Certificate of Analysis

Similar documents
Certificate of Analysis

Certificate of Analysis

CERTIFIED REFERENCE MATERIAL RRM Au014

CERTIFICATE OF ANALYSIS SARM 74 FERROCHROME METAL

Multi Analyte Custom Grade Solution. Calcium, Iron, Potassium,

Multi Analyte Custom Grade Solution. Aluminum, Potassium, Magnesium, ANALYTE CERTIFIED VALUE ANALYTE CERTIFIED VALUE

ANALYSIS CERTIFICATE OF

CERTIFICATE OF ANALYSIS

Worldwide Open Proficiency Test for X Ray Fluorescence Laboratories PTXRFIAEA13. Determination of Major, Minor and Trace Elements in a Clay Sample

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

Certified Reference Material

Certificate of Analysis

Inspection Documents for Type 2.1 Coverage:

Certified Reference Material

Certificate of Analysis

CERTIFICATE OF ANALYSIS

Inspection Documents for Type 2.1 Coverage:

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

CERTIFICATE OF ANALYSIS

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT#

METALS IN WATER BATCH: MATERIAL. Description. Cu, Ni and. Quantity 5% (V/V). Use. the mark in. such a way. water. The are given in QC METAL HL2

BATCH: MATERIAL. Description. water. Quantity QC METAL LL2. is prepared (V/V). Use. be used in the quality. nitric acid is. certificate. intended use.

ICP/MS Multi-Element Standards

Project Copper CBC. Bahia Brazil -August

Inspection Documents for Type 2.1 Coverage:

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3163 Lot Number:

ICP-OES Application Note Number 35

materials and their properties

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Inspection Documents for Type 2.1 Coverage:

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

CERTIFICATE OF. Single Analyte Custom Grade Solution g/ml (measured at 20 ± 4 ºC) Graviametric NIST SRM Lot Number: See Sec. 4.

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3103a Lot Number:

Current State of Extraction Don t Be Deceived! Sharon F. Webb, Ph.D. Director of Quality Program

Atomic Structure. Aprenda Chemistry proudly presents. Odd Answer. Flash Cards 1. Ba

Test Method: CPSC-CH-E

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

CERTIFICATE OF. Single Analyte Mass Spec Solution ± 0.1 µg/ml g/ml (measured at 20 ± 4 ºC)

REFERENCE MATERIALS

IAEA-TECDOC-9SO. Sampling, storage

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3112a Lot Number: Cr3

Geogenic versus Anthropogenic Metals and Metalloids

UTM coordinates, x and y X Y Percent Ownership 100

Single Analyte Custom Grade Solution ± 4 µg/ml g/ml (measured at 20 ± 1 ºC) Acidimetric NIST SRM 84L Lot Number: 84L

ANALYSIS CERTIFICATE OF 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Single Analyte Custom Grade Solution ± 4 µg/ml g/ml (measured at 20 ± 1 ºC) EDTA NIST SRM 928 Lot Number: 928

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Sodium Chloride - Analytical Standard

Inspection Documents for Type 2.1 Coverage:

Single Analyte Custom Grade Solution. CGWH2O1 M2-W H2O µg/ml ea: Tungsten Ammonium Metatungstate

Inspection Documents for Type 2.1 Coverage:

Hiroshi Sawai TKG Laboratory Center International Standardisation Office

Certification Report. Certified Reference Material. BAM-M383a, b, c. Pure Copper. January 2014 (revised March 2015)

February 20, Joe Cerniglia The International Group for Historic Aircraft Recovery (TIGHAR) Job Number: S0CHG688. Dear Joe:

Application of total reflection X-ray fluorescence spectrometry for trace elemental analysis of rainwater

Chapter 2 Atoms and the Periodic Table

Certificate of Analysis

Overview of X-Ray Fluorescence Analysis

Reporting Category 1: Matter and Energy

Trace Metal Dynamic Extraction from Five Pumps in Hydrochloric Acid. Submitted to: Reto Schoeb Levitronix GmbH. Submitted by:

Note that the protons and neutrons are each almost 2,000 times more massive than an electron; What is the approximate diameter of an atom?

Single Analyte Mass Spec Solution ± µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT# Calculated See Sec. 4.

