The optimum time of etching proved the Sensitivity of the CR-39 detector

Similar documents
ABSTRACT. Keywords: CR-39 Detector, chemical etching techniques, new etchant, Methanol. INTRODUCTION

INFLUENCE OF EXPOSURE GEOMETRY ON THE RESPONSE OF CR39 SSNT RADON DETECTORS *

Chemical etching characteristics for cellulose nitrate

Variation of Bulk Etch Rate and some other Etching Parameters with Etching Temperature for Cellulose Nitrate LR-115 Detector

Nuclear Instruments and Methods in Physics Research B 247 (2006)

Single-sheet identification method of heavy charged particles using solid state nuclear track detectors

BULK ETCH RATE MEASUREMENT OF CR-39 DETECTOR AT CONSTANT NORMALITY USING THE DIAMETERS AND THE LENGTHS OF THE TRACKS OF α-particles

On the response of LR-115 plastic track detector to tao Ne-ion. S M FARID Department of Physics, Rajshahi University, Rajshahi, Bangladesh

arxiv:physics/ v1 [physics.ins-det] 25 Oct 2006

Study of Radium and Radon Exhalation Rate in Some Sand Samples Using Solid State Nuclear Track Detectors

Etching Properties of Polyethyleneterephthalate (PET) Melinex-E Nuclear Track Detectors (NTDs)

CR-39 TRACK DETECTORS IN COLD FUSION EXPERIMENTS: REVIEW AND PERSPECTIVES. A. S. Roussetski

Chapter 2 MATERIALS, INSTRUMENTS AND TECHNIQUES

Theoretical basis for long-term measurements of equilibriumfactors using LR 115 detectors

New Calibrations and Time Stability. of the Response of the INTERCAST CR-39

Nuclear Instruments and Methods in Physics Research B

Study of CR-39 SSNDs irradiated with different types of radiation by FTIR spectroscopy and α-range determination

ion tracks in cellulose nitrate

Track Etch Detectors (TED)

Revista Mexicana de Física ISSN: X Sociedad Mexicana de Física A.C. México

Image Analysis of Cr-39 and Cn-85 Detector Irradiated by Thermal Neutron

Characterization of X-ray film base and overhead projector transparency as nuclear track detector

Track measurements of fast particle streams. from the pulse-discharge explosion-induced plasma. Ukraine

Sensitivity of LR 115 detectors in hemispherical chambers for radon measurements

Investigations of protons passing through the CR-39/PM-355 type of solid state nuclear track detectors

Tracks of MeV]u 4 Ar ions in Lexan polycarbonate detector

Formation and growth of tracks in nuclear track materials

11th Topical Seminar on Innovative Particle and Radiation Detectors 1-4/10/2008, Siena, Italy

Uncertainty in radon measurements with CR39 detector due to unknown deposition of Po

Fragmentation cross sections of 158 A GeV Pb ions in various targets measured with CR39 nuclear track detectors

DOSIMETRY ON THE FOTON M2/BIOPAN-5 SATELLITE

EXPERIMENT 11: NUCLEAR RADIATION

International Journal of PharmTech Research CODEN (USA): IJPRIF, ISSN: , ISSN(Online): Vol.9, No.9, pp , 2016

Plastics as nuclear track detectors for thermal neutron dosimetry

INVESTIGATIONS OF THE EFFECTS OF UV IRRADIATION ON THE ETCHING BEHAVIOR OF CR-39 SOLID STATE NUCLEAR TRACK TSE CHUN CHUN

A Simple Measurement Technique of the Equilibrium. Equivalent Thoron Concentration with a CR-39 Detector

Optical density for CN-85 and CR-39 Plastic Detectors and α-particle Radiography

COMPUTER SIMULATION OF THE PROCESSES IN A PAIR OF CR-39 TRACK DETECTORS DURING NEUTRON EXPOSURE

Nuclear reactions produced in an operating electrolysis cell. Abstract

Gamma Irradiation Effects on Track Properties of PADC-American Acrylics Track Detector

Assessment of Rn and U Concentrations in the Soil of Qadafery, Kalar and Zarayan Located in Sulaimani Governorate of Kurdistan Region- Iraq

Characteristics of the solid state nuclear detector CR-39 for neutron radiography purposes

Determination of Radon Gas Concentrations and Radon Exhalation Rate in Soil Sample in Selected Regions in Anbar Governorate

Lab NUC. Determination of Half-Life with a Geiger-Müller Counter

NUCLEAR EMISSIONS FROM TITANIUM HYDRIDE/DEUTERIDE INDUCED BY POWERFUL PICOSECOND LASER BEAM

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide:

Radioactivity III: Measurement of Half Life.

