Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer

Similar documents
Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Defining quality standards for the analysis of solid samples

MetWorks Metabolite Identification Software

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Thermo Scientific FLASH HT Plus Elemental Analyzer for IRMS

Thermo Scientific TRITON Thermal Ionization MS. Thermo Scientific NEPTUNE Multicollector ICP-MS. High Resolution Multicollector Mass Spectrometers

Finnigan TRITON Finnigan NEPTUNE. High Resolution Multicollector Mass Spectrometers

of mass spectrometry

for XPS surface analysis

Thermo Scientific DELTA V Advantage DELTA V Plus

Introduction to Fourier Transform Infrared Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy

LTQ XL Linear Ion Trap Mass Spectrometer More Structural Information with MS n

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

ARGUS VI. Static Vacuum Mass Spectrometer. Static Vacuum ARGUS VI. Multicollection Low Volume Precision

LCQ Fleet Ion Trap LC/MS n Exceptional Analytical Value

Fast, Effective XPS Point Analysis of Metal Components

Thermo Scientific TPDRO 1100 Advanced Catalyst Characterization

New Multi-Collector Mass Spectrometry Data for Noble Gases Analysis

Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap

HELIX SFT. Static Vacuum ARGUS VI HELIX SFT. Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

Thermo Scientific LC IsoLink

TPDRO 1100 Advanced Catalyst Characterization. For Temperature Programmed Desorption, Reduction, Oxidation and Chemisorption

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

ICP-MS. High Resolution ICP-MS.

HELIX MC Plus. Static Vacuum. ARGUS VI Thermo Scientific HELIX MC Plus Static Vacuum Mass Spectrometer Static Vacuum Mass Spectrometer

DFS Magnetic Sector GC/MS

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Finnigan TSQ Quantum Discovery MAX

IRMS. perspective. Isotope Ratio Mass Spectrometry.

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

High-Pressure Electrolytic Carbonate Eluent Generation Devices and Their Applications in Ion Chromatography Systems

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

HIGH PERFORMANCE MASS SPECTROMETERS FOR EARTH AND PLANETARY SCIENCE

IN QUALITATIVE ANALYSIS,

The Raman Spectroscopy of Graphene and the Determination of Layer Thickness

Thermo Finnigan LTQ. Specifications

Finnigan TRACE DSQ GC/MS

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

XPS Surface Characterization of Disposable Laboratory Gloves and the Transfer of Glove Components to Other Surfaces

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Thermo Scientific GasBench II

Utility of H-SRM to Reduce Matrix Interference in Food Residue Analysis of Pesticides by LC-MS/MS Using the TSQ Quantum Discovery

ARL OPTIM X X-Ray Fluorescence Spectrometer. Optimized Performance for Your Application

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

PERSPECTIVE STABLE ISOTOPE RATIO MS

Thermo Scientific ITQ Series Quadrupole Ion Trap GC/MS n

Thermo Scientific irm-gc/ms Technology

Fitting of ETD Rate Constants for Doubly and Triply Charged Ions in a Linear Ion Trap

HR/AM Targeted Peptide Quantification on a Q Exactive MS: A Unique Combination of High Selectivity, High Sensitivity, and High Throughput

Finnigan LCQ Advantage MAX

Complementary Use of Raman and FT-IR Imaging for the Analysis of Multi-Layer Polymer Composites

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Thermo Scientific 253 Plus 10 kv Isotope Ratio MS. Utilize the Gold Standard. in isotope ratio MS. Robustness Sensitivity Precision

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Prima PRO Process Mass Spectrometer

Complete Materials Deformulation Using TGA-IR

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Elemental analysis by X-ray f luorescence. High performance EDXRF elemental analyzer

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

S8 TIGER Series 2 for ASTM D 6443

Environmental Series - Trace contaminant analysis in brine using a Thermo Scientific icap 6000 Series Duo ICP

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

PERSPECTIVE STABLE ISOTOPE RATIO MS

Semiconductor Capabilities. Lab-to-Fab Solutions

Rapid Quan/Qual Metabolic Stability Analysis with Online Oxidative Metabolism Synthesis

Key Words Nanoparticles, spicp-ms, ICP-MS, Qtegra ISDS Software, AF4-ICP-MS

A Total Solution for Explosives Analysis by Reversed-Phase HPLC with a Parallel HPLC System

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Active Flow Technology Understanding How the Flow Rate Profile Affects the Chromatographic Efficiency

Automated, intelligent sample preparation: Integration of the ESI prepfast Auto-dilution System with the Thermo Scientific icap 7400 ICP-OES

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Thermo Scientific Neptune XT MC-ICP-MS

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

SIFT-MS. technology overview

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Extrel is widely respected for the quality of mass spectrometer systems that are

