Mini Environmental Quality Meter

Similar documents
IR/Thermistor Pen. Instruction Manual

VIBRATION METER. Instruction Manual.

ea980r Digital Anemometer User Manual

SUGAR/BRIX REFRACTOMETER INSTRUCTION MANUAL

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

Acceleration/Velocity/Displacement VIBRATION METER

Dual laser + type K thermometer INFRARED THERMOMETER

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

Heat stress index. Dewpoint. pressure. altitude

QUICK SET UP MANUAL WEATHER CENTER

Instruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector

Hadrons Desktop U.S. Atomic Clock & Weather Station

GPS Scout Backtrack Altimeter Model: GP123 USER MANUAL

BIOS. Weather. 266BC Wireless Wind Chill and Humidex Thermometer. Thermomètre sans fil pour indices de refroidissement éolien et humidex

INFRARED THERMOMETER Model : TM-959

2 ACCESSING VARIOUS MODES

WS-9018U Wireless Weather Station. Instruction Manual

Anemometer Thermometer Hygrometer

Wireless Color Forecast Station Model: K86319

Wireless Weather Station Instruction Manual

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

U.S. Atomic Clock & Weather Station. Instruction Manual

TG646 WEATHER STATION

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

06MAR THU 12: User Manual

PROFESSIONAL WEATHER CENTER WS-1611 PROFESSIONAL WEATHER CENTER. This product offers: Table of Contents. Operation Manual FEATURES: Instruction Manual

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

Today s Weather 24 Hour Forecaster

Kestrel 4000 Pocket Weather Tracker

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

The Kestrel Handheld Weather Tracker. 1) If the unit is configured to log data and it is turned off, will it continue to log temperature data?

InfraRed Thermometer with Laser Pointer

Thermal anemometer. We measure it. testo 405. Flow velocity measuring instrument with temperature measurement

473-SHX Dew Point Mirror

1450 First Ave. Page 1 of 10 Chippewa Falls, WI (800) or (715) Fax: (715)

All-In-One Wireless Professional Weather Station (DCF) (975246)

One-Year Limited Warranty

WM9280. Pro Family weather station with T/H sensor, pluviometer, anemometer, PC connection and Meteotime weather forecasts until 3 days

473 Dew Point Hygrometer

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

473 Dew Point Hygrometer

Quick Reference Guide

Vantage PRO2 Quick. Reference Guide

Contents. English 1. French 56. Spanish

WS WEATHER CENTER Instruction Manual

Kestrel 4500 Pocket Weather Tracker

QUICK START GUIDE Kestrel 5000 Environmental Meter Kestrel 5100 Racing Weather Meter Kestrel 5200 Professional Environmental Meter

CABLE FREE WEATHER STATION

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

O P E R A T I N G M A N U A L

INSTRUCTION MANUAL DTH Fax: (503)

IMPORTANT. Questions? Contact Customer Support at (877) or visit Display for 5-in-1 Weather Sensor model 06016RM

Wireless Weather Station. Instruction Manual

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

User Guide. Weather station with wireless outdoor sensor WS-4700

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

566/568. Infrared Thermometers. Getting Started

PTA-427 BAROMETRIC PRESSURE TRANSDUCER OPERATOR S MANUAL

TP2700WC PROFESSIONAL WEATHER STATION

Wireless Full Weather Station Kit Model: WMR80 / WMR80A

Dewpoint Meter Data Sheet / Instructions

Pocket Weather Meter with Backlight

SkyScan EWS-PRO - Manual -

Data Sheet / Instructions. Dewpoint MeterO

INTRODUCTION 4 WATCH FEATURES 5 WATCH MODES 8 BUTTON FUNCTIONS 9 NORMAL OPERATION 9 SETTING OPERATION 11

Operating instructions for electronics

WeatherHub2 Quick Start Guide

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

CABLE FREE WEATHER STATION

Product Description. 1 of 6

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

Speedtech Deerhunter s EDGE TM Model HE-1. Speedtech ECO EDGE TM Model EE-1. User s Manual

INSTRUCTION MANUAL Fax: (503)

868MHz WEATHER STATION Instruction Manual

CA84688 FAQS TABLE OF CONTENTS

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT

Instruction Manual SEFRAM Thermal Camera

WT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual

WIRELESS COLOR WEATHER STATION MODEL B

Weather Station Model WS-9057U

Non-Acoustical Inputs

PROFESSIONAL DIGITAL ALTIMETER. ----ALL in-0ne

Ambient Weather WS-228TBH 9" Brushed Aluminum Traditional Barometer with Temperature and Humidity, Radiant Blue User Manual

