Model 33SZ Basic Unit OPTIONAL FILTER RH COIL CONNECTION PRIMARY/ DEDICATED OUTDOOR AIR MULTI-POINT FLOW SENSOR 5 3/4" (146)

Similar documents
BV SERIES. VERTICAL BLOWER COIL UNITS Nominal Sizes 2 thru 10 Ton

Energy Efficient Easy to Install Extended Service Life. Horizontal Direct Drive Blower Coils BUILD YOUR REPUTATION ON OURS

McQuay. Water Source Heat Pump. VF, VG, VP Vintage E, F, G. Last Manufactured: Replacement Parts List No Revision B 02/2017

10-year industry best core warranty. 2-year warranty on balance of unit.

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

42C/V. Fan Coil Unit 42C/V

B6VMAX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

ASTON SERIES AIR HANDLER

PARTS LIST WATER SOURCE HEAT PUMPS HLH/HLV

McQuay Climate Control Singer

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH

Repair Parts List DUEL FUEL RANGE MODEL NUMBER SVD48600BC. When requesting service or ordering parts, always provide the following information:

variable flow dampers

McQuay Climate Control Singer. Incremental. NE, NH, NR Vintages C, D. TYA, TAA Vintages A, B. Last Manufactured: 1999

KZPb

440V 500V V / / /2 12.

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

Singer. Incremental Comfort Systems. K, EK Vintage F. Last Manufactured: Replacement Parts List No Revision C 04/2012

579(XX).(X)(X)(X)(X) Modularized Roof Top Air Conditioner

Parts Manual R410A Models

McQuay Climate Control. Water Source Heat Pump Horizontal. CC, CG, CW Vintage C, D. Last Manufactured: 1984

3 Port, 2-Ton Outdoor Heat Pump

SWIFT Ceiling. Square ceiling air diffuser for supply air QUICK FACTS

CROSS FLOW COOLING TOWER

TeSys enclosed starters 2

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm

AIR COOLED CONDENSING UNIT

SWIFTTM. Ceiling. Square ceiling air diffuser for supply air

KSAb

VK2 volume flow controller Overview

Series 3000 and XE-Series Engineering Data

EXPLODED DIAGRAM - PARTS VIEW

Manual Control. Class 11-3RV, SMF, MMS. Wiring Diagrams 8/130. Signaling Contact for Class 11-3RV. Typical Wiring Diagrams Class SMF.

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

nufacturing Company, L.P San Felipe, Suite 500

nufacturing Company, L.P San Felipe, Suite

Water terminal control solutions

Air distribution systems. Adjustable induction outlet IN-V...

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

CS Series. Capacitance Type. Type. Proximity Sensor. Features

Twin City Fan Companies. Fan System Effects

ULTRA-SLIM POLARIZED RELAY. Initial breakdown voltage* 2. Unit weight. Ex. TN 2 L2 H 12V

REPAIR PARTS. GPG14 "M" Series Residential Package Gas Units. This manual is to be used by qualified technicians only. This manual replaces RP-G3001.

REPAIR PARTS. GPC15 Horizontal Package Cooling Units

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS CADB/T-N Series

Swirl Diffuser. Type SDW T 2.2/1/B/1. recommended for room heights from approx m

KZMb

REPAIR PARTS. GPH14 Multi-Position Residential Package Heat Pump. This manual is to be used by qualified technicians only.

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction

ENVIRONMENTALLY SOUND R 410A REFRIGERANT

Technical Explanation for Axial Fans

Sports Car Club Of America

4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY

MAINTENANCE EVALUATION CHECKLIST HYDRAULIC ELEVATORS

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

NME1854 & FME2404 SERVICE PARTS

BNA Series. PLENUM FAN with Backward Wheels

REPAIR PARTS. GPH14 H-SERIES R-410A Package Heat Pumps GPH1424H41AA GPH1430H41AA GPH1436H41AA GPH1442H41AA GPH1448H41AA GPH1460H41AA


6.0 EC-SERIES CUBERS EC200-EC300-EC400-EC500-EC606 AIR, WATER AND REMOTE

ALC. ALBATROSS Supply air terminal for large airflows

Fluid Cooling Shell & Tube EC Series

SECTION COIL SECTION COIL OPTIONAL: AUXILIARY DRAIN PAN FOR PIPING PACKAGE COIL CONFIGURATIONS (RH CONNECTIONS SHOWN) HEATING ONLY 1 COOLING PREHEAT

HVAC Electrical Wiring Diagrams / Ohm s Law / Sequence of Operation RV

GB5BM Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler WARRANTY

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

nufacturing Company, L.P San Felipe, Suite 500

-NC030R14E, NC030R24, -NC030R24E)

Better Air is Our Business. Table of Contents. 1.0 Introduction

nufacturing Company, L.P San Felipe, Suite

AIR COOLED CONDENSING UNIT

END4X, ENW4X, ENA4X. Product Specifications VERTICAL EVAPORATOR COILS ALL N COIL MODELS CASED N COILS UNCASED N COILS ENA4X WARRANTY*

REPAIR PARTS. GPH14 "M" Series Residential Package Heat Pump. This manual is to be used by qualified technicians only.

