Mechanisms of Erosion-Corrosion in Well 311D, South Sambaloran, Leyte Geothermal Production Field

Similar documents
PERFORMANCE EVALUATION OF DEEPENED WELLS 420DA AND 517DA IN THE LEYTE GEOTHERMAL PRODUCTION FIELD, PHILIPPINES

Update on the Stable Isotope Geochemistry of the Leyte Geothermal Production Field

Calcite Scale Inhibition: The Case of Mahanagdong Wells in Leyte Geothermal Production Field, Philippines

GAS EQUILIBRIA CONTROLLING H 2 S IN DIFFERENT PHILIPPINE GEOTHERMAL FIELDS

Repeat Microgravity and Leveling Surveys at Leyte Geothermal Production Field, North Central Leyte, Philippines

The Resistivity Structure of the Mahanagdong Geothermal Field, Leyte, Philippines. Carlos F. Los Baños and Felix C. Maneja

MINERAL SCALING IN GEOTHERMAL TWO-PHASE PIPELINES

6th European Sand Management Forum, March 2014, Aberdeen

Investigation into Sand Deposition and Transportation in Multiphase Pipelines Phase 2

Chapter 5 Control Volume Approach and Continuity Equation

CALCITE INHIBITION IN THE AHUACHAPAN GEOTHERMAL FIELD, EL SALVADOR

Systematics of Rare Alkalis and Halogens in the High-Temperature Mahanagdong Geothermal Field, Leyte, Philippines

White Paper FINAL REPORT AN EVALUATION OF THE HYDRODYNAMICS MECHANISMS WHICH DRIVE THE PERFORMANCE OF THE WESTFALL STATIC MIXER.

Erosion Testing & CFD Erosion Modelling. John Peters, NEL, 29 January 2014

The Design of Gating System 3. Theoretical considerations in gating design

Overall Heat Transfer Coefficient

THE GEOTHERMAL POTENTIAL OF BILIRAN ISLAND, PHILIPPINES

1. Introduction. 1.1 Overview of Study:

Acoustic Resonance in Main Steam Line Side Branches

Principles of Food and Bioprocess Engineering (FS 231) Problems on Heat Transfer

A drop forms when liquid is forced out of a small tube. The shape of the drop is determined by a balance of pressure, gravity, and surface tension

Pumping Stations Design For Infrastructure Master Program Engineering Faculty-IUG

THREE DIMENSIONAL NUMERICAL MODELING OF MINDANAO GEOTHERMAL PRODUCTION FIELD, PHILIPPINES

Lesson 7: Thermal and Mechanical Element Math Models in Control Systems. 1 lesson7et438a.pptx. After this presentation you will be able to:

Heat and Mass Transfer Unit-1 Conduction

Piping Systems and Flow Analysis (Chapter 3)

GENERAL PHYSICS (3) LABORATORY PHYS 203 LAB STUDENT MANUAL

Learning objectives: 1)To describe the principle behind tapping of Geothermal energy 2)To indicate limits and challenges with Geothermal energy usage

DETERMINATION OF DISCHARGE AND HEAD LOSS USING A FLOW-MEASURING APPARATUS

B-1. Attachment B-1. Evaluation of AdH Model Simplifications in Conowingo Reservoir Sediment Transport Modeling

Level 7 Post Graduate Diploma in Engineering Heat and mass transfer

INTERPRETATION OF INTERFERENCE EFFECTS IN THREE PRODUCTION WELLS IN THE KAWERAU GEOTHERMAL FIELD, NEW ZEALAND. Lynell Stevens and Kevin J Koorey

CHAPTER 3 MODELLING AND ANALYSIS OF THE PACKED COLUMN

PHYSICAL MECHANISM OF CONVECTION

Experiment- To determine the coefficient of impact for vanes. Experiment To determine the coefficient of discharge of an orifice meter.

