Sodium Chloride - Analytical Standard

Similar documents
Sodium Chloride - Analytical Standard

Sodium Chloride - Analytical Standard

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

BATTERY INDUSTRY STANDARD ANALYTICAL METHOD

DRAFT EAST AFRICAN STANDARD

Mercury, total-in-sediment, atomic absorption spectrophotometry, nameless, direct

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Determination of Orthophosphate Ion

Determination of Nutrients. Determination of total phosphorus. Extraktion with aqua regia, reflux method. Introduction

Title Revision No date DETERMINATION OF HEAVY METALS (ARSENIC, CADMIUM, LEAD AND MERCURY) IN COSMETIC PRODUCTS

Corn Syrup Analysis E-51-1 PHOSPHORUS

National standard of People s Republic of China

Determination of Orthophosphate Ion

National standard of People s Republic of China

Spectrophotometric Determination of Ferrocyanide in Effluents

Carbonate content. SCAN-N 32:98 Revised White, green and black liquors and burnt lime sludge

Brooklyn College Department of Chemistry

Cadmium and lead content

Annex 2 Formaldehyde

Test Method: CPSC-CH-E

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

ASCORBIC ACID METHOD FOR PHOSPHORUS DETERMINATION

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

Nitrogen, ammonia, colorimetry, salicylate-hypochlorite, automated-segmented flow

METHOD 9200 NITRATE. 1.2 The applicable range of concentration is 0.1 to 2 mg NO -N per liter. 3 of sample.

Direct Determination of Aluminium in Milk by Graphite Furnace Atomic Absorption Spectrometry

Method for estimation of iodine in urine

EXPERIMENT 7. Determination of Sodium by Flame Atomic-Emission Spectroscopy

Experiment 7A ANALYSIS OF BRASS

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

METHOD 3010A ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS FOR TOTAL METALS FOR ANALYSIS BY FLAA OR ICP SPECTROSCOPY

LEAD (Colorimetric) 2. Muffle Furnace: Equipped with pyrometer and capable of operating at controlled temperatures up to 500 C

National Research Council Institute for Ecosystem Study Verbania Pallanza - Italy

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

Experiment 7: ACID-BASE TITRATION: STANDARDIZATION OF A SOLUTION

GRAVIMETRIC ANALYSIS OF A CHLORIDE SALT. REFERENCES: Nelson, J., Chemistry: The Central Science, 3 rd edition, Prentice-Hall, 1985

Cyanide, colorimetric, pyridine-pyrazolone

EXPERIMENT NINE Part I - The Standardization of Thiosulfate Solutions

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

EXPERIMENT 8 POTENTIOMETRY: DIRECT-MEASUREMENT OPTION

CHEMISTRY HIGHER LEVEL

/TC TC WI. Date: /TC. Secretariat: Einführendes Element Haupt-Element Ergänzendes Element

The Fluorometric Determination of Acetylsalicylic Acid in an Aspirin Tablet

Soil Quality Monitoring in Estuarine Ecosystem. Sachin N Hegde Center for Ecological Science Indian Institute of Science

INTERNATIONAL STANDARD

Reference method for the determination of real alcoholic strength by volume of spirit drinks of viti-vinicultural origin: measurement by pycnometry

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

PHYSICAL SCIENCE 0652/5

CO-ORDINATED SCIENCES 0654/5

Flushing Out the Moles in Lab: The Reaction of Calcium Chloride with Carbonate Salts

Experimental Procedure. Lab 406

EXPT. 8 IODOMETRIC DETERMINATION OF AVAILABLE CHLORINE IN A SAMPLE OF BLEACHING POWDER

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

For Research Use Only

CHM 130 Acid-Base Titration Molarity of Acetic Acid in Vinegar

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

THE TEMPERATURE DEPENDENCE OF THE EQUILIBRIUM CONSTANT

PRACTICAL 3 ph AND BUFFERS

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Synthesis and Analysis of a Coordination Compound

Exercise 6: Determination of Hardness of Water

ASTM Designation: D Standard Test Method for Determination of Iodine Number of Activated Carbon

DR/4000 PROCEDURE. IRON, Total

CHEM Practice to be done before the lab. Experiment 9 Introduction to Volumetric Techniques II. Objectives