XHDU Cassette type fan-coils for double/four pipe connections 1,98-14 kw HYDRONIC TERMINALS

FDB1050REB2 FDB1050REC2 FDB1050REM2 FDB1050REQ2 FDB1050RES2

PARTS MANUAL Gas Furnace F8MXN, F8MXL, G8MXN, G8MXL

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

REPAIR PARTS. DP13CH Residential Package Heat Pump

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

OUTDOOR UNITS. Introduction YMF-C. Introduction. Refrigerant

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction

ENH4X. Product Specifications HORIZONTAL EVAPORATOR COILS ALL CASED N COIL MODELS WARRANTY*

REPAIR PARTS. *PD14 Dual Fuel Package Units

Constant flow damper

CDD/CDR. Circular ceiling diffuser for supply air QUICK FACTS

Parts List with Exploded Views

WALL MOUNT HEATER PACKAGES REPLACEMENT PARTS MANUAL. General Notes. Contents. Important

Blizzard. Outdoor. Projector Enclosures 5-15K. Fourth eneration. Projector Enclosures

4.4 E 60/E 100 ELECTRIC ACTUATORS E 60/E 100 TECHNICAL DATA E 60 GENERAL APPLICATIONS E 100 FEATURES. Valve interface: EN ISO 5211

GMVC8. ComfortNet -Compatible. Heating Input: 70, ,000 BTU/h. Two-Stage, Variable-Speed Gas Furnace

General Purpose Relays Types K, R, N, and C

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

Piping Systems and Flow Analysis (Chapter 3)

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

PARTS CATALOG. No. OBB702 REVISED EDITION-C. Models

PRODUCT SPECIFICATIONS

Power capacitors in general

REFRIGERATOR RM3862 MODEL SERIES PARTS LIST. Series MODEL RM3862

CHAMPION MARQUIS SPECIFICATIONS GUIDE UIDE FOR COMMERCIAL MODELS

Transcription:

DESRIPTION: Sensible cooling coil on the induced air inlet handles zone sensible load. Opposite side to controls location. luminum ripple fins (10 PI) and 1/" (13) copper tubes. and of coil connection is determined looking in direction of airflow (R shown). 0 ga. (1.0) galvanized steel construction. inclined opposed blade damper. 45 rotation. to close. 30 only. Ultra-high efficiency EM fan motor. EPI fan volume controller. 1/" (13) dual density fiberglass installation, exposed edge coated to prevent air erosion. Meets requirements of NP 90 and U 1. ccess panels top and bottom. Multi-point averaging diamond flow sensor. Discharge opening for flanged duct connection. Single point electrical connection. ow voltage enclosure for factory mounted DD controls. ontrols mounted as standard on R side as shown. size 30 ordered with controls (optional) is inverted and discharge duct hanging elevation will therefore change. Galvanized steel drip pan integral to sensible coil. OPTIONS: OI: q -Row q 4-Row q 6-Row q eft and coil connections. q ondensate Sensor. INER: q iber-free liner. q Perforated metal liner. q Solid metal liner. q Steri-liner. q Steri-liner w/perforated liner. ITERS: q Throwaway. q " (51) Pleated MERV 8. q " (51) Pleated MERV 13. q Ducted Return ilter Rack (See submittal 33SZ-R). SEDUE TYPE: Model 33SZ Basic DI. = NOM. - 1/8" (3) POERED IED TER TERMIN UNIT ONSTNT VOUME SENSIBE OOING (DOS) MODES: 33SZ, 33SZE ND 33SZ UNIT SIZE 30 (O PROIE) MUTI-POINT O SENSOR Electrical Motor Data Motor. P. * 30 Inlet 5, 6, 8 (17, 15, 03) OPTION ITER R OI 6" (15) B 6 1 (673) 11 (79) 40 1 4 (10) 7 (178) ONTROS EM 10/1/60 08/1/60 40/1/60 77/1/60 30 * 7.5 5.0 5.0 4.9 The EM is a variable horsepower motor. Refer to Selectworks Schedule. = ull load amperage (51) EETRI: q ontrols enclosure q Toggle disconnect switch. q N 90 line voltage enclosure. q N3 Remote line voltage enclosure. q Motor fusing. OTERS: q anger brackets. INDUED (15) I DRIVEST ooling oil I x I ONTROS 36 X 8 3 4 (914 X ) Page 1 of. or heat options; see page. DTE B SERIES SUPERSEDES DRING NO. 8-19 - 15 3300 1-3 - 14 33SZ-1 Row: 5 1 8 (130) 4 Row: 7 5 16 (6) 6 Row: 9 1 (41) 1/" (13) " (51) I D D oil O.D. Sweat onnections No. of Row, 4, & 6 30 7/8" () Outlet Discharge D x D 1 3 8 X 6 7 8 (314 X 175) B ilter 38 X 10 (965 X 54)

