Case Study Nanoparticle Containment

Similar documents
MEASURING NANOPARTICLE EXPOSURE

Workplace safety of nanostructured nanomaterials

Nanoparticle Exposure in the Workplace

Engineered Nanomaterials and Occupational Health

(manufactured) nano aerosols

Protocol. Indranil Chowdhury Chemical and Environmental Engineering, University of California, Riverside

International publications on measuring nanoparticles with the portable testo DiSCmini particle counter.

Exposure to Nanomaterials:

Nanotechnology and Exposure: The Pathway to a Safe and Healthy Environment. Professor Candace Tsai Colorado State University

Unilever s approach to assuring the safety of novel nanomaterials - supporting the risk assessment science

Nano-Materials & Health

Dominick Fazarro, Ph.D., CSTM University of Texas at Tyler Webinar August 20, 2014

NON-FUNCTIONALISED AND FUNCTIONALISED SILICA NANOSPHERES 1. Case metadata

There are a number of instruments that can be used to measure LDSA; for example, TSI has two

Introduction and Initial Field Data of a Novel, Portable Nanoparticle Sizing Instrument

Real Time Dust Monitoring Strategies and Tools

A new versatile condensation particle counter for research and environmental monitoring

Meeting about nano. Nina Dawidowicz, Senior Research Officer, Formas, together with researcher Lidia Morawska from Australia.

NANOTECHNOLOGY: AN INDUSTRIAL HYGIENE PERSPECTIVE. Loren Anderson, CIH, ROH

Comprehensive Measurement of Atmospheric Aerosols with a Wide Range Aerosol Spectrometer

TSI KNOWS NANOPARTICLE MEASUREMENT

Nano in de praktijk. TOS Health, Environment and Safety. Jack Smeets. Experience you can trust.

New Instruments from GRIMM

Today we re going to talk about understanding chemical labels. Each one of us works with chemicals, whether at work or at home. You need to know how

DiSCmini. Handheld diffusion size classifier for nanoparticle measurement.

testo DiSCmini Diffusion Size Classifier miniature Product information 2017 Silvia López Vidal Directora de I+D de IONER

Protecting Workers A NIOSH Nanomaterials Update

Testing the Efficiency of the Simultaneous Air Cleaning of Dust and Gases by Fibrous Filtering and Sorptive Structures

Nanomaterials: Why risk assessment is so difficult

11/7/2011. How are we exposed? How serious the exposure can be? Working with nanomaterials!? Dr. Candace SJ Tsai. November 9, 2011 TURI CE Workshop

Partector Application: Fast wide range particle sizing

Occupational Health and Safety Decisions in the face of Nanomaterials Uncertainties. Outline

Meetprincipes voor meting van nanodeeltjes in de lucht

An assessment of time changes of the health risk of PM10 based on GRIMM analyzer data and respiratory deposition model

Peter Kearns, PhD OECD, ENV/EHS BIPM, April 2015

The new 11-R (one part of the Mini WRAS) and GRIMM MINI-WRAS Andreas Jaksch. Symposium Stockholm Mai

Research Article Workplace Exposure to Titanium Dioxide Nanopowder Released from a Bag Filter System

Safe use of nanomaterials Good examples from Finland

Responsibilities: Effective Date: November Revision Date: February 8, VP, Facilities and Construction Management. Issuing Authority:

A Study to Measure the Chemical Characteristics of Particle Emissions from Biomass Burning Stoves

Towards a responsible development of Nanomaterials

Nanoparticles: het nieuwe fijnstof?

How to address health hazards of nanomaterials?

DIRECT READING INSTRUMENTS FOR AEROSOLS

Measuring sub-50nm particle retention of UPW filters

Nanomaterials in the Laboratory

Organisation de Coopération et de Développement Économiques Organisation for Economic Co-operation and Development

Fate, Transport, and Toxicity of Nanoparticles in the Environment

NANOSCAN SMPS SPECTROMETER COMPARED TO THE TSI SMPS SPECTROMETER

Measurement strategies for nanomaterials applicability to the environment

HAZARD COMMUNICATION SAFETY PROGRAM

Characterization Methods of Manufactured Nanomaterials for EHS Studies

저작권법에따른이용자의권리는위의내용에의하여영향을받지않습니다.

ppm = parts per million

TSI Knows Nanoparticle Measurement

Lung-deposited surface area

CALIBRATION CERTIFICATE FAILURE EXPLANATION FOR AEROTRAK PARTICLE COUNTERS

Monitoring of Airborne Nanoparticles in Research Laboratories at the Center for High-Rate Nanomanufacturing (CHN)

This Something We Should Worry About?

Introduction to Societal Impacts of Nanotubes

Appendix R14-4 Recommendations for nanomaterials applicable to Chapter R.14 Occupational exposure estimation

Industrial Hygiene Report

Nanoparticle Safety Program

Nano particles: Surface area as the metric in risk assessment

Your partner in Science!

