Dimensional Issues in Stereolithography

Similar documents
PHOTOPOLYMERIZATION REACTION RATES BY REFLECTANCE REAL TIME INFRARED SPECTROSCOPY: APPLICATION TO STEREOLITHOGRAPHY RESINS

Industrial Processes I Manufacturing Economics

Accuracy of Stereolithography Parts: Mechanism and Modes of Distortion for a "Letter-H" Diagnostic Part

Modeling and Simulation to Materials Development for Rapid Prototyping Process

Automotive: Dashboards, stop lamps, turn signals. 2. Backlighting: LCDs, Key pads advertising.

ABSTRACT 1. INTRODUCTION

1. Automotive : Dashboards, stop lamps, turn signals. 2. Backlighting : LCDs, Key pads advertising.

InfraRed Thermometer with Laser Pointer

NPGN-150R. FEATURES Halogen, antimony, and red phosphorous free Flammability meets UL 94 V-0 NAN YA PLASTICS CORPORATION

High Temperature Strain Measurements Using Fiber Optic Sensors

Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between 30 C and 30 C with a Vitreous Silica Dilatometer 1

Standard Test Methods for Glass-Bonded Mica Used as Electrical Insulation 1

Microsystems Technology Laboratories i-stepperthursday, October 27, 2005 / site map / contact

Novel Liquid Crystal Monomers for Stereolithography: Reaction Rates and Photopolymerization Conversion

1. Automotive : Dashboards, stop lamps, turn signals. 2. Backlighting : LCDs, Key pads advertising. 3. Status indicators : Comsumer & industrial

Calibrating the Thermal Camera

International Journal of Modern Trends in Engineering and Research e-issn No.: , Date: April, 2016

5484BN/R7DC-AHJB/XR/MS(ELA)

PRACTICAL UNCERTAINTY BUDGETS FOR SPECTRAL MEASUREMENTS OF LEDS

NPG-151 IPC-4101C//127

Parameter Symbol Hi-Eff Red Yellow Green Unit

Control of Manufacturing Process

(2) this disclaimer and the notice below accompany the Document at all times.

Standard Practice for Heat Aging of Plastics Without Load 1

Know Your Uncertainty

FORMULATION OF A NEW LIQUID FLUX FOR HIGH TEMPERATURE SOLDERING

What have we learned from the LCLS injector?*

DEVELOPMENT OF IMPROVED METHODS FOR CHARACTERISING THE CURE OF COMPOSITE MATERIALS

nano-ta: Nano Thermal Analysis

high energy state for the electron in the atom low energy state for the electron in the atom

AB3528-XXW-00. PIN 1 Mark 0.90(.035)

Make Your Cubesat Overnight and Put it in Any Orbit (Well almost)

Standard Practices for Air Speed Calibration Testing

1. Automotive : Dashboards, stop lamps, turn signals. 2. Backlighting : LCDs, Key pads advertising. 3. Status indicators : Comsumer & industrial

Output intensity measurement on a diagnostic ultrasound machine using a calibrated thermoacoustic sensor

Principles of Almen Strip Selection

Surface Mount UV LED. NUVA33 Series PART NUMBERING SYSTEM. WAVELENGTH CODES Code Nominal Wavelength

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:

Implementation of velocity measurement as intensity verification in production

Abstract. 1. Introduction

Determining cure profile and post-cure shrinkage of photopolymers using UV accessory on a rotational rheometer

VSMOW Triple Point of Water Cells: Borosilicate versus Fused- Quartz

Technologies VII. Alternative Lithographic PROCEEDINGS OF SPIE. Douglas J. Resnick Christopher Bencher. Sponsored by. Cosponsored by.

