MIXING STATIONS VOLUMETRIC MIXING STATIONS GRAVIMETRIC MIXING STATIONS GRAVIMETRIC DOSING-/MIXING STATIONS

Similar documents
X Series 2 Continuous

Motors Automation Energy Transmission & Distribution Coatings. Servo Drive SCA06 V1.5X. Addendum to the Programming Manual SCA06 V1.

1) Batching Methods (Add Weigh or Loss In Weight) based on batch dispensing time, time between batches, head room, floor space, accuracy and budget.

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

NR ROTARY RING TABLE: FLEXIBLE IN EVERY RESPECT

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

SVH with HYDROVAR (HVL range)

473 Dew Point Hygrometer

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Particle Analysis at the Touch of a Button. Litesizer series

RCA cleaning: SC1, SC2, DHF, BOE, SPM

ISEmax CAM40/CAS40. Technical Information

ROTANTA 460/460 R Benchtop, Underbench and Floorstanding Centrifuges classic/cooled

Software BioScout-Calibrator June 2013

VK2 volume flow controller Overview

Air velocity & IAQ measuring instruments

GS4000 DATASHEET JUNHO 2013

Information Technology Solutions Neptune Datasheet

PRODUCT SPECIFICATIONS

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Digital Thermal Mass Flow Meters and Controllers for Gases

Air velocity & IAQ measuring instruments

473 Dew Point Hygrometer

CoriolisMaster FCB/FCH150 and FCB/FCH450 Simultaneous recording of flow rate and density / concentration for the food and beverage industry

Mercury Stack Monitor SM-4

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

473-SHX Dew Point Mirror

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

PERSPECTIVE STABLE ISOTOPE RATIO MS

Application Your benefits

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

Perseverance. Experimentation. Knowledge.

Residual Chlorine Monitor

Kjeltec 2300 Analyzer Unit

Figure 1 Enlargement of Powdered Activated Carbon by microscope.

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

I n t h e a i r, o n l a n d,

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

Technology that counts

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

610,- KERN ADB. Analytical balances. Quick-Finder Analytical balances. Large glass draught shield with 3 sliding doors

IRMS. perspective. Isotope Ratio Mass Spectrometry.

MDR 3000 Professional Professional Moving Die Rheometer. Testing instruments. Laboratory Equipment. Software systems. Service.

High Capacity Double Pillar Fully Automatic Bandsaw. p h a r o s 2 8 0

Your Partner in Environment Monitoring

QUANTUM Terahertz. Terahertz wall thickness measurement in the plastics industry

The Claviature of Gas Analysis

Applications SC

PRODUCT SPECIFICATIONS

Smartmix X2 The mixing unit on the right move

14:1400 (0206) KRAL Volumeter - OMG

Electrolysis System CHLORINSITU V (PLUS)

PERSPECTIVE STABLE ISOTOPE RATIO MS

TPM(A) Quick Startup Guide SIEMENS SINAMICS S120

Defining quality standards for the analysis of solid samples

PROCESS CONTROL BASIS FOR A COST-EFFECTIVE SELECTIVE SOLDERING PROCESS

Energy saving in electromechanical equipment with power coefficient correction. Dimitris Al. Katsaprakakis Aeolian Land S.A.

FAVIMAT (AI)ROBOT2 FAVIGRAPH. Automatic Single-Fibre Testers

SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 50 Hz

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

7th ESA Workshop on Advanced Space Technologies for Robotics and Automation 'ASTRA 2002' ESTEC, Noordwijk, The Netherlands, November 19-21, 2002

Quantos GraviPrep. Bye Bye, ml Hello, Quantos

+ + ( indicator ) + (display, printer, memory)

QDTL. Liquid Mass Transfer and Diffusion Coefficient Unit PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console

NEW! PCR next to me. Eppendorf Mastercycler nexus: combine, connect, control

FlexSQUARE Square shaped beacons

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser

Multi-level dosing and preact self-adaption correcting automatic batch control model

Magnetic Property Measurement System

The first address for Titration. TITRONIC 300 and TitroLine 5000

PiB Series. PiB (Pump-in-a-Box) 4380 & 4392 Series

16 Appendix 16 Electrical Research Association Report

CyFlow Ploidy Analyser & CyFlow Space High-resolution DNA analysis

TRAM LINE SWITCH POINT HEATING

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

HD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION

CTC 155 / 350 / 660 Dry-block calibrator

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

AF SERIES AWEA MECHANTRONIC CO., LTD. High Performance Vertical Machining Center AGENT ISO 9001 ISO 14001

Technology that counts

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class #

Baltimore Aircoil Company w w w. B a l t i m o r e A i r c o i l. c o m

NEW!! Reliable Chlorine Monitoring. Online Residual Chlorine Monitor. Detailed Specifications. Clean Water through Innovative Technology

Design Considerations for a Variable Angle Absolute Reflectance Accessory For the LAMBDA 950/850/650 UV/Vis/NIR and UV/Vis Spectrophotometers

Analysis of domestic sludge using the Agilent 4200 MP-AES

The Clinical Chemistry System that offers more so you do less!