SIZE-SELECTED AEROSOL FILTER ANALYSIS USING ELECTROSTATIC CLASSIFICATION AND LIBS

Characterisation of nanomaterials for REACH dossiers - best practice 30 October 2012

Measuring with a Microscope

Supplementary Material

Basic Hazard Communication

Production of nanoscaled zinc oxide particles in a laboratory Field measurement report No 3

Report of. Nanomaterials Health and Safety Updates. Prepared for The Refractories Institute

ENHANCED FINE PARTICLE COLLECTION USING THE INDIGO AGGLOMERATOR

Marquette University Effective: 5/21/02 Hazard Communication Program Updated: 03/11/09 Revision No.: 1 Page: 1

Workplace exposure to nanoparticles Literature survey


Facilities Management

Aerosol Generation and Characterisation for Nanotoxicology

Monitoring method for carbon nanotubes (CNT): Personal sampler and corresponding reading device

Molecular Adsorption at PM Surfaces

Radiation Safety. PIXE PAN 2008 Ed Stech University of Notre Dame

Multi-Instrument Manager Tool for Data Acquisition and Merging of Optical and Electrical Mobility Size Distributions

CHEMISTRY 170. Radioisotopes

TECHNICAL REPORT EUROPEAN COMMISSION

Information gathering

Steven E. Mischler. BA, Kenyon College, MS, University of Michigan, School of Public Health, Submitted to the Graduate Faculty of

Safe Use of Nanoparticles Standard Operating Procedure

RADIATION SAFETY GUIDELINES FOR NON-USERS

Product data sheet Palas U-SMPS 1050 / 1100 / 1200

DOI: /s Link to publication

Toxicological safety assessment of nanocellulose why and how? Juulia Rouhiainen, Pöyry SUNPAP Workshop

High Temperature Condensation Particle Counter (HT- CPC)

Evaluation of the DiSCmini personal aerosol monitor for submicrometer sodium chloride and metal aerosols

Overview of LNE s activities led in aerosol metrology

Introduction to Dynamic Light Scattering for Particle Size Determination

Nanotechnology & Respiratory Protection Issues

Characterization, Exposure Measurement and Control for Nanoscale Particles in Workplaces and on the Road

Hazard Communication Policy

GUIDELINES OF PROCUREMENT - CHEMICALS FOR RESEARCH CHEMICAL MANAGEMENT CENTRE

Calibration checks of particle counter using primary and other techniques at the laboratory level

Transcription:

Case Study Nanoparticle Containment Dennis Ford Staff Engineer / Laser Safety Officer Abbott Vascular 1

Agenda Background Toxicology Measurement Systems Data Analysis Mitigation End Results 2

Agenda Background Toxicology Measurement Systems Data Analysis Mitigation End Results 5/07 - Became LSO 7/07 - Attended LSO Workshop 3

Agenda Background Toxicology Measurement Systems Data Analysis Mitigation End Results 5/07 - Became LSO 7/07 - Attended LSO Workshop 4

Agenda Background Toxicology Measurement Systems Data Analysis Mitigation End Results 5/07 - Became LSO 7/07 - Attended LSO Workshop Why worry about nanoparticles? 5

Size, Shape, and Surface Area Matters 6

Size, Shape, and Surface Area Matters 7

Size, Shape, and Surface Area Matters 8

Size, Shape, and Surface Area Matters Oberdörster, Günter; Oberdörster, Eva; Oberdörster, Jan. Concepts of Nanoparticle Dose Metric and Response Metric 9

Size, Shape, and Surface Area Matters Oberdörster, Günter; Oberdörster, Eva; Oberdörster, Jan. Concepts of Nanoparticle Dose Metric and Response Metric Bullis, Kevin. Shape Matters for Nanoparticle: Particles the size and shape of bacteria could more effectively deliver medicine to cells. 10

Toxicology National Institute for Occupational Safety and Health 1.5 mg/m 3 for fine TiO 2 (diameter greater than 100 nm) 0.1 mg/m 3 for ultrafine TiO 2 particles (diameter less than 100 nm) 11

Toxicology National Institute for Occupational Safety and Health 1.5 mg/m 3 for fine TiO 2 (diameter greater than 100 nm) 0.1 mg/m 3 for ultrafine TiO 2 particles (diameter less than 100 nm) British Standards Institute benchmark level of 0.066 WEL (workplace exposure limit) urban UK pollution is 20,000 to 50,000 particles/ml lower end of this range 20,000 particles/ml discriminated from the ambient environmental particle concentration is an appropriate benchmark 12

