CHLORINE, TOTAL (0 to 4.00 mg/l)

Similar documents
Chlorine, Free and Total, High Range

DPD Test N Tube Method *

Chlorine, Free and Total, High Range

CHLORINE, FREE, Ultra-high Range ( mg/l Cl 2 ) Method 10069

Chlorine, Free and Total, Low Range

Chlorine, Total. USEPA DPD Method 1 Method to mg/l as Cl 2 Chemkey Reagents. Test preparation. Before starting.

DR/4000 PROCEDURE NITRATE. 2. The display will show:

Peracetic Acid (PAA) and Hydrogen Peroxide (H 2 O 2 )

Cadmium Reduction Method (Using Powder Pillows or AccuVac Ampuls)

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

Cadmium Reduction Method Method to 0.50 mg/l NO 3 N (LR) Powder Pillows

Chloramine (Mono) and Nitrogen, Free Ammonia

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Cadmium Reduction Method Method 8171 MR (0.1 to 10.0 mg/l NO 3

Method to 0.50 mg/l NH 3 N Powder Pillows

NITROGEN, AMMONIA, High Range, Test N Tube

Sulfide DOC Methylene Blue Method 1 (0 0.70, and mg/l) Method Test procedure

Nitrogen, Ammonia. Test Preparation. Powder Pillows Method Method 8155 Salicylate Method 1 Powder Pillows

Method to 0.50 mg/l NH 3 N Powder Pillows

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Nitrogen, Total Inorganic

Chromium, Total. Alkaline Hypobromite Oxidation Method 1 Method to 0.70 mg/l Cr (spectrophotometers) 0.01 to 0.60 mg/l Cr (colorimeters)

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR The fill line is to the right.

Chromotropic Acid Method Method to 30.0 mg/l NO 3 N (HR) Test N Tube Vials

SILICA, Low Range (0 to 1.60 mg/l)

Method (0.04 to 4.50 mg/l Cl 2 ) Powder Pillows

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

DR/4000 PROCEDURE. IRON, Total

Phosphorus, Total. USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method to 3.50 mg/l PO. Test preparation

1,5-Diphenylcarbohydrazide Method* Powder Pillows or AccuVac Ampuls (0 to mg/l Cr 6+ )

Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters)

Mercaptoacetic Acid Method*

Phenolphthalein and Total Alkalinity Method to 4000 mg/l as CaCO 3 Digital Titrator

DR/4000 PROCEDURE SELENIUM. 4. Measure 100 ml of sample into a second 500-mL erlenmeyer flask (label the flask sample ).

DR/4000 QUATERNARY AMMONIUM COMPOUNDS PROCEDURE. 2. The display will show: 3. Fill a sample cell (the blank) with 25 ml of deionized water.

Method 8326 (0.006 to mg/l Al 3+ ) Powder Pillows

Powder Pillows 0.01 to 1.60 mg/l SiO 2 (LR, colorimeters)

Scope and application: For wastewater, seawater, drinking water, surface water and process water.

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

Persulfate Digestion Method Method to 40 mg/l N (HR) TNTplus 827

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 5000 DR The fill line is to the right.

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Mercuric Thiocyanate Method Method to 25.0 mg/l Cl Reagent Solution

Trihalomethane Formation Potential (THMFP)

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

NITRITE, Low Range (0 to mg/l NO 2- -N)

DR/4000 PROCEDURE LEAD. 2. The display will show: 3. Fill a 250-mL graduated cylinder to the 250-mL mark with sample.

Instrument Sample cell orientation Sample cell DR 6000 DR 3800 DR 2800 DR 2700 DR 1900 DR 5000 DR The fill line is to the right.

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Quaternary Ammonium Compounds

Dimethylphenol Method Method to mg/l NO 3 N or 1.00 to mg/l NO

PAR Method Method to 2.0 mg/l Pb TNTplus 850

PAR Method Method to 2.0 mg/l Pb TNTplus 850

Oxygen Demand, Chemical

Chromazurol S Method Method to 0.50 mg/l Al TNTplus 848

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

DR/4000 PROCEDURE CYANIDE. 1. Press the soft key under HACH PROGRAM. Select the stored program for cyanide by pressing 1750 with the numeric keys.

