[ XEVO G2-XS QTOF ] EXTRAORDINARY POSSIBILITIES FOR YOUR EVERYDAY ANALYSIS

Similar documents
FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

IN QUALITATIVE ANALYSIS,

[ xevo G2 tof ] Your Quantitative and Qualitative Questions Answered. Exactly.

[ OSTRO PASS-THROUGH SAMPLE PREPARATION PRODUCT ] The Simpler Way to Cleaner Samples

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

ABI 3200 Q TRAP LC/MS/MS System

2010 Waters Corporation. Xevo TQ-S for Bioanalysis

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

[ FOOD SAFETY SOLUTIONS ] FASTER, EASIER, AND MORE ACCURATE FOOD SAFETY ANALYSES

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

ImprovIng ADmE ScrEEnIng productivity In Drug DIScovEry

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

[ Care and Use Manual ]

Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

Evaluation of a New HPLC, a New Tandem MS and a New Data Processing Software for General Clinical Use

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Introduction to Fourier Transform Infrared Spectroscopy

UNIFI - Targeted and Untargeted Screening MS Software

Guide to Peptide Quantitation. Agilent clinical research

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

EXPRESSION MORE PEPTIDES. MORE PROTEINS. MORE REPRODUCIBILITY. MORE QUANTIFICATION.

ApplicationNOTE Abstract

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Introduction to Fourier Transform Infrared Spectroscopy

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

High-Field Orbitrap Creating new possibilities

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

for XPS surface analysis

Multi-residue analysis of pesticides by GC-HRMS

Translational Biomarker Core

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

Stephen McDonald and Mark D. Wrona Waters Corporation, Milford, MA, USA INT RO DU C T ION. Batch-from-Structure Analysis WAT E R S SO LU T IONS

ICP-MS. High Resolution ICP-MS.

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Improved Throughput and Reproducibility for Targeted Protein Quantification Using a New High-Performance Triple Quadrupole Mass Spectrometer

of mass spectrometry

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

MetWorks Metabolite Identification Software

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Insights Into the Nanoworld Analysis of Nanoparticles with ICP-MS

Thermo Scientific ELEMENT GD PLUS Glow Discharge Mass Spectrometer. Defining quality standards for the analysis of solid samples

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

ANALYSIS OF BASIC COMPOUNDS

Designed for Accuracy. Innovation with Integrity. High resolution quantitative proteomics LC-MS

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

[ instrument specifications ]

A Study of Stability, Robustness and Time Efficiency of a New HPLC and a New Tandem MS

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

ultimate efficiency unleashed [ Cortecs 1.6 µm columns ]

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Finnigan LCQ Advantage MAX

Keysight Technologies Instrumented Indentation Testing with the Keysight Nano Indenter G200. Application Note

A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection

Quan/Qual Analyses. Unmatched Confidence for. Thermo Scientific Q Exactive Orbitrap LC-MS/MS System. Identify Quantify Confirm

MassHunter TOF/QTOF Users Meeting

WALKUP LC/MS FOR PHARMACEUTICAL R&D

Powerful Scan Modes of QTRAP System Technology

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

SIFT-MS. technology overview

Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Thermo Finnigan LTQ. Specifications

Stephen McDonald, Mark D. Wrona, Jeff Goshawk Waters Corporation, Milford, MA, USA INTRODUCTION

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

This document is a preview generated by EVS

Making Sense of Differences in LCMS Data: Integrated Tools

SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES

Keysight Technologies Young s Modulus of Dielectric Low-k Materials. Application Note

protein interaction analysis bulletin 6300

MassHunter Software Overview

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Thermo Fisher Scientific, San Jose, CA; 2 Kelleher Lab, Northwestern University, Evanston, IL; 3

Routine MS Detection for USP Chromatographic Methods

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

1.7µm Fortis C18 UHPLC Columns

UPLC Intact MASS Analysis Application Kit

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

2017 Source of Foreign Income Earned By Fund

Transcription:

