SCANNING UV VISIBLE SPECTROPHOTOMETER

Similar documents
NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

SPECTROPHOTOMETERS. Visible and UV-Visible

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

Compact Knowledge: Absorbance Spectrophotometry. Flexible. Reliable. Personal.

Biochrom Libra. UV-Visible Spectrophotometers. High performance instruments with added application value for academia, research and industry

TL6 Ultra Micro-volume Spectrophotometer

INFORMATION LABORATORY ANALYSIS UV-VIS SPECTROPHOTOMETER DR Simply more DR 5000 UV-VIS Spectrophotometer

Nano Spectrophotometer LNS-A10

novaa 800 D Atomic Absorption Spectrometer

SolidSpec-3700 SolidSpec-3700DUV

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry

The Plus for your lab!

BioDrop DUO dsdna Application Note

C101-E107B UV Shimadzu UV-VIS-NIR Spectrophotometer

25 Instruments for Optical Spectrometry

Making competence visible Flexible. Reliable. Personal.

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

2001 Spectrometers. Instrument Machinery. Movies from this presentation can be access at

GTEK Laboratory Atomic Absorption Spectrometer AAS6000 Brochure

Characterisation & Use of Array Spectrometers

Stray Light Rejection in Array Spectrometers

Spectroscopy. Page 1 of 8 L.Pillay (2012)

C101-E111. Talk Letter. Vol.2 February 2009

2. To measure the emission lines in the hydrogen, helium and possibly other elemental spectra, and compare these to know values.

Spectroscopy: Introduction. Required reading Chapter 18 (pages ) Chapter 20 (pages )

RINCIPLE OF COLORIMETER AND SPECTOPHOTOMETER AND VARIOUS TYPE OF ANALYSER USED IN CLINICAL BIOCHEMISTRY

Traceable UV-Vis Reference Materials

The Clinical Chemistry System that offers more so you do less!

Absorption photometry

CEE 772: Instrumental Methods in Environmental Analysis

JABLONSKI DIAGRAM 2/15/16

Investigating Transition Metal Complexes

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

NEW! PCR next to me. Eppendorf Mastercycler nexus: combine, connect, control

Far UV Performance of the LAMBDA 850/950 UV/Vis and UV/Vis/NIR Research Spectrophotometers

THE MEASUREMENT OF SOLAR ULTRAVIOLET SPECTRAL IRRADIANCE PROBLEMS & SOLUTIONS

Colorimeters and UV/Visible Spectrophotometers

Jasco V-670 absorption spectrometer

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Chemistry 524--Final Exam--Keiderling Dec. 12, pm SES

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

NANOCOLOR UV /VIS & VIS

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

ChromTech HPLC System

Defining quality standards for the analysis of solid samples

Instrumental Technique: Cuvette. Md Rabiul Islam

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Spectral Calibration of Ultra- High Resolution Volume Holographic Spectrometer. Jeff Bourne Majid Badiei (Advisor)

Introduction to Fourier Transform Infrared Spectroscopy

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

PD300 PD300-1W PD300-3W PD300-TP

Atomic Absorption Spectrometer ZEEnit P series

Overview of Spectroscopy

FLUORESCENCE APPLICATIONS

High Resolution Optical Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy

Elemental analysis by X-ray f luorescence. High performance EDXRF elemental analyzer

COLORIMETER AND LAMBERT S-BEER S LAW. Shingala vaishali Sandha prafulla Tiwari Kuldeep

JAPAN QUALITY. Automated Clinical Analyzer

Chem 310 rd. 3 Homework Set Answers

The solution for all of your

Physics P202, Lab #12. Rydberg s Constant

FLS980 Series Reference Guide

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

Microplate Spectrophotometer

COMBI has been developed to be easily integrated in all types of laboratories and hospitals for routine, emergency as well as specific analysis.

Quantum Northwest, Inc. Product overview

1901 Application of Spectrophotometry

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

C101-E116. Talk Letter. Vol.4 March 2010

Spectrophotometer for Life Science. BioSpec-nano C101-E112D

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

RamanStation 400: a Versatile Platform for SERS Analysis

THE DIFFRACTION GRATING SPECTROMETER

Dissolution Automation: Basic Questionnaire.

