OPTIMIZING METALS SAMPLE PREP

Similar documents
Test Method: CPSC-CH-E

Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

ICP-OES Application Note Number 35

Testing and Calculating. Cannabis. Uncertainty. Analytical Chemistry and Cannabis

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

Analysis of domestic sludge using the Agilent 4200 MP-AES

H E L P I N G C H E M I S T S. UltraCLAVE. The Next Generation Microwave Digestion System

Analysis of trace elements in polymer samples to ensure compliance with WEEE-RoHS standards using the Thermo Scientific icap 7200 ICP-OES

Basic Digestion Principles

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Today s Agilent Solutions for Determining Heavy Metals in Food using Atomic Spectroscopy

The Investigation of Fertilizer Analyses Using Microwave Digestion and the Agilent 720-ES

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Product Descriptions and Offerings

Laboratory 101: A Guide to Understanding your Testing Laboratory

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

110 Lowell Rd Hudson, NH USA Tel:

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

INVESTIGATION OF ICP-OES ANALYSIS FOR DETERMINATION OF TRACE LEAD IN LEAD-FREE ALLOY

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Preparation of Food and Feed Samples for Metals Analysis

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

USGS Troy WSC Laboratory Inductively Coupled Plasma- NH4Cl Soil Extracts SOP 425 Jordan Road Rev. No. 2.0 Troy, NY Date: 03/16/2012 Page 1 of 7

TECHNETIUM-99 IN WATER

U.S. EPA SW-846 Method 6010C Using the Prodigy7 High- Dispersion ICP Introduction. Application Note - AN1305. Experimental

á233ñ ELEMENTAL IMPURITIES PROCEDURES

Concept of Elemental Impurities (EI) assessment in finished dosage forms by total extraction testing

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

DISCLAIMER: This method:

(CATION EXCHANGE AND LN RESIN, WITH VACUUM BOX SYSTEM)

Determination the elemental composition of soil samples

Automated Determination of PPQ Levels of Thorium in High Purity Copper

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Product Information. Silicon Carbide Well Plates

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

The Determination of Toxic, Trace, and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

OES - Optical Emission Spectrometer 2000

1.1. This is a method for the separation and measurement of 228 Ra in water via its beta emitting 228 Ac daughter.

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Determination of Nutrients. Determination of total phosphorus. Extraktion with aqua regia, reflux method. Introduction

NICKEL-63/59 IN WATER

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

TECHNETIUM-99 IN SOIL

Not Just for Paint Chips Anymore. High Throughput, Open Vessel Microwave Digestion of Matrices Requiring Moderate Conditions

BRIEFING 1730 THEORY AND PRACTICE OUTLINE

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Atomic Spectroscopy AA/ICP/ICPMS:

High purity acids and bases

Leaching of Heavy Metals Contaminants in Recycled Polyethylene Terephthalate Used for Food Packaging

Application note. Determination of exchangeable cations in soil extracts using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer

Graphite Block Acid Digestion System ODLAB

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

Cadion Method Method to 0.30 mg/l Cd TNTplus 852

Oxygen Demand, Chemical

Trace elemental analysis solutions for your application. June 6, 2018

Application of the Agilent 7900 ICP-MS with Method Automation function for the routine determination of trace metallic components in food CRMs

Elemental Scientific. Spike Recovery. Elemental Scientific

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

TECHNETIUM-99 IN WATER

Sample Preparation of Electronic Device Components for Hexavalent Chromium Analysis by IEC Method :2017

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Agenda. Recent Advances in Detection of Heavy Metals in Foods. NQAC Organization

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Even wall thickness to with stand maximum G force.

