LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

Similar documents
LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Application Note. Abstract. Authors. Environmental

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Application Note. Abstract. Authors. Food Safety and Environmental

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Determination of Alkaloids in Goldenseal Using Agilent Bond Elut Plexa Solid Phase Extraction Sorbent for Cleanup and HPLC-DAD Analysis

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Determination of Hormones in Serum by LC/MS/MS Using Agilent Bond Elut Plexa SPE

Solid Phase Extraction Method Development Tips and Tricks

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes Application

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction

Agilent ESI and APCI sources: for polar to non-polar compounds

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Detection of Trace Level Pharmaceuticals in Drinking Water by Online SPE Enrichment with the Agilent 1200 Infinity Series Online-SPE Solution

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Development of analytical methods for Catecholamines, Metanephrines and related metabolites in urine and plasma matrices

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

Determination of 24 PAHs in Drinking Water

[ Care and Use Manual ]

Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer

The Quantitation and Identification of Coccidiostats in Food by LC-MS/MS using the AB SCIEX 4000 Q TRAP System

Taking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

A New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS

Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Rapid, sensitive, and easy UHPLC-MS/MS analysis of fungicides in fruit juices with QuEChERS

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Fully automated QuEChERS clean-up and LC/MS-QQQ analysis of pesticides in fruits and vegetables.

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Accurate Mass Analysis of Hydraulic Fracturing Waters

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Modernizing the USP Monograph for Acetaminophen

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Agilent Standard Operating Procedure

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 120 Columns

Figure 1. The supported liquid extraction process using the ISOLUTE SLE plate (single well shown)

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

Simultaneous Determination of 26 Mycotoxins in Sesame Butter Using Modified QuEChERS Coupled with UHPLC-ESI/Triple Quadrupole Mass Spectrometry

Transcription:

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120 Application Note Food Testing & Agriculture Author Irina Dioumaeva Agilent Technologies, Inc. Abstract This application note describes the analysis of fungicide residues in apple juice using easy sample preparation coupled with LC/MS/MS detection. Developed for 3 most important systemic fungicides carbendazim, thiabendazole, and imazalil with its metabolite, this method can be easily expanded to include a broader range of pesticides. A simple and rapid extraction procedure provides clean extracts that without any preconcentration allow for detection of analytes at concentrations below 2 ppb. Quantification was performed using triphenyl phosphate as an internal standard. Excellent accuracy (% recovery) and precision (% CV) data were obtained for 3 concentration levels: 10, 50, and 250 ppb of each analyte. Introduction Fungicides are a group of pesticides used to inhibit fungal growth. Since fungicide residues in food present serious health concerns, they are regulated in Europe, United States and many other countries. Fungicides carbendazim and thiabendazole belong to the benzimidazole class, and imazalil to the imidazole class of pesticides. Imazalil is easily metabolized to alpha-(2,4-dichlorophenyl)-1h-imidazole-1-ethanol, and the sum of the parent compound and the metabolite is regulated in the United States.