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

Research Gamma Counter

Instrumental Analysis: Spectrophotometric Methods

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations

Optical Reagent-Free Measurement of COD, Nitrate, Nitrite with photolab 7600

Colorimeters and UV/Visible Spectrophotometers

Background The power radiated by a black body of temperature T, is given by the Stefan-Boltzmann Law

A DIVISION OF ULVAC-PHI

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

Performance of Semi-micro and Single Drop Analysis by Using. Flash Xenon Lamp Spectrophotometer

levels. The signal is either absorbance vibrational and rotational energy levels or percent transmittance of the analyte

Outline of Recombinant DNA technology. Application of UV spectroscopy in recombinant DNA technology

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Electronic Excitation by UV/Vis Spectroscopy :

LDLS Laser-Driven Light Source

ABX Pentra 400. Clinical Chemistry System. Up to 420 tests/hour 55 Assays Validation Station

Nanoparticle Analyzer

Laboratory Measurements and Procedures

Engineering Note. Measuring the Polarization Rotation Angle of a Faraday Rotator Mirror with the Optical Vector Analyzer

Clinical Chemistry (CHE221) Professor Hicks Week 1. Statistics Made Slightly Less Boring and Introduction to Spectrophotometry. Accuracy vs Precision

Transcription:

PRODUCT CATALOG SCANNING UV VISIBLE SPECTROPHOTOMETER www.biolabscientific.com

SCANNING UV VISIBLE SPECTROPHOTOMETER We combine ease of use with reliability for your routine analysis and research applications. Our product offers the measurement range of 190-1100nm at bandwidth of 1.8nm/4m which provides better performance and increases lab productivity. Its affordable price and availability of optional accessories make it a versatile addition to your lab. 100 SERIES SCANNING UV VISIBLE SPECTRO- PHOTOMETER SPECIFICATIONS Wavelength range: 190nm-1100nm Optical System: Double beam optical system Czerny-Turner diffraction monochromator having 1200 lines/mm grating Bandwidth: 1.8nm/4nm Detector: Silicon Photodiode Wide Measurement Range with ultra-low Stray Light at highest Resolution: With its ultra-low stray light ( 0.05 %T (220nm, 340nm)) is achieved at wavelength range of 190-1100 nm Multi-wavelength pinpoint test for simultaneous testing of up to 30 wavelengths Flexibility with various sample size: A wide range of standard cuvettes can be use based on the sensitivity or sample volume requirements. Sophisticated and simplified sample analysis software: The Sample analysis software deliver scanning, fixed wavelength analysis, quantitative analysis, data collection, storage, export, and reporting. With additional feature of an easy access USB port available in the unit, which enables results to be stored directly to a USB memory stick for easy transfer of data. Automatic 4-position cell holder and optional 7-position or 16-position cell holder Variety of optional accessories suitable for different applications including reflection sample holder, solid sample holder, water bath and auto sampler USB data interface with online PC software ensures powerful function and data processing capabilities Model BSSUB-101 BSSUB-101-PC Wavelength Range 190-1100 nm Wavelength Accuracy ±0.1 nm (656.1nm D2); ±0.5 nm (whole wavelength range) Wavelength Repeatability ±0.15 nm Spectral Bandwidth 1.8 nm/4 nm Spectral Resolution 0.1 nm Photometric Range 0-200 %T; -3-3 A; -9999-9999 C Photometric Accuracy ±0.002A (0-0.5A); ±0.004A (0.5-1A); ±0.008A (1-2A); ±0.3% (0-100%T) Photometric Repeatability ±0.002A (0-0.5A); ±0.004A (0.5-1A); ±0.008A (1-2A); ±0.15% (0-100%T) Stability ±0.001 A/h at 500 nm, 0 A Baseline Flatness ±0.0015 A Derivative resolution >0.5 Stray Light 0.05%T (220 nm,nai;340 nm,nano2) Optical System Accurate double beam, Czerny-Turner, Grating 1200 line/mm Gross Dimension (W/D/H) 470x390x225 mm Display LCD (320 240 pixel) Noise ±0.001A Weight (Net/Gross) 20 kg Light Source - Software - PC with online software 2 www.biolabscientific.com

