Rely on Rxi -PAH Columns

Similar documents
PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products

Application Note. Abstract. Authors. Environmental

Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

Determination of 24 PAHs in Drinking Water

Selection of a Capillary GC Column

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

Faster Semivolatiles Analysis with a Scaled- Down Method and GC Accelerator Kit

Analysis. Priority LC GC. Zebron PAH Accurately quantitate EU and EPA PAHs in less than 28 minutes

Selection of a Capillary

Katherine K. Stenerson, Michael Ye, Michael Halpenny, Olga Shimelis, and Leonard M. Sidisky. Supelco, Div. of Sigma-Aldrich Bellefonte, PA USA

Optimizing GC Parameters for Faster Separations with Conventional Instrumentation

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column

This project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

Developing Large Volume Injection (LVI) in Split / Splitless Inlets. Philip J. Koerner Phenomenex Inc. NEMC 2014

Get Selective. By Jaap de Zeeuw

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

The Suite for Environmental GC Analysis

A Fast, Simple FET Headspace GC-FID Technique for Determining Residual Solvents in Cannabis Concentrates

Sensitive and rapid determination of polycyclic aromatic hydrocarbons in tap water

Definitive EtG/EtS LC-MS/MS Analysis:

ENVIRONMENTAL analysis

Excellent Resolution of EU-Regulated Azo Dye Aryl Amines by GC-MS on the Rxi-35Sil MS GC Column

So Many Columns! How Do I Choose? Daron Decker Chromatography Technical Specialist

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Choosing the Correct GC Column Dimensions and Stationary Phase

GCxGC Columns Your One Source for 2D Gas Chromatography

The Design of High Temperature Capillary Gas Chromatography Columns Based on Polydimethylsiloxane

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

SUPPLEMENTARY INFORMATION. Towards streamlined identification of dioxin-like compounds in

Facility: Mansfield Revision 3. Title: PAHs by SPME Page 1 of 11

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

ADVANTAGE. Also in this issue. Our expertise, experience, and enthusiasm is your Advantage.

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

The Truth About Dioxin Analysis: Using High Resolution GC-TOFMS and GCxGC-TOFMS to. Analytical Approaches

Virtually Particle-Free Rt -Silica BOND Columns

Single-Laboratory Validation of a GC-MS Method for the Determination of 27 Polycyclic Aromatic Hydrocarbons (PAHs) in Oils and Fats

Application Note GCMS-09 Evaluation of Rapid Extraction and Analysis Techniques for Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood by GC/MS/MS

Application Note # CA

The Era of Mass Surveillance

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

CERTIFICATION REPORT. Certification of the Mass Fraction of Polycyclic Aromatic Hydrocarbons (PAHs) in Toluene

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

Tar measurement by the Solid Phase Adsorption (SPA) method

Sample Pre-Treatment : Introduction to Commonly Used Techniques for Gas

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

GC-CI-MS analysis of TMS derivatives

Report on the third inter-laboratory comparison test organised by the Community Reference Laboratory for Polycyclic Aromatic Hydrocarbons

Application Note. Agilent Application Solution Analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection.

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

Reviewing Material Safety Data Sheets to Verify Significant Drinking Water Threats

Fast and Accurate Analysis of PBDEs in a Single Run, Including

Column Selection. there is more to life than a boiling point column. Jaap de Zeeuw Restek Corporation, The Netherlands. Copyrights: Restek Corporation

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Polycyclic Aromatic Hydrocarbons in Water by GC/MS PBM

New ZB-5HT Inferno The World s Highest Temperature Non-Metal GC Column

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Highly Sensitive and Rugged GC/MS/MS Tool

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

A New Web-Based Application for Modeling Gas Chromatographic Separations

A Direct 5 ms Column Performance Comparison for Active Semi-Volatile Analytes

A New Web-Based Application for Modeling Gas Chromatographic Separations. Dr. Hansjoerg Majer Restek Corporation Market Development Manager Europe

VGA-100 Instrument Detection Limits and Linearity

Author. Abstract. Introduction

Andrei Medvedovici, Florina Micăle, Florentin Tache

ILLA SpA VIA GHISOLFI GUARESCHI, NOCETO (PR)

Trajan SGE GC Columns

Method 8270C PAH. FD- Field Duplicate Samples

Semivolatile Organics Analysis Using an Agilent J&W HP-5ms Ultra Inert Capillary GC Column