Reporting Category 1: Matter and Energy

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Full file at

Single Analyte Custom Grade Solution. 999 ± 3 µg/ml g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3112a Lot Number:

ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Ambient Air Sampling Program Second Quarter 2015 Report Sudbury, Ontario. Submitted to:

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

OES - Optical Emission Spectrometer 2000

Using the Periodic Table

The Periodic Table of the Elements

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3122 Lot Number:

Chemical Behavior of Metals

CERTIFICATE OF ANALYSIS

7) Applications of Nuclear Radiation in Science and Technique (1) Analytical applications (Radiometric titration)

CERTIFICATE OF. Single Analyte Custom Grade Solution. ICP Assay NIST SRM 3120a Lot Number: Calculated NIST SRM Lot Number: See Sec. 4.

CERTIFICATE OF ANALYSIS

AMIS0153 Certified Reference Material. Certificate of Analysis

McCLELLAND LABORATORIES, INC Greg Street, Sparks, Nevada (775) FAX (775)

Chapter 3: Stoichiometry

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Reference Materials Update

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Chem GENERAL CHEMISTRY I MIDTERM EXAMINATION

S.K. Sahoo 1 *, Z.S. Zunic 2, R. Kritsananuwat 1, H. Arae 1 and S. Mishra 1

ANALYSIS CERTIFICATE OF 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

Single Analyte Mass Spec Solution ± 0.60 µg/ml g/ml (measured at 20 ± 1 ºC) METHOD NIST SRM# SRM LOT# Calculated See Sec. 4.

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3162a Lot Number:

1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION 3.0 CERTIFIED VALUES AND UNCERTAINTIES. Assay Information:

8. Relax and do well.

LAB REPORT ON XRF OF POTTERY SAMPLES By BIJOY KRISHNA HALDER Mohammad Arif Ishtiaque Shuvo Jie Hong

Name: SCH3U Worksheet-Trends

Single Analyte Custom Grade Solution g/ml (measured at 20 ± 1 ºC) ICP Assay NIST SRM 3165 Lot Number: EDTA NIST SRM 928 Lot Number: 928

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

Transcription:

Certificate of Analysis First issued: May 2014 Version: May 2014 PTC-1b Certified Reference Material for Nickel Copper Sulphide Concentrate with Noble Metals Analyte Units Mean Table 1 PTC-1b Certified Values Within-lab Betweenlabs 95% Confidence Interval of Mean Ag µg/g 53.1 1.6 2.2 1.0 As µg/g 222 8 29 17 Au a µg/g 1.99 0.11 0.18 0.12 Co % 0.3253 0.0055 0.0082 0.0038 Cu classical b % 7.919 0.025 0.056 0.033 Cu instrumental c % 7.97 0.09 0.17 0.07 Fe % 36.78 0.45 0.67 0.28 moisture d % 0.81 0.03 0.10 0.07 Mg no AD2,3 e % 0.441 0.008 0.027 0.014 Ni classical f % 11.256 0.036 0.092 0.059 Ni instrumental c % 11.29 0.16 0.21 0.10 Pb % 0.0795 0.0014 0.0029 0.0015 Pd a µg/g 9.46 0.24 0.25 0.20 Pt a µg/g 6.47 0.24 0.44 0.29 S g % 29.95 0.24 0.64 0.27 Si h % 2.468 0.055 0.065 0.044 Zn % 0.2083 0.0044 0.0063 0.0038 cont d

Table 1 PTC-1b Certified Values cont d a most sets involve some type of fire assay pre-concentration b the data includes sets using titration and electrogravimetric methods c the data includes sets using instrumental techniques such as atomic absorption spectrometry, inductively coupled plasma - optical emission spectrometry, inductively coupled plasma mass spectrometry, X-ray fluorescence, and, for copper only, instrumental neutron activation analysis d samples of 1 to 10 grams were dried for 1 to 60 hours at 100 to 110 C e sets using digestion by two acids (hydrochloric and nitric) or three acids (hydrochloric, nitric and hydrofluoric) were excluded as method outliers based on statistical tests f the data includes sets using titration, electrogravimetric and dimethylglyoxime methods g digestion using four acids (hydrochloric, nitric, hydrofluoric and perchloric), various fusion and combustion methods were used h all sets used a fusion for the preparation Analyte Units Mean Table 2 PTC-1b Provisional Values Within-lab Between-labs 95% Confidence Interval of Mean Al a % 0.7518 0.0059 0.0059 0.0048 Ba a, b µg/g 61.5 2.0 2.0 2.3 Ca c % 0.571 0.017 0.083 0.044 Mn no AD2, 3 d % 0.0193 0.0003 0.0021 0.0018 loss on ignition e % 13.44 0.13 0.49 0.38 Se a, b µg/g 120 4 10 11 Ti a % 0.0696 0.0023 0.0047 0.0041 a digestion using four acids (hydrochloric, nitric, hydrofluoric and perchloric), fusions and instrumental neutron activation analysis were used b statistical analysis of the data warrants classification as provisional despite only 6 sets of data c the only set using digestion by two acids (hydrochloric and nitric) was excluded as a statistical outlier d sets using digestion by two acids or three acids (hydrochloric, nitric and hydrofluoric) were excluded as method outliers based on statistical tests e samples of 0.5 to 2 grams were ignited for 1 to 30 hours at 1000 to 1050 C PTC-1b May 2014 Page 2 of 5