The Plus for your lab!

NEC PerforCache. Influence on M-Series Disk Array Behavior and Performance. Version 1.0

Advanced Yarn Control Solutions DIAPER TECHNOLOGY LINE

Atomic Absorption Spectrometer ZEEnit P series

Barograph 1.080x

Control Your Product Quality by Controlling Your Product's Conveying Velocity

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

Gravimetric coal dust firing and dry lignite firing in power plants

Chloromax CCS142D. Technical Information

W 34: Sensor technology that does justice to demanding requirements

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

Technology that counts

Transcription:

MIXING STATIONS VOLUMETRIC MIXING STATIONS GRAVIMETRIC MIXING STATIONS GRAVIMETRIC DOSING-/MIXING STATIONS

Subject to alterations, even without advance notice. Measurements and data without obligation. PLASTICOLOR Mixing stations Overview...4 PLASTICOLOR Mixing stations Structure...6 PLASTICOLOR Volumetric and gravimetric mixing stations... 8 Benefits of PLASTICOLOR Mixing stations... 11 PLASTICOLOR Gravimetric dosing-/mixing stations...12 Mounting possibilities of PLASTICOLOR Mixing stations... 14 PLASTICOLOR-Mixing stations 3

PLASTICOLOR MIXING STATIONS OVERVIEW The quality of end products consisting of different material components like main materials, regrinds and additives, for example, is highly dependent on precise dosing, high levels of consistent mixing quality and compliance with the recipe as well as avoiding external influences. In the case of materials whose size and density are very different, in particular, a driven mixer with moving parts frequently results in a poor quality mixing result and possibly even in separation processes. When manufacturing high-quality, technically demanding products, this can lead to considerable variations in quality. With PLASTICOLOR volumetric and gravimetric mixing stations, the main component is also dosed and all of the components that are involved in mixing are fed together to a static mixer at the same time. This ensures both that dosing is exact and that the individual components are mixed well - regardless of the variations in the amount of material that the processing machine takes in. In a project meeting with exact analysis of the requirements profile, we work out whether a volumetric or gravimetric system based on the loss-in-weight principle is most suitable. Standard mixing stations consist of 2 to 8 PLASTICOLOR units. Special mixing stations for more than 8 components can be designed and supplied. In the same way as with all PLASTICOLOR units, mixing stations have a modular structure. You can extend existing mixing stations and change them over from volumetrics to gravimetrics at any time. You can operate PLASTICOLOR mixing stations in starve feeding mode as well as from a full hopper. In starve feeding mode, the fill level is controlled by means of manual set value specification or by synchronising with the processing machine. Operating from a full hopper is possible with a neckpiece tube. In this connection, appropriate sensor technology keeps the amount of pre-mixed material as low as possible while maintaining consistently high mixing quality - regardless of the variations in the amount of material that the processing machine takes in. Depending on your intended purpose, a number of different control variations are available that we have developed ourselves. PLASTICOLOR mixing stations and systems are basically simple, convenient and easy to operate on an intuitive basis. 4 PLASTICOLOR-Mixing stations

PLASTICOLOR VOLUMETRIC MIXING STATION PLASTICOLOR GRAVIMETRIC MIXING STATION PLASTICOLOR GRAVIMETRIC DOSING-/MIXING STATIONS PLASTICOLOR-Mixing stations 5

PLASTICOLOR MIXING STATIONS STRUCTURE The main components of PLASTICOLOR mixing stations are the mixing station neckpieces, PLASTICOLOR dosing units, the material conveying and, with gravimetric mixing stations, a weigh hopper assembly. Different variations of all of the components are available. Depending on your application, you can combine them and match them to your individual production process in an optimum way. PLASTICOLOR NECKPIECES There is a large selection of different neckpieces, depending on the material which is to be mixed, the ratio between the materials and the required output. PLASTICOLOR DOSING UNITS PLASTICOLOR dosing units are mounted at the neckpiece. Four PLASTICOLOR dosing units are available that have a wide range of accessories and a dosing capacity ranging from 70 g to 3,500 kg/h. 6 PLASTICOLOR-Mixing stations

PLASTICOLOR MATERIAL FEED The material storage and feed, e.g. the storage hopper or the hopper loader, are mounted onto the PLASTICOLOR device. PLASTICOLOR WEIGH HOPPER ASSEMBLIES Gravimetric systems are additionally fitted with a weigh hopper assembly. Depending on the production requirements different weigh hopper assemblies are available. Some of them are patented. PLASTICOLOR-Mixing stations 7

PLASTICOLOR VOLUMETRIC AND GRAVIMETRIC MIXING STATIONS 8 7 6 6 4 5 4 5 Volumetric mixing station 1 - Production maschine 2 - Neckpiece 3 - Min/Max Sensors 4 - Static Mixer 5 - Dosing unit 6 - Storage hopper 3 2 1 Gravimetric mixing station 1 - Production maschine 2 - Neckpiece 3 - Min/Max Sensors 4 - Static Mixer 5 - Dosing unit 6 - Weigh hopper assembly 7 - Storage hopper 8 - Hose connector (as an alternative to 7) 3 2 1 8 PLASTICOLOR-Mixing stations