OPTIONAL ACCESSORIES Accessory Code Name Optical length BX-103668 Quartz Cells - Melt together 1mm BX-103669 Quartz Cells - Melt together 2mm BX-103670 Quartz Cells - Melt together 5mm BX-103671 Quartz Cells - Melt together 10mm BX-103672 Quartz Cells - Melt together 20mm BX-103673 Quartz Cells - Melt together 30mm BX-103674 Quartz Cells - Melt together 40mm BX-103675 Quartz Cells - Melt together 50mm BX-103676 Quartz Cells - Melt together 100mm BX-103677 Glass Cell - Melt together 1mm BX-103678 Glass Cell - Melt together 2mm BX-103679 Glass Cell - Melt together 5mm BX-103680 Glass Cell - Melt together 10mm BX-103681 Glass Cell - Melt together 20mm BX-103682 Glass Cell - Melt together 30mm BX-103683 Glass Cell - Melt together 40mm BX-103684 Glass Cell - Melt together 50mm BX-103685 Glass Cell - Melt together 100mm BX-103686 Quartz fluorescence cell ( With cover) - Melt together 10mm BX-103687 10mm Quartz Cells (with plug) - Melt together 10mm BX-103688 Micro cuvette - Melt together 10mm (1, 2, 4mm slit) BX-103689 Quartz Cells - Hydrogel type 1mm BX-103690 Quartz Cells - Hydrogel type 2mm BX-103691 Quartz Cells - Hydrogel type 5mm BX-103692 Quartz Cells - Hydrogel type 10mm BX-103693 Quartz Cells - Hydrogel type 20mm BX-103694 Quartz Cells - Hydrogel type 30mm BX-103695 Quartz Cells - Hydrogel type 40mm BX-103696 Quartz Cells - Hydrogel type 50mm BX-103697 Quartz Cells - Hydrogel type 100mm BX-103698 Glass Cell - Hydrogel type 1mm BX-103699 Glass Cell - Hydrogel type 2mm BX-103700 Glass Cell - Hydrogel type 5mm BX-103701 Glass Cell - Hydrogel type 10mm BX-103702 Glass Cell - Hydrogel type 20mm BX-103703 Glass Cell - Hydrogel type 30mm BX-103704 Glass Cell - Hydrogel type 40mm BX-103705 Glass Cell - Hydrogel type 50mm BX-103706 Glass Cell - Hydrogel type 100mm BX-103707 Quartz fluorescence cell ( With cover) - Hydrogel type 10mm BX-103708 Micro cuvette - Hydrogel type 10mm (1, 2, 4mm slit) BX-103709 Black Micro cuvette (avoid light) - Hydrogel type 10mm (1, 2, 4mm slit) BX-103710 Tungsten Lamp BX-103711 Deuterium lamp Heraeus 2.5V SCANNING UV VISIBLE SPECTROPHOTOMETER www.biolabscientific.com 3