Cadion Method Method to 0.30 mg/l Cd TNTplus 852

DR/4000 PROCEDURE. HARDNESS, Total

Oxygen Demand, Chemical

Chlorphosphonazo Colorimetric Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Solution Pillow. Instrument Adapter Sample cell

NITROGEN, TOTAL, HR, Test N Tube

Understanding Chlorine Measurement. Rebecca Luedee Environmental Sales

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

TPH (Total Petroleum Hydrocarbons)

p-dimethylaminobenzaldehyde Method*

DR/4000 PROCEDURE MERCURY. Phase 1: Sample Digestion must be done in a fume hood! Toxic gases may be produced.

NITROGEN, TOTAL, Test N Tube * Method 10071

Manganese III Digestion Method * (with chloride removal)

Instruction Manual. Waterproof Portable Colorimeter C401 / 301 / 201 / 101 / 102 / 103 / 104 / 105. Part of Thermo Fisher Scientific

ALLOWAY METHOD OUTLINE

RAPID LIQUID TESTING. Hach Company, 1996 All rights reserved. Printed in the U.S.A dld/dp ed

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

Polychlorinated Biphenyls (PCB) in Soil

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample.

MERCURY (0.1 to 2.5 µg/l) Method 10065

SIDE BY SIDE COMPARISON TABLE FOR HACH METHOD NUMBER COLORIMETRIC DETERMINATION OF CYANIDE

LOW-RANGE TOTAL CHLORINE

#18 Analysis of Water (Chlorine, Phosphorus, Fluoride, and Color)

SMART Spectro. L Mott TEST INSTRUCTIONS. v MN. Spectro pho to m eter

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

Water quality Determination of free chlorine and total chlorine. Part 2: Colorimetric method using N,Ndialkyl-1,4-phenylenediamine,

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

Parameter Method Range # of Tests Code Page. Acidity (as % Oleic acid) titration % acidity 6 HI

Ammonia Gas Sensing Combination Electrode

Name Period Date. Lab 9: Analysis of Commercial Bleach

Dissolved Oxygen. Water Quality Test Kit Instruction Manual Code 7414/5860

Ammonia Gas Sensing Combination Electrode

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

L Mott SALT WATER AQUACULTURE. Model AQ-4/AQ-5 Code / test kit instruction manual

Safety Note: Safety glasses and laboratory coats are required when performing this experiment

Analysis of Free Ammonia in Chloramination Applications Using Lab Method and the APA6000

RAPID KJELDAHL BENCHNOTES

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

SC400 Colorimeter. Silica. Photometer-System. Instruction Manual. SiO 2. Bedienungsanleitung Seite Instruction Manual Page 19 33

Transcription:

CHLORINE, TOTAL (0 to 4.00 mg/l) DOC316.53.01261 For water, wastewater, and seawater Method 10250 DPD Method Powder Pillows USEPA accepted for reporting water and wastewater analyses * Note: This product has not been evaluated to test for chlorine and chloramines in medical applications in the United States. Using Powder Pillows 1. Enter the stored program number for total chlorine (Cl 2 ) powder pillows. Press: PRGM The display will show: PRGM? Note: For most accurate results, perform a Reagent Blank Correction using deionized water. 2. Press: 114 ENTER The display will show mg/l, Cl2 and the ZERO icon. 3. Fill a sample cell with 10 ml of sample (the blank). Note: Samples must be analyzed immediately and cannot be preserved for later analysis. 4. Place the blank into the cell holder. Tightly cover the sample cell with the instrument cap. * Procedure is equivalent to USEPA method 330.5 for wastewater and Standard Method 4500-Cl G for drinking water. 1

5. Press: ZERO The cursor will move to the right, then the display will show: 0.00 mg/l Cl2 Note: If Reagent Blank Correction is on, the display may flash limit. 6. Fill a second cell to the 10-mL mark with sample. 7. Add the contents of one DPD Total Chlorine Powder Pillow for 25-mL samples to the sample cell (the prepared sample). Cap and swirl the sample cell vigorously to dissolve the powder. Note: It is not necessary that all the powder dissolves. 8. Press: TIMER ENTER A three-minute reaction period will begin. A pink color will develop if chlorine is present. 9. After the timer beeps, place the prepared sample into the cell holder. Tightly cover the sample cell with the instrument cap. 10. Press: READ The cursor will move to the right, then the result in mg/l total chlorine will be displayed. Note: It the sample temporarily turns yellow after sample addition, or the display flashes limit, it is due to high chlorine levels. Dilute a fresh sample and repeat the test. A slight loss of chlorine may occur during dilution. Multiply the result by the dilution factor. Or use the High Range Total Chlorine test, program #8. Note: Standard Adjust may be performed using a prepared standard. Page 2 of 8

