Geoelectrical Investigations at Three Bridge Sites, North Nyala, Southern Darfour State, West-Sudan

Similar documents
RESISTIVITY IMAGING AND BOREHOLE INVESTIGATION OF THE BANTING AREA AQUIFER, SELANGOR, MALAYSIA. A.N. Ibrahim Z.Z.T. Harith M.N.M.

Index Terms- Apparent Resistivity, Aquifer, Geoelectric Section, Piezometric Surface.

Groundwater Sustainability at Wadi Al Bih Dam, Ras El Khaimah, United Arab Emirates (UAE) using Geophysical methods

The Use of Vertical Electrical Sounding (VES) for Subsurface Geophysical Investigation around Bomo Area, Kaduna State, Nigeria

Groundwater Assessment in Apapa Coast-Line Area of Lagos Using Electrical Resistivity Method

Vertical electrical sounding (VES) for subsurface geophysical investigation in Kanigiri area, Prakasam district, Andhra Pradesh, India

DELINEATION OF FRESH-BRACKISH WATER AND BRACKISH-SALINE WATER INTERFACES USING VES SOUNDINGS IN SHANI, BORNO STATE, NIGERIA

DETECTION OF GROUNDWATER POLLUTION USING RESISTIVITY IMAGING AT SERI PETALING LANDFILL, MALAYSIA

S.I. Fadele, M.Sc. 1 ; P.O. Sule, Ph.D. 1 ; and B.B.M. Dewu, Ph.D * ABSTRACT

DATA ACQUISITION METHODS FOR GROUNDWATER INVESTIGATION AND THE SITING OF WATER SUPPLY WELLS

Analysis of electrical resistivity data for the determination of aquifer depth at Sapele RD in Benin city

Relevance of 2D Electrical Imaging in Subsurface Mapping: Case Study of National Animal Production Research Institute (NAPRI), Zaria.

Application of Remote Sensing and Geo-Electrical Method for Groundwater Exploration in Khor Al Alabyad, North Kordofan State, Sudan

Elijah Adebowale Ayolabi, Ph.D. 1, Adetayo Femi Folorunso, M.Sc. 2*, Ayodele Franklin Eleyinmi, B.Sc. 1, and Esther O. Anuyah, B.Sc.

Scholars Research Library

Scholars Research Library. Geophysical investigation of effects of topographic complexities on groundwater potential in Ibusa, Delta State Nigeria

Ground Magnetic and Electrical Resistivity Mapping for Basement Structurs over Charnokitic Terrain in Ado-Ekiti Area, Southwestern Nigeria

Geoelectric Evaluation of Groundwater Potential: A Case Study of Sabongida-Ora and Environs, Southern Nigeria

Vertical Electrical Sounding Survey for Groundwater Exploration in Parts of Anyigba and its Environs, in the Anambra Basin of Nigeria

Geophysical Investigation of Foundation Condition of A Site in Ikere- Ekiti, Ekiti State, South-Western Nigeria

Geophysical Study of Limestone Attributes At Abudu Area of Edo State, Nigeria

INTEGRATED GEOPHYSICAL INVESTIGATION OF SEQUENCE OF DEPOSITION OF SEDIMENTARY STRATA IN ABAKALIKI, NIGERIA ABSTRACT

Integration of Seismic Refraction and 2D Electrical Resistivity in Locating Geological Contact

K. A. Murana, P. Sule, A.L. Ahmed, E.M. Abraham and E.G. Obande. 1. Introduction

Soils, Hydrogeology, and Aquifer Properties. Philip B. Bedient 2006 Rice University

SEISMIC REFRACTION INVESTIGATION OF THE SUBSURFACE STRUCTURE AT THE SOUTHERN PART OF NIGER STATE COLLEGE OF EDUCATION, MINNA, NIGERIA

EVALUATION OF AQUIFER CHARACTERISTICS FOR SELECTED NEW METHOD OF THE UM RUWABA FORMATION: NORTH KORDOFAN STATE, SUDAN

Groundwater Exploration using Integration of Electrical Resistivity Data with Remote Sensing and GIS Data, Northern State Sudan

EVALUATION OF GROUNDWATER POTENTIAL USING ELECTRICAL RESISTIVITY METHOD IN OKENUGBO AREA, AGO - IWOYE, SOUTHWESTERN, NIGERIA.

