6th International Conference on Information Engineering for Mechanics and Materials (ICIMM 2016)

Similar documents
EEE4106Z Radiation Interactions & Detection

SILVER NEUTRON ACTIVATION DETECTOR FOR MEASURING BURSTS OF 14 MEV NEUTRONS

Gamma and X-Ray Detection

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Chapter V: Interactions of neutrons with matter

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

Nuclear Physics and Astrophysics

Radioactivity and Ionizing Radiation

1.4 The Tools of the Trade!

The interaction of radiation with matter

Today, I will present the first of two lectures on neutron interactions.

Nuclear Reactions A Z. Radioactivity, Spontaneous Decay: Nuclear Reaction, Induced Process: x + X Y + y + Q Q > 0. Exothermic Endothermic

Physics Important Terms and their Definitions

General Overview of Gas Filled Detectors

Semiconductor Detectors

2. Which of the following statements help(s) to explain why gas can fill the vessel containing it completely while liquid cannot?

B. Rouben McMaster University Course EP 4D03/6D03 Nuclear Reactor Analysis (Reactor Physics) 2015 Sept.-Dec.

Neutron Detection. n interactions with matter n detection High/low energy n detectors

Compton suppression spectrometry

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Neutron Interactions Part I. Rebecca M. Howell, Ph.D. Radiation Physics Y2.5321

The Monte Carlo Simulation of Secondary Electrons Excitation in the Resist PMMA

ATOMIC WORLD P.1. ejected photoelectrons. current amplifier. photomultiplier tube (PMT)

Total probability for reaction Yield

Optics Definitions. The apparent movement of one object relative to another due to the motion of the observer is called parallax.

Sample Examination Questions

There are 82 protons in a lead nucleus. Why doesn t the lead nucleus burst apart?

Radioactivity. Lecture 6 Detectors and Instrumentation

For more sample papers visit :

PhysicsAndMathsTutor.com 1

Introduction. Principle of Operation

GaN for use in harsh radiation environments

Radioactivity. General Physics II PHYS 111. King Saud University College of Applied Studies and Community Service Department of Natural Sciences

DETECTORS. I. Charged Particle Detectors

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

Bolometry. H. Kroegler Assciazione Euratom-ENEA sulla Fusione, Frascati (Italy)

Preview from Notesale.co.uk Page 4 of 35

The Attenuation of Neutrons in Barite Concrete

Neutron Sources Fall, 2017 Kyoung-Jae Chung Department of Nuclear Engineering Seoul National University

Boron-based semiconductor solids as thermal neutron detectors

Quality Assurance. Purity control. Polycrystalline Ingots

Neutron Metrology Activities at CIAE (2009~2010)

1.5. The Tools of the Trade!

6 Neutrons and Neutron Interactions

CVD Diamond History Introduction to DDL Properties of Diamond DDL Proprietary Contact Technology Detector Applications BDD Sensors

1 P a g e h t t p s : / / w w w. c i e n o t e s. c o m / Physics (A-level)

Neutron interactions and dosimetry. Eirik Malinen Einar Waldeland

Interaction of charged particles and photons with matter

Interaction of Particles and Matter

Chapter 11: Neutrons detectors

Ch Radioactivity. Henry Becquerel, using U-238, discovered the radioactive nature of elements in 1896.

Nuclear Properties of Carbon Nanotubes for Fast Neutron Detection

He-3 Neutron Detectors

L 36 Modern Physics [3] The atom and the nucleus. Structure of the nucleus. The structure of the nucleus SYMBOL FOR A NUCLEUS FOR A CHEMICAL X

Detection and measurement of gamma-radiation by gammaspectroscopy

Name Date Class NUCLEAR RADIATION. alpha particle beta particle gamma ray

APPLIED RADIATION PHYSICS

Radioactivity. General Physics II PHYS 111. King Saud University College of Applied Studies and Community Service Department of Natural Sciences

PhD Qualifying Exam Nuclear Engineering Program. Part 1 Core Courses

Nuclear Physics 2. D. atomic energy levels. (1) D. scattered back along the original direction. (1)

ORTEC. Review of the Physics of Semiconductor Detectors. Interaction of Ionizing Radiation with Semiconductor Detectors. Heavy Charged Particles

Calculating standard captured spectra of formation elements

Chapter V: Cavity theories

Introduction to Ionizing Radiation

Chapter 4 Scintillation Detectors

Chapter 30 Nuclear Physics and Radioactivity

Chemical Engineering 412

Thermal Radiation Studies for an Electron-Positron Annihilation Propulsion System

Spectroscopy on Mars!