100 SERIES SCANNING UV VISIBLE SPECTRO- PHOTOMETER Wavelength range: 190nm-1100nm Optical System: Double beam optical system Czerny-Turner diffraction monochromator having 1200 lines/mm grating Bandwidth: 1.8nm/4nm Detector: Silicon Photodiode Wide Measurement Range with ultra-low Stray Light at highest Resolution: With its ultra-low stray light ( 0.05 %T (220nm, 340nm)) is achieved at wavelength range of 190-1100 nm Multi-wavelength pinpoint test for simultaneous testing of up to 30 wavelengths Flexibility with various sample size: A wide range of standard cuvettes can be use based on the sensitivity or sample volume requirements. Sophisticated and simplified sample analysis software: The Sample analysis software deliver scanning, fixed wavelength analysis, quantitative analysis, data collection, storage, export, and reporting. With additional feature of an easy access USB port available in the unit, which enables results to be stored directly to a USB memory stick for easy transfer of data. USB data interface with online PC software ensures powerful function and data processing capabilities Automatic 4-position cell holder and optional 7-position or 16-position cell holder Variety of optional accessories suitable for different applications including reflection sample holder, solid sample holder, water bath and auto sampler SPECIFICATIONS Model BSSCU-101 BSSCU-102 BSSCU-103 BSSCU-104 Wavelength Range 190-1100 nm Wavelength Accuracy ±0.5 nm ±0.3 nm Wavelength Repeatability 0.3 nm 0.2 nm Spectral Bandwidth 4 nm 2 nm 1.8 nm 1 nm Photometric Range 0.200 %T, -0.3-3.0 A Photometric Accuracy ±0.5 %T or ±0.003A at 1A Stability ±0.002 A/h at 500 nm Baseline Flatness ±0.002 A (200-1000 nm) Scan Speed Hi, Med., Low, Max 3000 nm/min Stray Light 0.05 %T at 220,360 nm Light Source Tungsten Halogen Lamp and Deuterium Lamp Optical System Single Beam, Grating 1200 lines/mm Gross Dimension (W/D/H) 480x360x160 mm 600x450x200 mm Display 5 inches LCD (320x240 dots) Weight (Net/Gross) 14 kg 20 kg Power Supply AC110V/220V 50Hz/60Hz 4 www.biolabscientific.com

OPTIONAL ACCESSORIES Accessory Code Name Description Unit Light Path (mm) BX-103766 Holder 4-cell holder for up to 50mm square cuvette BX-103767 Holder 4-cell holder for up to 100mm square cuvette BX-103768 Holder Long path single cell holder for 100mm BX-103769 Holder Single cell holder for 10mm square BX-103770 Holder Cylindrical cell holder(ø16mm) BX-103779 5 reflectance meachment attachment (minimum sample:20x20mm, central beam height:50mm) BX-103780 Lamp 6v10w halogen lamp BX-103781 Lamp 12v20w halogen lamp (phillips) BX-103782 Lamp 12v20w halogen lamp (osram) BX-103783 Lamp Milas deuterium lamp, 10v,300ma, 30w BX-103784 Lamp Deuterium lamp BX-103785 BX-103786 Thermo printer Stylus printer BX-103787 s Square cuvettes, glass 10mm /4pcs BX-103788 s Square cuvettes, glass 20mm /4pcs BX-103789 s Square cuvettes, glass 30mm /4pcs BX-103790 s Square cuvettes, glass 50mm /4pcs BX-103791 s Square cuvettes, glass 100mm /4pcs BX-103792 s Square cuvettes, quartz 10mm /2pcs BX-103793 s Square cuvettes, quartz 20mm /2pcs BX-103798 BX-103799 s s 500ul micro cell, central-beam height:8.5mm,15mm, 2x10x45mm, quartz 1000ul micro cell, central-beam height:8.5mm,15mm, 3x10x45mm, quartz BX-103800 Software Dongles for 31.61 application software, (UV analyst software) /1set BX-103801 Software Software (m.wave basic) /1set BX-103802 Software Software /1set BX-103803 Software Advanced PC window software (m.wave professional) /1set BX-103804 Software Software (m.wave basic) /1set BX-103805 Holder Cell holder for micro cells, Central beam height: 15mm BX-103806 USB connector line USB connector line (only for m.wave basic) BX-103807 Quartz Cell, 100ul, 1pcs, central beam height: 15mm 10 BX-103808 Quartz Cell, 200ul, 1pcs, central beam height:15mm 10 BX-103809 BX-103810 BX-103811 BX-103812 BX-103813 BX-103815 Flow cell, 5 mm, optical glass, 1pcs, central beam height:15mm, l5xw2xh5mm Flow cell, 10 mm, optical glass, 1pcs, central beam height:15mm, l10xw2xh5mm Flow cell, 20 mm, optical glass, 1pcs, central beam height:15mm, 20Lx2Wx5H mm Flow cell, 30 mm, optical glass, 1pcs, central beam height:15mm, l30xw2xh5mm Flow cell, 5 mm, quartz, 1pcs, central beam height:15mm, l5xw2xh5mm Flow cell, 20 mm, quartz, 1pcs, central beam height:15mm, l20xw2xh5mm SCANNING UV VISIBLE SPECTROPHOTOMETER www.biolabscientific.com 5

