mass spectrometer systems that are

Sampling. Information is helpful in implementing control measures for reducing pollutant concentration to acceptable levels

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Triple Column Pressure-Swing Distillation for Ternary Mixture of Methyl Ethyl Ketone /Isopropanol /Ethanol

SUPERCRITICAL CARBON DIOXIDE DESORPTION OF XYLENE FROM ZEOLITE

Atomization Behavior as a Function of the Viscosity in a Rotary Disk Spray Dryer

COPLEY S C I E N T I F I C. A multi-function aerosol system with aerosol generation, classification and monitoring capabilities for:

AASS, Örebro University

M1 Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04

Figure 1 Enlargement of Powdered Activated Carbon by microscope.

PrOlor: a Modelling Approach for Environmental Odor Forecast

Numerical Study on Heat Transfer Enhancement in a Rectangular Duct with V-Shaped Ribs

VOC EMISSION TEST REPORT ISO 16000

COMPLIANCE EMISSIONS TEST California Dept. of Public Health Standard Method Version 1.1 and FloorScore Flooring Evaluation

VOC TEST REPORT AgBB

Tar analysis by Solid Phase Adsorption (SPA) associated with Thermal Desorption (TD) and Gas Chromatography (GC) analysis

ESTIMATION OF UNCERTAINTY IN THE DETERMINATION OF NITROGEN OXIDES EMISSIONS

Working with Hazardous Chemicals

The Relationship between the Explosion Indices of Dispersed Dust and Particle Surface Area and the Heat of Combustion

Indoor Testing of Solar Systems: A Solar Simulator for Multidisciplinary Research on Solar Technologies

THERMOCHEMICAL INSTABILITY OF HIGHLY DILUTED METHANE MILD COMBUSTION

Development of a Simple Cataluminescence Sensor System for Detecting and Discriminating Volatile Organic Compounds at Different Concentrations

TRITIUM RECOVERY FROM WASTE USING A PALLADIUM MEMBRANE REACTOR

Technological Interventions for Managing Chemical Waste

Property Ozone Vs Oxygen. Molecular Formula: O3 O2. Molecular Mass: Color: light blue Colourless

DRAIN TRACING DYE RED E123

Differential Mobility Particle Sizer (Aerosol measurements)

centro tecnológico Development of reference materials: a case study on packaging material as a source of taints in foods

Oxidation Power of Various Reactive Species (Chlorine=1) Oxidation Power of Various Reactive Species (Chlorine=1)

Hydraulic and Mass Transfer Performances of a Commercial Hybrid Packing: The RSP200X - Key Modelling Parameters for Gas Treatment Applications

Test Report ROMA USA LLC. Product Emissions of Furniture in accordance with. Cradle to Cradle section 5.8 ECODOMUS SATIN BASE TR.

Maintenance Optimisation of Optronic Equipment

Kinetic modelling of Biofuels: Pyrolysis and Auto-Ignition of Aldehydes

Transcription:

133 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 40, 2014 Guest Editor: Renato Del Rosso Copyright 2014, AIDIC Servizi S.r.l., ISBN 978-88-95608-31-0; ISSN 2283-9216 The Italian Association of Chemical Engineering www.aidic.it/cet DOI: 10.3303/CET1440023 Continuous Evaluation of Odour Concentration at a Plant Emission by Electronic Nose Lidia Eusebio a *, Selena Sironi a, Laura Capelli a, Massimilano Il Grande b, Matteo Della Torre c a Politecnico di Milano, Department of Chemistry, Materials and Chemical Engineering Giulio Natta, Piazza Leonardo da Vinci 32, 20133 Milano, Italy b Progress S.r.l., via A. Porpora 147, 20131, Milano, Italy c Sacmi s.c., via Provinciale Selice 17/a, 40026 Imola, Italy * lidiagiuseppina.eusebio@polimi.it The development of an electronic nose for the continuous monitoring of odour emissions from an industrial plant would represent an important advantage in the field of environmental odour emissions control. For instance, it would allow to characterize odour emissions over time and use these data as real time input (data) for dispersion modelling purposes. This study presents the first results of our research for the development of an electronic nose designed specifically for emission monitoring. The electronic nose EOS 507 was developed in collaboration with Sacmi s.c. and Progress S.r.l. The emission chosen to test the electronic nose performances was a chimney for the emissions of the fumes produced by a plant for the disposal and treatment of hospital waste. A preliminary study was conducted in order to evaluate the instrument capability to quantify the odour concentration of pure compounds as well as of mixtures emitted by the monitored plant. An accurate instrument training was carried out in order to account for both the different operation phases of the plant and the variability of the conferred waste. The monitoring in the field involved the periodical collection of samples at the monitored emissions and their analysis by dynamic olfactometry, in order to verify the correctness of the electronic nose estimations. The first results obtained seem to highlight that the electronic nose, if opportunely trained, is capable of estimating the odour concentration of the emission at a satisfying level of accuracy. 1. Introduction The presence of odour in ambient air is nowadays recognized as an environmental stressor that negatively affects the quality of life (Blanes-Vidal et al., 2012). In order to evaluate odour exposure at receptors, several methods can be applied (Capelli et al, 2013). Different regulations provide to use dispersion modelling to simulate how odour disperses into the atmosphere, and consequently to calculate hourly ground odour concentration values in the simulation space-time domain (Cusano et al., 2010). Given that a detailed characterisation of emissions over time would require frequently repeated olfactometric tests, thus resulting in a very expensive (in terms of money and time) approach, emission data employed as model inputs are usually represented by averaged odour emission rate values. This approach may provide a good description of the average odour impact, but doesn t take account of fluctuations that are typical of some emission typologies (Isaac-Ho Tin Noe et al., 2010). This study discusses the possibility of installing an electronic nose directly at an emission, in order to measure odour concentration continuously and therefore to obtain data that could be possibly used as real-time inputs for dispersion models. This application requires the development of a specific instrument, as well as a specific training. An EOS 507 electronic nose, developed in collaboration with Sacmi s.c. and Progress S.r.l., was used to evaluate the Please cite this article as: Eusebio L., Sironi S., Capelli L., Il Grande M., Della Torre M., 2014, Continuous evaluation of odour concentration at a plant emission by electronic nose, Chemical Engineering Transactions, 40, 133-138 DOI: 10.3303/CET1440023

134 possibility to monitor the odour concentration at the emission of a plant for hospital waste treatment. Actually, the electronic nose was set up on the exhaust gas line - going to stack of the sterilization process operating at 120 C. Laboratory tests were conducted to evaluate the electronic nose capability of quantifying odour concentration: artificial samples created starting from pure compounds and mixtures of compounds, usually detected in the emission of the plant, were tested at different concentrations, as well as real samples collected directly from the odour source of the plant. 2. Materials and Methods 2.1 The EOS 507 electronic nose The electronic nose used for this work is an EOS 507 (Dentoni et al., 2012). The instrument has two inlets for air: one of them is connected with the system for the neutral air realization; the other one is connected with an electronic valve that regulates the sample flow that is sent to the sensor chamber, which contains 6 MOS sensors, specifically selected for this application. Moreover, the electronic nose is equipped with a temperature and humidity sensor. For the regulation of the sample humidity, the electronic nose regulates neutral air humidity to a certain value RHwk that the software calculates from the external humidity value (RHext). With the EOS 507, only one feature is calculated from the response of each sensor, defined as E.U. (EOS Unit). All measures are normalized using an internal standard consisting of n-butanol at a known and constant concentration and, as a consequence of this normalization, sensors responses in terms of E.U. should increase linearly with the concentration of the analysed sample. The classification and quantification algorithm is a modified KNN-algorithm. The electronic nose is trained with artificial and real samples collected on the source to be monitored, diluted as to obtain samples at different concentrations. For sample recognition, the system compares the distance, in the 6-dimensional response space (6 sensors giving each 1 E.U. value), of the point relevant to the unknown measure to be classified and the broken lines between two neighbouring points belonging to the same olfactory class. The unknown measure is then classified as belonging to the olfactory class for which the minimum distance is measured. The odour concentration of the analysed sample is then calculated based on the odour concentrations of the points at the extremities of the segment, by evaluating the relative distance between the two points at known concentration and the position of the projection of the point representing the unknown measure. 2.2 Considered emission The emission considered in this study is a chimney of a hospital waste treatment plant. More in detail, the chimney emits the air sucked from the grinder where the medical waste is first treated, as well as all the vents coming from the sterilization process. The plant operates with cycles and each cycle can be considered as composed by different phases. After collection, the medical waste is grinded and sent to a batch sterilizer. When the waste loading in the sterilizer is completed, the air inside the sterilizer is sucked by means of a pump and emitted through the chimney. After that, the sterilization process starts with the injection of steam. After 15-20 minutes, the sterilizer is vented, and this vent is emitted through the chimney, as well. The emission from the chimney is therefore variable. Based on the above described process, three different emissions typologies can identified: the air sucked from the grinder, the vent of the air sucked from the sterilization system before the steam injection and the vent after the sterilization process. Gaseous samples were collected at the emission during these three different phases, and then tested by dynamic olfactometry in order to evaluate their odour concentration. Moreover, chemical analyses were carried out in order to determine the chemical composition of the emission. 2.3 Tests with pure compounds Pure compounds to be used for laboratory tests were chosen among compounds detected in the emission. More in detail, starting from chemical analysis results, and considering the odour threshold of each compound, the theoretical odour concentration related to each single compound in the emission was estimated (Table 1). Laboratory tests were conducted using those chemical compounds having the major theoretical odour concentration in the emission: ethanol and ammonia.

