Nuclear Gauges and Cores HOW CAN WE GET THE BEST CONSISTENCY AND CORRELATION PERTAINING TO DENSITY?

Similar documents
OHD L-14 METHOD OF TEST FOR DETERMINING THE SPECIFIC GRAVITY AND UNIT WEIGHT OF COMPACTED BITUMINOUS MIXTURES

EVALUATION OF VACUUM DRYING FOR DETERMINATION OF BULK SPECIFIC GRAVITY OF HMA SAMPLES

CE330L Student Lab Manual Mineral Aggregate Properties

State of Nevada Department of Transportation Materials Division

SECTION AGGREGATE OR GRANULAR SUBBASE

Asphalt Mix Designer. Module 2 Physical Properties of Aggregate. Specification Year: July Release 4, July

B-1 SURFACE ELEVATION

J R. TransTech Systems T S. The World s Number 1 Supplier Of Non Nuclear Density Meters for Asphalt Pavements and Engineered Soils

COMPARISON OF TESTING MEHODS FOR DETERMINATION OF ASPHALT CONTENT FOR HIGH LOSS AGGREGATES

Haleh Azari, Ph.D. AASHTO Materials Reference Laboratory HSOM Meeting, Aug. 2008

A Method, tor Determining the Slope. or Neutron Moisture Meter Calibration Curves. James E. Douglass

WACEL AGGREGATE LABORATORY TESTING TECHNICIAN

Specific Gravity and Absorption of Aggregate by Volumetric Immersion Method (Phunque Test)

Point Level Capacitance Switch for Fly Ash Hopper Measurement

WONDERING ABOUT WEATHER

METHOD OF TEST FOR RELATIVE DENSITY AND ABSORPTION OF FINE AGGREGATE

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

Commonwealth of Pennsylvania PA Test Method No. 709 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

Surveying Prof. Bharat Lohani Department of Civil Engineering Indian Institute of Technology, Kanpur. Module - 3 Lecture - 4 Linear Measurements

Chapter 2. The Ideal Aggregate. Aggregates

Mar 1, 2018 LAB MANUAL INDEX 1. Table of Contents Laboratory Testing Methods Reducing Aggregate Field Samples to Testing Size (Ver.

Volumetric Tests. Overview

Battling Segregation Using Pave IR System

METHOD FOR MEASURING PAVEMENT LIFT THICKNESS

2ND INTERNATIONAL WARM-MIX CONFERENCE St. Louis, Missouri, USA

Hot mix asphalt longitudinal joint evaluation

Rapid moisture measurement with microwave resonance technology in infant formulas

PRECISION OF HAMBURG WHEEL-TRACK TEST (AASHTO T 324)

2012 Road School Light Weight Deflectometer (LWD)

CHAPTER 5 ESTABLISHING THEORETICAL / TARGET VALUES FOR DENSITY & MOISTURE CONTENT

Aggregates. AAPA training

Large area scintillation detector for dosimetric stand with improved light collection

Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate 1

Basic Aggregates Study Guide

ROUND ROBIN EVALUATION OF NEW TEST PROCEDURES FOR DETERMINING THE BULK SPECIFIC GRAVITY OF FINE AGGREGATE

Density Gradients in Asphalt Pavements

Unbound Pavement Applications of Excess Foundry System Sands: Subbase/Base Material

Read Hewitt Chapter 33

BULK SPECIFIC GRAVITY ROUND-ROBIN USING THE CORELOK VACUUM SEALING DEVICE

COARSE VERSUS FINE-GRADED SUPERPAVE MIXTURES: COMPARATIVE EVALUATION OF RESISTANCE TO RUTTING

Fission and Chain Reactions

D501 and D501-RS. Figure 1. Unique Automatic Emissivity Compensation System (AECS) produces accurate

Scope. Overview. Apparatus. FOP for AASHTO T 329. Sample. Procedure. Moisture Content of Asphalt Mixtures by Oven Method

EFFECTS OF TEST VARIABILITY ON MIXTURE VOLUMETRICS AND MIX DESIGN VERIFICATION

Asphalt Mix Performance Testing on Field Project on MTO Hwy 10

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

Surveying Prof. Bharat Lohani Indian Institute of Technology, Kanpur. Module 5 Lecture 1

[2]

Determination of Asphalt Content in Hot Bituminous Mixes With a Portable Nuclear Asphalt Content Gage

FDOT No: C-7984 UF No: Research Team:

CREATE A MOTION. Purpose Demonstrate your understanding of motion graphs by creating real-world motion(s) that match a graph(s) you ve been given.