Toxicology National Institute for Occupational Safety and Health 1.5 mg/m 3 for fine TiO 2 (diameter greater than 100 nm) 0.1 mg/m 3 for ultrafine TiO 2 particles (diameter less than 100 nm) British Standards Institute benchmark level of 0.066 WEL (workplace exposure limit) urban UK pollution is 20,000 to 50,000 particles/ml lower end of this range 20,000 particles/ml discriminated from the ambient environmental particle concentration is an appropriate benchmark Institute of Occupational Medicine particle surface area is the most appropriate metric for assessment of inhalation exposure to nanoparticles 13

Instrument Comparison PMS Nano-ID TSI SMPS 3936L75 TSI AeroTrak 9000 Mass Number Surface area Mass & SA by calc. 1 nm 35 µm 10 nm 1 µm 100 400 nm Samples saved for later analysis Real-time Size distribution Real-time Abbott Vascular chose these machines based on availability for evaluation. The machines were loaned to Abbott Vascular for the purposes of completing these tests. Abbott Vascular would like to thank both Particle Measuring Systems and TSI for their generous support. Abbott Vascular makes no recommendation regarding the applicability of these machines to any measurement. 14

Instrument Comparison PMS Nano-ID TSI SMPS 3936L75 TSI AeroTrak 9000 Mass Number Surface area Mass & SA by calc. 1 nm 35 µm 10 nm 1 µm 100 400 nm Samples saved for later analysis Real-time Size distribution Real-time Abbott Vascular chose these machines based on availability for evaluation. The machines were loaned to Abbott Vascular for the purposes of completing these tests. Abbott Vascular would like to thank both Particle Measuring Systems and TSI for their generous support. Abbott Vascular makes no recommendation regarding the applicability of these machines to any measurement. 15

Particle Measuring Systems Nano-ID 1 nm - 35 µm Collects samples onto 7 glass slides and 5 nylon filters for later analysis 16

Particle Measuring Systems Nano-ID Analysis: Optical Microscope 7.86 µm 17

Particle Measuring Systems Nano-ID Analysis: Scanning Electron Microscope 18

Particle Measuring Systems Nano-ID Analysis: Energy Dispersive Spectroscopy Counts 50 40 Ta 30 20 O 7.86 µm 10 0 C W Na Ta Nb Pd Ca Pd Ca Au Ta Ta Ta 0 2 4 6 8 10 Energy(keV) 19

Instrument Comparison PMS Nano-ID TSI SMPS 3936L75 TSI AeroTrak 9000 Mass Number Surface area Mass & SA by calc. 1 nm 35 µm 10 nm 1 µm 100 400 nm Samples saved for later analysis Real-time Size distribution Real-time Abbott Vascular chose these machines based on availability for evaluation. The machines were loaned to Abbott Vascular for the purposes of completing these tests. Abbott Vascular would like to thank both Particle Measuring Systems and TSI for their generous support. Abbott Vascular makes no recommendation regarding the applicability of these machines to any measurement. 20

TSI Scanning Mobility Particle Sizer 3936L75 Provides complete size distributions in 16 seconds Broad size range from 2.5 nm to 1,000 nm 21

TSI Scanning Mobility Particle Sizer 3936L75 Particle size distribution at engineering cubicle Particle Count by Size 2,500 Count (Particles/cm3) 2,000 1,500 1,000 500 Cube 0 1 10 100 1000 Diameter (nm) 22

TSI Scanning Mobility Particle Sizer 3936L75 Particle size distribution at engineering cubicle and outside lab Particle Count by Size 25,000 Count (Particles/cm3) 20,000 15,000 10,000 5,000 Cube Outside Lab 0 1 10 100 1000 Diameter (nm) 23

TSI Scanning Mobility Particle Sizer 3936L75 Particle size distribution at engineering cubicle, outside lab and near operator Particle Count by Size 250,000 Count (Particles/cm3) 200,000 150,000 100,000 50,000 Cube Outside Lab Operator 0 1 10 100 1000 Diameter (nm) 24

TSI Scanning Mobility Particle Sizer 3936L75 Particle size distribution at engineering cubicle, outside lab, near operator and at process head while cutting metal. Particle Count by Size 2,500,000 Count (Particles/cm3) 2,000,000 1,500,000 1,000,000 500,000 Cube Outside Lab Operator Laser Metal 0 1 10 100 1000 Diameter (nm) 25

TSI Scanning Mobility Particle Sizer 3936L75 Particle size distribution at engineering cubicle, outside lab, near operator and at process head while cutting plastic. Particle Count by Size 2,500,000 Count (Particles/cm3) 2,000,000 1,500,000 1,000,000 500,000 Cube Outside Lab Operator Laser Plastic 0 1 10 100 1000 Diameter (nm) 26

