Direct-operated 2/2-way solenoid valves Type EV210B

Similar documents
Direct-operated 2/2-way compact solenoid valves Type EV210A

Solenoid valves 2/2-way direct-operated type EV210A

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

A wide selection of pipe and orifice sizes is offered. Valves are available with threaded ports in brass and stainless steel.

Pressure transmitters for industrial applications MBS 32 and MBS 33

5/2-5/3 SPOOL VALVES MULTIFUNCTION air operated or solenoid air operated with subbase ISO 5599/1 sizes 1, 2 and 3

Solenoid valve Types EVR 2 - EVR 40

Cartridge Valves Technical Information. Quick reference

air and solenoid air operated 5/2-5/3 ISO 5599/01 - Size 2

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

ED 701 General Industry Pressure Transmitter

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil

Solenoid valves Type EVUL

compact ejector, Series ECS with release valve with silencer with non-return valve, With filter vacuum switch: electronic 1x PNP and 1x analog

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

2-way proportional throttle valve for block installation

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

FLOW SENSOR FOR LIQUID MEDIA Serie 210

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Metal oil filler and air breather filler caps. Bayonet connection. Reservoir holes. TA46 B (Materials)

Flow rates to 750 l/min

Cooling Water Flow Regulator

VOLUMEC. Valve Position Indicator 5

Flow rates to 750 l/min

Application PN 16 / 40 DN Product features. Compact overall height Body shape gives optimum flow characteristic

Direct Operated Type Solenoid Operated Proportional Directional Control Valve

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

Pressure Transmitter ED 701

DOMESTIC HOT WATER PUMPS WITH FIXED-SPEED MOTOR, 3x400V AP-, AKP- and AEP- series, threaded G1/2 G1 ¼ LOREM IPSUM JE ZULT MAAR 60 HZ.

Size A DIN EN

High Pressure fi lters. FMP 039 series. Maximum pressure up to 110 bar - Flow rate up to 80 l/min. High Pressure fi lters

Working pressure. 320 bar. Style T. Style D. Style S. Style B B B D.I. D.I. D.I. D.I.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Pilot operated 2 port solenoid valve (general purpose valve) Standard specifications NC (normally closed) type C C. 2 /s) Starting

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

CMA - B - C - D - CMR

SINGLE IMPELLER CENTRIFUGAL ELECTRIC PUMPS in cast iron

Working pressure. 420 bar. Style T. Style B. Style D Style V Style Z. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

OEM Flow sensor for liquid media type 200

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

W 30 Photoelectric proximity switches: Clear signals even with low remission

P303 Pressure Regulator

PR CYCLONE SECONDARY SHUTOFF

ISO mm ISO mm. Nl/min. Nl/min. Nl/min. Nl/min. ISO /2 Distributors. ISO Interface. OVERSIZED interface (UNIVER original)

Normally Closed (N.C.), Normally Open (N.O.), Common (C.O.)

VALVES B D E B D A. ISO /2 Valves CHARACTERISTICS CODIFICATION KEY. BD 18 mm. BD 26 mm

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

4/3-way servo solenoid directional control valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

Maximum pressure 420 bar Flow rate to 152 l/min. 560 bar. 140 l/min. Flow rate l/min FMM 050 1/2 1,50 3/4 1,00. Δp bar 0,50 0,00 FHA 051 1,50 1,00

Polígono Indutrial O Rebullón s/n Mos - España -

High Pressure fi lters. FHB series. Maximum working pressure up to 32 MPa (320 bar) - Flow rate up to 485 l/min

SERIES FMP. Working pressure. 280 bar. Style D Style V Style Z. Style T. Style B. Style S B B D.I. D.I. D.I. D.I. D.I. D.I.