Use of VLF Electromagnetic and Electrical Resistivity Methods for Groundwater Investigation in Oke Amu Area, Southwestern Nigeria

Artificial Recharge to Alluvial Aquifer, Northeastern Nuba Mountains, Sudan.

Geophysical Investigation: A Case Study of Basement Complex, Nigeria

Geophysical Investigation of Ground Water Using Vertical Electrical Sounding and Seismic Refraction Methods

1-D Electrical Resistivity Survey For Groundwater In Ketu-Adie Owe, Ogun State, Nigeria.

Land subsidence due to groundwater withdrawal in Hanoi, Vietnam

Ministry of Minerals Geological Research Authority of Sudan (GRAS)

Determination of Thickness of Aquifer with Vertical Electrical Sounding

2-D RESISTIVITY IMAGING SURVEY FOR WATER-SUPPLY TUBE WELLS IN A BASEMENT COMPLEX: A CASE STUDY OF OOU CAMPUS, AGO-IWOYE SW NIGERIA

Morenikeji P. Anjorin, B.Tech. 1 and Martins O. Olorunfemi, Ph.D. 2*

2-D Resistivity Study: The Horizontal Resolution Improvement by Introducing the Enhancing Horizontal Resolution (EHR) Technique

Subsurface Characterization using Electrical Resistivity(Dipole-Dipole) method at Lagos State University (LASU) Foundation School, Badagry

The impact of geologic setting on the groundwater occurrence in the Eocene limestone of El Minia-East Nile-Egypt, using geoelectrical technique

FIG. 1 TOPOLOGY MAP SHOWING THE SURVEY AREA.

Accepted 15 December, 2012

APPLICATION OF ELECTRICAL RESISTIVITY TOMOGRAPHY FOR SAND UNDERWATER EXTRACTION

G. Barrocu G. Ranieri Faculty of Engineering, University of Cagliari, Italy. In the region of Muravera, south-east coast of Sardinia, the trend of

TWO DIMENSIONAL ELECTRICAL IMAGING OF THE SUBSURFACE STRUCTURE OF BOMO DAM ZARIA, KADUNA STATE NORTH CENTRAL NIGERIA

GEOTECHNICAL INVESTIGATION OF THE SUBSURFACE FORMATIONS, USING ELECTRICAL RESISTIVITY METHOD IN NORTHERN PART OF PAIKO TOWN, NIGER STATE, NIGERIA

The Preliminary Study of Meteorite Impact Crater at Bukit Bunuh, Lenggong

Delineation of Zones at Risk from Groundwater Inflows at an Underground Platinum Mine in South Africa

Geophysical Study of the Sedimentary Cover in Darb El-Arbeen, South Western Desert, Egypt

3D Electrical Resistivity Tomography (ERT) Survey of a Typical Basement Complex Terrain

A case study of crystalline limestone intrusion and fault zone identication using 2d eri technique in Ramco cements, pandalgudi mines, Tamilnadu

Electrical Resistivity Survey Forground Water At Eye Zheba Village, Off Bida - Minna Road

A Geophysical Investigation for Subsurface Characterization and Structural failure at the Site of a Building, Southwestern Nigeria

11/22/2010. Groundwater in Unconsolidated Deposits. Alluvial (fluvial) deposits. - consist of gravel, sand, silt and clay

B7 Applications of DC resistivity exploration

Case Study: University of Connecticut (UConn) Landfill

Electrical Resistivity Survey for Delineating Seawater Intrusion in a Coastal Aquifer

CONTENTS 1. INTRODUCTION. 2. THE D.C. RESISTIVITY METHOD 2.1 Equipment 2.2 Survey Procedure 2.3 Data Reduction

Application of Vertical Electrical Sounding (VES) In Delineating Ground Water Potential in Some Part of Jalingo, Taraba State North Eastern Nigeria

Impact of the Danube River on the groundwater dynamics in the Kozloduy Lowland

GEOELECTRICAL INVESTIGATION OF GROUNDWATER CONDITION IN OLEH, NIGERIA

CHARACTERIZATION OF SOIL PROFILE OF DHAKA CITY USING ELECTRICAL RESISTIVITY TOMOGRAPHY (ERT)