Chapter: Heat and States

Tutorial 1. Where Nu=(hl/k); Reynolds number Re=(Vlρ/µ) and Prandtl number Pr=(µCp/k)

VALIDATION AND IMPROVEMENT OF SPPS IN LOW LIQUID LOADING AND ANNULAR FLOW

Summer School in Glaciology, Fairbanks/McCarthy, Exercises: Glacial geology

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

Department of Energy Fundamentals Handbook. THERMODYNAMICS, HEAT TRANSFER, AND FLUID FLOW, Module 3 Fluid Flow

1. Introduction. Technical presentation of the Bernoulli Filter

Solid Particle Erosion in Slug Flow. Introduction

Cavitation Control on Hydrofoils

12 Moderator And Moderator System

Water Circuit Lab. The pressure drop along a straight pipe segment can be calculated using the following set of equations:

Numerical Analysis of Transient Steam-Water Two-Phase Flow in Geothermal Production Wells with Multiple Feed Zones

Sustainable Energy Science and Engineering Center GEOTHERMAL ENERGY. Sustainable Energy Sources. Source:

Product Data Sheet PD-0037-B

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Annubar Primary Element Flow Calculations

Pressure and Flow Characteristics

Heat Transfer Analysis of Machine Tool Main Spindle

FLOW BOILING HEAT-TRANSFER IN PLATE MICRO- CHANNEL HEAT SINK

What Do You Think? Investigate GOALS. Part A: Precipitation of Calcium

Laboratory work No 2: Calibration of Orifice Flow Meter

About the Calibration of Rotameter

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

THE GEOTHERMAL TWO-PHASE ORIFICE PLATE

EROSION ANALYSIS FOR THE MISALIGNED U2 NOZZLE AND ITS CONNECTOR BLOCK

Countercurrent heat exchanger

Product Data Sheet PD-0053-A

FLOW MEASUREMENT IN PIPES EXPERIMENT

Numerical Simulation Study of the Mori Geothermal Field, Japan

Geochemical Modeling of Acidic Geothermal Fluids using SOLVEQ and CHIM-xpt

Thermal properties of Engineering Materials

Two mark questions and answers UNIT I BASIC CONCEPT AND FIRST LAW SVCET

Series 7500 Formed Metal Bellows Catalog 974C

Stream Entrainment, Erosion, Transportation & Deposition

9. Pumps (compressors & turbines) Partly based on Chapter 10 of the De Nevers textbook.

CASE STUDIES. Introduction

Principles of Convection

Energy flows and modelling approaches

GEOTHERMAL BOREHOLE INVESTIGATIONS DURING AND AFTER DRILLING

JDV CONTROL VALVES CO., LTD. JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual

Using Repeat Microgravity Measurements to Track Reinjection in Liquid-Dominated Fields

MECHANISM BEHIND FREE /NATURAL CONVECTION

Fatigue Life Estimation of Piping System for Evaluation of Acoustically Induced Vibration (AIV)

Experiment (4): Flow measurement

Simulating leakage through well cement: coupled reactive flow in a micro-annulus

Early Identification and Management of Calcite Deposition in the Ngatamariki Geothermal Field, New Zealand

Complex Compounds Background of Complex Compound Technology

Prediction of Calcite Scaling at the Oguni Geothermal Field, Japan: Chemical Modeling Approach

Principles of Food and Bioprocess Engineering (FS 231) Exam 2 Part A -- Closed Book (50 points)

ch-01.qxd 8/4/04 2:33 PM Page 1 Part 1 Basic Principles of Open Channel Flows

U-Shaped Sediment Traps

Therefore, the control volume in this case can be treated as a solid body, with a net force or thrust of. bm # V

TransCanada / Daniel Using Advances Diagnostics to Identify Measurement Uncertainties