Benzimidazole fungicides are widely used in agriculture both for plant disease control and postharvest treatment of fruit. Carbendazim (MBC) is not registered for use in the US, but it is legally used in many other countries exporting their fruit and juice to the US. Also, carbendazim is a metabolite/ degradate of the fungicide thiophanate-methyl (TM) which is registered for use on a number of crops and turf in the US, thus creating a potential for human exposure to MBC residues. Thiabendazole, as well as imazalil, is mostly used for postharvest treatment of fruit, including apples, for storage and transportation, and both compounds are registered for use in the US. Experimental Analytes Carbendazim C 9 H 9 N 3 O 2 m.w. 191.19 pka 4.5 LogP 1.5 Thiabendazole C 10 H 7 N 3 S m.w. 201.25 pka 4.7 LogP 2.4 The simple extraction procedure described here offers reproducible high recoveries of analytes of interest due to the advanced features of Agilent Bond Elut Plexa a polymeric sorbent designed for improved analytical performance and ease-of-use. Along with superior retention of a broad range of analytes, Bond Elut Plexa provides fast and reproducible flow due to the narrow particle size distribution with no fines to cause blockages. Cleanliness of Bond Elut Plexa extracts results in low ion suppression, ensures extended HPLC column life and protects mass spectrometers from contamination. The superficially porous Agilent Poroshell 120 EC-C18 column with 2.7 µm particles ensures similar efficiency to sub-2 µm UHPLC columns but with about 40% less back pressure. During analysis, the actual pressure in the LC system does not exceed 400 bar. Enhanced sensitivity of an Agilent 6460 Triple Quadrupole LC/MS system with the AJST electrospray source provides excellent detection of all four analytes of interest at 2 ppb. Because it is considerably below any existing testing requirements, our extraction method can be used with older and less sensitive models of mass spectrometers, such as the Agilent 6410 Triple Quadrupole LC/MS System. Users of MS detectors less sensitive than an Agilent 6460 Triple Quadrupole LC/MS System could also consider preconcentration of their samples at a reconstitution step of the extraction procedure. A previous method of MBC and thiabendazole analysis in apple juice from Agilent [1] used Agilent Bond Elut SCX SPE cartridges, an Agilent ZORBAX Eclipse Plus C18, 3.5 µm column and an Agilent 1200 Series LC system with variable length control detector (VWD). Imazalil C 14 H 14 Cl 2 N 2 O m.w. 297.18 pka 6.5 LogP 3.8 P Triphenyl phosphate C 18 H 15 O 4 P m.w. 326.28 LogP 4.7 CH 2 Figure 1. Analyte structures and properties. Imazalil metabolite C 11 H 10 Cl 2 N 2 O m.w. 257.12 LogP 2.6 Pesticide standards were purchased from Sigma-Aldrich (St. Louis, MO, USA). An internal standard (triphenyl phosphate) was from Agilent Technologies (Wilmington, DE, USA). Original stock solutions (0.25 mg/ml for carbendazim and 1 mg/ml for the other 3 analytes and internal standard) were prepared in methanol and stored at 20 C. 2

Materials and instrumentation SPE: Agilent Bond Elut Plexa cartridges 30 mg, 3 ml (part number 12109303) Agilent vacuum manifold VacElut 20 (part number 12234100) Agilent stopcock valves (part number 12234520) Agilent silanized autosampler vials, 2 ml (part number 5183-2072) Agilent screw caps for AS vials (part number 5182-0717) LC: Agilent Poroshell 120 EC-C18, 2.1 x 50 mm, 2.7 µm column (part number 699775-902) MS: Agilent 1260 Infinity LC system (G1379B microdegasser, 1312B binary pump in low delay volume configuration, G1367E autosampler, G1330B thermostat) Agilent 6460A Triple Quadrupole mass spectrometer with AJST electrospray ionization source Sample preparation Pretreatment Spike 0.5 ml of juice with TPP (internal standard) at 50 ppb; use of 12 x 75 mm glass tubes is recommended. Dilute 1:3 with HPLC grade water, vortex, and centrifuge if cloudy. Clear juice does not require centrifugation. Extraction 1. Condition Bond Elut Plexa column with 0.5 ml methanol soak, then let drip 2. Load sample/supernatants 3. Wash 1: 1 ml water 4. Wash 2: 1 ml of 30:70 methanol: water 5. Dry 5 10 min under vacuum (10 15 in Hg) 6. Elute with 1 ml 80 ethyl acetate: 20 IPA. Soak, then let eluate drip into collection vials. When dripping ceases, apply low vacuum (2 3 in Hg). 7. Evaporate under stream of nitrogen to dryness at 55 C. 8. Reconstitute in 0.5 ml initial mobile phase (10% methanol, 90% water, 0.1% formic acid). LC/MS/MS LC conditions Mobile phase A: Mobile phase B: Injection volume: 5 µl Flow rate: 0.1% formic acid in water 0.1% formic acid in methanol 0.5 ml/min Gradient Time (min) % B 0.0 10 0.5 10 2.0 50 3.0 95 75 95 7.1 10 Stop time: Post time: Max pump pressure: Needle wash: Disable overlapped injection 7.2 min 2.5 min 400 bar No automatic delay volume reduction MS conditions ES source parameters Ionization mode: Capillary voltage: Drying gas flow: Flush port 75 methanol: 25 water for 10 s Positive 2,800 V 12 L/min Drying gas temperature: 350 C Nebulizer gas: Sheath gas flow: 40 psi 12 L/min Sheath gas temperature: 300 C Nozzle voltage: 0 V 3