Flow rates to 475 l/min

Globe Valve, Metal. Sectional drawing. *see information on working medium on page 2

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

Series P0 Electronic Metering Pump. Specification Sheet and Assembly Details Manual No : 1934, 1843 Rev. : C, D Rev. Date : 6/01, 10/2015

High Pressure fi lters. FMP series. Maximum pressure up to 320 bar - Flow rate up to 475 l/min. High Pressure fi lters

Suction fi lters. SF series. Flow rate up to 160 l/min. Suction fi lters

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

Polígono Indutrial O Rebullón s/n Mos - España -

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

COMMON BLACK IRON & BLADE PARTS

331 Low & Medium Pressure filters

PARTS LIST GAS BOILERS MODELS: CG320 (E) CG325 (E) CG330 (E)

2/2-3/2 POPPET VALVES FOR VACUUM (1/8"-6/4") Series AG

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

High Pressure fi lters

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

Universal type Port size: M5, Rc1/8, Rc1/4. Max. working. pressure

OEM Flow sensor for liquid media type 200

359 Low & Medium Pressure filters. LMP series. Maximum pressure up to 30 bar - Flow rate up to 2400 l/min. Low & Medium Pressure fi lters

High Pressure fi lters. FHB series. Maximum pressure up to 320 bar - Flow rate up to 485 l/min. High Pressure fi lters

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.

Flow Divider Type MH2FA, Series 4X (Differential lock) Size 12 to 32 up to 420 bar up to 300 L/min

Differential indicators

High Pressure fi lters. FHM series. Maximum pressure up to 320 bar - Flow rate up to 450 l/min. High Pressure fi lters

379 Low & Medium Pressure filters. LMD 211 series. Maximum pressure up to 60 bar - Flow rate up to 330 l/min. Low & Medium Pressure fi lters

OEM Flow sensor for liquid media type 200

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High Pressure fi lters. FHA 051 series. Maximum working pressure up to 56 MPa (560 bar) - Flow rate up to 140 l/min. High Pressure fi lters

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

CV3000 Series. Characterized Insert Control Valves

Flow rates to 485 l/min

387 Low & Medium Pressure filters

Conductivity sensor for hygienic applications

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

PN LINE. PN Line. PX Line. PA Line. PU Line PX LINE. PV Line PA LINE & TUBINGS PU LINE PV LINE. Brass Push-in fittings

Transcription:

Data sheet Direct-operated 2/2-way solenoid valves Type EV20B EV20B covers a wide range of direct-operated 2/2-way solenoid valves for universal use. EV20B is a very robust valve program with high performance and can be used in all kind of tough working conditions in demanding industrial applications such as control and closage. Features and versions: y For water, oil, compressed air and similar neutral media. y Flow range: 0 8 m 3 /h y Differential pressure: 0 30 bar y Media temperature: -30 40 C y Ambient temperature: Up to 80 C y Coil enclosure : Up to IP67 y Tread connections: G 8 G y DN.5 25 y Viscosity: Up to 50 cst y The valves can be used for vacuum y EV20B brass version for water, oil, compressed air and similar neutral media y EV20B stainless steel version for neutral and aggressive liquids and gasses y Also available with NPT thread. See separate datasheet IC.PD.200.2A.02