Determination of thorium and uranium contents in soil samples using SSNTD s passive method

RADON EQUILIBRIUM MEASUREMENT IN THE AIR *

Appendices towards the Operation Manual of Ultrasonic milk analyzer Lactoscan

Solid State Nuclear Track Detector (SSNTD) and its application

Digital imaging of charged particle track structures with a low-pressure optical time projection chamber

Effect of Etching Solution on Nuclear Track Detector CR-39

Dosimetry for space radiation in ISS lifescience experiments using PADLES system

Characterization of heavy charged particle fields using fluorescent nuclear track detectors

Atoms, Radiation, and Radiation Protection

2012 ANS WINTER MEETING NOVEMBER 11-15, 2012

Supplementary Information. Room-temperature fabrication of three-dimensional porous silicon

Kobe University Repository : Kernel

Dumpling-Like Nanocomplex of Foldable Janus Polymer Sheet and Sphere

The Fluorometric Determination of Acetylsalicylic Acid in an Aspirin Tablet

Keywords: Cape coast, concentration, E-PERM, exposure, LR-115, radon

Preliminary results of SI2 experiment obtained by PADC track etch detectors J. Szabó, J. K. Pálfalvi, B. Dudás

Fabrication and characterization of poly (ethylene oxide) templated nickel oxide nanofibers for dye degradation

The Reference Atomic Weight

LONG-TERM MEASUREMENTS OF RADON PROGENY CONCENTRATIONS WITH SOLID STATE NUCLEAR TRACK DETECTORS

Energetic Particles Generated in Earlier Pd + D Nuclear Reactions

Level of Radionuclide Contents in Surface Water from Shutt- Al-Arab River in Basrah Governorate, Iraq

Part 12- Physics Paper 1 Atomic Structure Application Questions Triple Science

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

Multilayer Nuclear Track Detectors for Retrospective Radon Dosimetry

Nuclear Tracks Morphology Study Using Raman Methodology

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

Calibration and applications of modern track detectors CR-39/PM-355 in nuclear physics and high temperature plasma experiments

Breakdown limit studies in high-rate gaseous detectors

Radon Activity And Exhalation Rate In Building Materials From Crushing Zone Of Shivalik Foothills In India

Influence of the Mechanical Sample Treatment on the Thermally Stimulated Exoelectron Emission in Aspect of the Application for Sample Dating

DETERMINATION OF URANIUM CONCENTRATION IN TEETH FEMALE SAMPLES USING FISSION TRACKS IN CR-39 FROM DIFFERENT COUNTRIES.

Nanopores with controlled profiles in track-etched membranes

arxiv: v2 [physics.ins-det] 7 Apr 2017

photo-mineralization of 2-propanol under visible light irradiation

Low Energy Generation of the "Strange" Radiation. Ivoilov N.G. Kazan State University, physical dept.,

Proton acceleration in thin foils with micro-structured surface

Elastic Recoil Detection Method using DT Neutrons for Hydrogen Isotope Analysis in Fusion Materials. Abstract

Experiment C-10 Titration of a Strong Acid and a Strong Base

An Analytical Approach is Developed to Estimate the Values of Range of Alpha Particles Emitted from Radon Gas

Chapter 16: Ionizing Radiation

electrons out of, or ionize, material in their paths as they pass. Such radiation is known as

Measurement of Radon and Uranium Concentrations and Background Gamma Rays at the University of Baghdad -Jadiriyah Site

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

Radiation and Radioactivity. PHYS 0219 Radiation and Radioactivity

PRODUCTS FOR EDUCATION AND TRAINING

Survey Meter OD-01 Address: Phone: Fax: URL:

Dosimetry. Sanja Dolanski Babić May, 2018.