135 Table 1. Chemical compounds at the emission with odour threshold Compound Amount of pollutant [mg/nm 3 ] OT [ppm/ou E /m 3 ] Calculated Odour Concentration n-pentane 1.20 135.47 0.01 2-propanol 10.00 18.10 0.83 Cyclohexane 1.20 50.08 0.02 Ethanol 31.00 0.04 437.14 Acetone 0.56 0.39 0.56 Hexane 2.10 26.40 0.02 Chloridric acid 0.73 4.36 0.10 Acetaldehyde 0.68 0.01 70.40 Formaldehyde 0.49 0.75 0.49 Butyraldehyde 0.02 0.00 1.23 Benzaldehyde 0.06 0.05 0.27 Ammonia 1.31 0.01 172.61 Gaseous samples of each pure compound were analysed with the electronic nose at different concentrations in order to train the electronic nose to estimate odour concentration. After the training phase, gaseous samples were analysed with the EOS 507, which estimated their odour concentration. Tests were performed using gaseous samples containing ammonia and ethanol separately, as well as mixtures of the two compounds. The odour concentration of analysed samples was in the range between 20 and 500 ou E /m 3. 2.4 Tests with real samples Different samples were collected at the emission during the 3 different phases of the process. All samples were analysed by dynamic olfactometry to determine their odour concentration. The electronic nose was trained with all real samples at different odour concentrations, between 10 and 100% of the measured odour concentration. The capability of the electronic nose to estimate the odour concentration of real samples was tested. For this purpose, different samples having different odour concentrations were obtained from collected real samples. Those samples were then analysed with EOS 507 and the estimated odour concentration registered. During the quantification process the following procedure was used: First for each odour typology, only the corresponding training dataset was considered (e.g. ethanol testing used Ethanol training only) Then, all the training datasets were involved for odour quantification (e.g. ethanol testing used training for each substance). Finally, the estimated and real odour concentrations were compared, to evaluate the performance of the instrument according to the data sets provided (i.e. only one dataset vs. all). 2.5 Tests at the chimney The electronic nose was installed at the chimney of a hospital waste treatment plant. A complete of the train 3 different phases of the waste treatment was used. In order to compare the ability of the electronic nose of estimating the odour concentration of the emission at a satisfying level of accuracy, different sample were collected at the emission during the 3 different phases of the process. All samples were analysed by dynamic olfactometry to determine their odour concentration. The estimated and real odour concentrations were compared to evaluate the performances of the instrument when it work on site. The quantification was performed using a complete training. 3. Results and discussion 3.1 Tests with pure compounds results Electronic nose responses to different odour concentrations of the different considered pure compounds were evaluated in order to verify the linearity between electronic nose responses (E.U.) and odour concentration. As an example, the electronic nose responses to different odour concentrations of a gaseous sample containing ethanol are reported in Figure 1.

