The problems as we saw them were;

Similar documents
Contact Person(s) : Anna Berne APPLICATION

URANIUM IN SOIL. Analytical Procedure (2 GRAM SAMPLE) 1. SCOPE

Method NumberUSTUR 150

TKI CU01 V-1.0_EN Cu separation from irradiated targets 01/12/10

enable measurement. This method separates these isotopes effectively.

SAFETY NOTE: Before beginning this procedure, read all of the Material Safety Data Sheets for the chemicals listed in Section 5 of this procedure.

Pu and Np-237 in seawater samples Version /03/14. Summary

(CATION EXCHANGE AND LN RESIN, WITH VACUUM BOX SYSTEM)

TECHNETIUM-99 IN SOIL

NICKEL-63/59 IN WATER

TECHNETIUM-99 IN WATER

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

1.1. This is a method for the separation and measurement of 228 Ra in water via its beta emitting 228 Ac daughter.

of numerous north-south trending Miocene and volcanic centres and lava flows. For

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

AGE DETERMINATION OF HIGHLY ENRICHED URANIUM

Uranium from water sample

Determination of Ni isotopes in nickel material from the Rossi reactor

Preparation and characterisation of a sorbent suitable for technetium separation from environmental matrices

ICP/MS Multi-Element Standards

Rapid Analytical Methods for Determination of Actinides

Rapid Methods for the Determination of Sr-90 in Steel and Concrete Samples

THORIUM, PLUTONIUM, AND URANIUM IN WATER

Rapid separation of uranium and plutonium by extraction chromatography for determination by thermal ionisation mass spectrometry

TECHNETIUM-99 IN WATER

Rapid Separations. Activity Radioactive Solutions. Lawrence Jassin Eichrom Technologies LLC March 3, 2008 Pittcon 2008

Tex-620-J, Determining Chloride and Sulfate Contents in Soil

Test Method: CPSC-CH-E

ANALYTICAL TASK EXPERIMENTAL PROCEDURE

Care and Use Manual for Supelco Multi-Layer Silica Gel Column and Dual-Layer Carbon Reversible Column

Rapid Determination of Ra-226 in Environmental Samples

Journal of Analytical Atomic Spectrometry

New sequential separation procedure for Sr, Nd and Pb isotope ratio measurement in geological material using MC-ICP-MS and TIMS

Atom exchange between aqueous Fe(II) and structural Fe in clay minerals

Rapid Detection of Americium-241 in Food by Inductively-Coupled Plasma Mass Spectrometry

Sample Analysis Design Polyatomic Interferences

Quantitative analysis of Na, K and Ca in milk and yogurt using the MH-5000 Ultra Compact Elemental Analyzer

Operating Instructions for Ammonium ISE Specifications

MM800 (a) Ion Exchange and ICP/MS of Uranium in Water. 1.0 Scope and Application

Eichrom Technologies, Inc. Analytical Procedures Rev. 1.5 February 10, 2005 Page 1 of 9

Revised material in Section 4, Analytical Chemistry

Experiment 14 - Qualitative Analysis

Determination of trace anions in concentrated hydrofluoric acid

Matrix and High Loading Effects on Eichrom Resins. Dan McAlister and Phil Horwitz Eichrom Workshop October 31, 2012

Section B: Some Essential Background Chemistry

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Savillex Technical Note Performance of the DST-1000 Acid Purification System

ASCORBIC ACID METHOD FOR PHOSPHORUS DETERMINATION

Chromatographic Methods of Analysis Section - 4 : Ion Exchange Chrom. Prof. Tarek A. Fayed

Automation of the radiochemical procedures for the sequential separation of radionuclides

Soil-To-Plant Transfer Factor of Uranium by Measuring Naturally Occurring Uranium at Trace Levels in Plants and Soils by ICP-MS -9105

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Supplementary Materials for

Prelab Reading Assignment: Laboratory Techniques in Organic Chemistry, 4 th Ed. Chapter 19

OESTREICH LAB CHIP PROTOCOL

LSC for Quality Control of 99m TC Eluate from 99 Mo- 99m Tc Generator

CHEM Practice to be done before the lab. Experiment 9 Introduction to Volumetric Techniques II. Objectives

EXPERIMENT 8 Determining K sp

A Rapid Method for Determination of Uranium, Americium, Plutonium and Thorium in Soils Samples. Serdeiro, N.H. and Marabini, S.