Characterization of MEMS Devices

Measurement of Specific Activities of Some Biological Samples for Some Iraq Governorates

EXPERIMENTAL PROCEDURE

2015 Ph.D. Comprehensive Examination III. Radiological Sciences - Medical Physics

Physics of X-RAY Production

Chemical Etching Studies of a Brazilian Polycarbonate to Fast Neutron Detection

Transcription:

International Journal of Scientific & Engineering Research Volume 3, Issue 9, September-2012 1 The optimum time of etching proved the Sensitivity of the CR-39 detector Najeba F. Salih Mohamad S. Jaafar najebafarhad@yahoo.com msj@usm.my Radiation and Medical Physics, School of Physics, Universiti Sains Malaysia, Pulau, 11800USM Penang, Malaysia. Abstract: The ideal detector used in this study is the CR-39 polymer (Italy). A series of chemical etching experiments have been carried out on CR-39 detectors, irradiated with alpha particle. A alpha particle crossing a CR-39 sheet, leaves a trail of broken polymer links along its path (restricted to a microscopic cylindrical region). Experimental data has been analyzed to find out important track etch parameters. Both bulk etch rate and diameter of tracks are found to vary with time of etching and concentration of normality for NaOH, the average values for them are 1.190 µm/h and 1.172 µm/h, and 12.36 µm and 14.81µm, respectively. The critical angle of etching and track registration efficiency have also been determined using experimental data. All parameters depend on properties of incident ion and etching conditions. Results describing the dependence of track etch parameters on etching conditions have been presented. These results are useful in the interpretation of track data. Keywords: Alpha tracks, CR-39NTDs, Ion tracks, Bulk etch rate, Critical angle, Etching efficiency. ------------------- ------------------- INTRODUCTION detectors were discovered by Young, Silk and Barner and they have been widely used in science and technology [1]. The detection technique based on using track detectors is presently called solid state nuclear track detection (SSNTD)[2]. One of the most commonly detector used is CR-39NTD, because of its good sensitivity, stability against various environmental factors, and high degree of optical clarity [3]. The bulk etch-rate (V B ) is one of the basic parameters required for the use of the SSNTDs. The value of V B is required to be known many parameters such as track etch-rate, track efficiency and track diameters. Therefore, it is important to critically assess the methods of measuring V B [4]. Fast heavy ions can produce latent tracks in many dielectric materials, after adequate treatment, such as chemical etching [ 5].The operation of the solid state nuclear track detector (SSNTD) is based on the fact that a heavy charged particle will cause extensive ionization of the material when it passes through a medium. A recent review on SSNTDs has been given by Nikezic and Yu. If a piece of material containing the latent track is exposed to some chemically aggressive solution (such as NaOH or KOH solution), the chemical reaction would be more intensive in the latent track. Such a solution is called the etchant [1]. Through the etching, the latent track becomes visible as a particle track which may be seen under an optical microscope. Ion-track growth in SSNTDs has been Surface after time t