Velocity Measurement in Free Surface Flows

Pipe Flow. Lecture 17

The Sandbox Project 1 cm 10 m

`Transient conjugate heat transfer analysis of a turbocharger

Fluid Dynamics Midterm Exam #2 November 10, 2008, 7:00-8:40 pm in CE 110

Ways to Improve the Energy Efficiency of AN Solution Plants

Storm Sewer Design [2]

External Pressure... Thermal Expansion in un-restrained pipeline... The critical (buckling) pressure is calculated as follows:

Subsurface Characterization of the Leyte Geothermal Field, Philippines using Magnetotellurics

Outlines. simple relations of fluid dynamics Boundary layer analysis. Important for basic understanding of convection heat transfer

CCR Rule Annual Inspection Report (cont.) 2

Transcription:

Proceedings World Geothermal Congress 010 Bali, Indonesia, 5-9 April 010 Mechanisms of Erosion-Corrosion in Well 311D, South Sambaloran, Leyte Geothermal Production Field Erlindo C. Angcoy, Jr., Archibald L. Abarquez, Romeo P. Andrino, Garry F. Cañete, Melvin D. Lledo, Christine H. Siega and Ruperto R. Villa, Jr. Energy Development Corporation, Energy Center, Merritt Road, Fort Bonifacio, Taguig City, Philippines angcoy.ec@energy.com.ph Keywords: erosion, corrosion, steam-dominated well 1. INTRODUCTION Continuous exploitation of the Tongonan Geothermal Field shifted the discharges of the production wells from liquiddominated to steam-dominated, manifested by the vertical and lateral expansions of the steam zone (Salonga et al., 00). The dry well discharges also contained total suspended solids (TSS) >5 ppm. In the absence of an insitu waterflow to scrub the solids, erosion-corrosion of twophase and steam lines were initially observed in Tongonan1 in 000 (Villa and Salonga, 001) then expanded to Upper Mahiao in the north and South Sambaloran to the south. ABSTRACT Well 311D, a steam-dominated production well in Leyte geothermal field discharging suspended solids, manifested erosion-corrosion failures in its wellbore and surface facilities. The suspended solids, initially consisting of formation materials, erode the layer of corrosion products formed when well discharge was still water-dominated. A caliper survey to check its casing integrity calculated a thinning rate of 0.6 mm/yr. Also, its wellhead assembly experienced recurring damage located between the mating flange connection of the expansion spool and master valve and confined along the wingports. The damage is attributed to the combined effects of flow patterns within the wingports, the suspended solids in the flowing stream and any stresses induced by wellhead vertical movements exceeding the design limit. In the branchline, erosioncorrosion is also observed in areas where high heat-loss occurs and in rough edges or protrusions of tapping points welded portions. Un-insulated facilities in the branchline, act as heat sinks forming condensates that absorb corrosive gas species. The mixing of dry well 311D and two-phase well 309D discharges creates intermittent cavitation causing bubbles or mists to collapse in the walls and damage a limited section of the two-phase header within the mixing point. Well 311D was spudded in 1996 as an in-fill large-diameter production well in Pad 300B, South Sambaloran (Fig. 1) drilled to a total measured depth of 87 m. The well has stable downhole measured temperatures of 50-70 C, is operated at high wellhead pressure of 1. MPag and delivers 10-18 kg/s of dry discharge (H= 780 J/g) with typical TSS level of 10 ppm (with range of - ppm). In ~10 years of well utilization, well 311D exhibited numerous erosion and corrosion phenomena from the wellbore to the downstream surface facilities, some of which were not observed in similar dry wells with elevated TSS levels. Figure 1: Map of Tongonan Geothermal Field 1