POERED IED TER TERMIN UNIT ONSTNT VOUME SENSIBE OOING (DOS) MODES: 33SZE ND 33SZ UNIT SIZE 30 (O PROIE) q ot ater oil Section Model 33SZ Standard eatures: oil section installed on unit discharge. 1/" (13) copper tubes. luminum ripple fins (10 PI). Sweat onnections: One row: 1/" (13) O.D. male solder. Two row: 5/8" (16) O.D. male solder. langed outlet duct connection. oil Rows: q 1-Row q -Row oil and onnections: (ooking in direction of airflow). q Right and (illustrated). Standard. q eft and. Optional. eating coil, sensible coil and controls enclosure orientation must all be specified separately. ONTROS DRIVEST ONTROS OT TER OI R OI 1" (305) J J D Outlet Duct x D 30 6 1 (673) 11 (79) 40 1 4 (10) 1 4 X 8 3 4 (610 X ) q Electric oil Section Model 33SZE Standard eatures: Unique hinged heater design permits easy access, removal and replacement of heater element without disturbing ductwork. oil installed on unit discharge. Insulated coil element wrapper. utomatic reset high limit cut-outs (one per element). Single point electrical connection for entire terminal unit. Electronic an Interlock Relay. langed outlet duct connection. ontrols mounted as standard on R side as shown. Terminals ordered with.. controls (optional) are inverted. Voltage: Single phase, 60 z. q 10V q 08V q 40V q 77V Three phase, 60 z. q 08V q 480V (4 wire wye). q 600V (dual point connection). q. SEDUE TYPE: ONTROS DRIVEST ONTROS EETRI ETER M K 1 7/8" (48) K M N Electric oil Options: q SR control (0 10 VD). q 4 0ma q with discharge temperature control. q Toggle disconnect (includes fan). q Door interlock disconnect switch. q Quiet contactors. N Page of. DTE B SERIES SUPERSEDES DRING NO 8-19 - 15 3300 1-3 - 14 33SZ-1 G Outlet Duct x G 30 6 1 (673) 11 (80) 40 1 4 (10) 16 3 8 (416) 10 1 8 (57 11 1 (9) 13 3 8 x 8 (340 x 03) q Main line fusing. q lass '' 80/0 Ni./h. wire. q Dust tight construction. q Manual Reset secondary thermal cut out. q Positive Pressure airflow switch.

DESRIPTION: Sensible cooling coil on the induced air inlet handles zone sensible load. Opposite side to controls location. luminum ripple fins (10 PI) and 1/" (13) copper tubes. and of coil connection is determined looking in direction of airflow (R shown). channel frame with 0 ga. (1.0) casing components. inclined opposed blade damper. 45 rotation. to close. Ultra-high efficiency EM, fan motor. EPI fan volume controller. ¾" (19) dual density fiberglass installation, exposed edge coated to prevent air erosion. Meets requirements of NP 90 and U 1. ccess panels top and bottom. Multi-point averaging diamond flow sensor. Discharge opening for flanged duct connection. Single point electrical connection. ow voltage enclosure for factory mounted DD controls. ontrols mounted as standard on R side as shown. Terminals ordered with controls (optional) are inverted and discharge duct hanging elevation will therefore change. Galvanized steel drip pan integral to sensible coil. ilter rame and disposable filter. OPTIONS: OI: q -Row q 4-Row q 6-Row q eft and coil connections. q ondensate sensor. INER: q iber-free liner. q Perforated metal liner. q Solid metal liner. q Steri-liner. q Steri-liner w/perforated liner. ITERS: q Throwaway. q " (51) Pleated MERV 8. q " (51) Pleated MERV 13. q Ducted Return ilter Rack (See submittal 33SZ-R). SEDUE TYPE: Model 33SZ Basic DI. = NOM. - 1/8" (3) POERED IED TER TERMIN UNIT ONSTNT VOUME SENSIBE OOING (DOS) MODES: 33SZ, 33SZE ND 33SZ UNIT SIZES: 40 ND 50 OPTION ITER R OI MUTI-POINT O SENSOR 40 50 Inlet 4, 5, 6, 8, 10 (10, 17, 15, 03, 54) 5, 6, 8, 10, 1 (17, 15, 03, 54, 305) Page 1 of. or heat options; see page. DTE B SERIES SUPERSEDES DRING NO. 1-3 - 14 3300 NE 33SZ- I DRIVEST VVE ONTROS 1 (79) 6" (15) B 6 (660) Electrical Motor Data Motor. P. * 36 (914) 41 (1041) EM 3 1 (89) 5 (17) 10/1/60 08/1/60 40/1/60 77/1/60 40 * 6.5 4. 4. 4. 50 * 9.5 6.4 6. 6.0 The EM is a variable horsepower motor. Refer to Selectworks Schedule. = ull load amperage EETRI: q ontrols enclosure q Toggle disconnect switch. q N 90 line voltage enclosure. q N3 Remote line voltage enclosure. q Motor fusing. OTERS: q anger brackets. INDUED ooling oil I x I INGED INE VOTGE ONTROS 1 1/" (38) - 31 X 15 (787 X 381) Row: 5 1 8 (130) 36 x 15 (914 X 381) 4 Row: 7 5 16 (6) 6 Row: 9 1 (41) D Outlet I Discharge D x D " 9 1 8 X 10 1 4 (3 X 60) 13 1 8 X 11 1 4 (3 X 86) B D ilter 33 X 16 (838 X 406) 38 X 16 (965 X 406) oil O.D. Sweat onnections 40 50 No. of Row, 4, & 6 7/8" ()