HI Propylene Glycol Refractometer INSTRUCTION MANUAL

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

Professional Wind Station

INSTRUCTION MANUAL for No. 45 Altimeter-Compass

Windwatch PRO Pocket Weather Station

Manual Weather Stations & Instruments

Advanced Weather Station with Wireless Sensor Set Model: WMR90A

TOUCH SCREEN WEATHER STATION MODEL WS-3650

Instruction Manual HI Refractometer for Sodium Chloride Measurements

Fischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual

FOR USE IN EU and UK ONLY

Transcription:

Mini Environmental Quality Meter 850027

Mini Environmental Quality Meter 850027 Copyright 2012 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any form or by any means electronic, mechanical, or other means that do not yet exist or may be developed, including photocopying, recording, or any information storage and retrieval system without the express permission from Sper Scientific. INTRODUCTION For environmental testing anywhere. Model 850027 combines 11 environmental test functions into a single compact unit. Features include touch-tone buttons, min/ max and hold functions. Comes ready to use with wrist strap, instructions, battery and soft carrying case. MATERIALS SUPPLIED Meter Wristlet CR 2032 DC 3V Battery Soft Carrying Case Optional Accessory: 850027P - Pt 1000 Temp. Probe 2

TABLE OF CONTENTS 1. INTRODUCTION.................. 2 2. MATERIALS SUPPLIED............... 2 3. FEATURES..................... 4 4. FRONT PANEL DESCRIPTION........... 5 5. OPERATING INSTRUCTIONS........... 6 Power on/off..................... 6 LCD backlight on/off................. 6 Mode selection................... 6 Unit selection.................... 6 Special attention for the Humidity measurement............... 8 Air flow measurement................ 9 Barometric measurement............. 10 Altitude measurement............... 11 Optional Pt 1000 probe.............. 13 Hold Function................... 13 REC (Record) function.............. 13 Auto power off disable............... 14 6. BATTERY REPLACEMENT............ 14 7. SPECIFICATIONS................. 15 8. WARRANTY.................... 20 3

FEATURES 11 professional environmental instruments in 1 Lightweight, ergonomic design Wristlet design provides extra protection to the instrument Low-friction ball bearing mounted impeller design provides high accuracy at high and low air velocity High precision humidity sensor with fast response time Barometric sensor for precise atmosphere and altitude measurement Built-in microprocessor circuit assures excellent performance and accuracy Optional Pt 1000 Temp. probe Concise and compact buttons arrangement for easy operation. Maximum and minimum memory with recall Hold function C/ F selection 4

FRONT PANEL DESCRIPTION 7 4 1 6 2 3 12 11 9 10 8 5 1 HOLD button 2 Button (Power button) 3 REC button 4 LCD display 5 Wristlet 6 Light sensor 7 Anemometer vane 8 Humidity/Temperature sensor 8 Barometer sensor 10 Battery compartment cover 11 Buttons operation label 12 Pt 1000 ohm probe socket 5

OPERATING INSTRUCTIONS Power on/off Button = Power Button 1. Power on: Press once to turn meter on. 2. Power off: Press for > 3 seconds to turn meter off. LCD backlight on/off With the meter on, press once. The LCD backlight will light for 5 seconds, then shut off automatically. Mode selection This meter offers 11 selectable modes: a. Anemometer (Air velocity) /Temp b. Air flow (CMM, CFM) c. Wind Chill d. Humidity/Temp e. Dew point Temp f. Wet bulb Temp g. Heat index h. Light i. Barometric pressure j. Altitude k. Pt 1000 Temp. (optional) 6

With the meter on, press HOLD continuously and the Display will show the following texts in sequence: Display Mode text An = Anemometer (Air velocity) /Temp AirFL = Air flow (CMM, CFM) CHiLL = Wind chill rh = Humidity/Temp dp = Dew point Temp _Et = Wet bulb Temp HEAt = Heat index LIgHt = Light bar = Barometric pressure HigH = Altitude Pt = Pt 1000 Temp. (optional) When the display shows the desired mode, release HOLD and the meter will set this mode as the default. Anemometer (Air Velocity)/Temp Measurement Unit Selection REC button = Enter button 1. With the power on, press REC for >3 seconds, the display will show Unit. Release REC, then press to scroll through the available scales. After the desired scale is selected, press REC to save as the default. 7

2. The next screen displays dcdf with the current temperature scale selection ( C or F). Press to select the desired scale. Press REC to save as the default. Note When CHiLL, rh, dp, _Et and HEAt are the selected mode, you may only change the temperature scale setting. ( C or F) The selection scales for all modes are: Measurement Air Velocity Temp. (Air velocity) Air flow Wind chill Temp. (Humidity) Dew point Wet bulb Temp. Heat index Light Barometric Pressure Altitude Pt 1000 Temp. Scales m/s, Km/h, mph, knot, FPM C/ F CMM, CFM C/ F C/ F C/ F C/ F C/ F Lux, FC hpa, mmhg, inhg m, ft C/ F 8