International Journal of Scientific & Engineering Research Volume 3, Issue 9, September-2012 2 suggested to base on two parameters, V T and V B as shown in Fig (1). Fig.(1): Progressive effects of etching track detector[7] V T is the track etch rate (the rate of etching along the particle trajectory) and V B is the bulk etch rate (the rate of etching of the undamaged detector surface) [8]. In other words, the bulk etch rate V B is the rate of removing of the undamaged surface of the detector. development is governed by the ratio V = V T /V B and track formation is not possible if V is smaller than or equal to 1 [1]. Research has been devoted to understanding the mechanisms of track growth in SSNTDs [9]. V B is influenced by many factors, such as the intrinsic characteristics of the plastic material, preparation method and the etching conditions in terms of temperature, concentration and type of etchant, etching duration, and stirring. V B has been measured by several experimental methods. Some have been based on the measurement of a parameter indirectly rated. In particular, direct methods for V B determination based on thickness-measurement before and after etching by measuring the thickness decreased of the detector during etching and based on mass-measurement is recording the mass of the detector before and after etching [4]. The indirect method is diameter measurement by measurement of the track diameter resulting after etching for specific time intervals [1]. a. Bulk etch rate (V B ) Bulk etch rate is one of the crucial factors controlling the track development in SSNTDs[10]. Due to Original the chemical surface reaction between the etching solution (etchant) and the detector material, some molecules of the detectors are removed. The final effect is the removal of the material from the detector surface and the thickness Latent ion track of the detector becomes smaller and smaller [1]. There are many equation to determining the bulk etch rate (V B ). V B (h) = h/2 t -----(1) where h is the difference layer removed during the etching time t. V B = m/2 t A ρ ----(2) where m is mass difference, A the etched surface area, ρ the density of the detector and t is the etching time. However, this method is limited by the accuracy of mass measurements. V B (m, h) = ( m)h 2 /2 t m 2 ---(3) V B = D /2 t ----(4) b. etch rate (V T ) The track etch rate (V T ), is the rate of etching along the particle trajectory[11]. A track is formed when V T > V B. and calculated by the relation V T =V B (4h 2 +D 2 )/ (4h 2 - D 2 ) ----(5) V T depends on the etching temperature [12].conical holes (etch tracks), are produced on the surface at the position of particle impacts (two different etching rates (V B and V T )), as shown in Fig.(1)[13] And all parameters determined by the following;

International Journal of Scientific & Engineering Research Volume 3, Issue 9, September-2012 3 V = V T /V B (6) D = 2h ---(7) V, the previous equation becomes D=2h =2V B t------(8) Where D is track diameter, h 2 is the thickness of the detector, m 2 is mass of the detector after etching[1]. L = V T t V B t ---(9)[14]. V= h/t----(10) From Eqs. (9) and (10), V can be found as: V=1+L/h------(11) c. The critical angle (θ c ) One of the geometrical limitations for the revelation of the etched tracks in SSNTDs is called critical angle (θ c ) [15], determined by Sin θ c = V B /V T or sin θ c = 1/ (V T /V B ), θ c = sin -1 (V B /V T ) ---- (12) d. Detector Efficiency (ƒ) Registration efficiency is very important parameter for any dosimeter and should be obtained before its use. The efficiency of each of the etchants was determined by using the values of V T and V B in a standard formula [16]. The partial sensitivities depend on the V function (V = V T /V B ) as well as the thickness of the removed active layer during etching and on a critical angle, can be obtained by the following equations ƒ = 1 (V B /V T ) ƒ = 1- V B /V T = 1-1/V ƒ = 1- sin θ c -----(13)[9] 2-Materials and Methodology a. CR-39NTD. CR-39NTD is a C 12 H 18 O 7 polymer with a density of 1.31 g/cm 3 [17]. The range of 5 MeV alpha particles in it is 28.77 µm. Gaillard et al [18] [19], had a thickness of 700 µm cut into pieces with an area of (1.0 1.5) cm 2 [6] [20], before use. The detectors used in the present study is the ideal detector, produced by Intercase Europe SRL (43100 Parma, Italy). The Intercast CR-39 has a low background for small etching process for its use in radon dosimetry [21]. The efficiency of CR-39NTDs changes with time of storage therefore, the calibration process is required before using it. CR- 39NTD was calibrated and its efficiency was 79.5%. The main characteristics of the detectors are listed in Table (1). The sensibility of CR-39 is physically able to register low energy alphas [21]. b. Irradiation systems Radium ( 226 Ra; activity 5µCi) was used as an alpha radiation source (for the irradiation of alpha particle). For controlling the final alpha energies incident on the detector distances in normal air the distance between the radium source and the detector surface has been determined at E α (0) is 5.49 MeV, the energy of alpha source and the source detector distances in air at normal temperature and pressure (NTP). The alpha particle range in the air is 4.08 cm. The range of alpha particle in air was changed by varying the source detector distance. Irradiation to the sources for 6 minutes irradiation at 2 hours interval was carried out [2]. c. Etching solution The sodium hydroxide aqueous solution (NaOH) of 6.25 mol per liter was used as the etching solution. The etching was done in a bottle with a tight lid to prevent change in the concentration of the etching solution due to vaporization of water and absorption of moisture. The etching process is performed in a