Capillary GC Column Selection and Method Development A Primer on Column Parameters and Instrument Conditions

Introduction and Principles of Gas Chromatography

Organochlorine Pesticides by GCxGC-ECD

Secrets of GC Column Dimensions

Test Report. Report No. ECL01H Page 1 of 5

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

UNSUITABILITY OF THE ZEK/AFPS TEST METHOD FOR THE DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS IN CARBON BLACK

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

Determination of Hydrocarbon Components in Petroleum Naphthas

DiatoSorb-W Diatomaceous Earth: Great Chromatography Millions of Years in the Making

Volatile organic compounds (VOCs):

Environmental Forensic Principals for Sources Allocation of Polycyclic Aromatic Hydrocarbons

Defense Technical Information Center Compilation Part Notice

Appendix 1: Polycyclic Aromatic Compounds: Nomenclature and Analysis

The GC-APCI Interface for the Agilent Q-TOF LC/MS System Improves Sensitivity, Mass Accuracy, and Speed for a Wide Range of GC Applications

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

Analysis of Polycyclic Aromatic Hydrocarbons in Soil with Agilent Bond Elut HPLC-FLD

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

Transcription:

Rely on Rxi -PAH Columns to Ensure Successful Polycyclic Aromatic Hydrocarbon (PAH) Analysis Optimized Efficiency, Selectivity, and Robustness Let You: Report accurate results with speed and confidence. Prevent false positives for important isobaric PAHs. Reduce downtime with fewer column changes. Pure Chromatography

Rely on Rxi -PAH Columns to Ensure Successful Polycyclic Aromatic Hydrocarbon (PAH) Analysis Food can contain dozens of polycyclic aromatic hydrocarbons (PAHs) and, while research has shown that some are genotoxic and carcinogenic, others are not known to be harmful to human health. This creates one of the leading challenges for food safety laboratories: how to accurately report toxic PAHs, without high bias or false positives caused by nontoxic PAHs. The main difficulty in determining if PAH concentrations exceed maximum levels is that less toxic PAHs coelute with harmful target compounds. Whether these PAH interferences are known and reported together or are unknown and contributing bias, these coelutions increase the risk of safe food being reported as containing PAHs above maximum levels. While mass spectrometry (MS) often can resolve compounds of interest from coeluting interferences, in PAH analysis there are isobaric interferences that are indistinguishable by MS. Because the EFSA PAH4 group [1], as well as other frequently analyzed PAH lists, includes isobars that must be separated chromatographically, column choice is an essential consideration. The Rxi -PAH column from Restek is designed specifically for comprehensive PAH analysis in food and is the best column on the market today for these applications. Column dimensions were chosen to maximize efficiency and the selectivity of the proprietary stationary phase has been optimized to maximize resolution between critical pairs. In addition, the stabilized, bonded, arylene phase provides high temperature stability and excellent robustness. This combination of efficiency, selectivity, and robustness makes the Rxi -PAH column the best choice for successful PAH analysis. Generate Data With Greater Confidence and Speed Using an Rxi -PAH Column The optimized separating power of the Rxi -PAH column provides the best performance for PAH analysis. Compared to other columns, the Rxi -PAH column provides good separations faster and in a more straightforward analysis. Figure 1 contrasts the performance of an Rxi -PAH column (40 m x 0.18 mm x 0.07 µm) and a competitor s PAH column (0 m x 0.25 mm x 0.15 µm) in an analysis optimized for EFSA PAH4 compounds. Although the competitor column is 10 m shorter than the Rxi -PAH column, a ~0% faster analysis is achieved on the Restek column with a simpler oven program (red overlay). This optimization is possible because the enhanced efficiency and selectivity of the Rxi -PAH column allows for resolution of critical compounds, including the benzo [b], [k], and [ j] fluoranthenes, while still eluting the heavier PAHs in a short analysis time. Because thinner films bleed less, there is very little interference from column bleed, making the Rxi -PAH column an excellent choice for the low-level MS analyses of PAHs in food. [1] Scientific Opinion of the Panel on Contaminants in the Food Chain on a request from the European Commission on Polycyclic Aromatic Hydrocarbons in Food, The EFSA Journal 724 (2008) 1.