136 E.U. 1800 1600 1400 1200 1000 800 600 400 200 0 Sensor 1 Sensor 2 Sensor 3 Sensor 4 Sensor 5 Sensor 6 0 29 58 87 116 145 174 203 232 261 290 ou E /m 3 Figure 1. E.U. registered for different odour concentrations of the ethanol sample Some of the results of the odour concentration estimation performed by the electronic nose using the pure compounds are reported in Table 2. Table 2. Real and estimated odour concentrations relevant to the tests with pure compounds Tested Compound Real concentration Estimated concentration Error [%] Ethanol 145 150 3 Ethanol 145 149 3 Ethanol 290 255 12 Ethanol 290 255 12 Ethanol 290 283 2 Ethanol 290 275 5 Ethanol 580 593 2 Ammonia 82 99 21 Ammonia 164 141 14 Ammonia 246 208 15 Ammonia 328 301 8 Ammonia 411 417 1 Ammonia + Ethanol 62 70 13 Ammonia + Ethanol 125 118 6 Ammonia + Ethanol 187 194 4 Ammonia + Ethanol 249 260 4 Ammonia + Ethanol 312 306 2 Ammonia + Ethanol 124 120 3 Ammonia + Ethanol 187 193 3 Ammonia + Ethanol 312 314 1 In the table, the real and the estimated odour concentrations are listed; the error (per cent) of the concentration estimation is reported, as well. Odour concentrations estimated by the electronic nose are comparable with the real concentration evaluated by means of dynamic olfactometry, or obtained by diluting gaseous samples having a known odour concentration. The per cent error is comprised between 1 and 20 %, and the error decreases when the odour concentration increases.

3.2 Tests with real samples results Table 3 reports the results obtained with the real samples. More in detail, column 2 of Table 3 reports the real odour concentration detected by means of olfactometric analysis, column 3 reports the odour concentration estimated using only the training data set of the same emission phase (single training dataset) and column 5 the odour concentration estimated using the complete training dataset. The electronic nose is able to estimate the odour concentration of real samples with an error between 2 and 37%. The quantification system guarantees the same performances both using the single training and the complete training. In general, it can be observed that the odour concentrations estimated by the electronic nose are almost always lower than the odour concentration measured by dynamic olfactometry. This may be due to the losses through the sampling bags that may occur during the time interval between the two analyses (Hansen et al., 2011). These leakages could concur in a non-negligible way to the error of the concentration measurements for an undefined percentage. 137 Table 3. Real and estimated odour concentrations relevant to the tests with real samples Estimated Estimated Real Emission concentration Error concentration Error concentration typology [ou E /m 3 (single training) [%] (complete training) [%] ] Grinding 900 600 33 599 33 Grinding 1200 843 30 839 30 Grinding 1500 1088 27 1081 28 Pre-sterilization 80 58 28 58 28 Pre-sterilization 160 101 37 101 37 Pre-sterilization 240 154 36 153 36 Pre-sterilization 320 268 16 271 15 Pre-sterilization 400 321 20 321 20 Post-sterilization 620 619 0 650 5 Post-sterilization 1240 995 20 947 24 Post-sterilization 1860 1823 2 1700 9 Post-sterilization 2480 2716 10 2656 7 Post-sterilization 3100 3921 26 3049 2 3.3 Tests at the chimney results Table 2 reports the results obtained at the chimney by the electronic nose and the dynamic olfactometry of the real samples. More in detail, the real odour concentration measured by dynamic olfactometry, the odour concentration estimated using the complete training dataset and the percentage error are reported. In general, it can be observed that the odour concentrations estimated by the electronic nose at the chimney are almost always lower than the odour concentration measured by means of dynamic olfactometry for the emission from Pre-sterilization and Post-sterilization operations. Conversely, the grinding phase presents odour concentrations estimated with the electronic nose at the chimney higher than those measured through dynamic olfactometry. The electronic nose is able to estimate the odour concentration of real samples on site with an error between 10 and 64% with the only exception of one measure of the grinding phase where the error is equal to 86%. This high value may be due to a combination of two effects: 1. the high response of the sensor to some pollutant present in the grinding emission, 2. the fact that the nose does not have time to fully regenerate the sensors between one measure and the following one. On the contrary, during training a long cleaning time between two sessions was scheduled for the nose. Moreover, during the tests with the real samples the sensors were cleaned before every recognition run. Since for a plant working continuously it s not possible to perform a full clean, probably one solution could be diluting the emission at the inlet of the nose in order to contain the sensor response avoiding excessive feedbacks.

