Emission measurements according to, M1 (3 appendices)

Similar documents
Test Report. Glava AS. Emission test of Ecophon Venus according to M1 classification. October / November Smedeskovvej 38, DK-8464 Galten

M1 Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04

Test Report. Muovihaka Oy. Product Emissions in accordance with the Swedish Building Material Assessment Ultima graphite.

VOC TEST REPORT M1. 16 August Regulation or protocol Conclusion Version of regulation or protocol

VOC TEST REPORT M1. 23 October Regulation or protocol Conclusion Version of regulation or protocol

Test Report ROMA USA LLC. Product Emissions of Furniture in accordance with. Cradle to Cradle section 5.8 ECODOMUS SATIN BASE TR.

Test Report. Tremco-Illbruck GmbH & Co KG. Product Emissions Test (AgBB/DIBt Test Protocol) Butyl und Bitumenprimer. June 2011

VOC TEST REPORT M1. 6 April Regulation or protocol Conclusion Version of regulation or protocol

VOC TEST REPORT CDPH

VOC EMISSION TEST REPORT BREEAM NOR

Test Report in accordance CDPH-IAQ

VOC TEST REPORT CDPH

VOC TEST REPORT AgBB

Test Report in accordance CDPH-IAQ

VOC EMISSION TEST REPORT ISO 16000

ASTM D5116 Emissions Test Report with CDPH SM V Loading Scenarios per Cradle to Cradle Standard v3.0 Sect. 5.8

Test Report- VOC emission regulations in Europe

VOC TEST REPORT CDPH

EMICODE Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No. G12871B_02

Test Report- VOC emission regulations in Europe

Test Report- VOC emission regulations in Europe

EMICODE Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04

VOC TEST REPORT EMICODE

VOC TEST REPORT EMICODE

Test Report- VOC emission regulations in Europe

VOC TEST REPORT Indoor Air Comfort

VOC TEST REPORT Indoor Air Comfort GOLD

VOC TEST REPORT Indoor Air Comfort GOLD

Test Report- VOC emission regulations in Europe

VOC TEST REPORT Indoor Air Comfort GOLD

VOC EMISSION TEST REPORT Indoor Air Comfort GOLD

VOC TEST REPORT Indoor Air Comfort

VOC TEST REPORT Indoor Air Comfort GOLD

VOC TEST REPORT Tarkett Indoor Air Quality

VOC EMISSION TEST REPORT Indoor Air Comfort GOLD

VOC EMISSION TEST REPORT Indoor Air Comfort

Influence Of The Substrates On Water-based Paints Emissions Fabio Abbà,1*, Mikaela Decio 2, Tiziano Cerulli 2 and Roberto Leoni 2

VOC TEST REPORT Indoor Air Comfort GOLD

VOC EMISSION TEST REPORT Indoor Air Comfort GOLD

VOC TEST REPORT Indoor Air Comfort GOLD

VOC TEST REPORT Indoor Air Comfort GOLD

VOC EMISSION TEST REPORT Indoor Air Comfort GOLD

COMPLIANCE EMISSIONS TEST California Dept. of Public Health Standard Method Version 1.1 and FloorScore Flooring Evaluation

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

Test report No. MAIC Testing and evaluating of a digital printed paper material according to AgBB/DIBt-scheme.

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices)

TEST REPORT Formaldehyde Reduction

Intertek Environmental VOC Emissions

SURVEY OF CHEMICALS EMISSION FACTORS FROM BUILDING MATERIALS FOR INTERIORS

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

ISO INTERNATIONAL STANDARD. Indoor air Part 2: Sampling strategy for formaldehyde

This document is a preview generated by EVS

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

Test report No. MAIC Chamber emission test of a leather sample.

REPORT issued by an Accredited Testing Laboratory

MOLEKULE INC. TEST REPORT

AA-ANSIBIFMA-Jun2408, Page 1 of 16

Thermal Desorption Technical Support. Note 56: TD-GC/MS analysis of vapour-phase organic compounds for materials emissions testing.