PAR Method Method to 2.0 mg/l Pb TNTplus 850

The Evolution of Inductively Coupled Plasma - Optical Emission Spectroscopy (ICP-OES)

Environmental Series - Trace contaminant analysis in brine using a Thermo Scientific icap 6000 Series Duo ICP

Mercury Determination in Lichen, BCR-482, Using the QuickTrace M-7600 CVAAS Mercury Analyzer

TITLE: Surface Decontamination of Iodine Compounds (Potassium Iodide (KI)) by DeconGel TM

Following documents shall be used for reference on quantities, units, prefixes and other technical vocabulary in this document:

Determination of Phosphorus and Sulfur with Dynamic Reaction Cell ICP-MS

High-Throughput Semiquantitative Screening of Ambient Air Samples by ORS-ICP-MS and Integrated Sample Introduction System (ISIS) Application

Transcription:

APPLICATION NOTE OPTIMIZING METALS SAMPLE PREP Utlilizing Single Reaction Chamber (SRC)Technology for Trace Metals Analysis for contract laboratories. Contract analytical laboratories use a variety of instrumentation for trace metals analysis and must take advantage of method standardization whenever there is an opportunity. To ensure high quality data and a standard operation for a variety of industrial samples, these laboratories use microwave digestion for sample preparation before inductively coupled plasma-optical emission spectrometry (ICPOES) or ICP-mass spectrometry analysis. This tech note describes optimized single-reaction-chamber microwave digestion methods, including vessel selection, sample size, and temperature pro les, along with ICP-OES data. The on-demand priorities and round-the-clock nature of commercial testing laboratories often requires innovative solutions to meet client demand while maintaining high data quality. Laboratory capability has become even more critical with the increased complexity of sample ranges from multiple industries, including consumer products, clinical samples, pharmaceuticals and ne chemicals. A combination of capabilities and diverse instrumentation will allow a contract laboratory to include development and validation of methods for material components such as polymers, metals, foils, inks, adhesives, labels, liners, seals, coatings, toys, food, and active pharmaceutical ingredients. Without question, the goal is to nd a exible, easy-to-use sample preparation approach that is coupled with the capability of determining any element over wide concentration ranges. Standardizing multi-element sample preparation to include little or no method development, higher temperature and pressure exibility, the capability of processing mixed sample batches and a variety of acid combinations simultaneously, and the option of disposable vials offers increases in laboratory productivity to match fast analysis turnaround times. Conventional closed-vessel microwave digestion has been recognized for the last two decades as the most effective technique for the digestion of the widest range of sample types in metals analysis, largely because of its ability to operate at high temperatures and pressures. Because the Page 1

an intense amount of labor dedicated to vessel cleaning and vessel assembly and disassembly (1). The most signi cant limitation comes from the conventional closed-vessel approach s inability to process incoming samples simultaneously; samples must be batched by sample type and acid combination. Given the high demand of contract laboratory environments, there has been a heavy emphasis on improving the technology for sample preparation. Figure 1. SRC Microwave Digestion digestions are in a closed vessel, cross-contamination and the loss of volatile elements are eliminated (1). Additionally, microwave sample preparation techniques have overcome challenges of poor digestion quality by providing better digests with low residual acidity, lower carbon content and lower concentrations of dissolved solids, a critical feature necessary for back-end inductively coupled plasma-mass spectrometry (ICP-MS) and optical emission spectrometry (ICP-OES) analysis (2). It has been recently suggested that an ideal sample preparation procedure would be capable of digesting large sample amounts, provide high throughput, be compatible with multi-element analysis, and be safe, green and easy to use (3). Unfortunately, in the context of commercial high-throughput laboratories, conventional closed-vessel microwave digestion has limitations, such as METHODS AND MATERIALS SRC microwave digestion is a relatively new closed-vessel technology that is different from traditional designs that include multiple closed-vessels inside a cavity (4). The single reaction chamber uses a large, pressurized reaction chamber where all samples are digested simultaneously. Through this approach the chamber itself is the microwave cavity, enabling high microwave energy and distribution. It also provides an opportunity to place multiple vials in the closed system and eliminates the need to rotate samples during a digestion program. The chamber is pre-pressured with inert gas, providing a virtual cap and raising the boiling point of any acids used during a digestion run. The most critical result of pre-pressurization is that it enables different sample types and different acid combinations to be processed in a single operation by placing samples in PTFE, quartz, or disposable glass vials and loading them into an autosample rack set to t the chamber. In addition to the bene ts of mixed-sample batches, no loss of volatile elements, the elimination of vessel assembly and an option of using disposable glass vials, this SRC design can operate at very high temperature and pressure up to 300 o C and 199 bar, respectively. Labs can now digest more dif cult samples with a standardized approach consisting of Figure 2. Schematic ow diagram of SRC microwave operation. Page 2