138 Table 4. Real and estimated odour concentrations relevant to the tests estimated on site by the electronic nose and with real samples measured by dynamic olfactometry Estimated Emission typology Real concentration Error concentration (complete [ou E /m 3 [%] ] training) Grinding 10000 25000 60 Grinding 10000 28000 64 Grinding 8200 59000 86 Pre-sterilization 23000 21760 6 Pre-sterilization 15000 13600 10 Post-sterilization 11000 9000 22 Post-sterilization 12000 9417 27 4. Conclusion Laboratory tests show that the EOS 507 is able to quantify the odour concentration of samples of pure compounds and of real samples. The error obtained with pure compounds is comprised between 1 and 20%. The capability of the system to estimate the odour concentration turned out not to be influenced by the use of mixtures of different pure compounds in air instead of gaseous samples of pure compounds in air. Tests performed with real samples demonstrate that the system is capable to estimate the odour concentration with the same accuracy using only a training dataset obtained with samples belonging to the same olfactory class as the sample to be quantified, as well as using a complete dataset, which contains data relevant to different olfactory classes. This of course is an important information, meaning that the use of one single complete dataset will be sufficient in order to quantify the odour concentration of the monitored emission during all the phases within a satisfying level. The error relevant to the odour concentration estimation of real samples is comprised between 2 and 37%. Laboratory tests proved the electronic nose EOS 507 to be able to quantify odour concentration with a error below 40%. Tests performed on site demonstrate that the system is capable to estimate the odour concentration. The error relevant to the odour concentration estimation of real samples is comprised between 10 and 64%. Future studies will be carried out in order to verify the electronic nose performances directly in different applications. Moreover, the instrument will be tested with different samples, collected on other odour sources, in order to evaluate its performances with different emissions and different plants. References Blanes-Vidal V., Nadimi E.S., Ellermann T., Andersen H.V., Loftrom P., 2012, Perceived annoyance from environmental odors and association with atmospheric ammonia levels in non-urban residential communities: a cross-sectional study, Environ. Health 11, 27-37. Capelli L., Sironi S., Del Rosso R., Guillot J.-M., 2013, Measuring odours in the environment vs. dispersion modelling: A review, Atmos. Environ. 79, 731-743. Cusano G., Licotti C., Sironi S., Capelli L., Rossi A.N., Il Grande M., 2010, Odour regulation in Italy: the regional guidelines on odour emissions in Lombardia, Chem. Eng. Tans. 23, 19-24. Dentoni L., Capelli L., Sironi S, Del Rosso R., Zanetti S., Della Torre M., 2012, Development of an electronic nose for environmental odour monitoring, Sensors, 12, 14363-14381. Hansen M. J., Adamsen A. P. S., Feilberg A., Jonassen K. E. N. 2011, Stability of Odorants from Pig Production in Sampling Bags for Olfactometry, J. Environ. Qual. 40, 1096-102. Isaac-Ho Tin Noe I., Siino F., Bara C., Urvoy Y., Haaser C., Tripathi A., Ait Hamou L., Mailliard T., 2010, Tool for predicting and monitoring the impact of wastewater treatment plants on odour, Chem. Eng. Tans. 23, 267-272.