REPORT. Client. Test object. Date of testt. Results. Rönnåsgatan 5B Ulricehamn. (7 appendices) content of the

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

ECMA Determination of Chemical Emission Rates from Electronic Equipment - Part 2 (not using-consumables) 8 th Edition / June 2017

ISO INTERNATIONAL STANDARD

PRO LIGNO Vol. 11 N pp

TÜV NORD Umweltschutz Sector: Hazardous substances

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

M+W Products. Controlled Environments Trace Analysis

Test Report No II

Method for the determination of 1,3-butadiene

THEORETICAL DETERMINATION OF THE SAMPLING RATES OF DIFFUSION SAMPLERS FOR VOCS AND ALDEHYDES

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

National Institute of Standards and Technology Gaithersburg, MD 20899

CHAPTER 6 GAS CHROMATOGRAPHY

Chromatography. Gas Chromatography

Information technology Office equipment Determination of chemical emission rates from electronic equipment

Paints and varnishes Determination of volatile organic compound (VOC) content. Part 2: Gas-chromatographic method

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD

This document is a preview generated by EVS

Magnitudes of Back Diffusion During Long-Term Diffusive Sampling of Volatile Organic Compounds Using Carbotrap and Chromosorb 106

Estimation Method of Emission Rate and Effective Diffusion Coefficient using Micro Cell

Open Column Chromatography, GC, TLC, and HPLC

AppNote 8/2000. Volatile Organic Compounds from Adhesives and their Contribution to Indoor Air Problems KEY WORDS ABSTRACT

HJ/T Translated English of Chinese Standard: HJ/T

Chapter 26. An Introduction to Chromatographic Separations. Chromatography

IMPROVEMENT OF IAQ BY COATING OF ADSORPTIVE POLYMER: THE DEVELOPMENT OF MATERIAL, EVALUATION AND ITS APPLICATION

Determination of Formaldehyde and VOCs in Wood-based Products using an Automated Micro-Scale Chamber

[ a ppl ic at ion no t e ]

REPORT issued by an Accredited Testing Laboratory

High Performance Liquid Chromatography

FORMALDEHYDE EMISSION A COMPARISON OF DIFFERENT STANDARD METHODS

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid

UV-PCO DEVICE FOR INDOOR VOCS REMOVAL: INVESTIGATION ON MULTIPLE COMPOUNDS EFFECT

Raw Material Finished product By product Exposure standards Length of shift Physical environment

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD IULTCS/IUC 19-3

ISO INTERNATIONAL STANDARD. Paints and varnishes Determination of volatile organic compound (VOC) content Part 1: Difference method

Tar & (SPA) tar analysis

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

Transcription:

issued by an Accredited Testing Laboratory Contact person Ulrika Johansson 2017-01-30 6F024225-1 1 (6) Chemistry, Materials and Surfaces +46 10 516 53 22 ulrika.johansson@sp.se Accred. No. 1002 Testing ISO/IEC 17025 Moelven Wood AB Tjalling Chaudron Box 8006 650 08 KARLSTAD Emission measurements according to, M1 (3 appendices) Assignment At the request of Moelven Wood AB an emission measurement according to M1 Emission Classification of Building Materials: Protocol for Chemical and Sensory Testing of Building Materials, ver 22.1.2015, has been carried out. The measurements are made after 28 days of conditioning regarding volatile organic compounds, carcinogenic compounds (EU Regulation No 1272/2008 Annex VI, cat 1A and 1B), formaldehyde, ammonia and sensory acceptability. For evaluation of test results the principle of shared risk is applied, i.e. for a max limit ( ) a result the limit complies and a result > the limit does not comply (ILAC G8 section 2.7). Product/test specimen Table 1. Product type: Construction plywood Product name: Vänerply K20/70 Ergo Manufacturing date: 2016-11-03 Packaging: 10 pieces of plywood 60 x 61 cm packed together in plastic foil. Arrived at SP: 2016-11-07 Test specimen preparation: Chemical testing: The boards were cut to size for wall scenario and placed back-to-back. The edges and part of the front sides were sealed with aluminium tape leaving an exposed surface area of 1.0 m 2. Deviation from protocol: No Test period started, date: 2016-11-11 Conditions during ageing: 23 ± 2 o C, 50 ± 5 % RH Emission samplings, date: 2016-12-08 Sensory testing: The boards were cut to size for wall scenario and placed back-to-back. The edges and part of the front sides were sealed with aluminium tape leaving an exposed surface area of 1.7 m 2. Postal address Office location Phone / Fax / E-mail Laboratories are accredited by the Swedish Board for Accreditation and SP Box 857 SE-501 15 BORÅS Sweden Brinellgatan 4 SE-504 62 BORÅS +46 10 516 50 00 +46 33 13 55 02 info@sp.se Conformity Assessment (SWEDAC) under the terms of Swedish legislation. This report may not be reproduced other than in full, except with the prior written approval of the issuing laboratory.