Method Development for a Simple and Reliable Determination of PCBs in Mineral Insulating Oil by SPME-GC-ECD

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Thermo VG PQ EXCELL INDUCTIVELY COUPLED PLASMA MASS SPECTROMETER

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

Rapid, simple, interference-free analysis of environmental samples using the XSERIES 2 ICP-MS with 3 rd generation CCT ED

Elemental analysis by X-ray f luorescence. Sequential benchtop WDXRF spectrometer

Thermo Scientific. Anion-Exchange Column. Determination of Inorganic Anions in Diverse Sample Matrices. Superior Chromatographic Performance

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

New On-Line High-Pressure Electrolytic Eluent Generators for Ion Chromatography

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Transcription:

m a s s s p e c t r o m e t r y Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer Reset Your Expectations Part of Thermo Fisher Scientific

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer The ELEMENT GD, a combination of a glow discharge ion source with a high resolution mass spectrometer, is the ultimate tool for the direct analysis of conductive materials. Almost all elements present in a solid sample, including carbon, can be detected and routinely quantified. Many elements can be analyzed down to the ppt (parts per trillion) range. The ELEMENT GD is tailored to serve high purity metal manufacturers as well as their customers in industries such as: Microelectronics - Copper, Aluminum, Sputter Targets Aerospace - Aluminum, Stainless Steel, Alloys Medical/Pharmaceutical/Food - Stainless Steel, Alloys 2 Nuclear - Uranium, Nuclear Fuel

Reset your expectations for the elemental analysis of solid samples 3

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer Technology The Thermo Scientific ELEMENT GD combines components with superior attributes in an instrument incomparable in speed, sensitivity and accuracy. Overview Fast flow, high power glow discharge cell -Short analysis time due to high sputter rates -Superior sensitivity State of the art double focusing mass spectrometer -Incomparable signal to noise ratios resulting from high ion transmission combined with a low background leading to sub-ppb detection limits -Maximum level of selectivity and accuracy due to high mass resolution: a prerequisite for indisputable analytical results More than 12 orders of magnitude automatic detection system -Determination of ultra-traces and matrix elements within a single scan, due to a fully automatic detector with > 12 orders of linear dynamic range -Direct determination of the matrix elements for IBR (Ion Beam Ratio) quantification State-of-the-art software suite for productivity and ease-of-use -Full computer control of all parameters -Fully automated tuning, analysis and data evaluation -LIMS connectivity with automatic data transfer -Remote control and diagnostic -Microsoft Windows XP Operating System Quantitative multi-element analysis across the periodic table Less than 10 minutes sample turn-around Matrix to ultra-trace detection capabilities in a single scan Depth profiling Minimum matrix effects for straightforward quantification 4

The ELEMENT GD ion source and sample holder is designed for easy sample change-over, offering routine operation and high throughput. Easy Sample Handling The ingenious and yet simple design of the Glow Discharge Source reduces sample to sample switching to a fraction of the time it used to be. The sample itself is placed in a vacuum chamber, completely eliminating any risk of leak between the sample and the GD cell (Figure 1). The sample holder can quickly and easily be removed from the ion source, simply unloaded and re-loaded, and repositioned for the next measurement (Figure 2). Opening and closing of the ion source manifold is fully automatic. Figure 1: Evacuation of the vacuum manifold requires a few seconds Figure 2: Placement of the sample holder in the GD source 5

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer The Ion Source Thermo Scientific ELEMENT GD - The Power to do More: No more than 5 minutes are required to analyze 50 elements in the low ppb range. The Ion Source A glow discharge occurs when a potential difference is applied between two electrodes in a cell filled with gas (in most cases Ar) at reduced pressure. In a configuration for elemental analysis the sample acts as the cathode, and its surface is sputtered by impacting gas ions. The sputtered neutral atoms are ionized downstream in the plasma. Because the processes of sputtering and ionization are separated, minimal non-spectral matrix effects are observed. Therefore, perfect conditions can be achieved for the establishment of Relative Sensitivity Factors (RSF), enabling quantitative analysis or using simple Ion Beam Ratios (IBR) for semi-quantitative analysis. ELEMENT GD DISCHARGE PARAMETERS Discharge gas flow (typically): 300-500 ml/min Voltage: 500-1400 V Current: 5-75 ma Intelligent matching of parameters ensures controlled sample sputtering Characteristics of the ELEMENT GD Glow Discharge Source 2-3 minutes data acquisition time at ppb concentrations High sensitivity for short analysis times Fast and simple sample to sample switching No cryo-cooling Flexible cell for flat samples or pressed powders Disposable flow tubes to eliminate the risk of cross contamination Easy and fast changeable anode Variable sputter rates for bulk analysis or depth profiling Large sputtered sample area for representative surface sampling Figure 3: The Glow Discharge process The new ELEMENT GD ion source takes full advantage of the intrinsic features of a glow discharge ion source, delivering RSF stability and high sputter rates. At the same time it offers a simple and fast sample change-over, providing routine operation and high throughput without any compromise in performance. High throughput is additionally supported by electronic (Peltier) sample cooling (or heating), eliminating the need for cooling with cryogenic gases. There is a much reduced requirement for perfectly flat samples because the sample is not used as a vacuum seal. Proper vacuum condition is guaranteed by a separate vacuum manifold employing an optimized sealing mechanism. This, due to its negligible leak rate, enables the measurement of oxygen, nitrogen and carbon at low concentrations. Figure 4: Schematic of the Glow Discharge Ion Source 6