EV20B brass valve body, NC Conn. ISO 228/ G 8 G 4 G 3 8 G 2 G 3 4 G Seal Orifice material size K v value [m³/h] BA 9 Differential pressure min. to max. [bar] /coil type 2 ) BA 5 BD 5 BB 0 BB 8 BG 2 BG 20 Media temperature min. to max. [ C] Code number 0.08 0 30 0 30 0 30 0 30 0 30 0 30 0 30-30 20 032U570.5 0.08 0 30 0 30 0 30 0 30 0 30 0 30 0 30-0 00 032U5702 2.0 0.5 0 30 0 20 0 30 0 30 0 30 0 30 0 30-0 00 032U5704 0.30 0 5 0 9 0 24 0 20 0 3 0 30 0 25-30 20 032U5705 3.0 0.30 0 5 0 9 0 24 0 20 0 3 0 30 0 25-0 00 032U5706.5 0.08 0 30 0 30 0 30 0 30 0 30 0 30 0 30-0 00 032U3629 0.5 0 30 0 20 0 30 0 30 0 30 0 30 0 30-30 20 032U5707 2.0 0.5 0 30 0 20 0 30 0 30 0 30 0 30 0 30-0 00 032U5708 0.30 0 5 0 9 0 24 0 20 0 3 0 30 0 25-30 20 032U5709 3.0 0.30 0 5 0 9 0 24 0 20 0 3 0 30 0 25-0 00 032U570 0.55 0 8 0 3.5 0 2 0 0 0 4.5 0 3 0 9-30 20 032U3600 4.5 0.55 0 8 0 3.5 0 2 0 0 0 4.5 0 3 0 9-0 00 032U360 0.70 0 2.5 0.0 0 3.3 0 4.0 0 2.0 0 6 0 4.5-30 20 032U3602 6.0 0.70 0 2.5 0.0 0 3.3 0 4.0 0 2.0 0 6 0 4.5-0 00 032U3603 0.30 0 5 0 9 0 24 0 20 0 3 0 30 0 25-30 20 032U3642 3.0 0.30 0 5 0 9 0 24 0 20 0 3 0 30 0 25-0 00 032U3643 0.55 0 8 0 3.5 0 2 0 0 0 4.5 0 3 0 9-30 20 032U3605 4.5 0.55 0 8 0 3.5 0 2 0 0 0 4.5 0 3 0 9-0 00 032U3606 0.70 0 2.5 0.0 0 3.3 0 4.0 0 2.0 0 6 0 4.5-30 20 032U3607 6.0 0.70 0 2.5 0.0 0 3.3 0 4.0 0 2.0 0 6 0 4.5-0 00 032U3608.00 0.5 0 0.5 0 2.0 0 2.0 0.2 0 3 0 2.5-30 20 032U3609 8.0.00 0.5 0 0.5 0 2.0 0 2.0 0.2 0 3 0 2.5-0 00 032U360.50 0 0.8 0 0.3 0. 0.2 0 0.6 0.6 0.3-30 20 032U36 0.0.50 0 0.8 0 0.3 0. 0.2 0 0.6 0.6 0.3-0 00 032U362 2.50 0 0.25 0 0.4 0 0.3 0 0.5 0 0.45 0 0.4-30 20 032U363 5.0 2.50 0 0.25 0 0.4 0 0.3 0 0.5 0 0.45 0 0.4-0 00 032U364.00 0.5 0 0.5 0 2.0 0 2.0 0.2 0 3 0 2.5-30 20 032U365 8.0.00 0.5 0 0.5 0 2.0 0 2.0 0.2 0 3 0 2.5-0 00 032U366.50 0 0.8 0 0.3 0. 0.2 0 0.6 0.6 0.3-30 20 032U367 0.0.50 0 0.8 0 0.3 0. 0.2 0 0.6 0.6 0.3-0 00 032U368 2.85 0 0.25 0 0.4 0 0.3 0 0.5 0 0.45 0 0.4-30 20 032U369 5.0 2.85 0 0.25 0 0.4 0 0.3 0 0.5 0 0.45 0 0.4-0 00 032U3620 4.50 0 0.28 0 0.2 0 0.4 0 0.35-30 20 032U362 20.0 4.50 0 0.28 0 0.2 0 0.4 0 0.35-0 00 032U3622 8.00 0 0.25 0 0.09 0 0.35 0 0.2-30 20 032U3623 25.0 8.00 0 0.25 0 0.09 0 0.35 0 0.2-0 00 032U3624 ) 40 C / 3.6 bar low pressure steam, orifice DN.5 4.5. - Low pressure steam: DN.5 3 Use coil type BB or BG. DN 4.5 Use coil type BG 2 ) Pressure range can be extended to use in rough vacuum, typically up to 99% vacuum (0 mbar), depending on the application. IC.PD.200.2A.02 2