Sampling and Storage Analyze samples for chlorine immediately after collection. Chlorine is a strong oxidizing agent, and it is unstable in natural waters. It reacts rapidly with various inorganic compounds and more slowly oxidizes organic compounds. Many factors, including reactant concentrations, sunlight, ph, temperature and salinity influence decomposition of chlorine in water. Avoid plastic containers since these may have a large chlorine demand. Pretreat glass sample containers to remove any chlorine demand by soaking in a dilute bleach solution (1 ml commercial bleach to l liter of deionized water) for at least 1 hour. Rinse thoroughly with deionized or distilled water. If sample containers are rinsed thoroughly with deionized or distilled water after use, only occasional pre-treatment is necessary. Do not use the same sample cells for free and total chlorine. If trace iodide from the total chlorine reagent is carried over into the free chlorine determination, monochloramine will interfere. It is best to use separate, dedicated sample cells for free and total chlorine determinations. A common error in testing for chlorine is introduced when a representative sample is not obtained. If sampling from a tap, let the water flow for at least 5 minutes to ensure a representative sample. Let the container overflow with the sample several times, then cap the sample containers so there is no headspace (air) above the sample. If sampling with a sample cell, rinse the cell several times with the sample, then carefully fill to the 10-mL mark. Perform the chlorine analysis immediately. Accuracy Check Standard Additions Method (using powder pillows) a) Snap the top off a LR Chlorine PourRite Ampule Standard Solution. b) Use a TenSette Pipet to add 0.1 ml of the standard to the reacted sample (this is the spiked sample). Swirl to mix. c) Re-zero the instrument using the original sample (the blank). d) Place the spiked sample into the cell holder and press READ. Record the results. Page 3 of 8

e) Calculate the concentration of mg/l chlorine added to the sample: 0.1( vol. standard added) Label value (mg/l Cl 2 ) mg/l Chlorine added = ----------------------------------------------------------------------------------------------------------------------------- 10.1( sample + standard volume ) f) The spiked sample result (step d) should reflect the analyzed sample result + the calculated mg/l Cl 2 added (step e). Method Performance In a single laboratory, using a standard solution of 1.50 mg/l chlorine and two lots of reagents with the instrument, a single operator obtained standard deviations of ±0.02 mg/l chlorine. Interferences Interfering Substance Acidity Alkalinity Bromine Chlorine Dioxide Chloramines, organic Interference Level and Treatment Greater than 150 mg/l CaCO 3. May not develop full color or color may fade instantly. Neutralize to ph 6-7 with 1 N sodium hydroxide. Determine amount to be added on separate sample aliquot, then add the same amount to the sample being tested. Correct for volume addition. Greater than 250 mg/l CaCO 3. May not develop full color or color may fade instantly. Neutralize to ph 6-7 with 1 N sulfuric acid. Determine amount to be added on separate sample aliquot, then add the same amount to the sample being tested. Correct for volume addition. Interferes at all levels Interferes at all levels May interfere Hardness No effect at less than 1,000 mg/l as CaCO 3 Iodine Interferes at all levels Manganese, Oxidized (Mn 4+, Mn 7+ ) or Chromium, Oxidized (Cr 6+ ) Ozone Peroxides Extreme sample ph and highly buffered samples 1. Adjust sample ph to 6-7. 2. Add 3 drops potassium iodide (30 g/l) to a 25-mL sample. 3. Mix and wait one minute. 4. Add 3 drops sodium arsenite (5 g/l) and mix. 5. Analyze 10 ml of the treated sample as described in the procedure. 6. Subtract the result from this test from the original analysis to obtain the correct chlorine concentration. Interferes at all levels May interfere Adjust to ph 6-7. Page 4 of 8