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

Physical Properties Testing Technical Bulletin

Supplementary Materials for

50 W Power Resistor, Thick Film Technology, TO-220

ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS

Power Dissipation Pd 120 mw Forward Current I F 30 ma Peak Forward Current *1 I FP 100 ma 佰鴻工業股份有限公司

ENVIRONMENTAL EFFECTS OF EARLY AGE AND LONG TERM RESPONSE OF PCC PAVEMENT

Physics 313: Laboratory 8 - Polarization of Light Electric Fields

custom reticle solutions

NP-180R. U.L. file number E98983

2510 PREPREG SYSTEM. Industry Database FAA approved design allowable values (AGATE methodology), results in a low cost one-batch equivalency.

Demonstrating Competency and Equivalency of Two Commercial SPRT Calibration Facilities

OPTICAL PROPERTIES OF THE COOKIT SOLAR COOKER

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Suitable for all SMT assembly methods. 6. Compatible with infrared and vapor phase

DATA SHEET ARRAY CHIP RESISTORS YC/TC 164 (8Pin/4R; Pb Free) 5%, 1% sizes

MEMS Metrology. Prof. Tianhong Cui ME 8254

Thin Wafer Handling Challenges and Emerging Solutions

Electrical connection network within an electrically conductive adhesive

1.0(.039)± R0.25(.010) 2.0(.079)± (.020) Cathode Mark. Cathode

Multi-element process analyzer

XBC300 Gen2. Fully-automated debonder and Cleaner

Stray Light Rejection in Array Spectrometers

佰鴻工業股份有限公司. 佰鴻工業股份有限公司 DEVICE NUMBER:BL-HKB36A-TRB 孫

Chromatography & instrumentation in Organic Chemistry

Uncertainty Analysis of Experimental Data and Dimensional Measurements

1110. Measurement of stresses in the vibrating elements of a printing device

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

Measurement of heat transfer coefficients for polymer processing simulation

DEVELOPMENT OF A NEXT-GENERATION ENVIRONMENTAL CHAMBER FACILITY FOR CHEMICAL MECHANISM AND VOC REACTIVITY RESEARCH

Volume # 7 Issue # 8 August 2015 Rs.5/- Volume # 7 Issue # 8 August-September 2015 INTERNATIONAL.

Title: Cesa-extend a User Friendly Technology to Enhance Reprocessing and Recycling of Condensation Plastics

John Williams, David Miller and Carl Deckard Clemson University Clemson, SC 29634

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Beam halo formation in high-intensity beams

Multi-residue analysis of pesticides by GC-HRMS

Resistance : R = ρ( ) units are Ohms ( 14 ) Resistor 100 ohms

Homogeneity of optical glass

CL-L102-C7D. 1. Scope of Application. These specifications apply to LED package, model CL-L102-C7D. 2. Part code

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cut-and-Paste Organic FET Customized ICs for Application to Artificial Skin

Photomasks. Photolithography Evolution 9/11/2004 ECE580- MPE/MASKS/PHOTOMASKS.PPT

Release Liners: The Most Important Trash You ll Ever Buy. by Charles Sheeran

Thermal Interface Materials (TIMs) for IC Cooling. Percy Chinoy

POE Practice Test - Materials

Technical Procedure for General Laboratory Equipment

PRODUCT SPECIFICATIONS

Fast and Ultimate Vibration Field Solution: From Problem Detection to Field Performance Validation

In fact, we are going to be sneaky and use Hess s Law to determine the heat of magnesium combustion indirectly. Go to the website:

Strain Measurement. Prof. Yu Qiao. Department of Structural Engineering, UCSD. Strain Measurement

Larry A. DeWerd, PhD, FAAPM UW ADCL & Dept. Medical Physics University of Wisconsin

Cornell Caltech Atacama Telescope Project Status. Simon Radford 2005 October 10. Study Status

TRACEABILITY STRATEGIES FOR THE CALIBRATION OF GEAR AND SPLINE ARTEFACTS

Technical Data Sheet. Pb Free. Specification GR101 SSC. Customer. Rev. 02 January 서식번호 : SSC- QP (Rev.0.