. OCCURENCES OF EROSION AND CORROSION Documented problems in the above-surface facilities connected to well 311D include: (1) recurring leaks and damages of the wellhead assembly, () fast thinning in sections of the sweepbend and branchline based on Ultrasonic Thickness (UT) measurements, (3) fast thinning and localized corrosion/pitting in the two-phase header, (5) leaks and damages in flange connections and (6) leaks in tapping points of sampling provisions and bypass line..1 Production Casing Thinning To determine the wellbore condition, casing inspection by caliper survey was conducted in May 007 using a 60-arm caliper capable of taking 60 simultaneous inner diameter (ID) measurements at a minimum sampling rate of one data set per 3 inches of tool movement (Buñing et al., 005). The tool can operate at T max = 315 C and records only the maximum and minimum readings. Casing thinning calculated throughout the survey depth was 0.-0.5 inch in its 10 years of utilization (0.6 mm/yr). Thinning worsens as the log goes deeper and as the wellbore deviates. The calculated thinning rate is higher than the acceptable 0.1 mm/yr (3 mm/5 years) but is less than the rates in surface facilities typically at mm/yr in Pad 301 of South Sambaloran (Angcoy et al., 005) and at 18 mm/yr in Tongonan-1 (Villa et al., 005). At a consumption rate of 0.6 mm/yr and on the worst scenario that fluid attacked the anchor casing since utilization in 1997, it will take another.9 years before critical thickness is reached at MPag internal pressure. The erosional velocity of the fluid inside the casing was evaluated based on the formula of Salama (000) for sandladen fluids (equation 1). V erosional (D ρ ) m = (1) (0 W ) where V is the erosional velocity (m/s), D is the pipe inside diameter (mm), ρ m is the fluid mixture density (kg/m 3 ), and W is the sand flow rate (kg/d). Flow calculations summarized in Table 1 (based on equation 1) show that a 311D total mass flow of 10 kg/s will have a velocity inside the 13-3/8 production casing (7 m/s) exceeding the erosional velocity (6 kg/s) if the TSS level is 5 ppm. If 311D total mass flow reaches 18 kg/s, then erosional velocity (10 kg/s) is exceeded at a lower TSS level 8 ppm. Both cases are valid based on historical discharge characteristics of 311D. Thus, thinning of the production casing results from alternate corrosion (between metal and geothermal fluid) and erosion of bare metal and passive films by suspended solids. The suspended solids are initially formation materials that pass through the slotted liner and trigger the removal of protective passive films formed inside the well when 311D water phase was still present. The discharge chemistry of 311D in 1998 when plotted in a Pourbaix diagram shows formation of corrosion products that form the passive films (Fig. ). Table 1. Summary of Erosional Velocities in Wellbore. Casing type Total Mass Flow = 10 kg/s Velocity Erosional velocity inside with TSS level casing (m/s) Total Mass Flow = 18 kg/s Velocity Erosional velocity inside with TSS level casing (m/s) 5 ppm 5 ppm 5 ppm 8 ppm 13 3/8" 7 19 6 1 1 11 9 5/8" 13 1 5 3 10 8 Eh (Volts).0 - S - HO - System at 188.00 C 1.5 O3 1.0 0.5 0.0-0.5 (+a) S S -1.0 3O -1.5 -.0 0 6 8 10 1 HO Limits 1 C ph ELEMENTS Molality Pressure 1.0E-03 1.180E+01 Dec 1998 S 6.560E-0 1.180E+01 Figure : Pourbaix diagram of historical highly two-phase well 311D discharge chemistry.