MS parameters Scan type: Pre-run script: Dynamic MRM SCP_MSDiverterValveToWaste(){MH_Acq_ Scripts.exe} Time segments #1: 1.5 min - diverter valve to MS Delta EMV: (+) 400 V Results and Discussion All four fungicides of interest and an internal standard (TPP) are efficiently retained by Bond Elut Plexa a polar-enhanced styrene-divinylbenzene neutral polymeric sorbent. This sorbent is the best choice for non-ionic extraction of a wide range of acidic, neutral and basic analytes. We developed a very simple extraction method where dilution of juice with water is the only pretreatment required. Centrifugation can be applied if a juice has a lot of pulp but is not needed for most apple juices. Diluted samples of apple juice easily flow by gravity at loading and washing steps, and vacuum is only needed to dry the column before elution and to maximize recovery at the end of the elution step. An increase in methanol concentration at the 2 nd wash step from 5% (generic method) to the 30% recommended here allows to significantly reduce matrix interferences. This results in enhanced sensitivity of LC/MS/MS detection for earlier eluting compounds carbendazim and thiabendazole by 30%, and for imazalil metabolite by 20%. Imazalil peak areas remain unchanged. Combination eluent (80 Ethyl acetate: 20 IPA) compared to 100% methanol only slightly improves recovery of four fungicides of interest but gives about a two-fold increase in recovery of the highly hydrophobic internal standard (TPP). A list of dynamic MRM transitions for four fungicides and internal standard is given in Table 1, showing firstly a quantifier, and secondly a qualifier transition. The Agilent Poroshell 120 EC-C18, 2.1 50 mm, 2.7 µm column provides separation of four fungicides and TPP within 5 minutes. Figure 2 shows chromatograms of quantifier transitions of four fungicides in apple juice spiked at 2 ppb, with TPP as internal standard at 50 ppb. Signal-to-noise ratio for all peaks is higher than 100:1. Obviously, a detection limit for each of the analytes will be at ppt level. Each sample run begins with diverting a first portion of flow (0 to 1.5 minutes) to waste to minimize source contamination. Table 1. Dynamic MRM transitions. Compound Name ISTD? Prec Ion MS1 Res Prod Ion MS2 Res Frag (V) CE (V) Ret Time Ret Window Polarity Carbendazim 192.1 Unit 160.1 Wide 95 15 2.2 2 Positive Carbendazim 192.1 Unit 132.1 Wide 95 35 2.2 2 Positive Thiabendazole 202 Unit 175 Wide 110 27 2.5 2 Positive Thiabendazole 202 Unit 131.1 Wide 110 35 2.5 2 Positive Imazalil metabolite 257 Unit 125 Wide 110 32 2.9 2 Positive Imazalil metabolite 257 Unit 69 Wide 110 22 2.9 2 Positive Imazalil 297.1 Unit 159 Wide 130 23 3.6 2 Positive Imazalil 297.1 Unit 69 Wide 130 22 3.6 2 Positive Triphenyl phosphate 327.1 Unit 77 Wide 170 40 4 2 Positive Triphenyl phosphate 327.1 Unit 152 Wide 170 45 4 2 Positive 4

Counts 10 4 1.75 1.50 1.25 0 0.75 0.50 0.25 +MRM (192.1 -> 160.1) Noise(PeakToPeak) = 120.94; SNR (2.19 min) = 153.0 Carbendazim 10 3 8 +MRM (202.0 -> 175.0) Noise(PeakToPeak) = 76.93; SNR (2.50 min) = 116.0 Thiabendazole Counts 6 4 2 10 4 +MRM (257.0 -> 69.0) Noise(PeakToPeak) = 96.76; SNR (2.94 min) = 110.6 Imazalil metabolite Counts 0.8 0.6 0.4 0.2 Counts 10 3 3.5 3.0 2.5 2.0 1.5 0.5 +MRM (297.1 -> 159.0) Noise(PeakToPeak) = 18.74; SNR (3.57 min) = 169.5 Imazalil Counts 10 4 6 5 4 3 2 1 +MRM (327.1 -> 77.0) Noise(PeakToPeak) = 222.61; SNR (4.01 min) = 283.7 Triphenyl phosphate Figure 2. MRM extracted ion chromatograms for four fungicides (2 ppb) and TPP (50 ppb) in apple juice extract. Agilent Poroshell 120 EC-C18, 2.1 50 mm 2.7 µm column. Noise regions are shown in bold. 5

