UNIVERSITY of CALIFORNIA SANTA CRUZ

Similar documents
Initial Studies in Proton Computed Tomography

Towards Proton Computed Tomography

Loma Linda University Medical Center, Loma Linda, CA 92354

Beam Test for Proton Computed Tomography PCT

Radiobiology at SCIPP

First Results and Realization Status of a Proton Computed Radiography Device

UNIVERSITY of CALIFORNIA SANTA CRUZ

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 54, NO. 1, FEBRUARY

Tracking Study of 200 MeV Protons within a PMMA. Phantom

III. Energy Deposition in the Detector and Spectrum Formation

PROTON radiation therapy is one of the most precise forms

2. Passage of Radiation Through Matter

The Hermes Recoil Silicon Detector

Particle Detectors. Summer Student Lectures 2010 Werner Riegler, CERN, History of Instrumentation History of Particle Physics

Emphasis on what happens to emitted particle (if no nuclear reaction and MEDIUM (i.e., atomic effects)

Particle Interactions in Detectors

Development of a Silicon PIN Diode X-Ray Detector

Passage of particles through matter

Proton stopping power and range calculation using effective atom number and effective electron density from dual energy CT

Heavy charged particle passage through matter

Experimental Particle Physics

Queen s University PHYS 352

Prototype Tracking Studies for Proton CT

The Most Likely Path of an Energetic Charged Particle Through a Uniform Medium

Today, I will present the first of two lectures on neutron interactions.

a) Dipartimento di Fisiopatologia Clinica, Università degli Studi di Firenze, v.le Morgagni 85, I-

Physics of Novel Radiation Modalities Particles and Isotopes. Todd Pawlicki, Ph.D. UC San Diego

The interaction of radiation with matter

Physics of particles. H. Paganetti PhD Massachusetts General Hospital & Harvard Medical School

Particle Energy Loss in Matter

Alpha-particle Stopping Powers in Air and Argon

Experimental Particle Physics

CHARGED PARTICLE INTERACTIONS

General Overview of Gas Filled Detectors

Physics of Radiotherapy. Lecture II: Interaction of Ionizing Radiation With Matter

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons

EEE4106Z Radiation Interactions & Detection

Experimental Particle Physics

Examples for experiments that can be done at the T9 beam line

EEE4101F / EEE4103F Radiation Interactions & Detection

Chapter 2 Radiation-Matter Interactions

Neutron Interactions Part I. Rebecca M. Howell, Ph.D. Radiation Physics Y2.5321

Particle Energy Loss in Matter

day1- determining particle properties Peter Wittich Cornell University

Beam Optics for a Scanned Proton Beam at Loma Linda University Medical Center

Modern Physics Laboratory (Physics 6180/7180)

Radioactivity and Ionizing Radiation

Outline. Chapter 6 The Basic Interactions between Photons and Charged Particles with Matter. Photon interactions. Photoelectric effect

Physics of Particle Beams. Hsiao-Ming Lu, Ph.D., Jay Flanz, Ph.D., Harald Paganetti, Ph.D. Massachusetts General Hospital Harvard Medical School

Interactions of particles and radiation with matter

Transverse momentum spectra using the Inner Tracking System of the ALICE experiment at LHC

Bhas Bapat MOL-PH Seminar October Ion Matter Interactions and Applications

Development of High-Z Semiconductor Detectors and Their Applications to X-ray/gamma-ray Astronomy

Dark Matter Particle Explorer: The First Chinese Cosmic Ray and Hard γ-ray Detector in Space

Interaction of Particles and Matter

Interaction of Particles with Matter

Neutron pulse height analysis (R405n)

Radiation (Particle) Detection and Measurement

GLAST Silicon Tracker Vertex 98, Santorini (Greece), Sep 29-Oct The Silicon Strip Tracker for the Gamma-ray Large Area Space Telescope

The next three lectures will address interactions of charged particles with matter. In today s lecture, we will talk about energy transfer through

PHY492: Nuclear & Particle Physics. Lecture 25. Particle Detectors

The LHC Experiments. TASI Lecture 2 John Conway

Interaction of Ionizing Radiation with Matter

THE mono-energetic hadron beam such as heavy-ions or

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Nuclear Physics and Astrophysics