Technical data, EV20B NC Type EV20B.5 EV20B 2 EV20B 3 EV20B 4.5 EV20B 6 EV20B 8 EV20B 0 EV20B 5 EV20B 20 Time to open [ms] ) 0 20 20 20 30 40 40 Time to close [ms] ) 20 20 20 30 50 50 70 Max test pressure [bar] 52.5 52.5 37.5 37.5 24 24 24 ) The times are indicative and apply to water. The exact times will depend on the pressure conditions. EV20B 25 Installation Tightness Ambient temperature Viscosity Materials Optional, but vertical solenoid system is recommended Internally: Better than 8.3 x 0 2 mbar l/sec (5ccm air per min.) Externally: Better than x 0 3 mbar l/sec (00% H e ) Max. 80 C (depending on coil type) Max. 50 cst Valve body Brass W.no.2.0402 Armature Stainless steel W.no..405 / ASIS 430FR Armature tube Stainless steel W.no..4306 / ASIS 304L Armature stop Stainless steel W.no..405 / ASIS 430FR Springs Stainless steel W.no..4306 / ASIS 30 Seal material: See specific data in table. Dimensions and weight Type Weight gross valve body without coil [kg] L B BA / BD B BB / BE BG EV20B.5 / EV20B 2B, NC 0.5 35 34 32 46 67 2 70 EV20B 3 / EV20B 4.5, NC 0.20 38 34 32 46 67 70 EV20B 6B, NC 0.22 46 34 32 46 67 6 73 EV20B 8 / EV20B 0B, NC 0.29 49 34 32 46 67 6 73 EV20B 5B, NC 0.45 58 53 32 46 67 3 93 EV20B 20B, NC.0 90 58 32 46 67 8 92 EV20B 25B, NC.0 90 58 32 46 67 23 96 H H Dimensions Danfoss IC.PD.200.2A.02 3

EV20B brass valve body, NO Conn. ISO 228/ Seal material Orifice size K v value [m³/h] BA 9 Differential pressure min. to max. [bar] /coil type 2 ) BA 5 BD 5 BB 0 BB 8 BG 2 BG 20 Media temperature min. to max. [ C] Code number G 8.5 0.08 0 30 0 30 0 30 0 30 0 30 0 30 0 30-30 20 032U3630 G 8.5 0.08 0 30 0 30 0 30 0 30 0 30 0 30 0 30-0 00 032U363 G 8 2.0 0.5 0 2 0 2 0 2 0 2 0 2 0 2 0 2-30 20 032U3632 G 8 2.0 0.5 0 2 0 2 0 2 0 2 0 2 0 2 0 2-0 00 032U3633 G 4 2.0 0.5 0 2 0 2 0 2 0 2 0 2 0 2 0 2-30 20 032U3636 G 4 2.0 0.5 0 2 0 2 0 2 0 2 0 2 0 2 0 2-0 00 032U3637 G 4 3.0 0.30 0 5 0 5 0 5 0 5 0 5 0 5 0 5-30 20 032U3638 G 4 3.0 0.30 0 5 0 5 0 5 0 5 0 5 0 5 0 5-0 00 032U3639 G 4 4.5 0.55 0 2 0 2 0 2 0 2 0 2 0 2 0 2-30 20 032U3640 G 4 4.5 0.55 0 2 0 2 0 2 0 2 0 2 0 2 0 2-0 00 032U364 ) 40 C / 3.6 bar low pressure steam, orifice DN.5 4.5. - Low pressure steam: DN.5 3 Use coil type BB or BG. DN 4.5 Use coil type BG 2 ) Pressure range can be extended to use in rough vacuum, typically up to 99% vacuum (0mbar), depending on the application. Technical data, EV20B NO Type EV20B.5 EV20B 4.5 Time to open [ms] ) 20 Time to close [ms] ) 20 ) The times are indicative and apply to water. The exact times will depend on the pressure conditions. Installation Max. test pressure Tightness Ambient temperature Viscosity Materials Optional, but vertical solenoid system is recommended 50 bar Internally: Better than 8.3 x 0 2 mbar l/sec ( 5ccm air per min) Externally: Better than x 0 3 mbar l/sec (00%He) Max. 80 C (depending on the coil type, see data for the coil selected) Max. 50 cst Valve body Brass W.no. 2.0402 Armature Stainless steel W.no..405 / AISI 430FR Armature tube Stainless steel W.no..4306 / AISI 304L Armature stop Stainless steel W.no..405 / AISI 430FR Springs Stainless steel W.no..430 / AISI 30 Seal material See specific valve data Dimensions and weight Type Weight gross valve body without coil [kg] L B BA / BD B BB / BE BG EV20B.5 / EV20B 2B, NO 0.5 35 34 32 46 67 2 70 EV20B 3 / EV20B 4.5, NO 0.20 38 34 32 46 67 70 Dimensions H H Danfoss IC.PD.200.2A.02 4