2017-01-30 6F024225-1 2 (6) Methods The specimens were conditioned outside the testing chambers in a controlled climate conditions of 23 ± 2 o C and 50 ± 5 % RH. The specimens were placed in the chambers three days before the measurement of chemical emission and two days before the sensory evaluation. Table 2. Chamber conditions of the test of chemical emissions Test chamber volume: 1.0 m 3, stainless steel Temperature: 23 ± 1 o C Relative Humidity: 50 ± 3 % RH Air exchange rate: 0.5 h -1 Air velocity at specimen surface: 0.1 0.3 m/s Area of sample: 1.0 m 2 Area specific air flow rate: 0.5 m 3 /m 2 h Table 3. Chamber conditions of the test of sensory acceptability Test chamber volume: 1.0 m 3, stainless steel Temperature: 23 ± 1 o C Relative Humidity: 50 ± 3 % RH Supply air flow rate: 0.9 l/s = 3.24 m 3 /h Area of sample: 1.7 m 2 Table 4. Emission sampling and analytical methods Test Sampling method Adsorbent Sampling volume (litre) Analysis method / Quantification Detection limit VOC ISO 16000-9:2006 1 Tenax TA 3.0 7.0 SP 0601 2 / FID quantification 1 µg/m 3 Formaldehyde ISO 16000-9:2006 1 DNPH 60 72 SP 2303 3 / HPLC-UV 0.03 µg/sampler Ammonia ISO 16000-9:2006 1 Treated silica gel Sensory evaluation 239 300 Liquid chromatograph with conductivity detector 4 ISO 16000-28:2012 5 -- -- Acceptability, Untrained panel of min 15 persons 1) Accredited method. 2) In accordance with ISO 16000-6:2011 and M1 protocol, accredited method. 3) In accordance with ISO 16000-3:2001, accredited method. 4) The determinations of the sampled silica gel tubes were done by Sahlgrenska Universitetssjukhuset, Miljökemiska laboratoriet, Göteborg, not accredited method. 5) In accordance with M1 protocol, not accredited method. 0.9 µg/sampler -- Tenax TA was used as adsorption medium for VOC The Tenax tubes were thermally desorbed and analysed in accordance to accredited SP method 0601, similar to ISO 16000-6:2011 (Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS/FID). This means an analysis in a gas chromatograph and detection with a flame ionisation detector

2017-01-30 6F024225-1 3 (6) (FID) and mass selective detector (MS). The FID signals are used for compound quantification. The TVOC is quantified as toluene equivalents. The mass selective detector is used for identification of compounds. The capillary column used is coated with 5% phenyl/ 95 % methylpolysiloxane. Tenax TA was also used as adsorption medium for testing of volatile carcinogenic compounds, according to EU Regulation No 1272/2008 Annex VI, cat 1A and 1B), (exclusive formaldehyde), 0.001 mg/m 3 and above. The compound specific response factors were calculated. The sampling of formaldehyde was carried out with DNPH samplers. The samplers were analysed according to accredited SP method 2302, similar to ISO 16000-3:2011(Indoor air-- Part 3:Determination of formaldehyde and other carbonyl compounds Active sampling method), which means analysis on a liquid chromatograph with absorbance detector. The sampling of ammonium was carried out with silicagel treated adsorbent tubes and analysis on a liquid chromatograph with conductivity detector. Minimum two subsequent samples were taken for the determination of VOC, formaldehyde and ammonia respectively. Results The results of the chemical testing are expressed as concentrations in the model room and as area specific emission rates: A model room has a volume of 30 m 3 and an air change rate of 0.5 changes per hour. The concentration of VOC in the model room can be calculated according to this equation: Conc = SERA A n V Conc = concentration of a VOC in the model room, in µg/m 3 SER a = area specific emission rate, in µg/m 2 h A = area of sample, in m 2 (31.4 m 2 for wall) n = air exchange rate, in changes per hour V = volume of the model room, in m 3 Table 5. Results of the chemical testing of the sample Vänerply K20/70 Ergo after 28 days Compound Concentration in model room mg/m 3 Emission rate mg/m 2 h Criteria M1 mg/m 2 h TVOC 6 0.108 0.052 < 0.2 Carcinogens < 0.001 < 0.001 < 0.005 Formaldehyde 0.015 0.007 < 0.05 Ammonia 7 < 0.004 < 0.002 < 0.03 6) The TVOC is calculated as the sum of the individual concentration > 5 µg/m 3 in model room concentration. 7) Not accredited method. Test report from Sahlgrenska Universitetssjukhuset: test report 2016:28 dated 2017-01-12.