The Silicon-Tungsten Tracker of the DAMPE Mission

Der Silizium Recoil Detektor für HERMES Ingrid-Maria Gregor

LET! (de / dx) 1 Gy= 1 J/kG 1Gy=100 rad. m(kg) dose rate

Interactions of Particulate Radiation with Matter. Purpose. Importance of particulate interactions

PHYS 352. Charged Particle Interactions with Matter. Intro: Cross Section. dn s. = F dω

The Large Area Telescope on-board of the Fermi Gamma-Ray Space Telescope Mission

GLAST Tracker. Hiroyasu Tajima On behalf of GLAST Tracker Team. Stanford Linear Accelerator Center, Stanford, CA , USA

Detectors in Nuclear Physics (48 hours)

Tracking detectors for the LHC. Peter Kluit (NIKHEF)

CHAPTER 12 TEST REVIEW

Reconstruction for Proton Computed Tomography: A Monte Carlo Study

Outline. Physics of Charge Particle Motion. Physics of Charge Particle Motion 7/31/2014. Proton Therapy I: Basic Proton Therapy

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Light ion recoil detector

DEVIL PHYSICS THE BADDEST CLASS ON CAMPUS IB PHYSICS

High energy gamma production: analysis of LAL 4-mirror cavity data

Detectors for High Energy Physics

Interaction of charged particles and photons with matter

Energy loss of alpha particles - Prelab questions

CRaTER Pre-Environmental Review (I-PER) Science Requirements Update

object objective lens eyepiece lens

Compton Camera. Compton Camera

PARTICLE ACCELERATORS

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Bethe-Block. Stopping power of positive muons in copper vs βγ = p/mc. The slight dependence on M at highest energies through T max

Interaction of Radiation with Matter

Validation of EM Part of Geant4

Search for supersymmetry with disappearing tracks and high energy loss at the CMS detector

PHY492: Nuclear & Particle Physics. Lecture 24. Exam 2 Particle Detectors

APPLIED RADIATION PHYSICS

Radiation Quantities and Units

Experimental Methods of Particle Physics

Monte Carlo Simulation concerning Particle Therapy

Transcription:

UNIVERSITY of CALIFORNIA SANTA CRUZ ENERGY LOSS OF PROTONS IN SILICON STRIP DETECTORS FOR COMPUTED TOMOGRAPHY A thesis submitted in partial satisfaction of the requirements for the degree of BACHELOR OF SCIENCE in PHYSICS by Carlin Fuerst June 21 The thesis of Carlin Fuerst is approved by: Professor Hartmut Sadrozinski Technical Advisor Professor David P. Belanger Thesis Advisor Professor David P. Belanger Chair, Department of Physics

Copyright c by Carlin Fuerst 21

Abstract Energy Loss of Protons in Silicon Strip Detectors for Computed Tomography by Carlin Fuerst The purpose of this paper is to analyze the effectiveness of a prototype instrument with applications in medical imaging. Radiobiologists at Loma Linda University Medical Center currently employ X-ray computed tomography as an imaging solution for their proton therapy patients. Researchers at the Santa Cruz Institute for Particle Physics have been commissioned to design and implement a prototype imaging solution that uses protons from the treatment beam instead of X-rays. This paper analyzes the energy loss of the particles as they pass through the tracking detectors before they reach the calorimeter which will aid engineers in creating a final product. Our preliminary results indicate that the GLAST 2 detectors and electronics show us higher than expected calculated energy absorption values, specifically differences of 121%, 129%, and 87% from the expected values for 35MeV, 1MeV, and 25MeV beam energies.

iv Contents List of Figures List of Tables Dedication Acknowledgements v vi vii viii 1 Introduction 1 1.1 Characteristics of Proton Therapy............................ 2 1.2 Description of pct..................................... 2 1.3 Proton Energy Loss.................................... 3 2 Analysis 6 2.1 TOT analysis........................................ 6 2.1.1 Figures....................................... 9 2.2 Energy loss of protons................................... 15 3 Conclusions 2 Bibliography 21