. Wellhead Assembly Damages In the wellhead assembly of well 311D, recurring damage was documented in the mating flange connections of the expansion spool and master valve confined along the two opposing wingports (Fig. 3) and could be attributed to the combined effects of flow patterns within the wingports and the suspended solids in the flowing stream. This can be aggravated by stresses due to wellhead vertical movements beyond the design limit that may be experienced during changes in well operating conditions either due to throttling or variations in mass flow. Thus the wellhead assembly leaks were usually observed during preventive maintenance periods. Original WHA LEAK POINT 1 Master Valve Damaged WHA Expansion Spool LEAK POINT Figure 3: Damages in wellhead assembly (WHA) of well 311D (not drawn to scale). Flow is altered as the fluid passes through the 3-1/8 diameter wingports that induce eddy currents downstream (Fig. ). Thus, suspended solids and mists in the fluid are drawn towards the wall and attack the metals downstream and along the wingports. The flange face has a conservative thickness allowance of 3 inches, before metal loss propagates outwards into the groove and the seal ring. At a thinning rate of 0.5 inch/10 yr, no leak is expected to develop in the mating flange connections for a long time provided that the mating flange connections are in static equilibrium. This equilibrium may be upset if the wellhead of well 311D vertically moves above the design limit (± 6 inches) that can induce branchline stresses which can no longer be compensated by pipe support systems. As such, the resulting stressed points along the wingport become vulnerable to erosion-corrosion leading to leaks since a pressure gradient draws the high velocity steam, corrosive mists and suspended solids towards the stressed and worn points aggravating the localized metal losses..3 Branchline Leaks The dominant mechanism of mechanical erosion by suspended solids cause accelerated thinning rates in the sweepbend and the branchline based on UT monitoring data. High thinning rate in the sweepbend is influenced by the angles (10-0 ) at which the suspended solids impact the walls. In the branchline, the increased rates are highly correlated with location of high turbulence (i.e., reducer and near the branchline stub-in point to two-phase header). Leaks in the tapping points of bypass lines and vents are due to the combined effects of (1) solids erosion due to turbulence downstream of tapping points (Fig. 5, striking resemblance with the erosion marks downstream of the wellhead assembly wingports) and () localized corrosion attack in heat-affected zones (HAZ). HAZ like welded connections underwent changes in properties making them less resistant to corrosion. Rough edges and protrusions inside the tapping points may also be initial points of erosion-corrosion attack. The entrained water phase of 311D consists of brine mists and steam condensates. Two-phase fluids stagnate in dead legs (between flange connections and in external attachments like sampling points and vents) and condense in these heat sinks through convective heat transfer with the surroundings. Condensates conductively cooled below line temperatures (188 C) dissolve more corrosive gaseous species (e.g., CO, H S, volatile Cl if present) to form acidic solutions. The ph of the nearly-pure condensates declines readily in the absence of the buffering effect of minerals normally present in brine. Water chemistry at line condition was recalculated using the conductive heating feature of WATCH.1 from sampling condition (5 C). At 188 C, the Pourbaix diagram indicates a stability area shifted towards the region of uniform corrosion when the solution ph declines to ~.3 (Fig. 6).. Two-Phase Header Thinning The 30-inch diameter two-phase header experienced rapid thinning in a limited section within and downstream of the 311D stub-in point. The severity of the thinning led to the replacement of a 6 m section after ~10 years of utilization. w scratches/grooving marks in the replaced pipe suggest that the damages are not caused by solids erosion. The internal surface of the replaced pipe showed irregularlyshaped craters either on the metal surface or on the adhering corrosion products (Fig. 7). MASTER VALVE EXPANSION SPOOL WINGPORT PRODUCTION CASING Figure : Mechanisms leading to well 311D wellhead assembly damage (not drawn to scale). Figure 5: Damages in the tapping points of the -inch diameter bypass line and 1-in diameter vent viewed from inside the branchline. 3