Sample Analysis Design PART II

Handbook of Inductively Coupled Plasma Spectrometry

Contact Person : Marie Lawrence APPLICATION

Method Number USTUR 510

To explore solubilities and reactivities of different metal ions. To identify ions present in unknown solutions using separation methods.

DO NOT CIRCULATE LOS ALAMOS SCIENTIFIC LABORATORY LA-8399 PERMANENT RETENTION REQUIREDBY CONTRACT. Separation of Trace Uranium from

RARE EARTH FLUORIDE MICROPRECIPITATION

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

(!Z. Los Alamos NATIONAL LA BOR ATO R COPY - REPRODUCTION LA-UR

and their Use in Food Methods

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

Supporting Information

[ST 2012, 2 nd Revision] 2.11 Test methods for rubber pacifiers Material test Cadmium and lead Preparation of test solutions [For a

URANIUM AND THORIUM-ISOTOPES RADIOCHEMICAL SEPARATION AND QUANTIFICATION OF NORM SAMPLES BY ALPHA-SPECTROMETRY

A Comparison of EPA Method and ASTM D6239 for Uranium in Hard Water Matrices. Robert L. Metzger & Pierre Pouquette

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Chemical Foundations Part 2

Cl 2(g) + NaCl + H 2 O. light. 2Cl. Once formed, the chlorine radical can react with the heptane as shown below: + Cl

Chromatography: Thin-Layer Chromatography (TLC) & Column Chromatography

Flushing Out the Moles in Lab: The Reaction of Calcium Chloride with Carbonate Salts

Sodium Chloride - Analytical Standard

Sample Analysis Design PART III

Strike-slip Faults Mediate the Rise of Crustal-Derived Fluids and Mud Volcanism in

Journal of Chemical and Pharmaceutical Research, 2014, 6(5): Research Article

Bulk Analysis of Environmental Swipe Samples

Determination of 126 Sn in nuclear wastes by using TEVA resin

This document consists of 11 printed pages, 1 blank page and a Data Sheet for Chemistry.

RediSep Rf C18 Flash Column Loading Techniques

Preparing Extension Products for Electrophoresis

USGS Troy WSC Laboratory Inductively Coupled Plasma- NH4Cl Soil Extracts SOP 425 Jordan Road Rev. No. 2.0 Troy, NY Date: 03/16/2012 Page 1 of 7

Determination of 210 Pb and 210 Po in Water Samples

Journal of Earth Science, Vol. 29, No. 1, p , February 2018 ISSN X Printed in China

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certifi cate of Education Advanced Subsidiary Level and Advanced Level

PAR Method Method to 2.0 mg/l Pb TNTplus 850

Rapid Method for 226 Ra in Urine Samples

Working in the Chemistry Laboratory

Experiment 12H, Parts A and B

USGS Troy WSC Laboratory Ion Chromatography SOP EPA 300.0, Rev Jordan Road SOP. No. 1 Rev. No. 1.7 Troy, NY Date 01/25/18 Page 1 of 7

ProPac WCX-10 Columns

GSA DATA REPOSITORY

Separation and Identification of Metal Ions

Transcription:

My name is Michael Murphy and I work in the isotope laboratory in the Department of Geology, University College Dublin. I am going to talk to you about rubidium, strontium, samarium and neodymium elemental separation but before doing so I would like to deal briefly with the background to elemental separation and why it is necessary for us. In the laboratory we have a Micromass 30 Thermal Ionisation Mass Spectrometer (TIMS). We are interested in determining the isotopic composition of Sr, Rb, Nd and Sm from various geological samples on the TIMS. However, before we can do this it is necessary to make the sample as elementally pure as possible. This is important as an impure sample will result in a very poor ion yield and beam stability in the mass spectrometer and hence a poor analysis. Isobaric interference must also be minimized for Sr & Nd isotopic analysis. This is where an isotope is common to two elements such as Rb87 & Sr87, as the mass spectrometer cannot discriminate between isotopes of the same atomic mass it is necessary to remove them chemically prior to analysis. In the laboratory, as in most geochemical isotope laboratories, we have traditionally performed this separation procedure using ion exchange columns. Ion exchange techniques were developed in the 1950 s & 60 s and details published by a number of workers including F.W.E. Strelow who published this paper in 1960. In it he published this table of equilibrium distribution coefficients (Kd) for 43 cations in various concentrations of hydrochloric acid. I have highlighted the coefficients for rubidium, strontium and the rare earth elements lanthanum and cerium. The larger the coefficient, the greater the affinity the resin has for the cation. Also the larger the ratio of the coefficients of two cations, the easier it is to separate them using an ion exchange column. You can see from this table that the weaker the acid is, the greater the equilibrium distribution coefficient (Kd) is. Hence for any particular element, a weak acid solution results in much more acid being required to elute the cation from an ion exchange column than a strong acid solution of the same cation. For our traditional ion exchange separations we used Bio-Rad AG50W-X-12 resin and a 2.5 M HCl sample solution. We found we needed 5 grams of resin in order to give us an adequate cation separation for a sample weight of 100 milligrams maximum. This resulted in 94 mls of 2.5 M HCl being required to pass through the column in order to elute Sr, with the Sr fraction being collected in the final 27 mls of 2.5M HCl. In order to elute Sm & Nd, a further 55 mls of 4M HNO3 was required with Sm & Nd being collected in the final 35 mls. The Sr fraction was put through the ion exchange resin again in order to improve the separation. The Sm & Nd fraction was then evaporated down, converted to chloride and put through an ion specific resin with the same active ingredient as

Ln resin but on a different support, in order to separate Sm from Nd. A larger column and hence more acid was required than the Ln column we presently use and which I will describe shortly. When we in Dublin first learned of Eichrom specific ion resins and read this paper (overhead of the first page of the paper) by Christian Pin and his colleagues we were very interested in the resins and in trying to get the technique to work. This paper was followed a few years later by this paper (overhead) also by Christian Pin on ion specific resins. The first paper describes the use of Eichrom Sr resin to separate Sr from silicate samples and TRU resin to separate the light rare earth elements as a group. The second paper describes the use of Ln resin to separate the light rare earth elements (LREE) individually, in particular Nd from Sm. These resins as they have a very large equilibrium distribution coefficient for one or a small group of cations offered the possibility of; (1) giving better separation of the required element from the dissolved rock solution and hence a more accurate and reproducible analysis on the TIMS (2) a lot less acid required to perform the separation, (3) lower blank as less acid was required & the resin would be discarded after each separation (4) a faster separation procedure The problems as we saw them were; (1) greater expense as the resin and column was discarded after each separation, (2) as the columns had to be made up each time it would possibly take longer to make a separation, (3) Sr resin is not entirely specific to Sr but also retains Ba and Pb in dilute HNO3. Overall we have managed to realize the advantages as we saw them and are very happy with the results we have obtained. This is especially true for Nd isotopic analysis where the success rate is much higher than previously obtained suggesting that a purer Nd fraction is obtained with the specific ion resins. When we decided to try and use the Eichrom resins we had to decide at first what columns to use and how much resin. We made up a chemical solution with all the major elements in the approximate concentrations you would expect to find in a geochemical sample. We then calibrated the columns with this solution and using an inductively coupled plasma (ICP) spectrometer to detect the elements of interest and adjusted the columns and acid as was neccessary.

