TIIVISTELMÄRAPORTTI (SUMMARY REPORT)

Similar documents
TIIVISTELMÄRAPORTTI (SUMMARY REPORT)

APPLICATIONS OF THE QUANTUM KEY DISTRIBUTION (QKD) METHOD

Principles and Applications of Neutron Based Inspection Techniques. Tsahi Gozani Rapiscan Laboratories 520Almanor Ave, Sunnyvale, CA

Physics Dept. PHY-503-SEMESTER 112 PROJECT. Measurement of Carbon Concentration in Bulk Hydrocarbon Samples

Pulsed Neutron Interrogation Test Assembly - PUNITA

Design of an Integrated Inspection System For Detection of Explosive and Illicit Materials

Total probability for reaction Yield

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

Fissile material experiments at the Device Assembly Facility

NIGAS. i o n. N B C D e t e c t. The Neutron Induced Gamma Spectrometer

Neutron Based Techniques for the Detection of Illicit Materials and Explosives

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Detection of explosives and fissile material based on neutron generators, survey of techniques and methods. M. Bruggeman

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Detection of Neutron Sources in Cargo Containers

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools

An introduction to Neutron Resonance Densitometry (Short Summary)

A MONTE CARLO SIMULATION OF COMPTON SUPPRESSION FOR NEUTRON ACTIVATION ANALYSIS. Joshua Frye Adviser Chris Grant 8/24/2012 ABSTRACT

A Report On DESIGN OF NEUTRON SOURCES AND INVESTIGATION OF NEUTRON BASED TECHNIQUES FOR THE DETECTION OF EXPLOSIVE MATERIALS

POSITION SENSITIVE DETECTION OF CONCEALED SUBSTANCES EMPLOYING PULSED SLOW NEUTRONS

Medical Neutron Science

1.4 The Tools of the Trade!

First tests of the big volume ultra low background gamma spectrometer

Hands on LUNA: Detector Simulations with Geant4

Quality control of neutron-absorber materials for the nuclear fuel cycle, Principle of the JEN-3 neutron Backscattering gauge

Gamma-Spectrum Generator

Compton suppression spectrometry

Measurements of Neutron Total and Capture Cross Sections at the TOF spectrometers of the Moscow Meson Factory

A Proposal of Nuclear Materials Detection and Inspection Systems in Heavily Shielded Suspicious Objects by Non-destructive Manner.

OXEA - Online Elemental Analyzer

Measurement of Average Thermal Neutron Flux for PGNAA Setup

CHAPTER 5 EFFECTIVE ATOMIC NUMBER OF SELECTED POLYMERS BY GAMMA BACKSCATTERING TECHNIQUE

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

1.5. The Tools of the Trade!

Analyzing the Sensitivity of a Hard X Ray Detector Using Monte Carlo Methods

SCINTILLATION DETECTORS AND PM TUBES

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

6 Neutrons and Neutron Interactions

Recent improvements in on-site detection and identification of radioactive and nuclear material

Determination of the boron content in polyethylene samples using the reactor Orphée

Detection and measurement of gamma-radiation by gammaspectroscopy

PHYS 3650L - Modern Physics Laboratory

Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays

Using Fast Neutrons to Detect Explosives and Illicit Materials

THE INSTALLATION FOR EXPERIMENTAL NEUTRON SPECTRA RESEARCH IN REACTOR MATERIALS COMPOSITIONS Hliustin D.V. Institute for Nuclear Research, Moscow,

The Ones That Got Away: Neutron Leakage Spectra

SCANNING OF CARGO CONTAINERS BY GAMMA-RAY AND FAST NEUTRON RADIOGRAPHY

The Neutronic Check Point: fast neutron transmission measurements to detect explosives in vehicles.

Radioactivity. Lecture 6 Detectors and Instrumentation

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

Department of Chemistry, University of Rochester, Rochester, N.Y POC:

Radionuclide Imaging MII Detection of Nuclear Emission

EEE4106Z Radiation Interactions & Detection

PINS Measurements of Explosive Simulants for Cargo Screening

Today, I will present the first of two lectures on neutron interactions.