The Mass Spectrometer High mass resolution is a prerequisite for accurate interference-free analysis. The Mass Spectrometer The ELEMENT GD glow discharge mass spectrometer uses advanced high resolution magnetic sector field technology. The primary limitation of GD-MS is the presence of spectral interferences arising from the combination of matrix elements and the discharge gas with other species in the plasma. Consequently high mass resolution is a prerequisite for the accurate determination of analytes, separated from the majority of possible interferences. The ELEMENT GD provides interference free measurements resulting in simple linear calibration curves for quantification. Three fixed resolution settings, with switching times of < 1 s, ensure optimum conditions to reliably remove spectral interferences. Any combination of resolution setting can be performed within a single analysis. The patented fixed-slit design guarantees maximum stability and reproducibility. The analyzer of the ELEMENT GD is optimized for speed and mass stability. The magnet is designed for the mass range 2-260 u, just right for the demands of elemental analysis. It is relatively small, highly laminated, water cooled and driven by a sophisticated high power regulator: Magnet switching and settling times do no longer slow down the analysis. High precision and accuracy of the mass calibration is vital for short analysis times, allowing precise peak top jumping. Due to an ingenious, fully automatic mass locking process, mass calibration is necessary only once per several months. ELEMENT GD Mass stability: 25 ppm / 8 hour Scan speed: < 150 ms from m/z 7 to 238 to 7 Resolutions: 300, 4000, 10000 with < 1 s switching times Sensitivity (peak height, total ion current): > 1 x 10 10 cps, (1.6 x 10-9 A) for copper in medium resolution (R 4000) Figure 5: The Thermo Scientific ELEMENT Glow Discharge Mass Spectrometer Thermo Scientific ELEMENT GD: Measure 50 elements at low ppb within 5 minutes 7

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer Detection System A sophisticated detection system completes the refined design of the ELEMENT GD. Detection System Since matrix elements (%), traces (ppm), and ultra-traces (ppb to ppt) need to be analyzed simultaneously, the detection system offers: Wide dynamic range: 0.5 cps to > 10 12 cps High speed: down to 1 ms integration time Automatic, fast switching between different detection modes Automatic cross calibration between different detection modes In the ELEMENT GD this is achieved through the use of a unique and novel combination of a dual mode (dark noise < 0.5 cps) secondary electron multiplier (SEM) and a Faraday collector (maximum current > 10 12 cps). The Faraday detector does not lengthen analysis time: due to its fast detection electronics it does not suffer decay times and allows integration times down to 1 ms. > % Figure 7: Dynamic range of the ELEMENT GD Detection System Exit Slit ESA Faraday SEM Figure 6: Detection System of the ELEMENT GD 8

Product Specification The mass spectrometer of the ELEMENT GD is proven in more than 500 Thermo Scientific ELEMENT High Resolution ICP-MS installations worldwide. Specifications and Installation Requirements ELEMENT GD Sensitivity (peak height, total ion current) Dark Noise Dynamic Range Minimum integration times > 1 x 10 10 cps, (1.6 x 10-9 A) for copper in medium resolution (R 4000) 0.5 cps > 10 12 linear with automatic cross calibration Counting mode: 0.1 ms, analog mode: 1 ms, Faraday mode: 1 ms Mass Resolution 3 fixed resolutions: 300; 4.000; 10.000 Resolution Switching Times Mass Stability < 1 s 25 ppm / 8 hour Scan Speed (magnetic) < 150 ms from m/z 7 to 238 to 7 Scan Speed (electric) 1 ms/jump, independent of mass range Power 3-phase, 230/400 V ± 10%, 50/60 Hz fused 32 A per phase Power Consumption Temperature Humidity max. 8 kva 18-24 C (64-75 F) 50-60 %, non-condensing, non-corrosive Cooling Water ~200 L/h Temperature 10-20 C 4-6 bar (43-65 psi) Argon 1 L/min Argon 5.0 (or higher); 5 L/min Argon 4.6 Regulated pressure 8-10 bar (116-145 psi) Pump Exhaust 1 x 25 mm, 1 L/min Electronic Exhaust 1 x 150 mm, 400 m 3 /h ELEMENT GD, Footprint and Dimensions in cm 9