Geology and hydrology of Tuaran

Hydrogeophysical investigation in selected parts of Irepodun/Ifelodun local government area of Ekiti State, Southwestern Nigeria

Hydro-Geophysical Investigation of the Federal Housing Estate Akure, Southwestern Nigeria

Proposed Cemetery Thornhill Road. Tier One Hydrogeological Risk Assessment. Peter Mitchell Associates

Geophysical Investigation of Egbeta, Edo State, Nigeria, Using Electrical Resistivity Survey to Assess the Ground water Potential

Connecticut's Aquifers

Evaluation of the hydraulic gradient at an island for low-level nuclear waste disposal

AN APPRAISAL OF CERTAIN CHARACTERISTICS OF AQUIFER IN CHIKUN LOCAL GOVERNMENT AREA OF KADUNA, NIGERIA

Geophysical Surveys for Groundwater Modelling of Coastal Golf Courses

Received 12 February 2010 Accepted 25 March Abstract. Keywords: sounding resistivity, gem-bearing gravel layer, Wenner, Schlumberger

Assessment of Ground Water in a Part of Coastal West Bengal using Geo-Electrical Method

Groundwater Exploration In Parts Of Mangu- Halle North-Central Nigeria.

GROUNDWATER OCCURRENCE IN KENYA

Development of geophysical investigation for verifying treatment efficiency of underground cavities

Integrated Geophysical Interpretation On The Groundwater Aquifer (At The North Western Part of Sinai, Egypt)

Geophysical investigation for groundwater exploration at UKM's Kuala Pilah Matriculation Centre, Negeri Sembilan

International Journal of Basic and Applied Sciences Raibu et. al., Vol. 1 No. 2 ISSN: (A peer reviewed International Journal)

Utility of the 2-D Multi-Electrode Resistivity Imaging Technique in Groundwater Exploration in the Voltaian Sedimentary Basin, Northern Ghana

Geophysics for Environmental and Geotechnical Applications

Integrated Geophysical Model for Suswa Geothermal Prospect using Resistivity, Seismics and Gravity Survey Data in Kenya

Name. 4. The diagram below shows a soil profile formed in an area of granite bedrock. Four different soil horizons, A, B, C, and D, are shown.

Derived Relations between Geoelectric and Hydraulic Parameters in Bara Basin, Sudan

Identification of aquifer zones by VES method: A case study from Mangalore block, Tamil Nadu, S. India

GSJ: Volume 6, Issue 4, April 2018, Online: ISSN

Geophysical Investigation of the Precambrian Marble Occurrence in Itobe Area, Central Nigeria

Aspects of Geophysical Exploration for Groundwater Using Vertical Electrical Sounding (VES) in Parts of University of Benin, Benin City, Edo State

INTEGRATED INVESTIGATION TO LOCATE A WASTE DISPOSAL AREA

Geophysics Course Introduction to DC Resistivity

HYDROGEOLOGICAL PROPERTIES OF THE UG2 PYROXENITE AQUIFERS OF THE BUSHVELD COMPLEX

AWRA PMAS Engineers Club of Philadelphia. A Geologic Perspective on Stormwater

D.C. RESISTIVITY INVESTIGATION OF SUBSURFACE LAYERING FOR GEOTECHNICAL APPLICATION IN MILLENNIUM CITY, KADUNA, KADUNA STATE.

Aquifer Vulnerability Assessment in Some Towns of Yenagoa, South-South Nigeria

CHAPTER 9 SUMMARY AND CONCLUSIONS

Groundwater Level Monitoring of the Quaternary Aquifer at Al Ain City, United Arab Emirates (UAE) using Geophysical Methods

ASSESSMENT OF GROUNDWATER POTENTIAL IN ARUJO- RODI KOPANY AREA, HOMA BAY COUNTY, KENYA. NAME: AYETE DAVID OMAJILONG

Vertical Electrical Sounding (Ves) For The Determination Of Under Ground Resistivity In Part Of Nigeria Wilberforce Island,Amassoma, Bayelsa State