digestion of the full range of incoming sample types, with adjustments to the acid combination to account for jewelry or samples of a siliceous nature. Figure 3. Mixed batch SRC microwave diigestion run. the following steps: with any incoming sample (mix of easy and dif cult), determine sample weight; choose the type of vial, acid combination, temperature, and time of digestion; and analyze. This tech note details these key criteria for routine use of SRC microwave digestion in a commercial contract laboratory. Detailed review of the capabilities and use can be found in a number of recent accounts (1,2,4). All digestions were developed using an UltraWAVE microwave oven based on SRC design (Figure 1). The UltraWAVE delivers 1500 W of microwave power to a 1L chamber that can hold sample racks with 5, 15 or 22 vessels depending on the sample and volume. Direct temperature and pressure control of the chamber provides direct control of each sample (all samples reach the same temperature and pressure). A schematic ow diagram of the system s operation is shown in Figure 2. The experiments were performed with a 15-position rack and 15 (15 ml volume) disposable glass vials. An icap 6300 duo ICP-OES system composed of an EMT duo quartz torch, cyclonic glass spray chamber, and Burgener nebulizer was used for the analysis of Cd, Cr, and Pb in all packaging sample matrices (for samples digestion with HF, a ceramic torch, alumina injector, and PTFE nebulizer and spray chamber is used). The operating conditions for the ICP-OES system were as follows: RF applied power to the torch, 1.15 kw; auxiliary ow rate, 0.5 L/min; nebulizer ow rate, 0.65 L/min maximum integration time, 30 s, with dual radial-axial view. MICROWAVE SAMPLE PREPARATION Incoming samples for this study included packaging components containing plastics, polymers, printed-paper and cardboard. Routine contract testing also includes food items and enamels, paint and epoxy for commercial jewelry. A microwave method was developed that would provide a complete Typical packaging samples (0.2 g) were placed in disposable glass test tubes and placed in a 15-position rack for the microwave. The samples were treated with a 5 ml nitric acid, 0.5 ml hydrochloric acid combination and the rack placed in the microwave chamber (note: the PTFE liner contains 110 ml of water and 10 ml of hydrogen peroxide as the microwave load for parameter control). Following prepressur ization of the chamber with nitrogen to 40 bar, the samples were digested using the following time-temperature Table I: ICP-OES analysis of a typical mixed packaging sample set; plastics, polymers, printed paper following SRC digestion (0.2 g, nitric acid: 25 min to 250 o C with 15 min at 250 o C.) Spike result 1.912 2.007 1.954 Spike recovery % 95.6 100.4 97.7 Spike duplicate result 1.973 2.073 2.018 Spike duplicate recovery % 98.7 103.7 100.9 Product box m) <1.29 3.24 <1.29 Container seal <1.63 <1.63 <1.63 Outer plastic cap <1.48 <1.48 <1.48 Inner plastic cap <1.39 <1.39 <1.39 Inner cap cardboard <1.48 3.25 <1.48 Label <1.35 6.28 <1.35 Bottle <1.36 <1.36 <1.36 Pet toy bristles (handle) <1.44 Bristles duplicate <1.39 Entree container <1.36 Cardboard <1.46 3.06 <1.46 Plastic <1.46 <1.46 <1.46 Page 3