Interaction of Ionizing Radiation with Matter

NSD GRADEL FUSION NEUTRON GENERATORS

DETERMINATION OF CORRECTION FACTORS RELATED TO THE MANGANESE SULPHATE BATH TECHNIQUE

Quality Assurance. Purity control. Polycrystalline Ingots

Chapter 3: Neutron Activation and Isotope Analysis

Radioactivity III: Measurement of Half Life.

Measurement of prompt fission γ-ray spectra in fast neutroninduced

DEVELOPMENT OF ADVANCED NEUTRON INDUCED PROMPT GAMMA- RAY ANALYSIS SYSTEM FOR SURVEY OF ANTI-PERSONNEL MINES

Gamma and X-Ray Detection

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

Physics 23 Fall 1989 Lab 5 - The Interaction of Gamma Rays with Matter

New Neutron-Induced Cross-Section Measurements for Weak s-process Studies

Determination of the shielding power of different materials against gamma radiation

ISO INTERNATIONAL STANDARD

Explosives Detection and Identification by PGNAA

Photofission of 238-U Nuclei

Neutron Detection. n interactions with matter n detection High/low energy n detectors

GAMMA DETECTORS FOR High energy Inelastic Neutron Scattering. E.M. Schooneveld

Shielded Scintillator for Neutron Characterization

Simple Experimental Design for Calculation of Neutron Removal Cross Sections K. Groves 1 1) McMaster University, 1280 Main St. W, Hamilton, Canada.

The interaction of radiation with matter

anti-compton BGO detector

arxiv: v1 [physics.ins-det] 26 Jun 2013

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

Chapter Four (Interaction of Radiation with Matter)

NEUTRON TECHNOLOGIES (PAPER II)

Compton Imaging with Coincidence Measurements for Treaty Verification Purposes

Comparison of the Photo-peak Efficiencies between the Experimental Data of 137 Cs Radioactive Source with Monte Carlo (MC) Simulation Data

This paper should be understood as an extended version of a talk given at the

Neutron and Gamma Ray Imaging for Nuclear Materials Identification

CHARGED PARTICLE INTERACTIONS

A Monte Carlo Simulation for Estimating of the Flux in a Novel Neutron Activation System using 252 Cf Source

Activation Analysis. Characteristic decay mechanisms, α, β, γ Activity A reveals the abundance N:

Measurement of Hydraulic Conductivity, Porosity and Lithology by Neutron Activation Borehole Logging at high spatial resolution increments

A Photofission Delayed γ-ray Spectra Calculation Tool for the Conception of a Nuclear Material Characterization Facility

Digital simulation of neutron and gamma measurement devices

Cross-Sections for Neutron Reactions

Gamma-ray emission by proton beam interaction with injected Boron atoms for medical imaging. Giada Petringa - Laboratori Nazionali del Sud -

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons

Unit 3 Atomics Repair Problems

Neutron and gamma ray measurements. for fusion experiments and spallation sources

1 of :32

Reconstruction of Neutron Cross-sections and Sampling

Simulation of nonorganic scintillation detector response for the problems of active interrogation by tagged neutron technology

Transcription:

2015/2500M-0019 ISSN 1797-3457 (verkkojulkaisu) ISBN 978-951-25-2741-0 (PDF) TIIVISTELMÄRAPORTTI (SUMMARY REPORT) Detection of CBRNE materials using active neutron interrogation phase 2 (CBRNE-aineiden havaitseminen neutroniherätteen avulla vaihe 2) Harri Toivonen (HT Nuclear Oy, harri.toivonen@htnuclear.fi), Philip Holm, Ari-Pekka Leppänen, Kari Peräjärvi, Jussi Huikari (Säteilyturvakeskus) Abstract CBRNE substances can be detected using active neutron interrogation. The method is nondestructive and can be used even when the substance is sealed within a package. In the present project, the method was studied empirically in a realistic measurement geometry and light elements were identified. The measurements were performed using grenade shells filled with harmless materials, such as water, salt, fertilizer, and explosives. Californium sources were used as neutron sources. The key result is that the high N/H ratio of the explosives can be detected with thermal neutron interrogation alone whereas fast neutrons are needed for the excitation of C and O, should the device be designed for other security purposes, too. 1. Introduction CBRNE materials (Chemical, Biological, Radiological, Nuclear and Explosive) are a threat to society if they are available for the adversaries. Identifying the substances is crucial for correct countermeasures. The substances can be inside a closed package and it may be desirable to study the content of the package without opening it. Bomb threats and old warheads with unknown content are examples of such scenarios. Active neutron interrogation, or prompt gamma-ray neutron activation analysis (PGNAA) is a nondestructive method for detecting elements and substances (stochiometry). In the present project, the method was studied empirically with a realistic measurement geometry. Presently, only countries with advanced nuclear technology have the expertise and operative systems for active interrogation. In PGNAA, gamma-ray signatures of elements are revealed in neutron-induced reactions (absorption and inelastic scattering). Detecting these gamma-ray signatures with a gamma spectrometer gives information on the elemental contents of the unknown target. The choice of a gamma spectrometer and a neutron source or generator depends on the application. 2. Research objectives and accomplishment plan The project was planned to take two years. In the first year, the suitability of different gamma-ray spectrometers (HPGe, LaBr 3 and NaI) was tested with the purpose of demonstrating the capability to detect and identify CBRNE substances. Neutron generators have advantages as compared to neutron sources, providing high energy neutrons, possibility for pulsed neutron beams (observe prompt and thermalized neutrons), radiation safety advantages (emitting neutrons only when in use) and significantly higher flux compared to conventional sources. In the second year (the present project), measurements with HPGe and LaBr 3 gamma-ray spectrometers were performed with a realistic measurement geometry using a grenade shell. No neutron generator was available for the present studies. Therefore, the measurements were performed with neutron sources ( 252 Cf and AmBe). Postiosoite Käyntiosoite Puhelin s-posti, internet Postadress Besöksadress Telefon e-post, internet Postal Address Office Telephone e-mail, internet MATINE/Puolustusministeriö Eteläinen Makasiinikatu 8 A Vaihde 295 160 01 matine@defmin.fi PL 31 00130 Helsinki www.defmin.fi/matine FI-00131 Helsinki Finland Finland

3. Materials and methods The laboratory measurements were performed using an empty grenade shell with a caliber of about 150 mm. A 40% HPGe gamma-ray spectrometer was used as a detector. A 3 x3 LaBr 3 detector was also used, however, it was deemed useless without a neutron shield 1. The detector was put inside a lead tube for gamma shielding. The tube shielded the detector from background radiation and provided some collimation in favour of the grenade. See Figure 1 for the measurement geometry where A is the grenade filled with substance under interrogation, B is the plastic shield housing the neutron source and C is the HPGe detector housed inside a lead shield. The target materials put inside the grenade shell were table salt, water and nitrogen-rich fertilizer. In phase 1 of the project, the same materials were used without the grenade shell and a different measurement geometry. A 252 Cf source emitting 1.1 10 6 neutrons per second was used. A plastic moderator with a hole in the front side was used to have both fast and thermal neutrons incident on the target. Figure 1. Measurement setup. The grenade shell filled with materials under scrutiny is in the middle (A) partially submerged into the table, the neutron source is inside the white plastic tube supported with black plastic ring (B), the detector system is housed inside a lead casing which is inside aluminium tube (C). The measurements were repeated with a hexogen-aluminum grenade. Hexogen (C 3 H 6 N 6 O 6 ) contains 38% nitrogen and can thus be identified as an explosive by studying nitrogen and hydrogen related peaks in the neutron-induced gamma spectrum. 4. Results and discussion Gamma-ray signatures of nitrogen, chlorine and hydrogen were identified in the analysis. Carbon and oxygen were also present, but were not identified. Carbon and oxygen can only be detected by using fast neutrons for the excitation of the target material. Unfortunately, the 252 Cf source does not emit enough fast neutrons for the detection of these el- 1 This is because of the neutron reactions with the scintillator material cause an unwanted background in the measured gamma spectrum.

ements. Figures 2, 3 and 4 present the measured spectra and characteristic gamma peaks of different elements. The results are summarized in Appendix 1. Figure 2. Signature of chlorine in a 3.4 h measurement with a 9.4 MBq Cf-252 source and HPGe detector. Chlorine emits a 6120 kev photon in a neutron capture reaction. The target was the grenade shell filled with nitrogen fertilizer (containing 10 w-% chlorine). Figure 3. Signature of nitrogen in a 3.4 h measurement with a 9.4 MBq Cf-252 source and HPGe detector. Nitrogen emits a 10.8 MeV photon in a neutron capture reaction. The target was the grenade shell filled with nitrogen fertilizer (containing 27 w-% nitrogen).