Starches and derived products Determination of sulfur dioxide content Acidimetric method and nephelometric method

Chemistry Determination of Mixed Acids

MERCAPTAN SULFUR IN GASOLINE & KEROSENE AVIATION TURBINE & DISTILLATE FUELS USING ASTM D3227

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

Mercaptan Sulfur in Gasoline and Kerosene Aviation Turbine and Distillate Fuels

Tetraphenylborate Method Method to 7.0 mg/l K Powder Pillows

RAPID KJELDAHL BENCHNOTES

Name: Date: AP Chemistry. Titrations - Volumetric Analysis. Steps for Solving Titration Problems

Experiment # 9 : Cation Analysis: Group ( I )

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

The Synthesis and Analysis of Aspirin

Calcimeter. Meet the difference. Manual. T E I

TRANS-NZOIA COUNTY JOINT EVALUATION EXAMINATION-2014 Kenya Certificate of Secondary Education

Experiment 7: Titration of an Antacid

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

Scientific Observations and Reaction Stoichiometry: The Qualitative Analysis and Chemical Reactivity of Five White Powders

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

TECHNICAL TEMEPHOS. 1. Specification. Full specification WHO/SIT/19.R4 Revised 10 December Description

Zinc Metal Determination Perkin Elmer Atomic Absorption Spectrometer AAnalyst Procedures

CALCIUM (EGTA-Titrimetric)

LACTIC ACID. The method is applicable to the determination of lactic acid and lactate salts (Note 2) in light or heavy steepwater.

Advanced Unit 7: Chemistry Practical Examination (SET A) Candidates must have: Scientific calculator Ruler

SOUTH AFRICAN NATIONAL STANDARD

INTERNATIONAL OLIVE COUNCIL

Standard Methods for the Examination of Water and Wastewater

Naming salts. Metal Acid Salt. Sodium hydroxide reacts with Hydrochloric acid to make Sodium chloride

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

DR/4000 PROCEDURE NITRATE. 2. The display will show:

Experimental techniques

Determination of Reducing Sugar Content: Clinitest, Benedict s Solution and the Rebelein Titration

Cadmium Reduction Method Method to 10.0 mg/l NO 3 N (MR, spectrophotometers) 0.2 to 5.0 mg/l NO 3 N (MR, colorimeters)

MBOONI WEST SUB - COUNTY JOINT EVALUATION TEST

Transcription:

Sodium Chloride - Analytical Standard Determination of Total Mercury Former numbering: ECSS/CN 312-1982 & ESPA/CN-E-106-1994

1. SCOPE AND FIELD OF APPLICATION The present EuSalt Analytical Standard describes a cold vapour atomic absorption spectrometric method for the determination of total mercury in sodium chloride. The method is applicable to products of mercury content (Hg) equal to or greater than 20 µg per kilogram of salt (see 8.6.). 2. PRINCIPLE Dissolution of the sample in a mixture of water, sodium chlorate and hydrochloric acid. Oxidation with the nascent chlorine, converting all forms of mercury to ionic mercury (II). Reduction of the excess of oxidant by hydroxylammonium chloride and of mercury (II) to atomic mercury by tin (II) chloride. Entrainment of the mercury in a stream of gas and measurement of the absorbance at a wavelength of 253.7 nm. 3. REAGENTS Unless otherwise stated, use only reagents of recognized analytical grade having the lowest possible mercury content and only distilled water or water of equivalent purity. Store all reagents in glass bottles. 3.1. Sodium chloride with a mercury content less than 20 µg/kg (check against water) 3.2. Hydrochloric acid, c (HCl) 6 mol/l (azeotropic mixture) Purify this solution as follows. Add 500 ml of water and 5 ml of sulphuric acid, ρ 1.84 g/ml, 96% (m/m), to 500 ml of hydrochloric acid ρ 1.19 g/ml, 37% (m/m). Distil the azeotropic mixture. 3.3. Sodium chlorate solution, β (NaClO3 ) 100 g/l 3.4. Potassium dichromate solution, β (K2 Cr 2 O 7 ) 4 g/l Dissolve 4 g of potassium dichromate in 500 ml of water. Add 500 ml of nitric acid, ρ 1.40 g/ml, 65% (m/m), and mix. 3.5. Tin(II) chloride solution, β (SnCl2. 2H2 0) 100 g/l Dissolve 25 g of tin (II) chloride dihydrate in 50 ml of warm hydrochloric acid, ρ 1.19 g/ml, 37% (m/m). Allow to cool and add 1-2 g of metallic tin. Dilute to 250 ml and mix. Prepare this solution just before use and slowly pass nitrogen through for 30 minutes to remove any mercury. Note: Prevent oxidation of solid tin (II) chloride by air. 3.6. Hydroxylammonium chloride solution, β (NH2 OH. HCl) 100 g/l 3.7. Mercury, stock solution I, β (Hg) = 1000 mg/l, commercial standard solution or to be prepared as follows. Dissolve 1.354 g of mercury (II) chloride (HgCl 2 ) in 50 ml of hydrochloric acid (3.2.) and add 50 ml of potassium dichromate solution (3.4.). Transfer into a 1000 ml onemark volumetric flask, dilute to the mark with water and mix. Store this solution in a cool, dark place and renew after two months. 3.8. Mercury, stock solution II, β (Hg) = 1 mg/l Prepare this solution just before use by successive dilutions of the stock solution I (3.7.). Add 50 ml of potassium dichromate solution (3.4.) for preparing 1000 ml of final solution.