Figure 1: A faster and more straightforward analysis can be achieved with an Rxi -PAH column due to its higher efficiency and optimized selectivity. Rxi -PAH Column 50 C Superior separation of chrysene/triphenylene and other critical PAHs. Get better separations faster with an Rxi -PAH column! 110 C GC_FF122 Column: Rxi -PAH, 40 m, 0.18 mm ID, 0.07 µm (cat.# 4916); Sample: NIST SRM 2260a PAH mix; Diluent: Toluene; Conc.: 0.2-2 µg/ml (SRM 2260a PAH mix was diluted 5x in toluene); Injection: Inj. Vol.: 0.5 µl pulsed splitless (hold 0.58 min); Liner: Restek Premium 2 mm single taper w/wool (cat.# 216.1); Inj. Temp.: 275 C; Pulse Pressure: 80 psi (551.6 kpa); Pulse Time: 0.6 min; Purge Flow: 40 ml/min; Oven: Oven Temp.: 110 C (hold 1 min) to 210 C at 7 C/min to 260 C at C/min to 50 C at 11 C/min (hold 4.5 min); Carrier Gas: He, constant flow; Flow Rate: 1.4 ml/min; Detector: MS; Mode: SIM. For complete instrument conditions, visit and enter GC_FF122 in the search. Red line = oven temperature program. Competitor PAH Column 1 50 C 2 1 28 17 16 4 12 22.50 25 27 14 1 29 26 0 2 15 2.50 24.50 25.50 26.50 9.00 9.50 40.00 40.50 41.00 41.50 42.00 42.50 18 7 19 20 21 10 11 0.40 0.80 1.20 1.60 2.00 2.40 5 6 8 22 2 70 C 24 9 5.00 10.00 15.00 20.00 25.00 Time (min) 0.00 5.00 40.00 4 5 6 45.00 GC_FF1229 Conditions based on column manufacturer's recommendations. Column: Vendor A PAH Column, 0 m, 0.25 mm ID, 0.15 µm; Injection: Inj. Vol.: 1.0 µl splitless (hold 1.0 min); Oven: Oven Temp.: 70 C (hold 0.7 min) to 180 C at 85 C/min to 20 C at C/min (hold 7 min) to 280 C at 28 C/min (hold 10 min) to 50 C at 14 C/min (hold 4 min); 1-814-5-100 1-800-56-1688 Carrier Gas: He, constant flow; Flow Rate: 2.0 ml/min; Detector: MS. For complete instrument conditions,visit and enter GC_FF1229 in the search. Peaks 1. Naphthalene 2. Biphenyl. Acenaphthylene 4. Acenaphthene 5. Fluorene 6. Dibenzothiophene 7. Phenanthrene 8. Anthracene 9. 4H-Cyclopenta[def] phenanthrene 10. Fluoranthene 11. Pyrene 12. Benzo[ghi]fluoranthene 1. Benzo[c]phenanthrene 14. Benz[a]anthracene 15. Cyclopenta[cd]pyrene 16. Triphenylene 17. Chrysene 18. Benzo[b]fluoranthene 19. Benzo[k]fluoranthene 20. Benzo[j]fluoranthene 21. Benzo[a]fluoranthene 22. Benzo[e]pyrene 2. Benzo[a]pyrene 24. Perylene 25. Dibenz[a,j]anthracene 26. Dibenz[a,c]anthracene 27. Indeno[1,2,-cd]pyrene 28. Dibenz[a,h]anthracene 29. Benzo[b]chrysene 0. Picene 1. Benzo[ghi]perylene 2. Anthanthrene. Dibenzo[b,k]fluoranthene 4. Dibenzo[a,e]pyrene 5. Coronene 6. Dibenzo[a,h]pyrene