Figure 4. Signature of hydrogen in a 3.4 h measurement with a 9.4 MBq Cf-252 source and HPGe detector. Hydrogen emits a 2223 kev photon in a neutron capture reaction. The target was the grenade shell filled with nitrogen-rich fertilizer (containing 4 w-% hydrogen). Part of the peak area is due to the hydrogen in the neutron source moderator. The laboratory measurements provided basic understanding on the order of magnitude of the detection efficiency in the given, realistic measurement geometry. The detector setup failed during the hexogen grenade measurements and thus no conclusions can be drawn from those measurements results. However, there is more nitrogen in the hexogen grenade (1.9 kg) than in the fertilizer measurements (0.95 kg), and the nitrogen is thus in theory detectable with the current setup. For operational use, the system must be designed to deliver results within a short time span. This can be achieved with a neutron generator which would provide 10 6 neutrons in a pulse with duration of one microsecond, and repeated with a frequency of 100-1000 Hz. The short pulses reduce the background significantly, and they separate thermal and fast neutron signatures from each other which is a great advantage in the spectrum analysis. Efficient use of such pulsed neutron sources requires the adoption of digital listmode data acquisition where detected gamma-rays are stored as time stamped events. Time resolution of the system should be at the sub-µs level. In addition, the same data acquisition system would also record neutron generator s beam on/off duty cycles. All this would be made on a time synchronized manner. The neutron generator also makes neutron imaging possible which is the key requirement for studying unknown objects. Other design necessities were also identified. A thick gamma shield is required between the neutron source moderator and the detector to absorb all of the photons emitted by neutron capture reactions in the moderator. Otherwise these are indistinguishable from the same reactions in the target material. Also, the detector should be coated with a neutron absorber, such as boron, to minimize neutron reactions inside the detector. Such a neutron shield may make the LaBr 3 a valid option.

5. Conclusions The feasibility of the active neutron interrogation method was demonstrated to detect elements without opening the package. The resolution and efficiency of a high-efficiency HPGe detector combined with the advantages of a neutron generator provide the ability to detect CBRNE elements in an operational environment. 6. Scientific publishing and other reports produced by the research project 1. KET-TECOC-2015 ACTI 2015: Active Interrogation of an Ammunition Shell Filled with Innocent Materials, P. Holm, A.-P. Leppänen, K. Peräjärvi, H. Toivonen 2. KET-TECDOC-2015 ACTI 2015: Active Interrogation of Hexogen Grenade, P. Holm, J. Huikari, K. Peräjärvi, A.-P. Leppänen, H. Toivonen

APPENDIX 1: Gamma-ray signatures of the target materials The following tables present some of the gamma-ray signatures of the elements measured in the present project, as well as information on whether the signature was detected in the measurements or not. Nuclide H-1 2223 (n,g) Yes Nuclide C-12 4438 (n,n g) No Nuclide N-14 730 (n,n g) No 1634 (n,n g) No 1885 (n,g) No 2313 (n,n g) No 5269 (n,g) No 5298 (n,g) No 10829 (n,g) Yes

Nuclide O-16 5618 (n,n g) No 6129 (n,n g) No Nuclide Cl-35 788 (n,g) No 1165 (n,g) No 1763 (n,n g) No 1952 (n,g) Yes 1959 (n,g) Yes 6111 (n,g) Yes 7414 (n,g) No 7790 (n,g) No

APPENDIX 2: GEANT4 simulation Figure 5. Geant4 simulation geometry with a phlegmatized hexogen-aluminium grenade, HPGe detector and neutron source moderator. The violet line represents a neutron path. Figure 6. Simulated spectra showing the effect on the 2223 kev photo-peaks detected by the HPGe detector and emitted by hydrogen in a neutron capture reaction. Doubling the detector collimator thickness makes the peak area significantly smaller. This is mostly because the collimator shields the detector from photons emitted by the neutron moderator. Note that the simulated spectrum does not take into account the resolution of the detector