TSI Scanning Mobility Particle Sizer 3936L75 Particle size distribution at engineering cubicle, outside lab, near operator and at process head while cutting plastic. Particle Count by Size 70,000,000 60,000,000 Count (Particles/cm3) 50,000,000 40,000,000 30,000,000 20,000,000 10,000,000 Cube Outside Lab Operator Laser Plastic 0 1 10 100 1000 Diameter (nm) 27

TSI Scanning Mobility Particle Sizer 3936L75 Summary of data taken with TSI 3936 BSI benchmark: 20,000 particles/ml pollution index BSI WEL for metal tested: 0.066 x 5 mg/m 3 = 330 µg/m 3 No available WEL for plastic tested Total Nanoparticle Count (Log) 1.E+08 1.E+06 1.E+04 1.E+02 1.E+00 Cubicle Outside Lab Operator Laser Metal Laser Plastic Nanoparticle Count (#/cm³) Low Urban Pollution High Urban Pollution 28

Instrument Comparison PMS Nano-ID TSI SMPS 3936L75 TSI AeroTrak 9000 Mass Number Surface area Mass & SA by calc. 1 nm 35 µm 10 nm 1 µm 100 400 nm Samples saved for later analysis Real-time Size distribution Real-time Abbott Vascular chose these machines based on availability for evaluation. The machines were loaned to Abbott Vascular for the purposes of completing these tests. Abbott Vascular would like to thank both Particle Measuring Systems and TSI for their generous support. Abbott Vascular makes no recommendation regarding the applicability of these machines to any measurement. 29

TSI AeroTrak 9000 10 nm - 400 nm Provides real-time surface area deposition in alveolar or tracheobronchial regions of respiratory system 30

TSI AeroTrak 9000 Average deposited surface area over five minutes at cube, outside lab, operator and laser for both metal and plastic samples. AeroTrak 9000 Summary (Log) Deposited Surface Area (µm²/cc) 10000.0 1000.0 100.0 10.0 1.0 Average Cubicle Outside Lab Operator Laser Metal Laser Plastic 31

TSI AeroTrak 9000 Deposited surface area over time at cube, outside lab, operator and laser for both metal and plastic samples AeroTrak 9000 (Semilog) 100000 Laser Metal 10000 Fumex Exhaust, Metal Deposited Surface Area (µm²/cc) 1000 100 10 1 0:00:00 0:05:00 0:10:00 0:15:00 0:20:00 Operator Ouside Lab Cubicle 0.1 Laser Plastic 0.01 Time (hh:mm:ss) 32

Toxicology National Institute for Occupational Safety and Health 1.5 mg/m 3 for fine TiO 2 (diameter greater than 100 nm) 0.1 mg/m 3 for ultrafine TiO 2 particles (diameter less than 100 nm) British Standards Institute benchmark level of 0.066 WEL (workplace exposure limit) urban UK pollution is 20,000 to 50,000 particles/ml lower end of this range 20,000 particles/ml discriminated from the ambient environmental particle concentration is an appropriate benchmark Institute of Occupational Medicine particle surface area is the most appropriate metric for assessment of inhalation exposure to nanoparticles 33

Conclusions, are our people safe? Three data sets taken: Particle count - high, but toxicologists tell us particle count is the least indicative of hazard. Mass- Within Work Exposure Limit for metals. Plastic used is considered non toxic and has no WEL Surface Area WEL not yet set for either material tested. ALARA recommended. As Low As Reasonably Achievable Nanoparticle toxicology is just now being investigated. As a result, WEL numbers are not yet available. The ALARA approach is often used in circumstances where the effects of exposure are not fully known. Are our people safe? Data taken after mitigations should answer that question. 34

Recommendations Based on Results Safety mechanism for proper operation of Fumex filter unit Enclosure of laser systems in R&D lab Bag in / bag out filter system Exhaust interlocked 35

TSI AeroTrak 9000 Average deposited surface area over five minutes at cube, outside lab, operator, laser and after filter system for plastic sample both before and after mitigations in place. AeroTrak 9000 Summary (Log) Deposited Surface Area (µm²/cc) 10000.0 1000.0 100.0 10.0 1.0 Before After Cubicle Outside Lab Operator Laser Plastic After Filter 36

Conclusions, are our people safe? Surface area measurements chosen at recommendation of toxicology. Operators exposed to less surface area than found in background. In fact, readings were so low that they were questioned. The measurement at the laser was recreated to verify the measurement system was working correctly. Are our people being exposed to nanoparticles? Data indicates AV operators are exposed to fewer nanoparticles at work than then at home. 37

Acknowledgments Abbott EH&S Temecula ENGINEERING INTERN Jammie Peng Henry Robles, Staff Coordinator EH&S Gary Goltara, Manager Jeffery Shanley, Staff Coordinator EH&S Santa Clara Presley Millare, Staff Coordinator EH&S Mark Wright, DLSO 38