Angcoy et al. Eh (Volts) 0.6 - S - HO - System at 188.00 C O3 UNIFORM CORROSION REGION 0. 0. PASSIVATION REGION 0.0-0. S -0. 3O (+a) -0.6 S -0.8 HO Limits -1.0 0 1 3 5 6 7 C:\HSC5\EpH\balikx188C.iep ELEMENTS S 8 ph Molality 3.550E-05.30E-03 Pressure 1.180E+01 1.180E+01 Figure 6: Pourbaix diagram of well 311D condensate chemistry at line temperature (188 C). This phenomenon is primarily attributed to the effects when the steam-dominated discharge of well 311D mixes with the watery discharge of well 309D. Because of the difference in pipe diameter, a Bernoulli effect could occur when a higher velocity well 311D discharge enters the two-phase header. Bubbles or cavities from the water flow of well 309D can be intermittently drawn towards the lower pressure area and rapidly collapse in the upper walls producing a shock wave that dents the metal surface (Fig. 8). After mixing, some steam of well 311D condense and absorb more gas species increasing the corrosion potential of the mixed water phase. Some of the pits in the pipewall initiated by the cavitation effect develop into a local galvanic cell that promotes pitting corrosion and develops into pinhole leaks. Figure 7: Internal surface of the replaced 30-inch twophase header. 3. CONCLUSIONS AND MITIGATING MEASURES Well 311D was mechanically cleared and relined to reinforce vulnerable sections of the casing and address the worsening thinning in the deeper part of the production casing based on the caliper survey log. The manageable calculated thinning rate of 0.6 mm/yr in the production casing did not justify installation of a downhole mitigating measure to capture suspended solids from the wellbore. Immediate solutions were focused in addressing the wellhead assembly damages which included lining the vulnerable portions of the expansion spool with abrasiveresistant layer, reinforcement of the flange connections and revisions of pipe support systems to relieve stresses. Future directions are inclined to duplicate the successful hot brine wellhead washing implemented in wells 301D and 306D (Angcoy et al., 005) since washing through the wingports will mitigate erosion-corrosion from the wellhead to downstream sections by (a) scrubbing suspended solids in steam and (b) buffering the acidity of the water phase due to absorption of more corrosive gas species. All appurtenances attached to the sweepbend and branchline were reviewed for relocation in areas of least turbulence and for insulation to minimize condensation. A limited section of the two-phase header was also reinforced with a higher pipe thickness to anticipate rapid thinning within the mixing points. SF = 10-18 kg/s, WF = <1 kg/s H =,780 J/g 311D 18-inch diameter Damaged section (~6 m) 309D SF = 0 kg/s, WF = 33 kg/s H = 1,600 J/g 30-inch diameter Figure 8: Mixing of wells 311D and 309D discharges. ACKNOWLEDGMENTS Sincere thanks to the members of the LGPF Task Force Wellbore Erosion-Corrosion, LGPF Resource Management Department for the spirited exchange of ideas and concerted efforts in tackling the challenges and the EDC management for supporting the publishing of pertinent data. REFERENCES Angcoy, E.C., Jr, Alcober, E.H., Ramos S.G. and Rossell, J.B.: Erosion in South Sambaloran FCRS Facilities, Tongonan, Leyte, Proceedings, 6th Annual PNOCEDC Geothermal Conference, (005), 109-115.

Buñing, B., Sarmento, Z., Aleman, E. and Saw, V.: Casing Inspection Caliper surveys: results and implications to operations in Leyte Geothermal Production Field, Proceedings, World Geothermal Congress 005, Antalya, Turkey, (005), CD, 5 pp. LGPF Task Force Wellbore Erosion-Corrosion: Well 311D Erosion-Corrosion Assessment Report, Internal Report, (007), PNOC-EDC. Roine, A.: HSC Chemistry 5.0, (00). Salama, M.: An alternative to API 1E erosional velocity limits for sand laden fluids, Journal of Energy Resources Technology, (000). Salonga, N., Herras, E., Siega, F., Seastres Jr., J., and Dacillo, D.: Geochemical signatures of the field-wide expansion process of the upper steam zone in Tongonan geothermal field, Philippines, Geothermics, 33, (00), 109-11. Villa Jr., R., Isip, H., Peñaranda, J.R., Salonga, N., Rubin, D., Bontia, U.R., and Saw, V.: Methods of removing solids from the discharge of steam dominated wells in Leyte Geothermal Production Field, Philippines, Internal Report, (005), PNOC-EDC. 5