L 37 Modern Physics [3] The atom and the nucleus. Structure of the nucleus. Terminology of nuclear physics SYMBOL FOR A NUCLEUS FOR A CHEMICAL X

GCSE PHYSICS REVISION LIST

Radiation (Particle) Detection and Measurement

Absorption and Backscattering ofβrays

CALIBRATION OF SCINTILLATION DETECTORS USING A DT GENERATOR Jarrod D. Edwards, Sara A. Pozzi, and John T. Mihalczo

Sensors and Detectors Part 2

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

Chapter Four (Interaction of Radiation with Matter)

References and Figures from: - Basdevant, Fundamentals in Nuclear Physics

Interaction of Ionizing Radiation with Matter

Progress Report on Chamber Dynamics and Clearing

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

Chapiter VII: Ionization chamber

PHYSICS FOR RADIATION PROTECTION

Nuclear Physics and Nuclear Reactions

Basics of Geophysical Well Logs_Porosity

CHARGED PARTICLE INTERACTIONS

Energy loss of alpha particles - Prelab questions

High-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy

Scintillators General Characteristics

Basic physics Questions

Polarization Correlation in the Gamma- Gamma Decay of Positronium

β and γ decays, Radiation Therapies and Diagnostic, Fusion and Fission Final Exam Surveys New material Example of β-decay Beta decay Y + e # Y'+e +

MEASUREMENT AND DETECTION OF RADIATION

Neutral beam plasma heating

e - Galvanic Cell 1. Voltage Sources 1.1 Polymer Electrolyte Membrane (PEM) Fuel Cell

Neutron Log. Introduction

Characterization of 3D thermal neutron semiconductor detectors

Contents. Charged Particles. Coulomb Interactions Elastic Scattering. Coulomb Interactions - Inelastic Scattering. Bremsstrahlung

Transcription:

6th International Conference on Information Engineering for Mechanics and Materials (ICIMM 2016) Design of Compensated Thermal Neutron Detector Based on He-3 Tube of SiC Micro-structure Jianlu Wu1, Hui Guo1, Xiaoyan Tang1, Yimen Zhang1, Yimeng Zhang1, Yuming Zhang1 1.School of Microelectronics, Xidian University, Xi an, 710071, China Email: wjl6213224@qq.com Keywords: silicon carbide; micro-structure; He-3 tube; thermal neutron; detector Abstract. A design scheme for compensated thermal neutron detector based on He-3 tube of SiC micro-structure is proposed herein in order to improve the detection sensitivity of the thermal neutron detector and then to improve the detection precision. Firstly the physical foundation analysis of thermal neutron detector with the silicon carbide (SiC) micro-structure is given herein and it is pointed out that the instrument response basically reflects the tiny space of stratum full of fluid; secondly, the response equation of He-3 Tube structure of the neutron detector is given and then the functional block diagram for compensated neutron detector is designed based on it; finally, the performance of compensated thermal neutron detector based on He-3 tube of SiC micro-structure proposed herein is effectively tested through experiment. Introduction Since the 21st century, with the vigorous development of semiconductor industry, the rapid advance of growth process of semiconductor material, devices fabrication process and the technology of large scale integrated circuit, as well as the continuous decrease in production and processing cost have laid an important foundation for the profound research on the semiconductor neutron detector based on micro-structure. Planar semiconductor neutron detector consists of semiconductor diode and coating for conversion of surface neutron, and due to the problems about self-absorption of applied conversion layer, the detection efficiency of the planar semiconductor neutron detector is relatively low (detection efficiency for the thermal neutron less than 5%). Muminov et al had firstly put forward the concept of semiconductor neutron detector based on micro-structure in 1987 and hence opened up a new field where the micro-structure semiconductor is applied to the neutron detection. Compared with gas detector, semiconductor is obviously small in volume and the detector made from it can be used for the neutron intensity measurement in narrow space area, and its detection efficiency of thermal neutron can exceed 20%. In case the method of multi-layer stacking is utilized, its detection efficiency of thermal neutron can reach above 50%. Thanks to these advantages of semiconductor neutron detector based on micro-structure, it plays an important role in the measurement of neutron flux density in weak neutron radiation field, the neutron radiation detection on plutonium (uranium) material and spent fuel, the neutron individual dosimetry and neutron scattering measurement and such fields. For this purpose, a design methods for compensated thermal neutron detector based on He-3 tube of silicon carbide (SiC) micro-structure is proposed herein. The physical foundation analysis of thermal neutron detector with the SiC micro-structure, operating principle of compensated neutron instrument and response equation of He-3 tube structure of neutron detector are given herein, too, and finally the performance of compensated thermal neutron detector based on He-3 tube of SiC micro-structure is effectively tested through experiment. Structural design of detector Physical foundation for thermal neutron detector based on SiC micro-structure 2016. The authors - Published by Atlantis Press 691