Transcription:

An Interdisciplinary Response to Mine Water Challenges - Sui, Sun & Wang (eds) 2014 China University of Mining and Technology Press, Xuzhou, ISBN 978-7-5646-2437-8 Geoelectrical Investigations at Three Bridge Sites, North Nyala, Southern Darfour State, West-Sudan E. A. Elzein Mohammed 1, G. Q. Xue 2 1 Faculty of Pure and Applied Sciences, International University of Africa, P. O. Box: 2469, Khartoum, Sudan, Email: zein67624@yahoo.com 2 Institute of Geology and Geophysics, Chinese Academy of Sciences, Beijing,100029, China Abstract Resistivity measurements were carried out to delineate the depth of the basement rocks (bedrock) and the lithology of the overlying sediments for the purpose of bridges construction route. The survey was conducted at three sites: Andro, Duma and Manwashi, north Nyala, Southern Darfur State, Western Sudan. These sites (Andro, Duma and Manwashi ) are located along Nyala _ El-Fashir road at a distance approximately of 15km, 42km and 75km from Nyala (respectively). The surface geology of the area is dominated by the basement complex rocks which are overlain by thin layer of superficial deposits.the modeling of the VES data was done using IX1D software. The final results of the modeled and interpreted resistivity data are presented in the form of geoelectrical sections. These sections have shown a close agreement with the geological and hydrogeological conditions of the area. Three zones were identified in these sections, they are the top dry zone (<1 m to >3 m) representing the superficial deposits, the middle zone (Saturated zone) represents the groundwater aquifer. It varies in lithology from weathered and cracked basement rocks to the Alluvial deposits with a significant heterogeneous nature which varies from clayey, silty, sandy, pebbly and boulders layers. The bottom zone (Fresh basement rocks) represents the bedrock. It indicate an increase of hardness and compaction from Andro, Duma and Manshawi sites respectively. These findings can be used successfully for constructions the bridges of the three sites. Keywords resistivity, VES, bridge, site investigation, Darfur Introduction In this study, vertical electrical sounding using Schlumberger array were carried out to investigate the selected routes of three bridge sites, North Nyala, Southern Darfour State, West-Sudan. These sites (Andro, Duma and Manwashi ) are located along Nyala _ El-Fashir road at a distance approximately of 15 km, 42 km and 75 km from Nyala (respectively), as shown in fig.1. The climate of the area is hot and dry during most of the year; the rainy season lasts for three months, from June to September. The mean annual precipitation rates is 450 mm. Runoff concentration is closely linked to the underlying geology and to surface relief. Fig.2 shows the drainage system in the basement complex and the volcanic. There are no drainage lineaments in the sand dunes (Qoz) area which overlying the Nubian sandstone Formation. Recharge of the aquifer in Darfur occurs mainly through runoff concentration in the basement complex area and subsequent infiltration in the wadi channels. Recharge to the wadi aquifers is dependent on the state of depletion and the particular geological setting ( Thorweihe,. et al.. 1990). The first persons to describe the geology of the area were Delany (1952), Whiteman (1971), Sonntag, et al. (1982), and Thorweihe (1990), Several groundwater development project were carried out in Darfour (BRGM 1983; HUMPHERYS and Partner 1983; and HUNTING 1976). Geophysics plays an important role in geotechnical investigations, for a wide range of projects related to bridge and Dams site location, roadworks. Resistivity are capable of mapping a variety of geological structures, such as soil overburden, aquifers, contamination plumes, sea water intrusion, faults and fractures (Kunetz 1966; Griffith and Barker 1993; 309

Barker 1996, Flathe 1955, Morries et al. 1996, Dobecki and Romig 1985, Elzein 1998, Ward 1990, Yang et al. 1994). The main objective of this study is to delineate the depth of the basement rocks (bedrock) and the lithology of the overlying sediments for the purpose of the Bridges route into the three sites: Andro, Duma and Manwashi. Fig.1 Satellite image showing locations of the study area 310

Fig.2 Drainage systems in Darfur (after ONC, 1979 and Hunting, 1970) The geology and hydrogeology of the investigated sites The Geology of Darfur area (fig.3) can be summarized into a few simple rock units (Thorweihe et al. 1990), which are from the bottom to the top: 311