BX-103817 BX-103819 A-102 peltier system, constant-temperature system, holder beam height:15mm A-100 peltier/sipper system, constant-temperature sipper system, holder beam height:15mm BX-103820 Holder 4-cell holder for 10mm to 50mm square cuvette BX-103821 Holder 4-cell holder for up to 100mm square cuvette BX-103825 Holder 10mm water-jacketed 4-cell holder BX-103826 Holder Test tube holder(ø8-ø22mm) BX-103827 Holder Solid sample holder( δ 1.5 mm 3mm,m -position) BX-103828 Silicon tube Silicon tube, 1bag=1pair(1m+1m) /1bag BX-103831 Glass cuvettes Square cuvettes, volume:900ul 2 BX-103832 Glass cuvettes Square cuvettes, volume:450ul 1 BX-103833 Quartz cuvettes Square cuvettes, volume:1350ul /4pcs 3 BX-103834 Quartz cuvettes Square cuvettes, volume:900ul /4pcs 2 BX-103835 Quartz cuvettes Square cuvettes, volume:450ul /4pcs 1 BX-103836 Quartz cuvettes Square cuvettes, volume:1800ul /2pcs 5 6 www.biolabscientific.com

100 SERIES SCANNING UV VISIBLE SPECTRO- PHOTOMETER SPECIFICATIONS Wavelength range: 190nm-1100nm Optical System: Double beam optical system Czerny-Turner diffraction monochromator having 1200 lines/mm grating Bandwidth: 1.8nm/4nm Detector: Silicon Photodiode Wide Measurement Range with ultra-low Stray Light at highest Resolution: With its ultra-low stray light ( 0.05 %T (220nm, 340nm)) is achieved at wavelength range of 190-1100 nm Multi-wavelength pinpoint test for simultaneous testing of up to 30 wavelengths Flexibility with various sample size: A wide range of standard cuvettes can be use based on the sensitivity or sample volume requirements. Sophisticated and simplified sample analysis software: The Sample analysis software deliver scanning, fixed wavelength analysis, quantitative analysis, data collection, storage, export, and reporting. With additional feature of an easy access USB port available in the unit, which enables results to be stored directly to a USB memory stick for easy transfer of data. USB data interface with online PC software ensures powerful function and data processing capabilities Automatic 4-position cell holder and optional 7-position or 16-position cell holder Variety of optional accessories suitable for different applications including reflection sample holder, solid sample holder, water bath and auto sampler Model BSSNU-101 BSSNU-102 BSSNU-103 BSSNU-104 Wavelength Range 190-1100 nm Wavelength Accuracy ±0.5 nm ±0.3 nm Wavelength Repeatability 0.3 nm 0.2 nm Spectral Bandwidth 4 nm 2 nm 1.8 nm 1 nm Photometric Range Photometric Accuracy Stability Baseline Flatness Scan Speed Stray Light Light Source Optical System Software 0.200 %T, -0.3-3.0 A ±0.5 %T or ±0.003A at 1A ±0.002 A/h at 500 nm ±0.002 A (200-1000 nm) Hi, Med., Low, Max 3000 nm/min 0.05 %T at 220,360 nm Tungsten Halogen Lamp and Deuterium Lamp Single Beam, Grating 1200 lines/mm PC Software Gross Dimension (W/D/H) 480x360x160 mm 600x450x200 mm Display 5 inches LCD (320x240 dots) Weight (Net/Gross) 14 kg 20 kg Power Supply AC110V/220V 50Hz/60Hz SCANNING UV VISIBLE SPECTROPHOTOMETER www.biolabscientific.com 7