International Journal of Scientific & Engineering Research Volume 3, Issue 9, September-2012 4 thermostat bath which is electronically stabilized at 70 ºC. The chemical etching process involves 6.25M NaOH at 70 5 ºC, distilled water and a water bath- gotech testing machines inc modelgt-7039- M,220V, 50 Hz. was used for heating the etching (6.25N NaOH ) water solution at 70 ±0.5 Cº for 8h [2]. d. The bulk etch rates of the CR-39 in NaOH/ethanol The standard determination of V B is based on the measurement of the thickness of the detector after etching times and based on the determination of the mass of the detector after - before etching times. The thickness is measured with a digital micrometer of 1 ml accuracy in 10 positions on the detector foil and mass is weighted with an electric sensitive balance (Denver Instrument Company AA-200DS). The average bulk etch velocity was determined by using the above-mentioned values of V B. e. Irradiation and the etchings The CR-39 detectors used in the present study are the ideal detectors (Intercast Europe srl (Italy) [21]. Each piece of CR-39 NTD for this study was irradiated at constant irradiation time [22] with alpha particles. Each detectors was been irradiated at 1 msv/h with an 226 Ra source [23] ( activity of 5µCi). After irradiation, these detectors were etched in an aqueous solution of NaOH by two methods. In the first method, many detectors were etched in different concentrations of N of NaOH maintained at 70 ºC for 8 hours of etching. In the second method, other detectors were etched in different time of etching with 6.25N of NaOH maintained at 70 ºC by a water bath gotech testing machines inc modelgt-7039- M, 220 V, 50 Hz. The etchant was continuously stirred in order to assure its homogeneity, which suggested the necessity of stirring to avoid the build up of etching products at the surface of the samples affecting etching rate. After etching, The sample detector was then taken out from the etchant, washed for 20 min in running water in order to definitively stop the etching process and removing the NaOH present on the detectors surface the sample was then rinsed with distilled water. The detectors were dried in air completely and then used for analysis [24]. f. Counting System / scanning process of CR-39NTDs: After the chemical etching, equations (2 ) and (5) were employed to calculate the bulk etch-rate and track etch rate, for the thickness measurement, massmeasurement and diameter-measurement methods, respectively. The thickness and weight of each detector was measured before and after etching. The thickness removed layers were measured ( micrometer was used to measure the alpha induced track thickness removed layer) and the mass of detector was weighted (using an electronic balance having an accuracy of 0.1 mg. For the scanning process, etched tracks were observed using an optical microscope fitted with a magnification of (40-100)X. The microscope image was viewed using a high quality monochrome charge coupled device (CCD) TV camera. The track densities ρ (number of tracks per unit area) are then found. Optimum values of time of etching and concentration of normality NaOH were determined. V B, V T and etching efficiency and the critical angle were calculated using equations in described in Ref.[1]. Result and discussion The ideal detector used in this study is the CR- 39 polymer(italy). When an alpha particle crossing a cast CR-39 sheet, it leaves a trail of broken polymer links along its path (restricted to a microscopic cylindrical region). The CR-39 detectors irradiated