(e) Superficial Deposits (d) Volcanic Rocks (c) Nubian Sandstone Formation (b) Metasediments (a) Basement Complex The investigated area is situated on the basement complex which consist mainly of pre- Cambrian metamorphic rocks intruded by igneous rocks. The basement is overlain by Alluvial deposits of shallow thickness (<1m to >20m). The Alluvial is heterogeneous and is composed of clay beds, silts and sand. Gravels and boulders are found interspread within the sediments. The basement rocks are composed mainly of Gneisses and Schists. Quartz veins occur in the whole area. The fresh basement is generally covered by a zone of altered basement rocks of highly variable thickness. The thickness is associated with the distribution of the drainage system and reaches up to 100m underneath the major wadies. Metasediments are generally covered by the Qoz, occurred south and east of Sag El Naam Basin. The Nubian formation covers most of the landscape in the area. It is composed of medium to coarse grained, cross-bedded sandstone, massive to conglomeritic sandstone. Volcanic rocks of middle to upper Tertiary age, and probably Miocene, range from basalts to trachyte. crop out in the Meidob Hills in the north, in the Tagabo hills between Mellit and Malha and in the Jebel Marra complex with it s eastward directed lava outflows to the Shagera Basin (PUDLO et al in press). The superficial deposits in the area exist as Alluvial and Qoz. The Alluvial are in the head water sections of wadis are mainly composed of sand with some clay lenses. The thickness of Alluvial ranges from <10 m up to 60 m. The groundwater aquifers in the area are the weathered basement and the Alluvial deposits of the wadis. The alluvial aquifer is mainly composed of medium to coarse sand. The water table is near the surface (<1 m to >3 m), this level may increase during the dry season and in the years with low rain fall. Electrical resistivity survey In order to delineate variations of the alluvial deposits thickness at the wadis sites, the best geophysical techniques to be employed are the electrical or electromagnetic methods because of the electrical contrasts between conductive over-bank deposits and the resistive coarsegrained sediments in the inner wadis, as well the contrast between the higher resistive basement rocks and the overlying saturated zone of weathered basement and the alluvial deposits which are overlain by more resistive dry superficial deposits. The electrical resistivity method was selected because the Resistivitymeter is available, being less costly, more portable and the shallow nature of the basement rocks and the water table. In resistivity measurements a direct current is injected into the ground using two electrodes and the voltage difference is measured between another two electrodes. The ratio of the voltage output to the current input is referred to as the impedance of the earth (Dobrin, 1976). The Schlumberger array is widely used in the resistivity surveys because it is an efficient means of collecting a large number of data points and these observations are sensitive to the lateral position and depth characteristics of the resistivity distribution. In this array the 312

spacing between the current electrodes (AB) are much larger than the potential electrodes (MN), MN=AB/5. In vertical electrical sounding the spacing between the current electrodes is usually increased while the spacing between the potential electrodes remains fixed for several readings. Fig. 3 Geological map of Darfur area (after BRGM 1981) The apparent resistivity, can be calculated by using the following equation: a kr (1) where k is the geometrical factor and R is the resistance of the ground. The geometry scheme for this array is shown in Fig. 4. 313