2017-01-30 6F024225-1 4 (6) Table 6. Results of the sensory acceptability evaluation of the sample Vänerply K20/70 Ergo, after 28 days Evaluator Sensory evaluation Criteria M1 1 0.88 2 0.55 3 0.65 4 0.50 5 0.98 6 0.89 7 0.75 8-0.14 9 0.92 10 0.34 11 0.58 12-0.50 13 0.35 14 0.28 15 0.46 Arithmetic mean of acceptability 8 0.50 + 0.0 Standard deviation 0.41 90 % confidence interval of arithmetic mean 0.17 8) Not accredited method. The empty sensory test chamber acceptability was determined 2016-12-06. The mean acceptability vote of the empty chamber was > 0.8. Interpretation of the results The tested product Vänerply K20/70 Ergo complies with the requirements of M1 for the tested parameters.

2017-01-30 6F024225-1 5 (6) Detailed results Table 7. Detailed results (emission rates) of the chemical testing after 28 days Sample TVOC Formaldehyde Ammonia Carcinogens (mg/m 2 h ) as toluene equivalents between C 6 -C 16 (mg/m 2 h) (mg/m 2 h) (mg/m 2 h) between C 6 -C 16 1 0.052 0.007 0.002 < 0.001 2 0.051 0.007 0.002 < 0.001 Table 8. Single VOCs above 5 µg/m 3 in the model room (wall scenario), as toluene equivalents Single VOCs CAS Retention Concentration (µg/m 3 ) number time (min) Sample 1 Sample 2 Single VOCs C 6 -C 16 : 5.6 37.9 Acetic acid 64-19-7 5.6 6 6 Pentanal 110-62-3 8.5 12 12 Hexanal 66-25-1 11.7 43 44 α-pinene 80-56-8 17.2 30 31 β-pinene 127-91-3 9.2 12 12 Limonene 138-86-3 10.3 5 5 TVOC -- 5.6-37.9 108 108 Single VOC outside C 6 C 16 : VVOC ( < C 6 ) 9 4.8 5.6 Acetic acid, methyl ester 79-20-9 5.1 < 5 < 5 SVOC (C 16 C 22 ) 10 37.9-50.3 No single SVOC detected -- -- < 5 < 5 9) VVOC = very volatile organic compounds, as defined in ISO 16000-6 (not accredited) 10) SVOC = semi-volatile organic compounds, as defined in ISO 16000-6 (not accredited) Level of identification of compounds is 100 % for all compounds 5 µg/m 3. Measurements uncertainty The expanded measurement uncertainty of VOC result is 15 % (rel) and formaldehyde is 30 % (rel). The expanded measurement uncertainty for ammonia is 14 % (rel) according to the test report from Sahlgrenska Universitetssjukhuset.

2017-01-30 6F024225-1 6 (6) See appendix 1 for gas chromatogram from the VOC determination and appendix 2 for photo of a test specimen. Appendix 3 is the Sampling report received from the customer. Chemistry, Materials and Surfaces - Chemistry Performed by Examined by Signature_1 Ulrika Johansson Signature_2 Anders Lorén Appendices 1. Gas Chromatogram 2. Photo of test specimen 3. Sampling report

2017-01-30 6F024225-1 1 (1) Appendix 1 Gas chromatogram Sample: Vänerply K20/70 Ergo, after 28 days (sampled volume: 7.0 litres): Abundance Signal: 170109-24moelven1-2.D\FID1A.ch 1800000 1600000 1400000 1200000 1000000 800000 600000 400000 200000 Time--> 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.00

2017-01-30 6F024225-1 1 (1) Appendix 2 Photo of test specimen Vänerply K20/70 Ergo One of the test specimen for chemical emission

2017-01-30 6F024225-1 2 (1) Appendix 3