Air flow measurement 1. With the Power on, select Air flow mode (refer to page 7) 2. Set the measurement area dimension: Press HOLD once, the display will show Hold then press REC continuously until the lower left of the Display shows m-2 or F-2 m-2 = meter square F-2 = ft square The unit of measure is determined by the selected scale CMM or CFM 3. Use HOLD and to adjust the air flow dimension value. When the desired dimension value is set, press REC to save as the default. button = button HOLD button = button REC button = Enter button Note For the most accurate reading for the humidity/ Temp., Dew point Temp., Wet bulb Temp., Heat index measurement, do not touch or block the humidity sensor at any time with your hand. Light measurement For light measurement, hold the meter with the light sensor on top, so it is not blocked by your hand. The display will automatically reverse direction to be easily read. 9

Barometric pressure measurement 1. Actual location air pressure (absolute air pressure value) measurement: with Power on, select Barometric pressure measurement (refer to page 7, display will show bar text), now the meter is ready for actual air pressure measurement (absolute air pressure value). Note... Actual air pressure in the measurement location changes in response to two things: changes in altitude and changes in atmosphere. 2. Sea level barometric pressure value measurement. Press HOLD once, the Display will show the Hold indicator then press REC continuously until the bottom left of the display shows m or ft. m = meter ft = feet Use HOLD and to adjust the location altitude value. When the location altitude value is set, pressing REC will show the sea level barometric pressure value. button = button HOLD button = button REC button = Enter button 10

Note... The sea level barometric pressure value can not be saved as a default when the meter is powered off. When the meter is powered on again and bar is selected the meter will show the actual air pressure in the measurement location (absolute air pressure value). Altitude measurement Note... The higher the location altitude, in comparison to sea level, the lower the barometric pressure. To measure your altitude value precisely: a. Method 1: Set the altitude value if your start location is known. b. Method 2: Reset the sea level barometric pressure value first. Method 1: Power on the meter and under the altitude function, press HOLD once, the display will show the Hold indicator. Press REC once, the bottom of the display will show the m (or Ft) indicator flashing. 11

Using HOLD and adjust the altitude value. When the desired start location altitude value is set, press REC to save the setting value as the default. button = button HOLD button = button REC button = Enter button Note... You can obtain your altitude value from a topographical map or local landmark. Google Earth is an excellent free program that provides the exact altitude for a given address: www.earth.google.com. You can also get the reference altitude value from the reading of a GPS system. Method 2: Power on the meter and under the altitude function, press HOLD once, the display will show the Hold indicator. Press REC continuously until the bottom left of display shows HPA indicator flashing. Release REC. Use HOLD and the to adjust the current sea level barometric pressure value. When the desired value is set, press REC to save as the default. button = button HOLD button = button REC button = Enter button 12

Note... You can obtain your current sea level barometric pressure value by checking an internet weather site for a nearby location or contacting a local airport. Optional Pt 1000 Temp. measurement 1. Insert the plug of the optional Pt 1000 Temp. probe 850027P into the Pt 1000 probe socket (see page 5) 2. Power on the meter, select the function to Pt 1000 Temp. (refer to page 6), now the meter is ready for Pt 1000 Temp. measurement. Hold Function Pressing HOLD will freeze the current reading on the display. The Hold symbol will be displayed at the top of the display window. To release the Hold function, press HOLD again, the Hold indicator will disappear and the current reading will be displayed. REC (Record) function The REC (Record) function will record and display the maximum and minimum readings. 1. Start the Record function by pressing REC once. The REC symbol will appear on the display. 13

2. With the REC symbol on the display: a. Press REC once and the Max symbol will appear on the display along with the current maximum value. b. Press REC again, the MIN symbol will appear on the display along with the current minimum value. c. Clear the recorded MAX or MIN value from the display by pressing HOLD once. The MAX/MIN symbols and their readings, will disappear from the display. The meter will return to the REC function and continue recording. d. To exit REC function press REC button for >2 seconds. Auto power off disable In order to prolong the battery life, this instrument has an Auto Power Off function: the meter will turn off if no buttons are pressed for approximately 10 minutes. To disable the Auto Power Off function, press REC and enter the record function (page 13). The Auto power off function will be disabled until the record function is exited. REPLACE BATTERY 1. When the LCD display shows symbol, it is time to replace the battery. (Measurements may still be made for several hours after the low battery indicator appears.) 2. Open the Battery Compartment and remove the battery. 3. Install the battery (CR2032) and replace the cover. 14