v List of Figures 1.1 A comparison of photon and proton energy absorption in tissue. [3].......... 3 1.2 PSTAR stopping power data for Silicon. [7]....................... 4 2.1 TOT histograms for all cluster sizes: 25MeV proton beam, 13.5mV threshold, all shaping resistors, internal triggering, ghosts removed.................. 9 2.2 TOT histograms for all cluster sizes: 1MeV proton beam, 13.5mV threshold, all shaping currents, internal triggering, ghosts removed.................. 1 2.3 TOT histograms for all cluster sizes: 35MeV beam energy, 13.5mV threshold, all shaping currents, internal triggering, ghosts removed.................. 11 2.4 TOT histograms for varying cluster sizes: 25MeV beam energy, 13.5mV threshold, 28kΩ shaping resistor, internal triggering, ghosts removed.............. 12 2.5 TOT histograms for varying cluster sizes: 1MeV beam energy, 13.5mV threshold, 28kΩ shaping resistor, internal triggering, ghosts removed.............. 13 2.6 TOT histograms for varying cluster sizes: 35MeV beam energy, 13.5mV threshold, 28kΩ shaping resistor, internal triggering, ghosts removed.............. 14 2.7 Layer, 28 kω calibration with second order approximation............. 15 2.8 Layer, 47kΩ calibration with second order approximation up to 25µs....... 17 2.9 Layer, 18kΩ calibration with second order approximation.............. 17 2.1 Layer 1, 28kΩ calibration with second order approximation.............. 18 2.11 A plot of expected energy loss and calculated energy loss for all beam energies and shaper resistors........................................ 19

vi List of Tables 1.1 Example data for relevant proton energies in Silicon................... 5 2.1 Calculations for Energy Loss in Silicon.......................... 18

vii To my loving parents, Peter and Lorrie Fuerst, who have always been there for me.

viii Acknowledgements I would like to thank my friend and colleague Brian Colby without whose patience and clarity the time until my graduation would extend asymptotically and Ford Hurley for allowing himself to be muddled by my cryptic coding skills. I would also like to thank my advisor Hartmut Sadrozinski for putting his trust in my abilities long enough for me to do something worthwhile.

1 1 Introduction Doctors at Loma Linda University Medical Center (LLUMC) currently employ a proton accelerator to generate a beam of high-energy protons for the purpose of treating cancerous tumors. The benefit of this form of radiation therapy is the ability to treat localized, isolated, solid tumors before they spread to other tissues and to the rest of the body[1]. While the treatment uses protons, X-ray Computed Axial Tomography (CAT) is currently used to generate three dimensional images of the patients tumors. The drawbacks of this combination of proton treatment and X-ray imaging are that the instrumentation for both exist in separate rooms due to the size of the apparatus which requires the patient to be moved around and that the fundamental differences between the ways in which protons and photons interact with matter may limit the physical insight that we glean from the images. As a solution, engineers at the Santa Cruz Institute for Particle Physics (SCIPP) have been commissioned by LLUMC to develop the hardware for a Proton Computed Tomography (pct) system that uses protons from the accelerator to image cancer patients. This is currently being done with Silicon Strip Detectors (SSDs) and custom readout electronics that were originally designed for the Gamma-ray Large Area Space Telescope (GLAST) aka Fermi for which SCIPP was a contributing research group. This paper will describe the progress of hardware development and analysis of the energy loss of protons through the tracking SSDs before they are inevitably measured by the calorimeter and the implications of this on the eventual imaging solution[2].

2 1.1 Characteristics of Proton Therapy Using high-energy protons for radiation oncology was first proposed in 1946 and since then, several hospitals around the world have built proton accelerators for this purpose[1]. In the accelerator, hydrogen atoms are stripped of their electrons and sent through a vacuum tube within a pre-accelerator. At this point, the protons have each gained 2MeV in kinetic energy before entering the synchrotron where they travel around the loop 1 million times per second, gaining energy every trip from a radio frequency cavity in the loop. By the time the protons leave the accelerator, they have an energy between 7 and 25MeV. It is the nature of charged particles at these energies to penetrate matter while depositing a fraction of their energy via the excitation of electrons in the material. This interaction is described by the Bethe-Bloch formula which gives the mean stopping power of a material as a function of particle energy. In this model and range of energies, higher energy particles deposit less energy-per-distance penetrated than lower energy particles. This results in the particles depositing most of their energy deep inside a material, as opposed to near the surface as with X-rays, and this energy loss is characterized by what is called a Bragg peak. With a range of proton energies and a rotating beam aperture, the dose can be localized in a discrete volume within the patient resulting in a lower amount of collateral healthy tissue damage than X-ray therapy. 1.2 Description of pct The system currently in development at SCIPP through collaboration with LLUMC called pct will provide doctors with an imaging solution that utilizes protons originally intended for radiation therapy which would simplify and potentially improve the process of treatment. The pct system would contain as few as three main detectors for the purpose of particle tracking: Two tracking SSDs to record the X and Y positions of incident particles and a CsI calorimeter to measure the energy of said particles. The position trackers also have the ability to measure charge deposited in the detector in the form of TOT, or time over threshold, by converting the signal of the charge in