Summary of Method Chlorine can be present in water as free available chlorine and as combined available chlorine. Both forms can exist in the same water and be determined together as the total available chlorine. Free chlorine is present as hypochlorous acid and/or hypochlorite ion. Combined chlorine exists as monochloramine, dichloramine, nitrogen trichloride and other chloro derivatives. The combined chlorine oxidizes iodide in the reagent to iodine. The iodine reacts with DPD (N, N-diethyl-p-phenylenediamine) along with free chlorine present in the sample to form a pink color which is proportional to the total chlorine concentration. To determine the concentration of combined chlorine, run free chlorine and total chlorine tests. Subtract the results of the free chlorine test from the results of the total chlorine test to obtain combined chlorine. Pollution Prevention and Waste Management Samples treated with sodium arsenite for manganese or chromium interferences will be hazardous wastes as regulated by Federal RCRA for arsenic (D004). Refer to the appropriate Material Safety Data Sheet (MSDS) for more information on proper disposal of these materials. Instrument Setup The following procedure will add program 114 to a DR/820, DR/850 or DR/890 instrument. 1. Turn on the instrument by pressing the ON key. 2. Press the SETUP key. 3. Press the DOWN arrow key until the prompt line shows USER. 4. Press the ENTER key. 5. Enter 8138, followed by ENTER. Note: The arrow keys can be used to scroll and review or change numbers at any time. 6. Refer to the following table and enter the number from the Enter column that corresponds to line number 1 on the display. Press ENTER. Repeat for lines 2 56 on the display. Page 5 of 8

Line Number Enter Line Number Enter 1 114 29 0 2 24 30 0 3 74 31 0 4 0 32 0 5 0 33 0 6 0 34 0 7 0 35 0 8 0 36 0 9 0 37 0 10 0 38 0 11 0 39 0 12 63 40 0 13 219 41 0 14 34 42 0 15 200 43 1 16 0 44 164 17 0 45 0 18 0 46 4 19 0 47 10 20 67 48 0 21 108 49 180 22 50 50 0 23 0 51 0 24 0 52 0 25 0 53 0 26 0 54 223 27 0 55 0 28 0 56 255 Page 6 of 8

REQUIRED REAGENTS & APPARATUS (Using Powder Pillows) Description Qty/Test Unit Cat. No. DPD Total Chlorine Powder Pillows, 25 ml... 1 pillow...100/pkg...1406499 Sample Cell, 10-20-25 ml, w/caps...2...6/pkg...2401906 OPTIONAL REAGENTS Description Unit Cat. No. Chlorine Standard Solution, PourRite ampule, 25-30 mg/l Cl 2...20/pkg...26300-20 Potassium Iodide Solution, 30 g/l......100 ml * MDB...343-32 Sodium Arsenite, 5 g/l...... 100 ml* MDB...1047-32 Sodium Hydroxide Standard Solution, 1 N...... 100 ml* MDB...1045-32 Sulfuric Acid Standard Solution, 1 N...... 100 ml* MDB...1270-32 Water, deionized...... 4 L...272-56 OPTIONAL APPARATUS Description Unit Cat. No. PourRite Ampule Breaker...each...24846-00 Cylinder, graduated, 25 ml...each...508-40 ph Indicator Paper, 1 to 11 ph units...5 rolls/pkg...391-33 ph Meter, HQ30d, single-input, multi-parameter...each... HQ30D53000000 ph probe, standard gel, 1-m cable...each... PHC10101 Pipet, TenSette, 0.1 to 1.0 ml...each...19700-01 Pipet Tips, for 19700-01 TenSette Pipet... 50/pkg...21856-96 Pipet Tips, for 19700-01 TenSette Pipet... 1000/pkg...21856-28 For Technical Assistance, Price and Ordering In the U.S.A. Call 800-227-4224 Outside the U.S.A. Contact the Hach office or distributor serving you. * Marked Dropper Bottle - contact Hach for larger sizes. Page 7 of 8

FOR TECHNICAL ASSISTANCE, PRICE INFORMATION AND ORDERING: In the U.S.A. Call toll-free 800-227-4224 Outside the U.S.A. Contact the HACH office or distributor serving you. On the Worldwide Web www.hach.com; E-mail techhelp@hach.com HACH COMPANY WORLD HEADQUARTERS Telephone: (970) 669-3050 FAX: (970) 669-2932 Hach Company, 2013. All rights reserved. March 2013, Edition 2