Fig. 4 Sketch diagram of the Schlumberger array. (a: distance between the potential electrodes) Data were collected during the field trip (17 22, Nov. 2011) by using ABEM (SAS4000) TERRAMETER. A total of 13 vertical electrical soundings were performed, using the Schlumberger electrode configuration, covering the whole of the three sites. To ensure a penetration of up to 50 m, a maximum current electrode separation of 300 m was selected. The resistivity soundings were carried out simultaneously with the drilling program. The boreholes or trial pits are conveniently sited at regular intervals along the bridge routes. Most of the sounding points were conducted nearby boreholes and dug wells for correlation purposes. The location of the resistivity lines are shown in Fig. 5. Results and interpretation of the resistivity data Qualitative interpretation of resistivity sounding data, involves the study of the types of sounding curves obtained. Such curves are known as K, H, A and Q type curves (Keller and Frischknecht, 1966). Typical examples of these curves types are shown in fig 6. The interpretation of the curves constitutes the basis of the quantitative interpretation of the electrical sounding data. The main purposes of quantitative interpretation of VES are to determine the thickness of the different formations having different resistivities. The inversion and modeling of the resistivity sounding data is carried out by using inversion software (IX1D). The program calculates the apparent resistivity, thickness and the number of layers. The interpretation was checked by calibration of sounding data with the nearby boreholes data. Correlation with the known geology, trial pits and boreholes gives a realistic interpretation. The optimum depth of exploration would be of the order of 20 to 30 m although it is possible to produce interpretations up to a depth of 50 m. Geoelectrical cross sections were obtained by combining one dimension resistivity models and boreholes information. The results of the three sites are discussed through their geoelectrical cross-sections, extending north-south parallel to the suggested bridge routes. The three sites are located in the wadis plain. The geology consists of alluvial sediments, which are wadis deposits with medium- grained sands, gravels and boulders in the filled channels separated by fine-grained sediments (over-banks deposits) of clays and silts. Andro site Andro site is located north Nyala at a distance of about 15km from the town, latitude 12.184 and longitude 24.9632 (fig. 5). The resistivity survey line has a length of 60m, with 4 VES points and one borehole. The distance between the VES points is 20m, two points are situated at the over-bank (VES. No. 1&4) and the other two (VES. No. 2&3) are situated at the inner part of the Wadi. Fig. 7 shows the geoelectrical cross-section of Andro site. 314

Fig.5 The location of the Resistivity survey Sites Fig.6 Examples of four types of the three layer Schlumberger sounding curves (Zohdy, 1974) 315

Fig.7 Geoelectrical Section for Adnro Site The results of the interpreted curves along this line (appendix) are corresponding to three and four layers case. The curve types in the central part of the line (inner part of the wadi) are H types (VES.3& 4). The high resistivity of the bottom layer (>1000 Ω m) represents the fresh basement rocks. The middle layer has low resistivity (160 166 Ω m) which are due to the presence of the saturated zone (groundwater aquifer), which is probably composed of weathered or cracked basement rocks and or alluvial deposits boulder intercalated with sandy or silty clay. The top layer is of high resistivity layer (670 1434 Ω m) representing the dry zone of sandy superficial deposits. The curve types in the over-bank of the wadi are A and HA type curves (VES.1 & 4) where the resistivity of the middle layer varies from 188 to 273 Ohm-m. It represents the saturated zone (this layer is of relatively higher resistivity compared with the same layer in VES 2&3. This reinforce the idea that the basement in the over-bank is not highly weathered compared with inner part of the Wadis). The layer is intercalated with sandy or silty clay lense in the northern part under VES.4 (HA type). The bottom layer has higher resistivity values (863-1597 Ω m) due to presence of fresh basement rock. While the top layer has resistivity values which varies from 88 to 93 Ohm.m representing the dry clayey sand of superficial deposits Quantitatively, this section has three main layers, these are : 1) The top dry superficial deposits which has a thickness varying from <1 m in the inner part of the wadi to >3 m in the over-bank, this depth represents the groundwater level in this site. 2) The middle layer represents the saturated zone (groundwater aquifer) which is interpreted as moderately weathered or cracked basement rocks or as alluvial deposits of boulder intercalated with sandy and silty clay. 3) The bottom layer represents the fresh basement rock and has a depth which varies from 12 to 17 m. 316