3 Figure 1.1: A comparison of photon and proton energy absorption in tissue. [3] a strip entering the GTFE (GLAST Tracker Front End chip) into a pseudo-gaussian via the shaper. The voltage in the shaper is compared to a threshold voltage via a discriminator and the amount of time that this voltage is larger than the threshold voltage is the TOT reading[4]. A modified version of the GLAST readout electronics has been developed at SCIPP to take data with the SSDs on a scale useful to the project and a Data Acquisition (DAQ) system based on the one developed for the Particle Tracking Silicon Microscope (PTSM)[5] at SCIPP is being employed to record the data. These images will be used by doctors to locate and measure tumors for accurate targeting during treatment. 1.3 Proton Energy Loss The intent of these analyses is to measure the energy loss of protons as they pass through the SSDs and compare this measurement to theory. The theoretical model which applies in this case is the Bethe-Bloch equation, Eq. 1.1, which describes the energy loss per unit thickness de/dx per

4 1 Mean Stopping Power of Protons in Silicon Stopping Power (MeV cm 2 /g) 1 1.1 1 1 1 1 Energy (MeV) Figure 1.2: PSTAR stopping power data for Silicon. [7] unit via the ionization of the atoms in a material[6]: de dx = Z 1 Kz2 A β 2 [ 1 2 ln 2m ec 2 β 2 γ 2 T max I 2 β 2 δ ] 2 (1.1) In this case, K/A.37MeVg 1 cm 2, Z is the atomic number of the absorber, z is the charge of the incident particle in units of fundamental charge, β is the special relativistic v c, m ec 2 is.51mev, γ is the Lorentz factor, T max is the maximum kinetic energy which can be imparted to a free electron in a single collision (see below), and I is the mean excitation energy (1eV). T max is described as the following: T max = 2m e c 2 β 2 γ 2 1 + 2γm e /M + (m e /M) 2 (1.2) where M is the incident particle mass (MeV/c 2 ). The National Institute of Standards and Technology (NIST) provides tables for the stopping powers, within 1 percent, of protons in different materials which include minor corrections to the Bethe-Bloch equation shown above. With these data one can determine the total energy deposited within a material using the

5 integral E = de dx dx or an equivalent small thickness approximation. Table 1.1: Example data for relevant proton energies in Silicon. Beam Energy Total Stopping Expected Energy Loss (MeV) Power (MeVcm 2 /g) in 4µm Si (MeV) 3.5 1 1 1.32 1 1 1.21 1 1. 1 2 5.838 1 5.44 1 1 2.5 1 2 3.165 1 2.95 1 1

6 2 Analysis 2.1 TOT analysis At LLUMC The detector board was placed such that the tracking detectors were in the path of the proton beam. Tests were performed at various energies and readout configurations and data were collected. First, we see histograms of the TOT measurements from the SSDs for a beam energy of 25MeV (Fig. 2.1) at a threshold voltage of 13.5mV, internal triggering, and ghosting events (events for which multiple strips went over threshold that were not adjacent) removed for four different chip regions: The X plane (Layer 1) region and three regions on the Y plane (Layer ); each corresponding to a pair of GTFEs that share a distinct shaping current. Increasing the current feeding the shaper by reducing the resistance in the circuit reduces the shaping time, the time it takes the shaper to reach a maximum voltage. Increasing the resistance, however, may cause the shaped pulse to be longer which may cause overflow in the TOT data. As we can see from Fig. 2.1 the MPV TOT increases inversely with shaper current (i.e. increases directly with shaper resistance) which is what we expect. Next we see histograms of the TOT (Fig. 2.2 and 2.3) for energies 1MeV and 35MeV with similar results. An interesting thing to note is that as the incident particle energy decreases for a given region we see the MPV TOT increases which means that the amount of energy deposited increases which we know from Fig. (1.2). Also as particle energy decreases the amount of overflow, events for which measurement was higher than the maximum value, in the layer 1 increases from