Get Better Separations of Key Food PAHs and Interferences With a Higher Efficiency Column Maximum efficiency is absolutely required for any analysis involving many potentially isobaric interferences that elute closely with compounds of interest, as is the case with PAH analysis. Efficiency is a function of peak width, with more efficient columns producing narrower peaks. Narrower peaks are also taller peaks, which means that not only is resolution between closely eluting compounds increased, but sensitivity is also improved. As shown in Figure 2, columns with higher efficiency give much better separation of compounds independent of stationary phase selectivity, and they also provide improved peak responses, which is critical for trace analyses like PAHs in food. Figure 2: High efficiency helps to separate compounds independent of column selectivity. High efficiency Rxi -PAH columns provide better separations and improved peak responses, which are required for successful PAH analysis. A. Higher efficiency separation Higher efficiency columns give tall, narrow peaks and better separations and responses B. Lower efficiency separation Restek s Rxi -PAH columns were developed with stabilized thin films that are specifically optimized to increase efficiency. Thinner films result in more efficient columns because thin films have a higher rate of mass transfer than thicker films. Beta value, or phase ratio, is related to efficiency and is based on the ratio of column ID to film thickness. Thinner film columns have higher beta values, and thus higher efficiency. Restek developed the Rxi -PAH column with a very thin film, while preserving the robustness required for difficult matrices (see robustness data on p. 7). The beta values for all configurations are > 600, which is significantly higher than PAH columns from other manufacturers and also, for reference, higher than general-purpose columns with a 0.25 mm ID and 0.25 µm film thickness (Figure ). Rxi -PAH columns are the highest efficiency PAH column available, and higher efficiency ensures better resolution of critical compounds. 4

Figure : Restek s Rxi -PAH columns have higher beta values than competitor PAH columns for maximum efficiency. 700 600 500 Beta Value 400 00 200 100 0 General (0.25 mm x 0.25 µm) Competitor PAH 1 (0.15 mm x 0.10 µm) Competitor PAH 2 (0.25 mm x 0.15 µm) Restek PAH 1 (0.18 mm x 0.07 µm) Restek PAH 2 (0.25 mm x 0.10 µm) Column efficiency can be measured using theoretical plate number, which is directly proportional to peak width. Because of their optimized film thicknesses and beta values, Restek Rxi -PAH columns have between 14,000 and 98,000 more theoretical plates per column than competitor columns, allowing for separations of critical closely-eluting compounds (Figure 4). Figure 4: Restek s Rxi -PAH columns have more theoretical plates than competitor PAH columns, which results in better separations. Efficiency (Theoretical Plates per Column) 200000 180000 160000 140000 120000 100000 80000 60000 40000 20000 0 Competitor 15m PAH Competitor 0m PAH Restek 0m PAH Restek 40m PAH Restek 60m PAH For reference, a typical midpolarity column has 105,000 plates per column. 5

Optimized Rxi -PAH Selectivity Separates all Priority EFSA PAH4 PAHs From Interferences In addition to maximum efficiency, optimized selectivity is necessary for successful PAH analysis, especially when separating EFSA PAH4 compounds chrysene and benzo[b]fluoranthene from interfering isobaric PAHs. While some columns separate one of these key PAHs, no column separates both chrysene and benzo[b]fluoranthene from their interferences better than the Rxi -PAH column. For example, low phenyl phases (e.g., 5-type columns) will resolve triphenylene and chrysene, but will not resolve benzo[b] fluoranthene and benzo[j]fluoranthene. Conversely, with higher phenyl content phases (e.g., 17-type columns), good separation can be achieved between benzo[b] fluoranthene and benzo[j]fluoranthene, but the triphenylene/chrysene separation is severely compromised. In contrast, the Rxi -PAH column proves excellent separation of both triphenylene and chrysene, as well as all the benzo fluoranthenes. As shown in Figure 5, this column provides the outstanding separations needed for accurate quantification, even in complex matrices such as tea. With its optimized selectivity, reliable results can be obtained quickly and accurately using an Rxi -PAH column and method, even in difficult food matrices that contain many PAH interferences. Get Our Method Download Restek s full application note on analyzing PAHs in tea. Visit and enter FFAN2086-UNV in the search. Figure 5: Excellent separation of important PAHs from interferences on an Rxi -PAH column ensures accurate reporting. Peaks t R (sec) 5 1 1. Benzo[b]fluoranthene 1,40.6 2. Benzo[k]fluoranthene 1,409.6. Benzo[ j]fluoranthene 1,41.6 4. Benzo[a]fluoranthene 1,41.6 5. Benzo[e]pyrene 1,478.2 6. Benzo[a]pyrene 1,489.0 7. Perylene 1,511.4 = m/z 252 6 Column: Rxi -PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 4917); Injection: Inj. Vol.: 2.5 µl splitless (hold 1 min); Liner: Restek Premium 4 mm single taper w/wool (cat.# 20.5); Inj. Temp.: 275 C; Purge Flow: 40 ml/min; Oven: Oven Temp.: 80 C (hold 1 min) to 210 C at 40 C/min to 260 C at C/min to 50 C at 11.5 C/min (hold 6.25 min); Carrier Gas: H 2, constant flow; Flow Rate: 2.4 ml/min; Detector: TOFMS; Transfer Line Temp.: 20 C; Analyzer Type: TOF; Source Temp.: 00 C; Electron Energy: 70 ev; Mass Defect: 0 mu/100 u; Solvent Delay; Time:.67 min; Tune Type: PFTBA; Ionization Mode: EI; Acquisition Range: 45-550 amu; Spectral Acquisition Rate: 5 spectra/sec; Instrument: LECO Pegasus 4D GCxGC-TOFMS 2 4 7 1,400 1,420 1,440 1,460 1,480 Time (sec) 4 1,500 GC_FF1245 Peaks t R (sec) 1. Benz[a]anthracene 1,028.4 2. Cyclopenta[cd]pyrene 1,044.0. Triphenylene 1,050.0 4. Chrysene 1,054.8 = m/z 228 = m/z 226 1 2 1,020 1,00 1,040 1,050 1,060 Time (sec) GC_FF1244 6