EV20B stainless steel body, NC Conn. ISO 228/ G 8 Seal material K v value [m³/h] Orifice size BA 9 BA 5 Permissible differential pressure [bar] BD 5 BB 0 BB 8 BG 2 BG 20 Media temperature min. to max. [ C] Code number 0.5 2.0 0 30 0 20 0 30 0 30 0 30 0 30 0 30-30 20 032U3647 G 8 0.30 3.0 0 5 0 9 0 24 0 20 0 3 0 30 0 25-30 20 032U3649 G 4 0.5 2.0 0 30 0 20 0 30 0 30 0 30 0 30 0 30-30 20 032U365 G 4 0.30 3.0 0 5 0 9 0 24 0 20 0 3 0 30 0 25-30 20 032U3653 G 8 0.55 4.5 0 8 0 3.5 0 2 0 0 0 4.5 0 3 0 9-30 20 032U3655 ) 40 C / 3.6 bar low pressure steam, orifice DN.5 4.5. - Low pressure steam: DN.5 3.0 Use coil type BB or BG. DN 4.5 Use coil type BG Technical data, stainless steel Type EV20B 2 EV20B 4.5 Time to open [ms] ) 20 Time to close [ms] ) 20 ) The times are indicative and apply to water. The exact times will depend on the pressure conditions. Installation Optional, but vertical solenoid system is recommended Max. test pressure 50 bar Tightness Internally: Better than 8.3 x 0 2 mbar l/sec (5ccm air per min) Externally: Better than x 0 3 mbar l/sec (00%He) Ambient temperature Max. 80 C Viscosity Max. 50 cst Materials Valve body Stainless steel W.no..4404 / AISI 36L Armature Stainless steel W.no..405 / AISI 430FR Armature tube Stainless steel W.no..4306 / AISI 304L Armature stop Stainless steel W.no..405 / AISI 430FR Springs Stainless steel W.no..430 / AISI 30 Seal material See specific valve data Dimensions and weight B Type EV20B 2 / EV20B 3 / EV20B 4.5, NC Weight gross valve body without coil [kg] L B BA / BD BB / BE BG H 0.25 35 35 32 46 67.5 75 H Dimensions Danfoss IC.PD.200.2A.02 5

Mounting angle Below coils can be used for EV20B Coil Type Power consumption Enclosure Features BA / BD, screw on 9 W AC 5 W DC IP00 with spade connector IP20 with protective cap, IP65 with cable plug BB, clip on 0 W AC 8 W DC IP00 with spade connector IP20 with protective cap, IP65 with cable plug BE, clip on 0 W AC 8 W DC IP67 With terminal box BG, clip on 2 W AC 20 W DC IP67 With terminal box IC.PD.200.2A.02 6