7 5% of total events to 9% and 2% for 25, 1, and 35MeV, respectively. At 35MeV in layer region 1 (Fig. 2.3(b)) we can see that a large number of events are overflow. Also at 35MeV the histograms are considerably less smooth than their 1 and 25MeV counterparts. This may be explained by the Bethe-Bloch equation which shows that energy deposited by particles increases as their total energy decreases which means that the energies of particles passing through the detectors may become more varied as the initial beam energy decreases. Because of the way the GTFEs work it is possible for more than one strip on the SSD to gain enough charge to go above threshold which we call a cluster. When this happens, a single TOT is recorded: the largest value of TOT of all strips hit in an event. Because of this wider distribution of charge, we might expect to see a lower MPV TOT for a given beam energy as the number of strips in a cluster increases. What we do see, rather, is little or no difference in the mean TOT for varying cluster sizes. In fact, in some cases i.e. 25MeV beam energy (Fig. 2.4), we see the MPV TOT slightly increase suggesting more charge was deposited in the SSD. For 1MeV (Fig. 2.5) we do see a slight decrease in the MPV TOT as cluster size increases but the decrease is not significant. For 35MeV (Fig. 2.6) we do see a marked difference in MPV TOT for events with three strips over threshold but as the distribution bleeds into overflow, it is difficult to make a judgment on the significance of the increase. If we look at the proportions of cluster sizes in Fig. 2.4(d), 2.6(d), and 2.5(d) we see a clear difference for 35MeV from 1 or 25MeV. The proportion of two and three strip events to single strip events increases noticeably. One possible explanation for this could be multiple Coulomb scattering which describes the scattering of nuclei as they pass close to other nuclei. The equation for the angle which encompasses 98% of the projected distribution is as follows[6]: θ = 13.6MeV βcp z x/x [1 +.38ln(x/X )] (2.1) According to Physics Letters B, here, p, βc, and z are the momentum, velocity, and charge number of the incident particle, and x/x is the thickness of the scattering medium in radiation lengths. In this case, z=1 for a proton, βc is 7.974 1 7 m/s for a 35MeV proton, p is 8.621 1 7 MeV s m, and

8 x is the detector thickness of 4µm. X is defined by the following equation: 716.4ρA X = Z(Z + 1)ln(287/ Z) (2.2) which, since ρ=2.33g/cm 2, A=28 and Z=14 for silicon, gives us a value of 9.45cm. This means that θ is.12 radians. With a thickness of 4µm, θ times the thickness will give us the approximate scattering length of 2.33µm. With a detector strip pitch, or distance between strips, of 228µm this means that multiple Coulomb scattering does not account for the increase of larger cluster sizes. An alternate explanation is that the increased energy deposition from lower energy particles is just enough to set strips that were otherwise charged for 1 and 25MeV beams over the threshold.

9 2.1.1 Figures Entries 41489 Mean 12.46 Overflow 4756 1 Constant 5.725e+4 MPV 9.341 Sigma 1.392 8 6 4 2 Region 1 Y Entries 4278 Mean 24.8 Overflow 159 6 Constant 275.1 MPV 19.64 Sigma 3.44 5 4 3 2 1 5 1 15 2 25 3 35 4 45 5 5 1 15 2 25 3 35 4 45 5 12 1 8 6 4 2 (a) Layer 1; 28kΩ resistor; Median: 11.3 Region 2 Y Entries 397755 Mean 1.61 Overflow 5431 Constant 6.677e+4 MPV 7.365 Sigma 1.192 5 1 15 2 25 3 35 4 45 5 (b) Layer region 1; 47kΩ resistor; Median: 23.3 Region 3 Y Entries 1215 Mean 9.54 4 Overflow 131 Constant 1848 35 MPV 6.239 Sigma 1.7 3 25 2 15 1 5 5 1 15 2 25 3 35 4 45 5 (c) Layer region 2; 28kΩ resistor; Median: 8.9 (d) Layer region 3; 18kΩ resistor: Median: 7.7 Figure 2.1: TOT histograms for all cluster sizes: 25MeV proton beam, 13.5mV threshold, all shaping resistors, internal triggering, ghosts removed