Table1 Results of the quantitative interpretation of the resistivity data, Andro site Resistivity Values Ohm (m) Interpreted layer Thickness (m) Depth (m) 90-1400 Dry top layer (Superficial < 1 m to > 3 m deposits) 160-270 Saturated zone 10-13 >1000 Fresh basement rocks 13-15 Duma site This site is located north Nyala at a distance of about 42km from the town, latitude 12.4572 and longitude 24.9725 (fig. 5). The resistivity survey line has a length of 400m, with 5 VES points and 12 boreholes. The distance between the VES points is 100m, two points are situated at the over-bank (VES. No. 1&5) and three points (VES. No. 2&3) are located at the inner part of the Wadi. Fig. 8. is the geoelectrical cross-section of Duma site. The results of the interpreted curves along this line are corresponding to three and four layers case. The curve types in the southern and central part of the line are KH types (VES.1, 2& 3) while the curves in the northern part of the line (VES. 4 &5) are H type curves. This indicates a top dry layer of lateral facies changes varying from clayey in the southern part to sandy in the northern part of the line. The resistivity along this layer varies from 122 to 528 Ohm.m. The top layer is underlain by a zone of low resistivity values, which varies from 32 to 73 Ohm.m. It represents the saturated zone (groundwater aquifer). The aquifer is composed of highly weathered basement rocks or alluvial deposits of pebbly sandy and silty clays.the low resistivity value (7 Ω m) in the southern part of this zone may represent clayey or silty clayey lenses. The saturated zone is underlain by a high resistivity zone (>10000 Ω m) which indicates the presence of fresh basement rocks. Quantitatively, this section has three main layers, and can be described as follows: (1) The top dry superficial deposits which has a thickness varying from <.5 m in the northern part of the line to about 2 m in the southern part of the line. This depth (<.5 m 2 m) may represents the groundwater level in this site. (2) The middle layer represents the saturated zone (groundwater aquifer) which is interpreted as highly weathered basement rocks or as alluvial deposits of pebbly sandy and silty clays. (3) The bottom layer represents the fresh basement rocks, and it has a depth which varies from 4 m to 21 m. The topography of the basement rocks (Bedrock) along this line is highly undulating with a lower depth of 4 m under (VES.1). Table2 Results of the quantitative interpretation of the resistivity data, Duma site Resistivity values Ω m Interpreted layers Thickness (m) Depth (m) 120-520 Top dry layer (superficial deposits) < 0.5 m to 2 m 50-60 Saturated zone 3-20 400-4000 Fresh basement rocks 4-22 317

Fig.8 Geoelectrical Section for Duma Site Manwashi site This site is located north Nyala at a distance of about 75km from the town, at latitude 12.6901 and longitude 24.9933 (fig. 5).. The resistivity survey line has a length of 110m, with 4 VES points and 6 boreholes. The distance between the VES points is 36m, two points are located at the over-bank (VES. No. 1&4) and the other two (VES. No. 2&3) are situated at the inner part of the Wadi. Fig.9. is the geoelectrical cross-section of Manshawi site. The results of the interpreted curves along this line are corresponding to three layers case (H type curve). The top layer has a resistivity which varies from high values (>578 Ohm.m) in the inner part of the Wadi to relatively lower values (132 to 291 Ohm.m) in the over-bank of the Wadi. This indicates the presence of a dry top layer of lateral facies changes from sand in the inner part of the Wadi to silty clay in the over-bank of the Wadi. The top layer is underlain by a zone of low resistivity values, which varies from 13 to 48 Ohm.m, it represents the saturated zone (groundwater aquifer) which is probably composed of highly weathered basement rocks or alluvial deposits of sandy and silty clay.the low resistivity value (13 Ω m) in the northern part of this zone (over-bank) may represent a clayey or silty clayey lenses. The high resistivity of the bottom layer (>27000 Ω m) is due to the presence of fresh basement rocks. Quantitatively, this section has three main layers, and can be described as follows: 1)The top dry superficial deposits which has a thickness varying from 0.5m in the inner part of the wadi to about 2m in the over-bank. This depth represents the groundwater level in this site. 2) The middle layer represents the saturated zone (groundwater aquifer) which is interpreted as highly weathered basement rocks or as alluvial deposits of sandy and silty clay. 318

3) The bottom layer represents the fresh basement rocks. It has a depth which varies from 11 to 22m. The topography of the basement rocks (Bedrock) along this line is highly undulating (fig. 9). Fig.9 Geoelectrical Section for Manwashi Site Table3 Results of the quantitative interpretation of the resistivity data, Manwashi site Resistivity values Ω m Interpreted layers Thickness Depth (m) (m) 130-1300 Dry top layer (Superficial deposits) 0.5-2 30-50 Saturated zone 10-20 27000-60000 Fresh basement rocks 11-22 Conclusions and Recommendations Geoelectrical measurements were successfully used for site investigations, in order to map the topography of the subsurface bedrock, and the lithology of the overlying sediments as well as to delineate the groundwater levels. The most significant conclusions of the current study are as follows: (1) The topography of the basement is undulating, varying in depth from < 4 m to >20 m. (2) There is a similarity in the lithology of the saturated zone of Duma and Manshawi Sites. 319