Relative responses 10 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 0.5 0 Carbendazim - 5 levels, 5 levels used, 5 points, 5 points used, 30 QCs y = 0.112392*x R 2 = 0.99558798 0 50 100 150 200 250 300 350 400 450 500 Concentration (ng/ml) Relative responses 9 8 7 6 5 4 3 2 1 0 Imazalil- 5 levels, 5 levels used, 5 points, 5 points used, 21 QCs y = 0.018186*x R 2 = 0.99406827 0 50 100 150 200 250 300 350 400 450 500 Concentration (ng/ml) Thiabendazole- 5 levels, 5 levels used, 5 points, 5 points used, 24 QCs 10 y = 0.052808*x 2.6 R 2.4 2 = 0.99541019 2.2 2.0 1.8 1.6 1.4 1.2 0.8 0.6 0.4 0.2 0-0.2 0 50 100 150 200 250 300 350 400 450 500 Concentration (ng/ml) Relative responses Relative responses 10 2.0 1.8 1.6 1.4 1.2 0.8 0.6 0.4 0.2 0-0.2 Imazalil degradate - 5 levels, 5 levels used, 5 points, 5 points used, 30 QCs y = 0.042319*x + 0.108390 R 2 = 0.99466250 0 50 100 150 200 250 300 350 400 450 500 Concentration (ng/ml) Figure 3. Example calibration curves for four fungicides in apple juice extract. Calibration range 2.0 to 500 ppb. All fits are linear, R 2 0.994. Table 2. Method performance for fungicides in apple juice, n = 5. 10 ppb 50 ppb 250 ppb Compound name R 2 Accuracy (%) CV (%) Accuracy (%) CV (%) Accuracy (%) CV (%) Carbendazim 0.996 95.7 1.1 94.1 0.4 107.3 1.2 Thiabendazole 0.995 94.7 1.7 93.6 1 104.8 0.9 Imazalil 0.994 95.7 0.4 98.5 1.3 108 0.9 Imazalil degradate 0.995 94.1 2.1 100.2 0.8 106.7 1.4 6

Conclusions Solid phase extraction procedure coupled with LC/MS/MS detection is simple and robust, providing highly accurate and reproducible results. The properties of the Bond Elut Plexa sorbent allow expansion of this method for a multiresidue pesticide analysis. Separation of the analytes of interest is completed within 5 minutes and can be performed on most Agilent LC systems. MS source parameters developed for the Agilent 6460 Triple Quadrupole can be easily modified for use with other Agilent Triple Quadrupole LC/MS systems. Preconcentration at the reconstitution step can be applied when the extraction method is used with detectors of lower sensitivity. Bibliography 1. C. Zhai, Y. Zou, C. Ball. Determination of Benzimidazole Fungicides in Apple Juice by Bond Elut Polymer SCX Solid-Phase Extraction with High-Performance Liquid Chromatography. Application note, Agilent Technologies, Inc. Publication number 5990-3235EN (2008). 2. E. M. Thurman, I. Ferrer, M. Woodman, J. Zweigenbaum. Analysis of Post-Harvest Fungicides and Their Metabolites in Citrus Fruits and Juices by Time-of Flight and Ion Trap LC/MS. Application note, Agilent Technologies, Inc. Publication number 5989-2728EN (2005). 3. A. Zhai. Analysis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection. Application note, Agilent Technologies, Inc. Publication number 5990-8034EN (2011). 4. Pesticide MRL Database http://www.mrldatabase.com/?selectvetdrug=0 For More Information These data represent typical results. For more information on our products and services, visit our Web site at www.agilent.com/chem. 7

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 2012 Printed in the USA April 11, 2012 5991-0050EN