1 Entries 41523 Mean 21.66 Overflow 3.59e+4 Constant 2.762e+4 5 MPV 16.97 Sigma 2.978 4 Region 1 Y Entries 3435 3 Mean 35.85 Overflow 113 Constant 15 25 MPV 4.52 Sigma 8.43 2 3 15 2 1 1 5 5 1 15 2 25 3 35 4 45 5 5 1 15 2 25 3 35 4 45 5 (a) Layer 1; 28kΩ resistor; Median: 2.5 Region 2 Y Entries 39572 Mean 2 6 Overflow 2.989e+4 Constant 2.84e+4 MPV 14.49 5 Sigma 2.78 4 (b) Layer region 1; 47kΩ resistor; Median: 42.5 Region 3 Y Entries 7185 Mean 17.12 12 Overflow 465 Constant 541.6 MPV 11.29 1 Sigma 2.473 8 3 6 2 4 1 2 5 1 15 2 25 3 35 4 45 5 5 1 15 2 25 3 35 4 45 5 (c) Layer region 2; 28kΩ resistor; Median: 17.9 (d) Layer region 3; 18kΩ resistor; Median: 14.5 Figure 2.2: TOT histograms for all cluster sizes: 1MeV proton beam, 13.5mV threshold, all shaping currents, internal triggering, ghosts removed

11 Entries 13729 Mean 34.7 16 Overflow 2.955e+4 14 12 1 8 6 4 2 Constant 6918 MPV 32.12 Sigma 3.85 5 1 15 2 25 3 35 4 45 5 Region 1 Y Entries 5779 5 4 3 2 1 Mean 37.17 Overflow 5.584e+4 Constant 1.57e+4 MPV 437.4 Sigma 131 5 1 15 2 25 3 35 4 45 5 5 4 3 2 1 (a) Layer 1; 28kΩ resistor; Median: 36.5 Region 2 Y Entries 51731 Mean 31.75 7 Overflow 9721 Constant 314 6 MPV 28.64 Sigma 3.74 5 1 15 2 25 3 35 4 45 5 (b) Layer region 1; 47kΩ resistor; Median: N/A Region 3 Y Entries 26974 4 35 Mean Constant 26.19 1419 Overflow MPV 5732 21.52 3 Sigma 3.31 25 2 15 1 5 5 1 15 2 25 3 35 4 45 5 (c) Layer region 2; 28kΩ resistor; Median: 33.1 (d) Layer region 3; 18kΩ resistor: Median: 27.1 Figure 2.3: TOT histograms for all cluster sizes: 35MeV beam energy, 13.5mV threshold, all shaping currents, internal triggering, ghosts removed

12 Entries 356346 Mean 12.45 9 8 7 6 5 4 3 2 1 Overflow 3977 Constant 4.956e+4 MPV 9.335 Sigma 1.383 5 1 15 2 25 3 35 4 45 5 Entries 5216 Mean 12.54 Overflow 597 12 Constant 7131 MPV 9.379 Sigma 1.384 1 8 6 4 2 5 1 15 2 25 3 35 4 45 5 (a) 1 strip over threshold Entries 45 Mean 13.19 1 Overflow 78 Constant 47.9 MPV 9.51 8 Sigma 1.619 (b) 2 strips over threshold Entries 41489 3 1 35 3 Mean 1.142 Overflow 4 25 6 4 2 5 1 15 2 25 3 35 4 45 5 2 15 1 5 2 4 6 8 1 12 Num strips X (c) 3 strips over threshold (d) Cluster size Figure 2.4: TOT histograms for varying cluster sizes: 25MeV beam energy, 13.5mV threshold, 28kΩ shaping resistor, internal triggering, ghosts removed

13 Entries 339185 Mean 21.72 45 4 35 3 25 2 15 1 5 Overflow 2.96e+4 Constant 2.273e+4 MPV 16.99 Sigma 2.997 5 1 15 2 25 3 35 4 45 5 Entries 67438 Mean 21.39 1 Overflow 557 Constant 4695 MPV 16.82 8 Sigma 2.841 6 4 2 5 1 15 2 25 3 35 4 45 5 3 2 1 (a) 1 strip over threshold Entries 3137 Mean 21.15 5 Overflow 273 Constant 197 MPV 16.86 4 Sigma 2.826 5 1 15 2 25 3 35 4 45 5 3 25 2 15 1 5 (b) 2 strips over threshold Entries 41523 3 1 35 Mean 1.173 Overflow 1 2 4 6 8 1 12 Num strips X (c) 3 strips over threshold (d) Cluster size Figure 2.5: TOT histograms for varying cluster sizes: 1MeV beam energy, 13.5mV threshold, 28kΩ shaping resistor, internal triggering, ghosts removed