Ocean Optics XIV Conference, Kona, Hawaii 1998

TEST REPORT (Self-Tested Data)

TEST REPORT (Self-Tested Data)

Transcription:

Dimensional Issues in Stereolithography Abstract David L. Winmill, Daniel M. Hoopes and Suresh S. Jayanthi DuPont Somos, Two Penn's Way, New Castle, DE 19720-2407 New stereolithography photopolymers have recently been introduced that provide a wider range of functional properties similar to those of high-density polyethylene. One of the important criteria for these materials is the dimensional accuracy and stability in end-use applications as mold masters or the actual functional parts. This work investigates the dimensional stability of one of these new materials with varying amounts of exposure during build. The effect of aging on the part dimensions is reported. The result of environmental humidity extremes at ambient temperature on part dimensions is investigated and compared for parts made from two different families of stereolithography resins, namely DuPont Somos 7100 and Somos 8100. Introduction Rapid prototyping technologies have gone through several advances in the last few years. Stereolithography in particular has seen some dramatic improvements due to equipment changes and innovations in photopolymers. The primary driving forces for new photopolymers are the quest for improved mechanical properties and dimensional stability. Prototypes made by stereolithography now offer high resistance to harsh environmental conditions. For example, some of the new materials now provide heat deflection temperatures over 100 c C and can also be used in water applications without an appreciable drop in physical properties. More recent stereolithography materials are providing properties similar to commonly used plastics like high-density polyethylene and ABS. All of this has significantly increased the range of applications in which stereolithography can now be used. To achieve a more enduring growth of these applications, a better appreciation of the changes that can occur in the properties of these materials is needed. The variations in the physical properties with different fabrication strategies, aging under different environmental conditions and endurance testing are becoming more important as these materials are being used to validate not only the design but also the functional intent of the prototypes. This paper focuses primarily on aspects of the dimensional behavior of these new classes of materials and also highlights some of the technological limitations that we have to live with. In trying to build dimensionally accurate and stable prototypes many issues have to be monitored. These include the nature of the geometry and the subsequent slice files as well as the orientation of the part on the build platform. The aspects that are given more attention here are the stereolithography machine calibration, the photopolymer resin being used, the fabrication 303

style used to build parts, their subsequent post-curing and eventually the environmental conditions that they experience. The experimental. studies reported in this paper. are based on two high performance materials for stereolithography. One ofthese is a high strength, high heat deflection temperature and humidity tolerant material.called Somos 7110. The other is a high flexibility and high impaqt strength material called Somos 8100 or 8110 that will be commercialized in the third quarter of this year. This work will first highlight the contribution of machine calibration as a sourqe of error in the production of stereolithography parts. Secondly, it characterizes the influence of laser exposure and post-exposure on dimensional stability. Thirdly, it shows the influence ofenvironmental conditions on the dimensional stability of finished parts. Finally, the findings are summarized and observations are made with the view to improving the dimensional behavior. Recent Work In 1997, Paul Jacobs (1) first showed that processes such as stereolithography exhibit non-uniform shrinkage behavior and contain a random noise shrinkage component. Following up on Jacobs' work, Tom Mueller (2) expanded the concepts into a more general model that would include the effects of pattern accuracy as well as the shrinkage of injection-molded plastic. This would allow tolerances to be predicted for the molded parts rather than the tool. Prior to these two works, significant effort was focused on quantifying the achievable accuracy levels using an industry recognized "User-Part" (3). This particular diagnostic has been used to optimize the compensation factors necessary to improve achievable accuracy. It is also used as a confirmation diagnostic to assess the realistic tolerances achievable in a typical stereolithography machine after all compensation factors have been applied. Figure 1 illustrates the distribution of error across the part for a compensated diagnostic part. As the figure shows there is a high degree (± 6 mil) of random noise. Contributing to the noise are the machine calibration status, process characteristics, possible non-uniform shrinkage behavior of the stereolithography material and the measurement techniques. 0.0075 0.0025 0.0025 0.0075 0.0 0.4 0.6 1.0 2.1 2A 2J 4~ 4.6 4.9 5~ 6.7 7.1 7.4 85 89 9.1 95 Figure 1: Distribution of Random Noise in a Compensated SL Diagnostic Part (Measured Error on Y axis; CAD Dimensions on X axis) 304