Reduce Downtime With Fewer Column Changes Robust Rxi -PAH Columns Withstand High Temperatures and Harsh Matrices While thin film columns are very efficient, they may be less robust than thicker film columns under some conditions. In contrast, the Rxi -PAH column can withstand the high temperatures necessary to elute the heavier (e.g., 02 m/z) PAHs due to the robustness of its bonded, arylene-stabilized stationary phase. To demonstrate this, repeated injections of PAH standard were performed, with a final isothermal hold of 4.5 minutes at 50 C. Figure 6 shows that acceptable resolution between triphenylene/chrysene and the benzo fluoranthenes was maintained even after 464 injections and a total of 116 hours at 50 C. In fact, after 464 injections, the Rxi -PAH column is just beginning to approach the competitor s new, out-of-the-box resolution specification for triphenylene/chrysene. These columns are also robust enough to withstand repeated injections of dirty sample matrix. As shown in Figure 7, Rxi -PAH columns maintain excellent performance for the triphenylene/chrysene separation, even after 184 injections of oyster extract and 106 injections of paprika extract (Figure 7). Figure 6: Even after extended time at high temperatures, Rxi -PAH columns provide excellent separation of key PAHs, meaning less time and expense is lost to column replacement and maintenance. Triphenylene/Chrysene Time at 50 C Benzofluoranthenes R=1.12 R=0.85 R=0.76 0 hours (injection 1) 65 hours (injection 260) 116 hours (injection 464) Column: Rxi -PAH, 40 m, 0.18 mm ID, 0.07 µm (cat.# 4916); Sample: Mixed PAH standard prepared at 10 40 µg/ml from neat materials in toluene; Injection: 0.5 µl pulsed splitless (hold 0.58 min); Liner: Restek Premium 2 mm single taper w/wool (cat.# 216.1); Inj. Temp.: 275 C; Pulse Pressure: 80 psi (551.6kPa); Pulse Time: 0.6 min; Purge Flow: 40 ml/min; Oven Temp: 110 C (hold 1 min) to 210 C at 5 C/min to 260 C at C/min to 50 C at 10 C/min (hold 15 min); Carrier Gas: He, constant flow; Flow Rate: 1.4 ml/min; Detector: FID @ 60 C. b k j Figure 7: Good separation of triphenylene and chrysene is maintained even after repeated injections of dirty extracts. 1 Triphenylene/chrysene Triphenylene/chrysene separation still acceptable after separation a 184 oyster, still 106 acceptable paprika, and 107 standard injections! after a 184 oyster, 106 paprika, and 107 standard injections! 2 Peaks 1. Benz[a]anthracene 2. Triphenylene. Chrysene Column: Rxi -PAH, 40 m, 0.18 mm ID, 0.07 µm (cat.# 4916); Sample: Custom PAH standard; Diluent:Toluene; Injection: Inj Vol.: 0.5 µl pulsed splitless; Liner: Restek Premium 2 mm single taper w/wool (cat.# 216.1); Inj. Temp.: 275 C; Pulse Pressure: 80 psi (551.6kPa); Pulse Time: 0.6 min; Purge Flow: 40 ml/min; Oven: Oven Temp.: 110 C (hold 1 min) to 210 C at 5 C/min to 260 C at C/min to 50 C at 10 C/min (hold 4.5 min); Carrier Gas: He, constant flow; Flow Rate: 1.4 ml/min; Detector: FID @ 60 C; Make-up Gas; Flow Rate: 45 ml/min; Make-up Gas Type: N2; Hydrogen flow: 40 ml/min; Air flow: 450 ml/min; Instrument: Agilent 7890A GC Notes: The experiment was carried out as follows: - Oysters and paprika were extracted using QuEChERS methodology. - dspe cleanup was performed on oyster extracts. - Cartridge cleanup was performed on paprika extracts. - Oyster and paprika extracts were injected, interspersed with solvent standard, to monitor performance. 16. 16.4 16.5 16.6 16.7 16.8 16.9 17 17.1 Time (min) GC_FS054 7