14 Entries 8444 Mean 33.73 1 8 6 4 2 Overflow 1.629e+4 Constant 458 MPV 31.56 Sigma 3.52 5 1 15 2 25 3 35 4 45 5 Entries 38562 45 Mean 34.6 Overflow 824 4 Constant 1942 MPV 32.14 35 Sigma 3.895 3 25 2 15 1 5 5 1 15 2 25 3 35 4 45 5 8 6 4 2 (a) 1 strip over threshold Entries 13568 Mean 37.9 Overflow 544 Constant 445.3 1 MPV 38.55 Sigma 6.666 5 1 15 2 25 3 35 4 45 5 (b) 2 strips over threshold Entries 13729 8 7 6 5 4 3 2 1 Mean 1.555 Overflow 2 4 6 8 1 12 Num strips X (c) 3 strips over threshold (d) Cluster size Figure 2.6: TOT histograms for varying cluster sizes: 35MeV beam energy, 13.5mV threshold, 28kΩ shaping resistor, internal triggering, ghosts removed

15 2.2 Energy loss of protons To convert our TOT measurements into energy deposited we need to look at our TOT/Charge calibration data. Calibration takes place when a 46pF capacitor is charged with a known calibration voltage and the resulting charge is injected into a strip on the SSD. This creates a pulse within the GTFE s shaper which then gives us a TOT reading. With these data, we can create fits to correlate input charge with TOT, for a given threshold voltage, 13.5mV in this case. Calibration ToT (us) 5 4 3 gtfe3 Entries 3582 Mean x 24.21 Mean y 8.556 RMS x 11.47 RMS y 3.678 2 c / ndf.8252 / 6 p.58 ± 19.24 p1.354 ± 1.372 p2 -.6945 ±.226 2 1 5 1 15 2 25 3 35 4 45 5 Charge (fc) Figure 2.7: Layer, 28 kω calibration with second order approximation As 2.7 shows, for example, we get a relationship for GTFE 3, Layer that TOT =.58+.354Q 6.95 1 4 Q 2. If we apply the mean TOT for a given beam energy to this formula, we can solve for Q and the lower root, on the ascending side of the quadratic, should be the value for the mean of the charge deposited in the detector. Because of the limitations of the calibration routine, calibration data plateaus at 25µs which is half of the maximum TOT the prototype can record. For beam test TOT data larger than 25µs the fits were extrapolated using the equations acquired from the calibration graphs which introduces a large amount of error for large TOTs. Since using the mean, according to the histograms, isn t precise as there will always be

16 some overflow, we use the median, which is close to the mean (about 1% less than the mean in the case of Fig. 2.1(a)) and isn t affected by overflow, to estimate the real mean which will become more important for the cases with high overflow. This means that the calculations of the energy using the median will be an underestimate of the energy that could be calculated with the true mean. When the charge is found, we can then convert it to energy using the following relationship: E Q = E i e.2247mev fc (2.3) where E is the energy deposited in MeV, Q is the charge deposited in fc, e is the elementary charge of an electron ( 1.62 1 4 fc), and E i is the energy required to create an electron-hole pair ( 3.6 1 6 MeV). We can then compare this to the mean energy loss as outlined by NIST (Fig. 1.2) with the following equation: E de dx (MeV cm2 /g)ρ Si x (2.4) where ρ Si is the density of Silicon ( 2.33 g cm 3 ) and x is the detector thickness (.4cm). Since the mean energy deposited according to Eq. 2.4 at 1MeV is approximately.54mev and the change in stopping power is less than 1% for this change in energy this is a good approximation for the energy deposited within.5mev. Comparing this to the value of 1.24MeV we get from applying the median TOT of 17.9µs from table 2.1 to the calibration fit and Eq. 2.3 we see a difference experimental of 129% from the predicted value. Similarly the results of.56mev and 2.71MeV we get for 25MeV and 35MeV beams differ from the expected values of.3mev and 1.21MeV by 87% and 124% respectively. Table 2.1 and Fig. 2.11 show the results for the calculated mean energy loss along with the expected energy loss for various energies and shaping resistors. If we compare the energies calculated between layer 1 and layer region 2, we would expect to see very similar results as the energy lost when the beam passed through layer would barely affect the energy loss in layer 1. Expected Energy Loss column of table 2.1 show, for example,.544mev vs..546mev for a 1MeV beam for layers and 1 respectively. What we see in fact is a substantial difference between the two results of 1.24MeV and.81mev.