System Status and. Dimensional Accuracy In order to investigate the system calibration status and the effect of different exposures on part dimensions, Somos 8100 was used in a 3D System's SLA - 500 stereolithography machine. Sixteen square boxes (2 inch by 2 inch) were designed and spaced evenly on the platform in a four by four array. The CAD for the boxes featured sidewalls as well as an internal circular boss and flat panel. Each of the four columns of boxes received a different hatch overcure of -2, 0, 2, or 4 mils whereas all the other build conditions stayed the same. All of these were quite normal, such as 6 mil layers, ACES build style (4 mil hatch spacing), and a box hatch. The boxes were built without any material shrinkage compensation. A beam width compensation of 6 mils was used. Just after the parts were imaged the X and Y dimensions of the boxes were measured and found to be substantially different from the chosen CAD values. Initial Part Size Variation over the SLA - 500 Platform (Part minus CAD Dimension in mils) Row Column Number Number 1 2 3 4 1 7 10 5 2 2 6 9 3 3 3 6 5 5 3 4 7 8 4 2 Table 1: Dimensional differences for the X dimensions of the two-inch square boxes As shown above in Table 1, the measured X dimensions were all larger than the desired CAD dimension, and the largest errors tended to occur on the left-hand side of the platform. In the case of the Y dimensions (see Table 2 below), all the dimensions were smaller than intended and the greatest errors occurred on the right hand side of the platform. Clearly then, this machine has a poorly calibrated platform. Therefore the initial green state dimensions were taken as the starting point from which to measure any changes that might occur due to aging or post-cure procedure. 305

Initial Part Size Variation over the SLA - 500 Platform (Part minus CAD Dimension in mils) Row Column Number Number 1 2 3 4 1-12 -10-14 -14 2-12 -11-15 -15 3-12 -12-13 -16 4-11 -8-13 -15 Table 2: Dimensional differences for the Y dimensions ofthe two-inch square boxes In the future it would seem to be a good idea if the platform calibration was measured with a photo responsive film such as Dylux before imaging the parts. The values obtained from this could then be used as the initial values and would be completely free of any effects (expected to be small directly after a build) of the photopolymer resin. Dimensional Accuracy after Imaging After measuring the initial dimensions as described above, two boxes from each hatch over-cure exposure were post-cured with UV light for one hour in a 3D Systems' Post Cure Apparatus. A little later the extents, the circular boss and the panel thickness were measured. The results for the extents (see Figure 2) show that the lowest exposures (-2.0 mils hatch overcure) actually produce an expansion ofthe parts. 4.00 -len z- o!!. wz ~" 3.00 «-I 2.00 -w 1.00 :E«-:r: 0.00 0-1.00-2.00-4.0,.(),,.,..,, -2.0 0.0 2.0 4.0 6.0 HATCH OVERCURE (MILS) X& y- uv I I.0- - X & Y - 1 DG I Figure 2: Dimensional Behavior with Different Hatch Over-cures for Somos 8100 The amount of expansion falls with increasing exposure and reaches zero with 4.0 mils hatch over-cure. The boxes from each hatch over-cure that were not post-cured were left for a day at ambient conditions (labeled 1 DO) and again measured. These data are rather scattered