GENERAL SPECIFICATIONS Display Measurement Operating Humidity Operating Temp. Over Input Display - - - - Power Supply Power Consumption Weight Dim (HWD) Standard Accessories Optional Accessories 8 mm LCD display 1. Anemometer (Air velocity)/temp 2. Humidity/Temp 3. Light 4. Barometer 5. CFM, CMM 6. Dew point 7. Wet bulb 8. Wind chill 9. Heat index 10. Altitude 11. Pt 1000 Temp. (opt.) Max. 80% RH 0 ~ 50 C (32 ~ 122 F) CR 2032 DC 3V battery Approx. DC 5 ma 160g (battery included) 4.7" x 1.8" x 1.2" (120 x 45 x 20 mm) Instruction Manual, battery, soft case 850027P Pt 1000Temp. probe 15

ELECTRICAL SPECIFICATIONS (±23 ±5 C) Air Velocity Unit Range Res. Acc. ft/min 80 ~ 3927 1 m/s 0.4 ~ 20.0 0.1 km/h 1.4 ~ 72.0 0.1 mph 0.9 ~ 44.7 0.1 knots 0.8 ~ 38.8 0.1 Temp. C/ F 0 ~ 50 C 0.1 C ± 1.2 C 32 ~ 122 F 0.1 F ± 2.5 F ft/min: feet per minute mph: miles per hour m/s: meters per second knots: nautical miles km/h: kilometers per hour per hour 20 m/s:±3% F.S. >20 m/s:±4% F.S. Air Flow Unit Range Res. CMM 0.024 ~ 36000 0.001/0.01/0.1/1 CFM 0.847 ~1271300 0.001/0.01/0.1/1/10 (x10)/100 (x100) 16

ELECTRICAL SPECIFICATIONS (±23 ±5 C) Wind chill Unit Range Res. Acc. C -0.4 ~ 44.2 0.1 ± 2.0 C F 15.0 ~ 112.0 0.1 ± 3.6 F * Wind chill value is in effect only when the Temp. value <15 C and Air velocity value >1.4 m/s. Humidity/Temperature Unit Range Res. Acc. %RH Temp. 10 to 95 %RH Dew point Temp. 0.1 % RH 0 ~ 50 C 0.1 C ± 1.2 C 32 ~ 122 F 0.1 F ± 2.5 F Unit Range Res. Remark < 70 %RH: ±4 %RH 70 %RH:± (4% rdg +1.2 %RH) C -25.3 ~ 49.0 0.1 * Calculate from the F -13.5 ~ 120.0 0.1 humidity / Temp. value Wet bulb Temp. Unit Range Res. Remark C -5.4 ~ 49.0 0.1 * Calculate from the F 22.2 ~ 120 0.1 humidity / Temp. value 17

ELECTRICAL SPECIFICATIONS (±23 ±5 C) Light *auto range Unit Range Res. Acc. Lux 0 ~ 2,200 Lux 1 Lux 1,800 ~ 20,000 Lux 10 Lux ±5% rdg Foot-candle 0 ~ 204.0 FC 0.1 FC 170 ~ 1,860 FC 1 FC ±8% rdg Barometric Pressure (Barometer) Unit Range Res. Acc. hpa 10.0 ~ 999.9 0.1 hpa ±1.5 hpa 1000 ~ 1100 1 hpa ±2 hpa mmhg 7.5 ~ 825.0 0.1 mmhg ±1.2 mmhg inhg 0.29 ~ 32.48 0.01 inhg ±0.05 inhg Alititude Unit Range Res. Acc. m -2000 ~ 9000m 1 m ± 15 m ft -6000 ~ 30000 ft 1 ft ± 50 ft 18

ELECTRICAL SPECIFICATIONS (±23 ±5 C) Pt 1000 Thermometer (opt. probe) Unit Range Res. Acc. C -10.0 ~ 100.0 0.1 C ± 1.2 C F 14.0 ~ 212.0 0.1 F ± 2.5 F Heat index Unit Range Res. Accuracy C 0 ~ 100 0.1 ± 2.0 C F 32 ~ 212 0.1 ± 3.6 F Effects of the heat index (shade values) C F Notes 27~ 32 32~ 41 41~ 54 80~ 90 90~ 105 105~ 130 Caution: Fatigue is possible with prolonged exposure and activity. Continuing activity could result in heat cramps Extreme caution: Heat cramps, and heat exhaustion are possible. Continuing activity could result in heat stroke Danger: Heat cramps, and heat exhaustion are likely; heat stroke is probable with continued activity 54 + 130 + Extreme danger: Heat stroke is imminent * Exposure to full sunshine can increase heat index values by up to 8 C (14 F) 19

WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the meter to expose its electronics will void the warranty. To obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD. 8281 E. Evans Rd., Suite #103 Scottsdale, AZ 85260 The defective unit must be accompanied by a description of the problem and your return address. Register your product online at www.sperscientific.com, or return your warranty card within 10 days of purchase. Revised 07/21/14 20