I would now like to describe exactly how we perform the elemental separations using Sr, TRU & Ln resins. In order to keep costs down we decided to use a 5 ml pipette tip as a column instead of purchasing ready made columns. We cut off the top of the pipette tip, and push a porous polyethylene frit, 2.5 mm diameter down to the bottom of the tip as shown on the slide. The frit material was bought in a sheet from Bel-Art, USA, has a nominal pore size of 70 um and is 3.2 mm thick. This frit is used to keep the resin in place. Next we add in 100 mg of resin, wet it with 0.05 M HHO3, remove any air bubbles by agitating it with a glass rod and when the dilute nitric acid has flowed through the resin, we push a polyethylene frit, 6.5 mm diameter onto the top of the resin. This frit stops the resin from being disturbed when sample or acid is added to the column and is very important to ensure a smooth flow rate and good separation. The Sr and TRU columns are made in this manner. However for TRU resin as we use a finer grade resin (50-100 um instead of 100-150 for Sr) we found we had to use a 4 mm frit at the bottom of the column in order to give an adequate flow rate. This gives a column length of 20 mm for Sr & 14 mm for TRU resin. (I will then show a slide of both columns in the column holder and point out the support on the TRU resin column holder.) The columns are washed with 3-4 mls 0.05M HNO3 to remove any cations present, preconditioned with 1M HNO3 and are then ready for use. The Ln resin can be reused, as indicated by Christian Pin. Hence we decided to use Bio-Rad columns as they come fitted with a frit and have room for 600 mg of resin and 10 mls of a reservoir of acid. We load the resin as a slurry, remove any air bubbles, & fit a 9 mm porous frit to the top of the resin. (Slide of full column & column holder). The samples following standard HF+HNO3 acid digestion, are evaporated to dryness, dissolved in 6M HCL and finally in 2 mls of 1M HNO3. For the first stage in the separation procedure, the Sr columns are put on top of the TRU columns as shown above. The dissolved sample is put directly on the Sr resin top frit and the solution flows through the resin where Sr is retained, out at the bottom of the column, through the TRU resin where the LREE are retained and the remaining elements including rubidium, flow out at the bottom where they are collected if Rb is required. 1 ml of 1M HNO3 is added to the Sr resin to wash it and the solution again collected. The columns are then disassembled so that the Sr & LREE can be eluted separately. The Rb has to be separated from the collected fraction using the standard cation exchange resin as described earlier. Perhaps Eichrom will develop a Rb specific resin just for this purpose!!

Sr Elution 1. Wash the Sr.Spec columns with 3 mils of 8M HNO 3 and discard eluant. 2. Add 2 mils of 0.05M HNO 3 and collect. This fraction has to be further purified to remove Ba which can seriously affect the analysis of Sr on the mass spectrometer by reducing the yield of ions. Hence the purification process is repeated as described below. 3. Evaporate down and redissolve samples in 1 mil of 1M HNO 3. 4. Wash columns with 3 mils of 0.05M HNO 3 and discard. 5. Precondition columns with 3 mils of 1M HNO 3 and discard. 6. Load the semi-purified Sr fractions on the same columns as before ensuring that exactly the same column is used for each sample to avoid cross contamination and discard eluent. 7. Add 1 mil 1M HNO 3 and discard. 8. Add 3 mils of 8M HNO 3 and discard. 9. Add 2 mils of 0.05M HNO 3 and collect Sr. 10. Dry down the Sr fractions which are then ready for analysis on the mass spectrometer. This gives a total acid volume of 12 mls for a double stage separation as compared to 94 mls for a single stage separation using the cation exchange resin. Elution of LREE. 1. Wash the TRU.Spec resin with 2 mls 1.0M HNO3 and discard. 2. Then wash the TRU.Spec resin with 0.25 ml 0.05M HNO3 and discard. This is to change the acid on the resin to 0.05M HNO3 so that the 1M HNO3 will not be washed onto the LN column as this would result in the REE being washed off again very quickly and lost. 5. Position the TRU.Spec columns on top of the LN columns so that the REE will be washed directly from one to the next. 6. Elute the REE with 1.75 mls 0.05M HNO3. 7. Dismantle the columns.

The light rare earth elements are hence separated using 4 mls of dilute nitric acid compared to 55 mls of 4 M HNO3 for the traditional ion exchange resin column. Elution of Nd & Sm from Eichrom LN resin column. 1. Wash with 4 X 1 ml 0.2M HCl and discard. 2. Wash with 10 mls 0.2M HCl and discard. 3. Position Nd beakers under columns. Elute Nd with 2.5 mls 0.3M HCl. 4. Wash columns with 3 mls 0.5M HCl and discard. 5. Position Sm beakers under columns. Elute Sm with 2.5 mls 0.5M HCl. 6. Evaporate down the Sm & Nd fractions. They are now ready for analysis on the mass spectrometer. 7. Wash the LN columns with a bowl full of 6M HCl, followed by ~ 5 mls of 0.2M HCl. Add another ~5 mls 0.2M HCl and cap the columns top and bottom in order to prevent the columns from drying out. Where possible the columns should not be left uncapped overnight. It takes approximately a half a working day to make a set of six Sr and Tru columns. The complete chemical separation of Sr, Sm & Nd can now be done in one working day as compared to three days previously. This is mainly due to less acid being required. The fact that the solution drips directly from one column to the next without the need to evaporate down or change the anion, is the other major time and labour saving feature.