The compensated neutron detector adopts SiC micro-structure and is provided with 20 Curie Am Be neutron source with the energy of about several million electron volts. It generates 4 107 fast neutrons per second which inject into the stratum and have a series of nuclear reaction with substance in the stratum. These include: inelastic scattering of fast neutron, excitation of fast neutron to the nucleus and the elastic scattering and deceleration of fast neutron. The energy of the fast neutron gradually decrease due to a series of inelastic collision and elastic collision, and finally when the neutron energy is under the same thermal equilibrium state as the atom in the stratum, the neutron will not decelerate any more. The neutron under this energy state is called thermal neutron. The energy of standard thermal neutron is: 0.025ev with a speed of 2.2 105 cm/s. According to the collision theory, the energy loss in neutron in collision is related to the mass and angle of incidence of the substance to be collided, and if the neutron collides with the substance with the mass equivalent to it (elastic collision), the energy loss in neutron is the highest. In the stratum, the hydrogen atom is of the mass very close to the neutron, and therefore the deceleration capacity of the fast neutron in the stratum mainly depends on the hydrogen content of the stratum, and the stronger the macroscopic deceleration capacity of the stratum, the small the deceleration length. Upon several collisions, the fast neutron will be decelerated and the energy from the average one of 5.6MeV of the fast neutron reduces to 0.025eV of the thermal neutron. The stratum pore is a ting space full of fluid, and the water and hydrocarbon contain hydrogen atom, and the oil-free stratum and ore-rock barely contains hydrogen. Therefore, the instrument response basically reflects the tiny space of stratum full of fluid, namely the porosity. He-3 tube structure of neutron detector Currently, domestic and overseas compensated neutron logging instruments adopt He-3 proportional counter tube as the thermal neutron detector which outputs negative polar electric impulse under normal operating condition, and the impulse amplitude is continuously distributed within the range of 0.5uv--1.5mv; if the impulse width is less than 5us, it is a random signal, and the outline structure of He-3 tube is cylindrical and there is theatrically infinitesimal metal wire on the axis of the cylinder in which is full of many He-3 gases with atmospheric pressure, and the range of atmospheric pressure is related to the sensitivity. The response equation for its neutron detection is as follows: He 3 + n 1 T + P + 0. 764Mev (1) 2 o The characteristics of neutron He-3 tube detector are: (1) simple structure; (2) resist high-voltage electricity impact, but not the physical stress impact; (3) infinite load; (4) weak output signal required to be shielded carefully; (5) only sensitive to thermal neutron, but not the neutron of other energies. Operating principles of compensated neutron instrument These thermal neutrons partly enter the detector and collide with the He-3 nuclear to induce nuclear reaction and generate H3 (tritium) proton which makes part He-3 ionization to generate electriferous ion and electron, and under the effect of high voltage electric field, the electron moves to the anode to generate a negative impulse which is magnified and recorded by the electronic circuit, and the quantity of the neutrons received by the detector directly reflects the quantity of the hydrogen atom in the stratum. Therefore, the downhole cartridge consisting of He-3 detector and its electronic circuit can be used to measure the hydrogen content in the stratum. The operating principle block diagram for compensated neutron instrument designed is shown in Fig. 1. 692