International Journal of Scientific & Engineering Research Volume 3, Issue 9, September-2012 5 with alpha particle from 226 Ra source were etched in normality NaOH /1-propanol solutions. Various concentrations and time of etching were used to achieve the optimum processing conditions. For comparison purposes, CR-39 detectors were also etched in conventional aqueous solution of NaOH at different concentrations at 70 ºC. After weighting the mass of detector, V B, V T and ƒ were determined using the Eqs.(2), (5) and (13) respectively as follows. a. In the bulk etch-rate using thickness-measurement method, the values of diameter (D) have been calculated according to Eq.(8). The average value of diameter (D) is (12.36 ± 0.012 ) µm when the irradiation time is fixed (5min) and the etching time is changeable at 6.25N NaOH with (70±0.5) ºC. When the optimum etching time is 8hours, the value of diameter at this value of optimum time of etching is (15.70 ±0.025) µm and the value of thickness at this time is (7.85 ±0.035) µm, as shown in Table (1). b. In the bulk etch-rate using mass-measurement method, the bulk etch-rate V B (M) is not a unique function of mass but depends up on either one or more the combination of other parameters namely, density of CR-39 is 1.31g/cm 3 [19], thickness is (700 µm ) [21], area of CR-39 is 1.5cm x1cm as appear in Eq.(2). The mass of the CR-39NTD was measured before and after etching. The average value of diameter is (11.98 ± 0.028 ) µm when the time irradiation is fixed 6min and the etching time is 8hours and the concentration of normality N of NaOH is changeable with (70±0.5) ºC. when the optimum etching time is 8hours, the values of diameter at the optimum time of etching is (15,68±0.025) µm and the thickness is (7.84±0.035) µm, shown in Table (1). The bulk etch-rate V B (M) was measured using the mass-measurement method in the first method, the average value of bulk etch-rate V B (M) is (1.190±0.091) µm/h when time of etching is changeable and the irradiation time is fixed at 6.25N NaOH with (70±0.5) ºC, but the value of bulk etch rate at the optimum time of etching is( 1.208±0.090) µm/h. In the second method the average value of bulk etch-rate V B (M) is (1.172±0.092) µm/h when the etching time is fixed and the concentration of normality N of NaOH is changeable with (70±0.5) ºC, and the value of bulk etch rate at the optimum time of etching is (1.224 ±0.090) µm/h. Both methods generate good values of V B. The value of V B in the first is (1.208±0.090) µm/h, however, is in agreement with 1.2 µm/h[19] for an etchant concentration of 6.25N at 70 ºC for 8 hours in Refs[21], [25] Two other, important parameters critical angle of etching, and track etching efficiency, have been evaluated using Eqs.(12) and (13). For the optimum time of etching at concentration 6 N at 70 ºC for 8hours. The critical angle of etching and track etching efficiency is 11.829 and %79.50, respectively. This is in agreement with Refs[21], [25]. The above suggested best etching conditions for CR-39 are useful for etching and for all samples. Fig(1) shows the relation for the removed layer with the time of etching, when the time of etching is increased the removed layer also increased (linearly). Fig(2) shows the relation of the diameter of track with the removed layer at 6.25N of NaOH concentration, when the removed layer increases, the diameter of track also increases (linearly). Fig(3) shows the change in bulk etch rate V B with normality of an aqueous solution of NaOH. When the concentration of normality is increased, the

The change of the thickness. diameter. International Journal of Scientific & Engineering Research Volume 3, Issue 9, September-2012 6 V B also increased but not linearly, therefore. Thus the first method of changing the etching time with fixed normality is much better and accurate. This method gave a good efficiency of %79.50 and approximates the real value of the detector efficiency of %80 used in this work and in agreement with the value in Refs.[25],[21]. Fig(4) shows the relationship for the efficiency of track with the time of etching at 6.25N of NaOH concentration and 70 ºC. When the time of etching increases, the efficiency of track increases until reaching 8hours then decreased, therefore the optimum time etching is 8hours. The relationship between track diameters and etching time is displayed in Fig. 3. The linear fitting of experimental data is described in Tables (1) and (2). x y = x + y = Etching time(h). Fig. 2. Evolution of the detector thickness as a function of the etching time (h). Removed layer. Fig.3. diameter versus removed layer for alpha particles at 6.25N NaOH concentration.

Etching efficiency Bulk Etch Rate(µm/h). International Journal of Scientific & Engineering Research Volume 3, Issue 9, September-2012 7 x + - x y = NormalitY (N). Fig. 4. The change of bulk etch rate with normality of an aqueous solution of NaOH. 6.25N NaOH at 70C o 79.50h Etching time(h) Fig. 5. Etching efficiency as a function of the etching time (h). Nu. Of detector Table 1: Values of V B,V, h, D, ƒ and ϴ c for alpha particles of various etching in CR-39NTD. Thickness removed layer diameter Change of mass (m gm) V B (µm/h) etch rate ratio V = V T /V B length-l Critical angle (ϴ c) Efficiency f % 1 8.62 17.24 0.00425 1.199 4.526 38.043 12.764 77.93 2 7.85 15.70 0.00380 1.208 4.878 37.472 11.829 79.50 3 6.75 13.50 0.00330 1.197 4.697 30.975 12.364 78.71 4 5.65 11.31 0.00281 1.185 4.427 24.366 13.055 77.40 5 4.64 9.28 0.00232 1.178 4.271 19.265 13.540 76.59 6 3.67 7.35 0.00185 1.174 4.161 14.844 13.905 75.97