With volumetric mixing stations, PLASTICOLOR devices dose all of the materials including the main material simultaneously. This makes dosing independent of changing throughput rates of the production machines. Depending on the fill level, two sensors in the neckpiece switch all of the devices on and off at the same time by means of a ramp. An integrated colour change system is possible. Gravimetric mixing stations have the same basic structure as volumetric ones. Each PLASTICOLOR unit is additionally fitted with a weigh hopper assembly. PLASTICOLOR gravimetric mixing stations work according to the lossin-weight principle. In this connection, the system collects the weight of each individual component by means of an installed electronic load cell. Each of the components is regulated permanently at the same time to the desired percentage share of the overall mixture. In this way it is possible to produce high-quality products while minimising the materials that are used. Quantity tests are not necessary. The loss-in-weight process is considerably more precise compared to gain-in-weight systems (batch gravimetric). In these systems, every single component is weighed one after the other in one container. In the case of gravimetric mixing stations, the system acquires material consumption and saves recipes. In addition to this, log files record any machine standstills, parameter changes and faults. This documents the complete production process and it can be archived. The PLASTICOLOR mixing station concept including dosing of the main component offers processing companies homogeneous pre-mixing by means of a static mixing insert that is designed for material types and output capacity. constantly consistent feeding of the set recipe components. The mixing station runs independently of the processing machine s current material consumption. Controls for volumetric mixing stations: PDC modular controls series / PPM Control System Controls for gravimetric mixing stations: PPM Control System; possible to connect to any common bus systems, e.g. Modbus, Profibus, TCP/IP, ProfiNet, CANopen, EtherNet/IP etc. PLASTICOLOR-Mixing stations 9

PLASTICOLOR MIXING STATIONS - EXAMPLES 10 PLASTICOLOR-Mixing stations

BENEFITS OF PLASTICOLOR MIXING STATIONS High dosing precision by state-of-the-art electronics and mechanics (approx. +/- 0.5% or better) Extremely few premixed material residuals during sudden production changes No separation Extreme mixing rations possible, e. g. 1 : 2,000 A very good reproducibility Recipe storage Extensive monitoring functions, e. g. level alarm, monitoring of throughputs, an informative alarm system High reliability, even under the toughest conditions Field-tested and practicable options for many applications Complete listing of all operational data and faults Exact recording of all consumption data and production processes All standard mixing station components and spares immediately available from stock PLASTICOLOR-Mixing stations 11

PLASTICOLOR GRAVIMETRIC DOSING-/MIXING STATIONS With gravimetric dosing/mixing stations, the main component flows freely into the extruder. The system is continously dosing each additive by an individual PLASTICOLOR dosing unit into the freely flowing main material. This means 7 that you can exactly dose very small amounts in gravimetric operation. Controls for gravimetric mixing stations: 6 PPM Control System; possible to connect to any common bus systems, e.g. Modbus, Profibus, TCP/IP, ProfiNet, CANopen, EtherNet/IP etc. The PLASTICOLOR mixing station concept without dosing of 4 5 4 the main component offers processing companies the following benefits: Achieving a homogeneous pre-mix by closely combining the materials to be dosed by optimizing the neckpiece heads based on the respective materials and output capacities. The mixing station runs in dependence on the processing machine s current material consumption. The wide RPM 3 range motors of the stations with a wide control range follow the throughput rate of the production system. This means 2 that precise compliance with the set recipe components is guaranteed at all times. 1 - Production maschine 2 - Neckpiece 3 - Dosing unit 4 - Weigh hopper assembly 5 - Main material hopper 6 - Storage hopper 7 - Hopper loader 1 Separation is avoided by bringing together the materials just before they are fed into the production machine. Contamination of the material mixture is prevented by means of a metal or magnetic separator that can be integrated. Very compact structure 12 PLASTICOLOR-Mixing stations

PLASTICOLOR-Mixing stations 13

MOUNTING POSSIBILITIES OF PLASTICOLOR MIXING STATIONS... next to the production machine*... mounted directly on the machine feed opening... as a central mixing station * not for gravimetric dosing/mixing stations 14 PLASTICOLOR-Mixing stations

Woywod production site in Seefeld Woywod Kunststoffmaschinen GmbH & Co. Vertriebs-KG Head Office: Bahnhofstraße 110 82166 Gräfelfing Germany Tel.: +49 89 854 80-0 Fax: +49 89 854 13 36 Internet: www.plasticolor.de E-Mail: woywod@plasticolor.de Factory: Niederlassung Seefeld Lindengasse 2-4 16356 Werneuchen OT Seefeld Germany Tel.: +49 33398 696 3-0 Fax: +49 33398 696 3-1336 E-Mail: woywod.seefeld@plasticolor.de Woywod Kunststoffmaschinen GmbH & Co. Vertriebs-KG