High voltage in in Detector Detector Low voltage Amplifier Amplifier Discriminator Discriminator Frequency divider Frequency divider Reshaping output Reshaping output out out High voltage Fig. 1 Block Diagram for Operating Principles of Compensated Neutron Instrument Suppressing methods for circuit disturbance of compensated neutron instrument include: (1) short circuit between circuit ground wire and the instrument framework. (2) Amplifier shielding case grounding. (3) Connect instrument and the earth with long conductor, which has significant effect on the unknown disturbance, especially in the process of instrument heating. (4) Thin film alloy sheet is used as the shielding case to completely cover part pre-amplifying circuit so as to suppress most disturbances. (5) Cleaning the entrance welding points of the instrument, detector and high voltage amplifier can suppress the persistent disturbance. Capacitance is added between circuit ground wire and the instrument framework, which can suppress the disturbance in instrument logging. The capacity is between 1 microfarad to 4.7 microfarads. Performance test The thermal neutron detector is remarkably characterized by the high intrinsic detection efficiency of the thermal neutron, compared with the traditional semiconductor neutron detector. Table 1 compares the performance of the thermal neutron detector herein and that of the traditional planar detector when the groove clearance and width are 5 m m and 15 m m respectively and the depth is 200 m m (the area of the sensitive region is 1cm2). The detection efficiency in Table 1 refers to the detection efficiency of thermal neutron when the system discrimination threshold is 300 kev. Table 1 shows that the existence of three-dimensional structure greatly enlarges the area of contact between the semiconductor material and neutron conversion material of the thermal neutron detector herein, and meanwhile greatly enlarges the volume of neutron conversion materials for filling. Therefore, the intrinsic detection efficiency of thermal neutron detector herein is essentially improved (compared with the planar detector, its detection efficiency is improved 9.2 times). Table 1 Effect of Structure on Detection Efficiency The thermal neutron detector herein belongs to semiconductor detector and inherits the advantage that the traditional semiconductor detector neutron is strong in gamma ray discrimination. Neutron to gamma ray rejection ratio is defined as follows: n( En) n γ = (2) γ ( Eγ ) n Where, ( En) and γ ( E γ ) are detection efficiencies respectively for the neutron with energies E E n of and γ and the γ ray for the detector. value is also related to the system discrimination threshold setting. Method of Monte Carlo simulation is adopted to obtain the 693

detection efficiencies of two types of detectors for 137Cs and 662keV gamma rays in Table 1, of which the interaction of photon with materials is described with the Penelope physical model. The total thicknesses of silicon slices of two types of detectors are 0.5mm. When the discrimination threshold is 300 kev, the of the thermal neutron detector herein for the thermal neutron and 3 662keV gamma ray of 137Cs source is up to 4.1 10, 23.7 times more than that of the planar detector. Change curve of with the discrimination threshold is shown in Fig. 2. Fig. 2 Change Curve of Neutron to Gamma Ray Rejection Ratio Fig.2 shows, when the values of discrimination threshold are same, the neutron detector herein is higher than that of value of the thermal of traditional planar detector, and the larger the discrimination threshold, the faster the increase speed of the value of the thermal neutron detector herein than the traditional planar detector. The experiment results verify the effectiveness of proposed thermal neutron detector. Conclusion A design scheme for compensated thermal neutron detector based on He-3 tube of SiC micro-structure is proposed herein and the theoretical foundation for the thermal neutron detector with silicon carbide (SiC) micro-structure is analyzed, the response equation of He-3 tube structure of neutron detector is given based on it and the block diagram for principle design of compensated neutron instrument is given herein, too, and then it is verified through experiment. Sand algorithm is simply verified through experiment during the period of design, and future research will focus on how to apply it to the actual detection more effectively. Reference [1] Zakharov L E, Gorelenkov N N, White R B, et al. Ignited spherical tokamaks and plasma regimes with LiWalls[J]. Fusion Engineering & Design, 2004, 72(1 3):149-168. [2] Bresnehan M S, Hollander M J, Wetherington M, et al. Prospects of direct growth boron nitride films as substrates for graphene electronics[j]. Journal of Materials Research, 2013, 29(3):459-471. [3] Blaich T, Elze T W, Emling H, et al. A large area detector for high-energy neutrons[j]. Nuclear Instruments & Methods in Physics Research, 1992, 314(1):136-154. [4] Barrett K, Bragg-Sitton S. Advanced LWR Nuclear Fuel Cladding System Development Trade-Off Study[J]. Office of Scientific & Technical Information Technical Reports, 2012, 6(37):76. 694

[5] Yang, J., Wang, H., Lv, Z., Wei, W., Song, H., Erol-Kantarci, M.,... & He, S. (2016). Multimedia recommendation and transmission system based on cloud platform. Future Generation Computer Systems. 695