microwave method: Ramp to 250 o C over 20 min, hold at 250 o C for 15 min, cool to 60 o C and depressurize the chamber for analysis for total time of 50 minutes. To achieve complete digestions for all sample types, two method development digestion runs were performed at 225 o C and 240 o C before the optimized temperature was determined. An example of a typical pro le for the microwave method is shown in Figure 3. All parameters are displayed in real time to ensure high quality, safety, and control. For mixed batches, it is critical that the method account for all sample types. As an example for highly organic samples that are encountered in packaging materials, high temperatures are needed for complete digestion; however, signi cant pressures are generated during the decomposition. During the course of method development for plastic packaging, pressures often reached 100 bar or greater, indicating the importance of choosing conditions that will digest all sample types simultaneously. RESULTS Three separate digestion runs were performed on a variety of mixed packaging samples from commercial sources. Each of the methods described above formed a clear digest, which was diluted with deionized water to 25 ml. These samples were analyzed for Cd, Cr, and Pb using the ICP-OES system. For quality control (QC), laboratory blank,control spikes and duplicates were analyzed as part of ongoing instrument continuing calibration veri cation to go along with periodic sample duplicates. Quantitative data, detection limits, and QC data are shown in Tables I, II, and III. By examining the results, it was easy to determine packaging that required subsequent testing and agging for the customer. Given the high throughput nature of client demand, the standardization of the SRC microwave method aligned well with the use of ICP-OES analysis for a majority of incoming samples. The use of disposable glass vessels, ACS-grade acid and small sample sizes provided a cost effective approach for microwave digestion of ICP-OES analysis. A switch to PTFE or quartz vessels and trace-level acid provides for a path for coupling microwave digestion and ICP- MS analysis for other element panels and lower concentration ranges. CONCLUSION SRC digestion in commercial contract environments for trace metals provided an optimized sample prep method. To achieve complete digestion for all samples ranges simultaneously, an optimized temperature of 250 o C was used following method development iterations at 225 o C and 240 o C. The packaging sample digestions were performed in disposable glass vials to eliminate the need for vessel cleaning in subsequent digestion runs. With a 15 position rack and 50 min digestion time, 3 sets of 12 customer samples, blank, and control spike samples and duplicates were digested and analyzed in a normal working day. Table II: ICP-OES analysis of mixed sample packaging, containers, and lids follwing SRC microwave digestion (0.2 g, 5 ml nitric acid and 0.5 ml hydrochloric acid: 25 min to 250 o C with 15 min at 250 o C) Spike result 1.936 2.047 1.954 Spike recovery % 96.8 102.4 97.7 Spike duplicate result 1.875 1.979 1.893 Spike duplicate recovery 93.8 99 94.7 % Clear plastic 610.33 <1.28 Frosted plastic 570.27 Clear plastic duplicate 613.43 Frosted plastic duplicate 596.22 Outer plastic wrapper <1.44 <1.44 <1.44 Large white backing <1.36 <1.36 <1.36 Inner plastic wrapper <1.37 <1.37 <1.37 Small clear backing <1.28 <1.28 <1.28 Outside package <1.41 <1.41 <1.41 Inside Package <1.42 <1.42 <1.42 Paper back <1.46 3.72 <1.46 Side dish with lid <1.43 Page 4

Standardizing the SRC method with an optimized temperature and choice of vessel material and acid combination enables commercial laboratories to process any combination of customer samples without extensive method development, batching or vessel cleaning and assembly. REFERENCES 1. T. Michel, Breaking the Sample Preparation Bottleneck with a New Approach to Microwave Digestion, American Laboratory 42, 32-35 (2010). 2. J.A. Nobrega, C. Pirola, L.L. Fialho, G. Rota, C.E.K.M.A de Campos Jordao, F. Pollo, Talanta 98, 272-276 (2012). 3. J.A. Norbrega, G.L. Donati, in: R.A. Meyers (Ed.), Encyclopedia of Analytical Chemistry, John Wiley, Chichester (2011). 4. T. Michel and S. Hussain, Spectroscopy supplement: Applications of ICP & ICP-MS Techniques for Today s Spectroscopists, 30-35 (November 2012). Table III: ICP-OES analysis of mixed sample plastic cap, bottle, label packaging follwing SRC microwave digestion (0.2 g, 5 ml nitric acid and 0.5 ml hydrochloric acid: 25 min to 250 o C with 15 min at 250 o C) Spike result 1.886 1.859 1.891 Spike recovery % 94.3 93 94.6 Spike duplicate result 1.849 1.826 1.853 Spike duplicate recovery % 92.5 91.3 92.7 Plastic <1.39 <1.39 <1.39 Cap <1.37 <1.37 <1.37 Bottle <1.34 2.95 <1.34 Label <1.37 <1.37 <1.37 Paper <1.44 2.6 <1.44 Plastic (2) <1.45 <1.45 <1.45 Cap (2) <1.42 <1.42 <1.42 Bottle (2) <1.34 1.72 <1.34 Label (2) <1.38 <1.38 <1.38 Outer Package <1.92 <1.92 <1.92 Wrapper <1.50 <1.50 <1.50 Wrapper <1.36 <1.36 <1.36 Page 5