3.9. Air or nitrogen Use a gas containing no mercury or other components capable of absorbing radiations at a wavelength of 253.7 nm. Any mercury present can be removed by a charcoal filter. 4. APPARATUS Usual laboratory equipment (see 8.2.) and an apparatus allowing the determination of mercury. An example of suitable apparatus is shown in the figure in the appendix. This applies to an open-circuit measuring system and includes principally the following: 4.1. Atomic absorption spectrometer 4.2. Mercury hollow cathode lamp or 4.3. Low-pressure mercury vapour lamp 4.4. Measuring cell, minimum path length 10 cm with windows transparent to radiation of 253.7 nm. 4.5. Reaction bottle Use, for example, a 100 ml gas washing bottle with sintered gas inlet or pointed immersion tube and 60 ml mark. Note: Fill the bottle with water when not in use. If different bottles are used, check that the results are identical. Traces of tin (IV) oxide which may have settled onto the walls have to be removed by hydrochloric acid, ρ 1.19 g/ml, 37% (m/m). 5. SAMPLING AND SAMPLES (see 8.1.) A test sample of about 500 g should be taken for analysis, ensuring it is representative of the whole batch. 6. PROCEDURE (see 8.1.) 6.1. Test portion Weigh, to the nearest 0.1 g, about 10 g of the test sample. 6.2. Test solution (see 8.3.) Transfer the test portion (6.1.) into a 100 ml conical flask and add 30 ml of water. 6.3. Blank solution Transfer 30 ml of water in a 100 ml conical flask. 6.4. Calibration solutions (see 8.4.) Dissolve in a series of six 100 ml conical flasks 10 g of sodium chloride (3.1.) in 30 ml of water and add the volumes of mercury stock solution II (3.8.) indicated in the following table: Calibration solution No. Hg, stock solution II ml Corresponding mass of mercury, µg 1(*) 0 0 2 0.5 0.5 3 1.0 1.0 4 1.5 1.5 5 2.0 2.0 6 3.0 3.0 (*) zero calibration solution 6.5. Determination 6.5.1. Mineralization Proceed as follows with the conical flasks prepared in (6.2.), (6.3.) and (6.4.).