Accessories: Cable plug Application Code number GDM 20 (grey) cable plug according to DIN 43650-A PG 042N056 ø Universal electronic multi-timer, type ETM ø Application External adjustable timing from to 45 minutes with to 5 seconds drain open. With manual override (test button). Electrical connection DIN 43650 A / EN 75 30-803-A y Outside adjustments y Light weight and small size y External adjustable timing from minute to 45 minutes with to 5 seconds drain open y One solid state timer fits all coil voltages from 24 240 V AC Voltage [V AC] To use with coil Ambient temperature [ C] Code number 24 240. BA, BD, BB -0 50 042N085 y Light diodes for indication y All in one unit y Manual override (test button) Technical data Type ET 20 M Voltage 24 240 V AC / 50 60 Hz. Power rating Max. 20 Watt Enclosure IP00, IP65 with power connector (cable plug) Electrical connection DIN connector ( DIN 43650-A) Ambient operating temperature range -0 50 C Function Start with pulse Interval timer 45 min. On timer 5 sec. Weight 0.084 kg Dimensions RĘCZNE STEROWANIE ZEWNĘTRZNE MOC WŁ Secuencia de control IC.PD.200.2A.02 7

Mounting bracket Description Brackets Code number 032U040 For EV20B.5 4.5B in connection with synthetic tubes, pipes and similar. Isolating diaphragm kit for EV20B.5 4.5 NC Seal material Code number 042U009 042U00 Avoids build-up of contaminates that can block movement of the armature. Permits use of more aggressive media that would normally attack the armature. Gel filled; guarantees operation after long periods of inactivity. The kit is suitable for orifice sizes up to DN 4.5 mm. The kit consist of: Assembled isolating unit O-ring 4 screws Locking button Nut for coil Spare parts kit, NC Valve type Seal material Code number EV20B.5, 2, 3, 4.5 032U2003 EV20B 6, 8, 0 EV20B 5 EV20B 20 EV20B 25 032U20 032U2006 032U202 032U203 032U204 032U207 032U208 032U209 The spare parts kit consists of: Locking button Nut for the coil Armature with valve plate and spring O-ring Spare parts kit, NO Valve type Seal material Code number EV20B.5, 2, 3, 4.5 032U2004 032U2005 The spare parts kit consists of: Armature tube 2 O-rings IC.PD.200.2A.02 8

Function NC Coil voltage disconnected (closed): When the voltage to the coil (5) is disconnected, the armature (2) with the valve plate (3) is pressed down against the valve orifice (4) by the closing spring () and the medium, s pressure. The valve will be closed for as long as the voltage to the coil is disconnected. Coil voltage connected (open): When voltage is applied to the coil(5), the armature (2) with the valve plate (3) is lifted clear of the valve orifice (4). The valve is now open for unimpeded flow and will be open for as long as there is voltage to the coil..closing spring 2.Armature 3.Valve plate 4.Valve orifice 5.Coil Function NO Coil voltage connected (open): When the voltage to the coil(8) is disconnected, the valve orifice (5) is open, the opening spring (2) lifting the spindle (3) with the valve plate (4) clear of the orifice. The valve will be open for as long as the supply voltage to the coil is disconnected. Coil voltage disconnected (closed): When voltage is applied to the coil (8), the magnetic field draws the valve, s armature () down to touch the fixed base(7). The spindle (3) with the valve plate (4) is now pressed down against the valve orifice (5) by the closing spring (6). The valve will be closed for as long as there is voltage to the coil..armature 2.Opening spring 3.Spindle 4.Valve plate 5.Valve orifice 6.Closing spring 7.Fixed base 8.Coil IC.PD.200.2A.02 9

Capacity diagrams: Example, water at low pressure: Capacity for EV20B.5B at differential pressure of 0 mbar. Approx. 0.08 l/min Example, water at higher pressure: Capacity for EV20B 3B at differential pressure of 0.5 bar. Approx. 0.2 m 3 /h IC.PD.200.2A.02 0

Example, air at lower pressure: Capacity for EV20B 5B at differential pressure of 7 mbar. Approx. 0 Nm 3 /h Example, air at higher pressure : Capacity for EV20B 2B at inlet pressure (p) of 5 bar and outlet pressure (p2) of 3.25 bar. Approx. 9 Nm 3 /h IC.PD.200.2A.02