but show a general trend of the lower exposure to cause shrinkage as the parts age in their green state. The circular boss showed similar effects, but the data was noisier due to the smaller dimension. The panel was too thin (80 mils) to determine any dimensional changes in the Y direction. In order to further investigate the effect of hatch over-cure on dimensional stability in the green state, tensile bars (150 mm long) were measured for four different exposure conditions over a Erolonged period of time after imaging (Figure 3). These parts were made on a DuPont Somos stereolithography machine with 2-mil scan spacing and a raster scan with a spot diameter of about 6 mil. Again the lowest exposures gave the most change, and in the case of parts made with! mil over-cure the dimensional change was + 0.8% after 30 days which equates to 8 mil per inch. However, in the case of higher hatch over-cure exposures of 8 and 9 mil, there was almost no dimensional change with time. 0.8 c 0.6 CI: 0_ 0.4 e~ 0-0.2 J:::; c C') 0.2 i ~...J -0.2 ~ -0.4-0.6 r? r~"'"... V.------ ~ L- V.. -...... r~ -.....-......... _.. IIll.. III III.-.. ~ Ē ----' 1 mil ----9;1 ~ ~ ~ ~_: ~:: I -0.8 o 10 20 30 CAD Length =5.9055 in. Figure 3: Dimensional Behavior with Different Hatch Over-cures for Somos 8100 Green Tensile Bars at Ambient Conditions Environmental Effects and Dimensional Stability The effect of the environlnent after the parts were imaged, cleaned.and post-cured was determined on a set of 6 inch tensile bars that had been kept at ambient conditions for about a month. Three sets of six bars made from either Somos 7110 or Somos 8110 were sanded lightly, especially on the down-facing surfaces, to remove any remaining supports so that they would be suitable for repetitive weighing. Each set ofbars was then left in a large glass jar either at ambient lab temperature (21 C) and humidity, immersed in distilled water,. or at 0 %. relative humidity (RH). At the start and approximately every five days after that each bar was weighed and the length measured. The bars made froll1 Somos 7110 and held at 0 % RH lost an average of0.003% weight per day, but their weight was stabilizing. The bars at ambient conditions (Air) actually gained weight slightly presumably due to a slightly increasing humidity in the laboratory with the onset 307

of summer. The bars in water gained a total of 1.2 % weight over 47 days (an average of 0.03 % Wt per day) and had not yet reached equilibrium (Figure 4). Imaged with 6 mil Layers, 4 mil Hatch Over-cure, UV post-cured ~ 1040 - :E 1.20,2) ~ 1.00 11 0.80.; ~ 0.60 o E 0.40,g 0.20 CD 0) 0.00 Ii tj -0.20 / ~-./ V7 /' ~ ~- ---... ~ ~ --.""... - - - - - - --- - - o 10 20 30 40 50 ~ Air --H20 -.-O%RH Initial Weight = 25.5 g Figure 4: Weight change with Time for Somos 7110 Tensile Bars at 21 C 0.30! 0.25.c:: '& c 0.20 CD..I ~ 0.15 - ~ 0.10. 0.05 1i ~ 0.00 Imaged with 6 mil Layers, 4 mil Hatch Over-cure, UVpost-cured.- - ---.....-........ T y.- - ::.: --..~~ ~ _/ '"..... ~ - ~...... o 10 20 30 40 50 I -+-Air I I-il-H20 I-.-O%RHj CAD Length =5.9055 in. Figure 5: Change in Length with Time for Somos 7110 Tensile Bars at 21 C The overall effect on the length of the Somos 7110 bars was very similar to the weight change (Figure 5). The bars at 0 % RH lost length throughout the study, but then seemed to gain some at the end. The length of the bars at ambient conditions (Air) varied slightly presumably due to varying humidity in the laboratory. The bars in water gained a total of 0.2 % length over 47 days (an average of0.004 % per day) but had not yet reached equilibrium. 308