Add some glass beads, 4 ml of hydrochloric acid (3.2.) and 3 ml of sodium chlorate solution (3.3.). Heat and keep boiling for 5 minutes. Allow to cool and transfer quantitatively into a 100 ml onemark volumetric flask. Dilute to the mark and mix. 6.5.2. Apparatus setting Equip the spectrometer (4.1.) with the mercury lamp (4.2.) or (4.3.). Set the lamp current, the slit and the flow of air or nitrogen according to the instruction manual of the instrument. Adjust the wavelength at the maximum of emission at about 253.7 nm. 6.5.3. Spectrometric measurements (see 8.5.) Proceed with the solutions prepared in (6.5.1.) in the following way. Transfer 10.0 ml of solution (6.5.1.) and 3.0 ml of hydroxylammonium chloride solution (3.6.) into the reaction bottle (4.5.). Fill to the mark (60 ml) with water, add 2 ml of tin (II) chloride solution (3.5.) and place the flask immediately into the device. Swirl to mix and allow to stand for a few minutes. Pass air or nitrogen through the reaction bottle and determine the maximum of absorbance. Stop the gas flow and remove the reaction bottle. Wash the bottle with potassium dichromate solution (3.4.) to oxidize any traces of tin (II) and rinse thoroughly with water. 6.5.4. Calibration curve Subtract the absorbance of the zero calibration solution from that of each other calibration solution (6.4.) and plot a graph with the masses of mercury (Hg), in micrograms, used to prepare the calibration solutions on the abscissa and the corresponding corrected absorbances on the ordinate. 7. EXPRESSION OF RESULTS 7.1. Evaluation The mercury content of the sample, ω (Hg), is given by the formula: where ω (Hg) ω (Hg) = 1000 x (m 1 - m 0 ) m is the total mercury content, in micrograms per kilogram of salt, m is the mass, in grams, of the test portion (6.1.), m 1 m 0 is the mass of mercury (Hg), in micrograms, analysed in the test solution (6.5.3.), is the mass of mercury (Hg), in micrograms, analysed in the blank solution (6.5.3.). 7.2. Repeatability and reproducibility Analyses, carried out on three samples by several laboratories, have given the following statistical results, each laboratory having furnished results obtained by the same operator performing two analyses per sample: Rock salt Vacuum salt Sea salt Number of laboratories 14 12 12 after elimination of outliers Results, µg Hg/kg salt Mean*) 6.2 3.3 4.6 Standard deviation for: - repeatability (s r ) 3.98 2.78 3.12 - reproducibility (s R ) 24.10 11.42 15.98 *) Mean values are below Limit of Quantitation

Reference: European Committee for the Study of Salt, ECSS/CN 287-1982, Statistical Study of Inter-Laboratory Analysis of Sodium Chloride (As, Cd, Hg, Pb) 8. REMARKS 8.1. Ensure that no trace of mercury is introduced during the sampling operations and during the analysis. 8.2. All new glassware used for this determination, including flasks used for reagents or samples should be washed as follows and thoroughly rinsed with water after each operation : with a brush and detergent if the walls are greasy with diluted nitric acid, c (HNO3 ) 7 mol/l. Check the glassware by carrying out several blank tests until satisfactory results are obtained before using it for actual determinations. Thereafter use such glassware for mercury determination only. 8.3. Test solutions described in ISO 2479 (Sodium chloride for industrial use - Determination of matter insoluble in water or in acid and preparation of principal solutions for other determinations) should not be used, as mercury losses may occur. 8.5. A maximum signal is obtained only under optimum conditions. For instance, the gas flow and the waiting time between tin (II) chloride addition and start of stripping have great influence on the peak height. A typical waiting time will be in the order of 5 minutes. Therefore those parameters have to be established experimentally for any individual apparatus and matrix. The maximum absorbance also depends very strongly upon the temperature of the solution during aeration (ΔA = 3% per C at room temperature). Therefore, all solutions have to be allowed to cool to about the same temperature (± 1 C). Test and blank solutions have to be analysed at the same time and with the same reagents. 8.6. The lower limit of determination, as stated here, can only be achieved if the procedure is carried out under optimum conditions: skilled operators experienced with this method, clean glassware, only used for such determination, optimum apparatus settings, very low mercury level of the ambient air, pure reagents. 8.4. To take into account the influence of sodium chloride on mercury evolution, a quantity of sodium chloride equal to the test portion (6.1.) should be taken for the preparation of calibration solutions. Samples of unknown composition should be tested for the presence of matrix effects, caused by components present other than sodium chloride, by the method of standard addition.

Page 6 of 6 Appendix Determination of mercury by atomic absorption spectrometry Typical apparatus A : atomic absorption spectrometer or mercury vapour meter B : mercury hollow cathode lamp or low-pressure mercury vapour lamp C : recorder or maximum deflection indicator D : measuring cell E : reaction bottle with sintered glass inlet or pointed immersion tube F : four-way stopcock G : flow control system (e.g. pressure regulator, needle valve and flow meter) H : absorption tube with charcoal I : absorption tube with drying agent