OPTIONAL ACCESSORIES Accessory Code Name Description Unit Light Path (mm) BX-103766 Holder 4-cell holder for up to 50mm square cuvette BX-103767 Holder 4-cell holder for up to 100mm square cuvette BX-103768 Holder Long path single cell holder for 100mm BX-103769 Holder Single cell holder for 10mm square BX-103770 Holder Cylindrical cell holder(ø16mm) BX-103779 5 reflectance meachment attachment (minimum sample:20x20mm, central beam height:50mm) BX-103780 Lamp 6v10w halogen lamp BX-103781 Lamp 12v20w halogen lamp (phillips) BX-103782 Lamp 12v20w halogen lamp (osram) BX-103783 Lamp Milas deuterium lamp, 10v,300ma, 30w BX-103784 Lamp Deuterium lamp BX-103785 BX-103786 Thermo printer Stylus printer BX-103787 s Square cuvettes, glass 10mm /4pcs BX-103788 s Square cuvettes, glass 20mm /4pcs BX-103789 s Square cuvettes, glass 30mm /4pcs BX-103790 s Square cuvettes, glass 50mm /4pcs BX-103791 s Square cuvettes, glass 100mm /4pcs BX-103792 s Square cuvettes, quartz 10mm /2pcs BX-103793 s Square cuvettes, quartz 20mm /2pcs BX-103798 BX-103799 s s 500ul micro cell, central-beam height:8.5mm,15mm, 2x10x45mm, quartz 1000ul micro cell, central-beam height:8.5mm,15mm, 3x10x45mm, quartz BX-103800 Software Dongles for 31.61 application software, (UV analyst software) /1set BX-103801 Software Software (m.wave basic) /1set BX-103802 Software Software /1set BX-103803 Software Advanced PC window software (m.wave professional) /1set BX-103804 Software Software (m.wave basic) /1set BX-103805 Holder Cell holder for micro cells, Central beam height: 15mm BX-103806 USB connector line USB connector line (only for m.wave basic) BX-103807 Quartz Cell, 100ul, 1pcs, central beam height: 15mm 10 BX-103808 Quartz Cell, 200ul, 1pcs, central beam height:15mm 10 BX-103809 BX-103810 BX-103811 BX-103812 BX-103813 BX-103815 Flow cell, 5 mm, optical glass, 1pcs, central beam height:15mm, l5xw2xh5mm Flow cell, 10 mm, optical glass, 1pcs, central beam height:15mm, l10xw2xh5mm Flow cell, 20 mm, optical glass, 1pcs, central beam height:15mm,l20xw2xh5mm Flow cell, 30 mm, optical glass, 1pcs, central beam height:15mm, l30xw2xh5mm Flow cell, 5 mm, quartz, 1pcs, central beam height:15mm, l5xw2xh5mm Flow cell, 20 mm, quartz, 1pcs, central beam height:15mm, l20xw2xh5mm 8 www.biolabscientific.com

BX-103817 BX-103819 A-102 peltier system, constant-temperature system, holder beam height:15mm A-100 peltier/sipper system, constant-temperature sipper system, holder beam height:15mm BX-103820 Holder 4-cell holder for 10mm to 50mm square cuvette BX-103821 Holder 4-cell holder for up to 100mm square cuvette BX-103825 Holder 10mm water-jacketed 4-cell holder BX-103826 Holder Test tube holder(ø8-ø22mm) BX-103827 Holder Solid sample holder( δ 1.5 mm 3mm,m -position) BX-103828 Silicon tube Silicon tube, 1bag=1pair(1m+1m) /1bag BX-103831 Glass cuvettes Square cuvettes, volume:900ul 2 BX-103832 Glass cuvettes Square cuvettes, volume:450ul 1 BX-103833 Quartz cuvettes Square cuvettes, volume:1350ul /4pcs 3 BX-103834 Quartz cuvettes Square cuvettes, volume:900ul /4pcs 2 BX-103835 Quartz cuvettes Square cuvettes, volume:450ul /4pcs 1 BX-103836 Quartz cuvettes Square cuvettes, volume:1800ul /2pcs 5 SCANNING UV VISIBLE SPECTROPHOTOMETER www.biolabscientific.com 9

Biolab Scientific Limited 3660 Midland Avenue, Suite 300, Toronto, Ontario M1V 0B8, Canada Email: contact@biolabscientific.com Phone:+1 416 639 2438 Website: www.biolabscientific.com