Ensure Successful PAH Analysis with the Rxi -PAH Column Whether you are analyzing comprehensive lists or focusing on the EFSA PAH4, the Rxi -PAH column ensures your success by combining efficiency, selectivity, and robustness to produce a column that outperforms all competitors columns. In addition, every Rxi -PAH column is tested to ensure critical separations your guarantee of consistent column performance. Chose the configuration that best suits your application and be confident that you are reporting accurate PAH results without bias from interferences. Cat.# Length ID df Description 4916 40 m 0.18 mm 0.07 µm Narrow inside diameter, thinner film, faster analysis, excellent separation of important PAHs, less sample loading capacity 4917 60 m 0.25 mm 0.10 µm 0.25 mm inner diameter, better sample loading capacity, highest resolution of important PAHs, longer analysis than 0.18 mm column, thin film allows elution of dibenzo pyrenes 4918 0 m 0.25 mm 0.10 µm 0.25 mm inside diameter, better sample loading capacity, faster analysis time than 60 m column, adequate resolution of important PAHs, lower cost column Pair an Rxi -PAH Column with Certified Reference Standards EU 15+1 PAH Standard (16 components) Benz(a)anthracene (56-55-) Benzo(a)pyrene (50-2-8) Benzo(b)fluoranthene (205-99-2) Benzo(c)fluorene (,4-Benzofluorene) (205-12-9) Benzo(g,h,i)perylene (191-24-2) Benzo( j)fluoranthene (205-82-) Benzo(k)fluoranthene (207-08-9) Chrysene (218-01-9) Cyclopenta(c,d)pyrene (27208-7-) Dibenz(a,e)pyrene (192-65-4) Dibenz(a,h)anthracene (5-70-) Dibenzo(a,h)pyrene (189-64-0) Dibenzo(a,i)pyrene (189-55-9) Dibenzo(a,l)pyrene (191-0-0) Indeno(1,2,-cd)pyrene (19-9-5) 5-Methylchrysene (697-24-) 100 µg/ml each in toluene, 1 ml/ampul cat.# 2470 (ea.) PAH Interferences Standard (5 components) Benzo( j)fluoranthene (205-82-) 750 µg/ml Benzo(k)fluoranthene (207-08-9) 1,000 Benzo(e)pyrene (192-97-2) 500 Perylene (198-55-0) 250 Triphenylene (217-59-4) 750 In toluene, 1 ml/ampul cat.# 2472 (ea.) EFSA PAH4 Standard (4 components) Benz[a]anthracene (56-55-) Benzo[a]pyrene (50-2-8) Benzo[b]fluoranthene (205-99-2) Chrysene (218-01-9) 1,000 µg/ml each in toluene, 1 ml/ampul cat.# 2469 (ea.) Pure Chromatography Questions about this or any other Restek product? Contact us or your local Restek representative (/contact-us). Restek patents and trademarks are the property of Restek Corporation. (See /Patents-Trademarks for full list.) Other trademarks in Restek literature or on its website are the property of their respective owners. Restek registered trademarks are registered in the U.S. and may also be registered in other countries. 2015 Restek Corporation. All rights reserved. Printed in the U.S.A. Lit. Cat.# FFSS2114-UNV