Table 3 PTC-1b Informational Values (semi-quantitative only) No. accepted laboratories Element Units Mean / values Element Units Mean No. accepted laboratories / values Cd µg/g 38 7 / 29 Sb b µg/g 6 3 / 11 Cr a % 0.004 6 / 30 Sn b µg/g 120 3 / 13 Ir µg/g 0.2 3 / 15 Sr b µg/g 30 4 / 14 K b % 0.15 5 / 23 Te b µg/g 30 3 / 11 Mo c µg/g 11 4 / 16 V b µg/g 20 4 / 18 Na b % 0.17 6 / 28 Y b µg/g 3 3 / 11 Rh d µg/g 0.5 3 / 15 a microwave digestion with two acids (hydrochloric and nitric), digestion with four acids (hydrochloric, nitric, hydrofluoric and perchloric) and instrumental neutron activation analysis were used b digestion using four acids, fusions and instrumental neutron activation analysis were used c digestion with three (hydrochloric, nitric and hydrofluoric) or four acids and fusion were used d fire assay pre-concentration was used for all sets SOURCE PTC-1b is a nickel-copper sulphide concentrate with noble metals donated by Vale from its Clarabelle mill in Copper Cliff, Ontario, Canada. This is the same source as its predecessor, PTC-1a. DESCRIPTION The mineral species include: pentlandite (34.7%), chalcopyrite (23.2%), pyrrhotite (22.4%), pyrite (5.6%), anorthoclase (4.9%), Fe-Si-S-O (possibly danalite, 3.6%), Fe-Ni alloy (1.0%), bravoite (0.8%), magnetite (0.6%), biotite and clinochlore (both at 0.5%), gypsum, millerite and quartz (all at 0.4%), other and sphalerite (both at 0.2%), ilmenite (0.1%). INTENDED USE PTC-1b is suitable for the analysis of nickel, copper, gold, platinum and palladium and other elements in concentrates in concentrations ranging from major, minor to trace levels. Examples of intended use include quality control and method development. INSTRUCTIONS FOR USE PTC-1b should be used as is, without drying. The contents of the bottle should be thoroughly mixed before taking samples. The contents of the bottle should be exposed to air for the shortest time possible. Unused material should be stored under an inert gas in a desiccator, or in a new, heat-sealed laminated foil pouch. The values herein pertain to the material when produced. CanmetMINING is not responsible for changes occurring after shipment. HANDLING INSTRUCTIONS Normal safety precautions for handling fine particulate matter are suggested, such as the use of safety glasses, breathing protection, gloves and a laboratory coat. PTC-1b May 2014 Page 3 of 5