POERED IED TER TERMIN UNIT ONSTNT VOUME SENSIBE OOING (DOS) MODES: 33SZE ND 33SZ UNIT SIZES: 40 ND 50 q ot ater oil Section Model 33SZ Standard eatures: oil section installed on unit discharge. 1/" (13) copper tubes. luminum ripple fins @ 10 PI. Sweat onnections: 40 one row: 1/" (13) O.D. male solder. ll others: 7/8" () O.D. male solder. langed outlet duct connection. oil Rows: q 1-Row q -Row oil and onnections: (ooking in direction of airflow). q Right and (illustrated). Standard. q eft and. Optional. eating coil, sensible coil and controls enclosure orientation must all be specified separately. DRIVEST OT TER OI R OI D 1" (305) " Outlet Duct x D 40 36 (914) 16 X 15 (406 X 381) 50 6 (660) 41 (1041) 4 X 15 (610 X 381) q Electric oil Section Model 33SZE Standard eatures: Unique hinged heater design permits easy access, removal and replacement of heater element without disturbing ductwork. oil installed on unit discharge. Insulated coil element wrapper. utomatic reset high limit cut-outs (one per element). Single point electrical connection for entire terminal unit. Electronic an Interlock Relay. langed outlet duct connection. ontrols mounted as standard on R side as shown. Terminals ordered with.. controls (optional) are inverted and discharge duct hanging elevation will change. Voltage: Single phase, 60 z. q 10V q 08V q 40V q 77V Three phase, 60 z. q 08V q 480V (4 wire wye). q 600V (dual point connection). q. DRIVEST K M EETRI ETER 15 1/4" (387) M K G Outlet Duct x G 40 36 (914) 15 1 (394) 1 (64) 10 1 4 x 10 1 (60 x 67) 50 6 (660) 41 (1041) (559) 4 (10) 14 1 4 x 11 3 4 (36 x 98) Electric oil Options: q SR control (0 10 VD). q 4 0ma q with discharge temperature control. q Toggle disconnect (includes fan). q Door interlock disconnect switch. q Quiet contactors. " q Main line fusing. q lass '' 80/0 Ni./h. wire. q Dust tight construction. q Manual Reset secondary thermal cut out. q Positive Pressure airflow switch. SEDUE TYPE: Page of. DTE B SERIES SUPERSEDES DRING NO. 1-3 - 14 3300 NE 33SZ-

POERED IED TER TERMIN UNIVERS DUTED RETURN ITER RK ESSORY ODE DRR MODE SERIES: 33SZ 5 1/" (140) ITER RK DOOR P OPENING ON SIDE ND BOTTOM T O MOUNTING NGE MOUNTING NGE DESRIPTION: The DRR Ducted Return ilter Rack is an optional accessory for the an Powered hilled ater Terminal Model Series 33SZ. The accessory is required for ducted inlet applications where a filter is also required and ease of accessibility is required. The Ducted ilter onnection features a filter rack, which accommodates a standard or " (51) optional filter. actory mounted on the induced air inlet of the draw through water coil section. piano-hinged door flap with latch on the side and bottom of the unit accessory allows for easy removal and replacement of the filter. The accessory is provided with a nominally sized duct connection collar. Inlet x ilter x 30 36 x 8 3 4 (914 x ) 38 X 10 (965 X 54) 40 31 x 15 (787 x 381) 33 X 16 (838 X 406) 50 36 x 15 (914 x 381) 38 X 16 (965 X 406) SEDUE TYPE: DTE B SERIES SUPERSEDES DRING NO. 8-19 - 15 33SZ - 11-15 33SZ-R