2) Estimate your annual radiation dose from background radiation.

Status Update: NCHRP Project 9-48

DO NOW. energy? what you think we are going to learn about.

CEEN Laboratory 4 Aggregates for Base Layers, Portland Cement Concrete & Hot Mix Asphalt

Nano Scale Organosilane Asphalt Applications

The Superpave System Filling the gaps.

TARGET AND TOLERANCE STUDY FOR THE ANGLE OF GYRATION USED IN THE SUPERPAVE GYRATORY COMPACTOR (SGC) By

Average Atomic Mass: How are the masses on the periodic table determined?

SIEVE ANALYSIS OF AGGREGATE (Kansas Test Method KT-2)

SPECIFIC GRAVITY AND ABSORPTION OF COARSE AGGREGATE FOP FOR AASHTO T 85

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

2008 SEAUPG CONFERENCE-BIRMINGHAM, ALABAMA

The Role of Well Logging in Coal-Bed Methane Extraction

MITOCW MIT18_02SCF10Rec_61_300k

History of California Drought

Contents. 1. Evaporation

GeoShanghai 2010 International Conference Paving Materials and Pavement Analysis

Neutrinos and the Universe

Estimating Fatigue Resistance Damage Tolerance of Asphalt Binders Using the Linear Amplitude Sweep

In-Situ Evaluation and Calibration of Radioisotope Cones in Singapore Marine Clays

Estimating Damage Tolerance of Asphalt Binders Using the Linear Amplitude Sweep

Geology and Soil Mechanics Prof. P. Ghosh Department of Civil Engineering Indian Institute of Technology Kanpur Lecture - 13 Soil Compaction- C

NIDIS Intermountain West Drought Early Warning System December 18, 2018

Experiment Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

Experiment 8: DETERMINATION OF AN EQUILIBRIUM CONSTANT

Engineering Properties of Soil-Fly Ash Subgrade Mixtures

Calibration of the IXPE Instrument

PRELIMINARY GEOTECHNICAL ENGINEERING REPORT

CHM 105 & 106 MO1 UNIT THREE, LECTURE ELEVEN 1 IN OUR LAST LECTURE WE WERE LOOKING AT THE SHARING PROCESS IN CHEMICAL BONDING

This paper was presented at PACE 2007 in Dallas. It compares a traditional sling psychrometer with electronic gauges.

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. D) u = - x15 cos (x15) + C

Isotopes are different forms of the that have a. Isotopes of the same element have the but. Ions are atoms that have a. In an ion, the.

How do trees like the California redwoods and the aspens of Alberta get water and minerals from their roots to their leaves way up at the top?

New Test Results For Physical Separation Of Tritium From Noble Gases And It s Implications For Sensitivity And Accuracy In Air And Stack Monitoring

Of course the importance of these three problematics is affected by the local environmental conditions.

CALCULATIONS FOR THE MARSHALL MIX DESIGN OF BITUMINOUS MIXTURES

SPECIFIC GRAVITY AND ABSORPTION OF COARSE AGGREGATE FOP FOR AASHTO T 85

The Development of a Performance Specification for Granular Base and Subbase Material

Geotechnical Engineering I CE 341

The New Normal or Was It?

Characterization of Large Structures & Components

A Study of Radioactivity and Determination of Half-Life

Catalytic bead sensors are used primarily to detect

Why does my soil moisture sensor read negative? Improving accuracy of dielectric soil moisture sensors

PREDICTIONS OF MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT FROM SIMPLE MATERIAL PROPERTIES

Lower Susquehanna River Integrated Sediment & Nutrient Monitoring Program

learning outcomes To: know what air pressure is know that you can use a barometer to measure air pressure end product a barometer

CfE Higher Chemistry. Unit 3: Chemistry in Society. Chemical Analysis as part of quality control

Haleh Azari, Ph.D. AASHTO Materials Reference Laboratory (AMRL) AASHTO Subcommittee on Materials Meeting August 2007

Transcription:

Nuclear Gauges and Cores HOW CAN WE GET THE BEST CONSISTENCY AND CORRELATION PERTAINING TO DENSITY?