(3) The groundwater level varies from <1 m in the inner part of the Wadis to >3m in the overbank deposits. This level may increase during the dry season and in the years with low rainfall. (4) The geological sections of the three sites can generally be divided into three zones as follows: (a) The top dry zone (<1 m to >3 m) representing the superficial deposits (b) The middle zone (Saturated zone) represents the groundwater aquifer. Its lithology varies from weathered and cracked basement rocks to the Alluvial deposits with their heterogeneity nature which varies from clayey, silty, sandy, pebbly and boulders layers. (c) The bottom zone (Fresh basement rocks) represents the bedrock. It shows the increase of hardness and compaction from Andro, Duma and Manshawi sites respectively. (5) There are several clay layers which are intercalated with sand as proved by drilling. (6) The thickness of the weathered basement rock in the inner parts of the wadis is more than in the over-bank. (7) The saturated zone in Duma and Manwashi sites must be excavated up to the fresh basement rocks. (8) The upper-part of the saturated zone in Andro site must be excavated while the cracks and joints in the lower part of this zone can be filled in by cement grouting. (9) The interpreted resistivity results agree with the general geology and drilling in formations as well as the engineering work in the area References Barker RD (1996) The Application of electrical tomography in groundwater contamination studies: EAGE. 58th conference and technical exhibition extended abstract, p 82 BRGM (1981) Bureau de researchers Geological and Minerals : Geological Map of the Sudan, 1:2000000 BRGM (1983) Rural Water Supply project in western Sudan, water resources and requirements study, final report, unpublished Delany FM (1952) Recent contribution to the geology of Sudan, Chrons. Mines Colon, 197 Dobrin MB (1976) Introduction to geophysical prospecting: McGraw-Hill Book Company, Third Edition Dobecki TL, Romig PR (1985) Geotechnical and groundwater geophysics. Geophysics 50: 2621-2636 Elzein EA (1998) Electrical resistivity imaging surveys to map the interface between fresh and saline groundwater in North Kedah and Perlis, Malaysia, M.Sc thesis, Universiti Sains Malaysia (Unpub.) Flathe H (1955) Possibilities and limitations in applying geoelectrical methods to hydrogeological problems in the coastal areas of North-West Germanny: Geophysical prospecting 3: 95-110 Griffith DH, Barker RD (1993) Two-dimensional resistivity, imaging and modeling in areas with complex geology. Journal of Applied Geophysics 29: 211-226 Humpherys, Partners (1983) El Fasher water Supply, final report, unpublished Hunting Technical Services Ltd, Macdonald, (1970): Water Survey and Developement Annex 2, Part 1 & 11, unpublished, London Keller GV, Frischknecht FC (1966) Electrical method for geophysical prospecting. Elsevier Science & Technology Kunetz G (1966) Principles of direct current resistivity prospecting, Gebruder Borntraeger, Berlin Morris M, et al (1996) Geoelectrical monitoring a tracer injection experiment modeling and interpretation: European Journal of Environmental and Engineering Geophysics ONC Operation 1 Navigation Chart (1979) ONC-KY 2nd Ed., Defense Mapping Agency Aerospace Center, St. Lou is Air Force Station, Missouri Pudlo D, Franz G, Pasteels P (in press) Fractionation of mantle melts-bimodal volcanism and continuous differential products in volcanic rocks from Darfur/ Sudan. J. of volcanology Thorweihe U, et al (1990) Hydrological and hydrogeological investigations in the Darfur Area, Western Sudan. Berliner Geowiss. Abh, p279-326 Ward SH (1990) Resistivity and induced polarization methods: in Geotechnical and environmental geophysics, Vol. 1, Society of Exploration Geophysics Tulsa Whiteman AJ (1971) The geology of the Sudan Republic, Oxford Univ. Press 209p Zohdy AA (1974) Application of surface geophysics to groundwater applications, Chapter, D1, Electrical methods, techniques of water resources investigations of the U, S. Geol. Surv 320