METHOD OF PREPARATION The raw material was dried at 32 C and sieved to remove the plus 75 µm fraction. The recovery of the minus 75 µm fraction from the dried material was 61%. The product was blended, and then bottled in 200- gram units. Each bottle was purged with nitrogen and sealed in a laminated polyethylene - foil pouch to prevent oxidation. This is the only size that is available. HOMOGENEITY The homogeneity of the stock was investigated using fifteen bottles chosen according to a stratified random sampling scheme. Three subsamples were analyzed from each bottle. Nickel was determined in subsamples of 1 gram by acid digestion, separation using dimethylglyoxime, and electroplating with correction for co-plating elements. Copper was determined in subsamples of 1 gram by acid digestion and electroplating with correction for co-plating elements. Gold, platinum and palladium were determined in subsamples of 5 grams using fire assay pre-concentration followed by determination using inductively coupled plasma optical emission spectrometry. An additional three subsamples were taken from each of the 15 randomly chosen bottles. Subsamples of 0.25 grams were digested using hydrochloric, nitric, hydrofluoric and perchloric acids, and analyzed by inductively coupled plasma optical emission spectrometry for cobalt, and inductively coupled plasma mass spectrometry for lead. Samples of 0.1 grams were digested with hydrochloric and nitric acids in a microwave and analyzed by inductively coupled plasma mass spectrometry for arsenic. Samples of 0.1 grams were analyzed for sulphur using a combustion apparatus with infrared detection. Use of a smaller subsample than specified above will invalidate the use of the certified values and associated parameters. A one way analysis of variance technique (ANOVA) 1 or statistical analyses were used to assess the homogeneity of these elements. No significant between-bottle variation was observed for all elements. CERTIFIED VALUES Twenty-six industrial, commercial and government laboratories participated in an interlaboratory measurement program using methods of their own choice. Classical methods for nickel included titration, dimethylglyoxime and electrogravimetric methods. Classical methods for copper included titration with thiosulphate, other titration methods and electrogravimetric methods. Gold, platinum and palladium were determined by various fire assay pre-concentration methods including both nickel sulphide collection and lead button collection followed by determination using inductively coupled plasma optical emission spectrometry and inductively coupled plasma mass spectrometry. Methods for the determination of the elements included digestion with various combinations of acids with and without the addition of bromine on a hot plate or in a microwave oven and various types of fusions followed by the determination using atomic absorption spectrometry, inductively coupled plasma optical emission spectroscopy and inductively coupled plasma mass spectrometry. X-ray fluorescence on a fused pellet and instrumental neutron activation were also used for many elements. The concentration of sulphur was determined using combustion followed by infrared spectrometry, gravimetric analysis, various acid digestions and fusions followed by inductively coupled plasma optical emission spectroscopy and X-ray fluorescence. ANOVA was used to calculate the consensus values and other statistical parameters from the interlaboratory measurement program. Values are deemed to be certified if derived from 10 or more sets of data that meet CCRMP s statistical criterion regarding the agreement of the results. Seventeen analytes were certified (see Table 1). Full details of all work, including the statistical analyses, the methods and the names of the participating laboratories are contained in the Certification Report. For more details on how to use reference material data to assess laboratory results, users are directed to ISO Guide 33:2000, pages 14-17, and the publication, Assessment of laboratory proficiency using CCRMP reference materials, at www.cccrmp.ca. PTC-1b May 2014 Page 4 of 5

UNCERTIFIED VALUES Seven provisional values (Table 2) were derived from 8 or 9 sets of data that fulfill the CCRMP statistical criterion regarding agreement; or 10 or more sets of data, that do not fulfill the CCRMP statistical criteria required for certification; or 6 sets of data for which the statistical analysis of the data warranted provisional status. This latter group includes barium and selenium. Informational values for 13 elements, shown in Table 3, were derived from the means of a minimum of 3 sets of data. TRACEABILITY The values quoted herein are based on the consensus values derived from the statistical analysis of the data from the interlaboratory measurement program, and the standards used by the individual laboratories. The report gives the available details. CERTIFICATION HISTORY PTC-1b was released as a new material in May 2014. PERIOD OF VALIDITY The certified values are valid until May 31, 2034. The stability of the material will be monitored every two years for the duration of the inventory. Updates will be published on the CCRMP web site. LEGAL NOTICE CanmetMINING has prepared this reference material and statistically evaluated the analytical data of the interlaboratory measurement program to the best of its ability. The purchaser, by receipt hereof, releases and indemnifies CanmetMINING from and against all liability and costs arising out of the use of this material and information. CERTIFYING OFFICERS Maureen E. Leaver CCRMP Coordinator Joseph Salley Data Processor FOR FURTHER INFORMATION The Certification Report is available free of charge upon request to: CCRMP CanmetMINING (NRCan) 555 Booth Street, room 433 Ottawa, Ontario, Canada K1A 0G1 Telephone: (613) 995-4738 Facsimile: (613) 943-0573 E-mail: ccrmp@nrcan.gc.ca REFERENCES 1. Brownlee, K.A., Statistical Theory and Methodology in Science and Engineering; John-Wiley and Sons, Inc.; New York; 1960. PTC-1b May 2014 Page 5 of 5