Thermo Scientific ELEMENT GD Glow Discharge Mass Spectrometer The Software Suite The Thermo Scientific ELEMENT GD software is a state-of-the-art, simple to use software suite. Optimized Laboratory Software The software package is optimized for the needs of a routine laboratory, providing a simple to use interface to fully utilize the power of the ELEMENT GD. Using Microsoft Windows XP Professional as the operating system and standardized programming assures a flat learning curve, easy network connection for data transfer as well as remote control and diagnostic. The software is based upon that used in the ELEMENT High Resolution ICP-MS, proven in more than 500 installations worldwide. Intuitive and easy creation of methods and analysis sequences Real time display of spectra, time resolved data and results Automatic data export to LIMS systems Effortless autotuning of instrument parameters Microsoft Windows XP OS Figure 8: Concise and easy analysis configuration Figure 9: Intuitive method creation 10

The software package is optimized for the needs of the routine analyst, providing ease of use for basic operation as well as flexibility for advanced operation. Software for a high level of transparancy The Element software suite controls and monitors all instrument functions for GD-MS analysis and data evaluation. Real time display of mass spectra, time resolved data, calibration curves and comprehensive reports guarantee a high level of transparency and therefore easily traceable results. Full and flexible support for LIMS connectivity ensures convenient, automatic and safe data management. Figure 11: Glow Discharge Ion Source software control Figure 10: Real time display of calibration curves, spectra and results The Element software package offers full quantitative analysis using Relative Sensitivity Factors (RSF) obtained from standard materials or semi-quantitative analysis using Ion Beam Ratios (IBR). Since the ELEMENT GD detection system is capable of measuring traces and the matrix within one analysis, the ratio between the analyte and the matrix (100%) is used for quantification. Intelligent and straightforward quantification strategies User definable report configuration Traceable data management Remote control & diagnostic Proven in > 400 ELEMENT High Resolution ICP-MS installations worldwide 11

Laboratory Solutions Backed by Worldwide Service and Support Tap our expertise throughout the life of your instrument. Thermo Scientific Services extends its support throughout our worldwide network of highly trained and certified engineers who are experts in laboratory technologies and applications. Put our team of experts to work for you in a range of disciplines from system installation, training and technical support, to complete asset management and regulatory compliance consulting. Improve your productivity and lower the cost of instrument ownership through our product support services. Maximize uptime while eliminating the uncontrollable cost of unplanned maintenance and repairs. When it s time to enhance your system, we also offer certified parts and a range of accessories and consumables suited to your application. To learn more about our products and comprehensive service offerings, visit us at www.thermo.com. In addition to these offices, Thermo Fisher Scientific maintains a network of representative organizations throughout the world. Africa-Other +27 11 570 1840 analyze.sa@thermo.com Australia +61 2 8844 9500 analyze.au@thermo.com Austria +43 1 333 50 34 0 analyze.at@thermo.com Belgium +32 2 482 30 30 analyze.be@thermo.com Canada +1 800 530 8447 analyze.ca@thermo.com China +86 10 8419 3588 analyze.cn@thermo.com Denmark +45 70 23 62 60 analyze.dk@thermo.com Europe-Other +43 1 333 50 34 0 analyze.emea@thermo.com Finland / Norway/Sweden +46 8 556 468 00 analyze.se@thermo.com France +33 1 60 92 48 00 analyze.fr@thermo.com Germany +49 6103 408 1014 analyze.de@thermo.com India +91 22 6742 9434 analyze.in@thermo.com Italy +39 02 950 591 analyze.it@thermo.com Japan +81 45 453 9100 analyze.jp@thermo.com Latin America +1 608 276 5659 analyze.la@thermo.com Middle East +43 1 333 50 34 0 analyze.emea@thermo.com Netherlands +31 76 579 55 55 analyze.nl@thermo.com South Africa +27 11 570 1840 analyze.sa@thermo.com Spain +34 914 845 965 analyze.es@thermo.com Switzerland +41 61 716 77 00 analyze.ch@thermo.com UK +44 1442 233555 analyze.uk@thermo.com USA +1 800 532 4752 analyze.us@thermo.com www.thermo.com Thermo Fisher Scientific (Bremen) GmbH Management System Registered to ISO 9001:2008 2005, 2008, 2009 Thermo Fisher Scientific Inc. Microsoft and Windows are registered trademarks of Microsoft Corporation. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. BR30066_E12/09C