International Journal of Scientific & Engineering Research Volume 3, Issue 9, September-2012 8 Nu. Of detector Table 2: Values of V B,V, h, D, ƒ and ϴ c for alpha particles of various concentration in normality Thickness removed layer diameter NaOH in CR-39NTD. Change of mass (m gm) V B (µm/h) etch rate ratio V = V T /V B length-l Critical angle (ϴ c) Efficiency f % 1 8.00 16.00 0.00425 1.259 4.411 34.352 13.000 77.37 2 7.84 15.68 0.00380 1.224 4.570 34.950 12.630 78.19 3 7.45 14.90 0.00330 1.170 4.456 32.340 12.960 77.56 4 7.24 14.48 0.00281 1.145 4.404 31.178 13.120 76.90 5 7.09 14,18 0.00232 1.138 4.087 28.104 14.160 75.50 6 6.83 13.66 0.00185 1.100 4.029 26.640 14.370 75.18 Acknowledgements The authors thank the Universiti Sains.Malaysia USM of Penang /Malaysia for the academic support of this paper References [1]. D. Nikezica, D., Yu, K.N., Materials Science and Engineering R 46, 51 123 (2004) [2]. B.C. Milenkovi, D. Nikezi, N. Stevanovi, Radiation Measurements-Elsevier. 45 (2010) [3]. G. H. Ahn, J.K. Lee, Nuclear Engineering Hanyang University (2005) [4]. F. Malik, et al. 2002Radiation Measurements- Pengamon 35 301 305 (2002) [5]. J.P.Y. Ho, C.W.Y Yip, et al., Radiation Measurements- Pergamum 36 155 159 (2003) [6]. D. Nikezica, K.N. Yu, Nova Science Publishers, INC (2007) [7]. S. Cecchini, Dipartimento difisica, Italy (2005) [8]. K. N.Yu, D. Nikezic, Nova Science Publishers, INC. (2009) [9]. N. F. Salih, (KAJ)Kurdistan Academicians Journal(2009) [10]. K. P. Eappen, Y. S. Mayya, Indian J. Phys. 83 (6) 751-757 (2009) [11]. F. Gordon, Nuclear Reactions (2006) [12]. S. Y. Y. Leung, et al., Applied Radiation and Isotopes 65, PP. 313-317 (2007) [13]. S. M. Farid, Nuclear Physics(1993) [14]. S. Cecchini, uclear Physics. Italy (2005) [15]. K.N Yu, et al., Radiation Measurements 40, 380 383 b (2005) [16]. S. A. Durrani, R. K. Bull, Vol 111, Pergamon (1987) [17]. E.U. Khana, et al., Radiation Measurements. 40 299 302. (2005) [18]. S. Gaillard, et al., 2007. 78, 013304 (2007) [19]. S. Cecchinia, et al., 101, I-40129 Bologna, Italy(2000) [20]. K. N. Yu, S. H. Cheng, Nuclear Instruments and Methods in Physics Research B (2009) [21]. J.K. SEK, et al., Bangladesh Journal, 2(1) 35.40 (2006) [22]. K.F. Chan, et al., Nuclear Instruments and Methods in Physics Research B 263, 284 289(2007) [23]. M. Dolleiser, S.R. H. Nezhad, Nuclear Instruments and Methods in Physics Research B 198, 98 107 (2002)D [24]. F. Leonardi, et al., National Institute for Occupational Safety and Prevention Rome, Italy (2002) d[25]. K. N. Yu, et al., Radiation Protection Dosimetry. Vol. 111, No. 1, pp. 93 96 (2004)OF THACHESCBRUN. HERMSDORF***,