17 Calibration ToT (us) 5 4 3 gtfe1 Entries 3584 Mean x 24.19 Mean y 2.9 RMS x 11.47 RMS y 5.74 2 c / ndf 1.363e-25 / p.9729 ± 59.78 p1 1.233 ± 9.648 p2 -.553 ±.3423 2 1 5 1 15 2 25 3 35 4 45 5 Charge (fc) Figure 2.8: Layer, 47kΩ calibration with second order approximation up to 25µs Calibration ToT (us) 5 4 3 gtfe4 Entries 3584 Mean x 24.2 Mean y 1.85 RMS x 11.46 RMS y 4.543 2 c / ndf.295 / 7 p -.141 ± 8.949 p1.5233 ±.6382 p2 -.2953 ±.1237 2 1 5 1 15 2 25 3 35 4 45 5 Charge (fc) Figure 2.9: Layer, 18kΩ calibration with second order approximation

18 Calibration ToT (us) 5 4 3 1gtfe3 Entries 3586 Mean x 24.19 Mean y 14.35 RMS x 11.46 RMS y 6.11 2 c / ndf.2381 / 4 p.2871 ± 22.53 p1.6558 ± 1.825 p2 -.2567 ±.354 2 1 5 1 15 2 25 3 35 4 45 5 Charge (fc) Figure 2.1: Layer 1, 28kΩ calibration with second order approximation Table 2.1: Calculations for Energy Loss in Silicon Beam Shaping Median Mean Mean Expected Energy Layer Resistor TOT Charge Energy Energy Loss (MeV) (kω) (µs) Deposited Loss in 4µm (fc) (MeV) Si (MeV) 47 1.21 35 28 33.1 12.6 2.71 1.21 1 28 36.5 8.7 1.81 1.25 18 27.1 1.21 47 42.5 41.3.93.54 1 28 17.9 55.1 1.24.54 1 28 2.5 35.9.81.55 18 14.5 34.4.77.54 47 23.3 19.9.45.3 25 28 8.9 24.9.56.3 1 28 11.3 18.1.41.3 18 7.7 16.2.36.3 TOT did not correspond to a charge according to calibration data fits.

19 3 2.5 Mean Stopping Power of Protons in Silicon Expected Energy Loss Layer Energy Loss for 47kΩ Layer Energy Loss for 28kΩ Layer Energy Loss for 18kΩ Layer 1 Energy Loss for 28kΩ 2 Energy Loss (MeV) 1.5 1.5 5 1 15 2 25 3 Energy (MeV) Figure 2.11: A plot of expected energy loss and calculated energy loss for all beam energies and shaper resistors.

2 3 Conclusions Our findings show a 121%, 129%, and 87% discrepancy between the predicted and experimentally measured values of the energy deposited in the GLAST 2 SSDs for proton beam energies of 35MeV, 1MeV, and 25MeV, respectively. This means that measuring the energy of the particle that was lost directly via the SSDs may not be an accurate method. An analysis of the energy detected by the calorimeter with and without the SSDs would show greater insight into the effects of the SSDs on the particles and thus the effectiveness of the SSDs in measuring energy. Sources of error may include charge sharing between several strips or a different thickness of detector than assumed but as charge sharing would result in a lower TOT and therefore lower energy measured and the detectors should be close to the referenced thickness within less than 1µm these sources are unlikely and would have little effect anyway.

21 Bibliography [1] Loma Linda University Medical Center. Proton Technology. 17 Jun 29 <http://www. protons.com/proton-therapy/proton-technology.html>. [2] W. P. Levin, Proton beam therapy. British Journal of Cancer, 93.849854, 27 Sep 25. [3] Wikipedia. Bragg Peak. 17 Jun 29 <http://en.wikipedia.org/wiki/file:braggpeak. png>. [4] R. Johnson, Tracker Front End Readout ASIC Specification. LAT-SS-169-4, 3 Mar 23, pp. 9, 1. [5] B. Keeney, The Design, Implementation, And Characterization Of A Prototype Readout System For The Particle Tracking Silicon Microscope. (M.S. Thesis) University of California Santa Cruz, Sep 24. [6] L. Alvarez-Gaumé, Review of Particle Physics. Physics Letters B. Elsevier, 592.1-4, 15 Jul 24, pp. 242-245. [7] National Institute of Standards and Technology. PSTAR. 17 Jun 29 <http://physics. nist.gov/physrefdata/star/text/pstar.html>.