The bars made from Somos 8110 and held at 0 % RH lost an average of 0.006 % weight per day, but their weight was stabilizing. The bars at ambient conditions (Air) actually gained weight slightly presumably due to a slightly increasing humidity in the laboratory with the onset of summer. The bars in water gained a total of 2.4 % weight over 48 days (an average of 0.05 Wt% per day) bufhad not yet reached equilibrium (Figure 6). Imaged with 6 mil La~rs, 4. mil Hatch Over-cure, uvpost-cured ~ 3.00 1: m 2.50 ~ 2.00 1i c 1.50 OJ 1: o 1.00 E e 0.50 - & 0.00 c co./ ~ - _..-J~ ------- ~ --.7 fa ~ & 'II"" 'II"" --...I-.. ~... - - - - - - - - t3-0.50 o 10 20 30 40 50 --+-PJr~ ---H20 ~o.%rh Initial Weight=24.5 g Figure 6: Weight change with TimeforSoIb.os@ 8110 Tensile Bars at 21 C '0 1.00 ~ 0.90.c ~ 0.80 ~ 0.70 ~ ~:~~ g 0.40.:: 0.30 c.. Imaged with emil La~rs, 4mil Hatch Over-cure, UVpost-cured.~..,.-/ & I~. ---... T.6..2 0.20.s; 0.10! 0.00 o 10 20 30 - '/- - ----.>...~- ~ ----- A ~...... - -. -- --.. -" 40 50 --+-PJr ---H20 -.-OO/ORH CAD Length = 5.9055 in. Figure 7: Change in Length with Time for Somos@ 8110 Tensile Bars at 21 C The overall effect on the length of the bars was very similar to the weight change (Figure 7). The bars at 0% >RH lostlengththroughout the study, but then gained some at the end. The length of the bars at ambient conditions (Air) varied slightly presumably due to varying humidity in the laboratory. The bars in water gained a total of 0.6 %length over 48 days (an average of 0.013 Wt % per day) but had not yet reached equilibrium even after that length of time. 309

Conclusions Tobui1~dill1en~ion~ll ia.9cllratepartsb~ stei"eqlithography'i.machinecalipration isavery important consideration thatshould\ not be overlooked. A way of measuring the.imaging accuracy before building. parts has been proposed. Ithas been shownthattherandomnoisecomponentof the stereolithography process can a significant contributor to <the overall part accuracy. As more attention is given to the individl1~componentsthat<affect dimensional change and therefore random noise, the achievableaccui"acy levels willimprove. The amount ofexposure used during the part build affects the dimensional stability of the part after building. In general, higher exposure provides more stable parts, whether they remain in the green state or ifthey are post-cured with UV radiation in the conventional way. This has been shown to be the case with Somos 8100, one member of a family of stereolithography resins that produce flexible, high impact strength parts. The effect of exposure on other stereolithography resins will be the subject of future studies. Afterpartshave.been built and post-cured it has been shown that environmental conditions,in particularhulllidity,. have a pronounced effect on the dimensional stability. This occurred for parts made frqm both.ofthestereolithography resinstested, namelysomos 7110 (a general purpose, high strength,... highheatdefleption temperature resin)... andsolllos.. 8110, although the later resin changed the. most..for six.,inch tensile bars in some environments, equilibration had notoccurred.over a 47-day period. It was shown that parts left at ambient room conditions.are susceptible to dimensional changes due to humidity changes. Further studies are underway to look into these issues at a greater depth and will be reported in the future. References 1. Paul F. Jacobs, "The Effect of Shrinkage Variations on Rapid Tooling Accuracy" presented at the 4 th Annual Eugene C. Gwaltney Manufacturing Symposium, RPMI, Georgia Institute of Technology, Qctober 1-2, J~97. 2. Tom Mueller, "A Model to Predict Tolerances in Parts Molded in Pattern Based Alternative Tooling" presented atthe RapidPrototyping and Manufacturing Conference, May 19-21, 1998. 3. Edward G. Gargiulo and Suresh S. Jayanthi, "Current State of Accuracy in Stereolithography" presented at the NIeasurements and Standards Issues in Rapid Prototyping Symposium organized by NIST, October 16-17, 1997. Acknowledgements This work has been made possible by the active participation of some of our valued customers in ourtechnical studies. We would also like to acknowledge the help we obtained from our colleagues within the Somos Group and from other divisions within DuPont. 310