Introduction Nuclear Gauge Performance can be associated with the operator, equipment s functionality, and the programmed targets (Theoretical or Bulk Densities). Let s address the Gauge first

Major Categories that Impact Readings 1. Time vs. Precision @ 140 pcf Fast Norm Slow Time 15 sec (3400) 30 sec (4640) 1 min 4 min Range (pcf) 138.5 141.5 139.0 141.0 139.5 140.5 +/- 3 +/- 2 +/- 1

Major Categories that Impact Readings 2. Standard Counts Why do we really take them?

To Calibrate the Gauge? Yes and No Depends on your definition. Most believe that if the detector tube counts measure within limits, compared to the baseline average of the last 4 standard counts, usually everything is okay (assuming the operator hasn t had a drink before hand).

Standard Counts are really taken to Compensate for Radioactive Source Decay DC = 2000 cts DS 4000 cts =.5 = 164 pcf (Granite) 1 Year Later DC = 1500 cts DS 3000 cts =.5 = 164 pcf (Granite) Can you utilize this procedure to help Consistency? Absolutely, especially during compaction testing.

Major Categories that Impact Readings 3. Temperature We all know how temperature affects the compaction process, but what about the gauges? At 170 F and higher, this element can impact gauge electronics, which obviously may contribute to predetermined gauge/core correlation offsets. Taking numerous Standard Counts during the day will offset any temperature effects on the gauge readings.

Major Categories that Impact Readings 4. Physical Condition of the Gauge

4. Physical Condition of the Gauge

4. Physical Condition of the Gauge Impact of Asphalt Stuck on the Tip of the Probe

Programmed Targets Your targets are determined by 3 different methods: 1. Control Strip Test measure the density of the strip, and use that value as the target density for the project. 2. Compacting samples in the laboratory during mix design and during the lay-down procedure. 3. The Theoretical Maximum Density (TMD) ASTM D2041 Which is better? That s a conversation for another day. NJ utilizes the third Density specified as percent of TMD.

Programmed Targets (cont d) This type of compaction specification requires the TMD be measured routinely during construction. The TMD measured during design should not be used as a reference target for the mix being produced. This difference can be attributed to the materials changing when heated and mixed at the plant. TMD must be measured on plant produced samples.

Core Densities Failure to allow the core to dry before obtaining the dry weight can cause many issues. It should be allowed to air-dry or dry using the Core Dry method AASHTO PP-75, ASTM 7227.

Core Densities Contractors and the State can quickly dry cores and determine bulk density results in hours, not days, after core is cut (AASHTO T166 > 12 hours). In-place densities and gauge correlations determined at far greater speeds. Cores are thoroughly dried by vacuum rather than evaporating water with heat far more efficient drying process.

Core Densities This method will allow consistency between State DOT and Contractor density readings. Heating the cores in the oven at an elevated temperature is not the path to follow. If not completely dry, this factor will lead to higher density values. Cores should be saw-cut, especially with SMA mixes failure to do so can lead to possible erratic density calculations.

Full Depth Reclamation Can we obtain a legitimate Proctor Value on this type of application? Engineers have a tendency to use Dry Density calculations. This requires accurate moisture measurements from the gauges. It is prudent to use the Wet Density readings from the gauge instead of the Dry Density readings.

Food for Thought Bituminous production and paving involve extensive procedures and testing. We wonder if the cards are stacked against us, i.e. avoiding the dreaded penalty. Re-evaluation of designs, production and placement practices are necessary, but the fine line is balancing theory/research with practicality in the field.

Conclusion Density is only one aspect, but hopefully procedures, especially concerning operators and testing equipment, are consistent regardless of who is behind the wheel. The information presented today may be a refresher for some, but if it keeps the attorneys at bay, You re welcome! I m still learning!