[ XEV G2-XS QTF ] EXTRARDIARY PSSIBILITIES FR YUR EVERYDAY AALYSIS

EXTREME SESITIVITY, EXTRARDIARY SELECTIVITY, Whether you re a scientist who wants to truly understand your samples, or a lab manager with urgent deadlines to meet, the Xevo G2-XS QTof is the ultimate solution. This high-performance benchtop QTof gives you the confidence to make the right decisions quickly and easily using the highest quality, most comprehensive information. Powerful underlying technologies seamlessly integrate with industry-leading separations and informatics solutions. Your lab will gain efficiency and productivity from proven robustness, reliability, and speed of analysis, with the flexibility to adapt to your changing needs. The Xevo G2-XS QTof is fully accessible to expert and nonexpert alike, with its intuitive user interface and automated setup features, giving you the peace of mind that the system is always performing at its best. ACQUITY UPLC H-Class System with Xevo G2-XS QTof

[ XEV G2-XS QTF ] EXCEPTIAL SLUTIS High Resolution Data Independent of Scan Speed 878.39 Single MS Scan 878.88 Resolution (FWHM) >4, EGIEERED SIMPLICITY A design philosophy that delivers a combination of the highest performance with system versatility and simplicity of operation. HIGH PERFRMACE StepWave Unique, off-axis ion source technology that delivers robust, reproducible, class-leading sensitivity. 879.39 879.88 88.39 877 878 879 88 881 882 XS Collision Cell Collision cell technology with enhanced ion transmission, resulting in increased sensitivity and resolution. QuanTof Technology For dynamic range, speed and quantitative capability designed to integrate seamlessly with Waters industryleading separations solutions. Extracted Ion Chromatogram 878.39 UPLC/TofMRM High transmission mode giving improved limits of detection in targeted quantitative experiments, delivering the most sensitive and specific high resolution data on the market. Peak width at 1 height 1.5 seconds.9 1. 1.1 1.2 1.3 1.4 Base Peak Chromatogram 3 spectra per second Time UPLC/MS E A simple method of data acquisition that comprehensively catalogs complex samples in a single analysis. UPLC/FastDDA For automated, intelligent, fast data directed analysis giving up to 3 high quality accurate mass MS/MS spectra per second for confirmation of known compounds and characterization of unknowns. VERSATILITY Universal Ion Source Architecture The most extensive range of interface capabilities to service the broadest range of applications. 1 Time.9 1. 1.1 1.2 1.3 1.4 Top: Single MS scan from peak apex, showing mass resolution >4, Middle: Extracted ion chromatogram showing peak width of 1.5 seconds at 1 height Bottom: UPLC/MS Base Peak chromatogram acquired at 3 spectra per second SIMPLICITY F PERATI System Solutions The most complete system solutions backed by superior support to ensure your success. IntelliStart Technology Guarantees maximum system performance and usability for reproducible results.

For complex samples it is often challenging to obtain meaningful quantitative and qualitative MS data for every component of interest. Success is typically governed either by the ability to detect the ions, or the ability to resolve them from others with similar. With the Xevo G2-XS QTof, class-leading sensitivity enables you to detect more lowlevel components than ever before, while significantly increased mass resolution at full transmission enhances your ability to distinguish them from one another, enabling meaningful data to be collected for each one. Segmented Quadrupole Detect More Compounds With >15x Sensitivity >15x increase at equivalent resolution 195.9 Caffeine Resolution >2k FWHM @ 195 194.12 The XS Collision Cell focuses the ions such that they enter the Tof in a narrow, precisely controlled ion beam, resulting in improved transmission with a simultaneous increase in both sensitivity and resolution. This is described in more detail in the White Paper: The XS Collision Cell from Waters, Increased sensitivity and resolution for Time-of-Flight mass spectrometry (72571en). With XS Collision Cell Potential Interference 194.89 195.12 196.9 Without XS Collision Cell 194 195 196 197 Time.3.34.38.42.46.5.54.58 UPLC/MS chromatograms acquired at 1 spectra per second. The XS Collision Cell delivers a significant increase in signal, while maintaining the fast data acquisition rate necessary for narrow UPLC peaks, and the mass resolution required to separate potential interferences.

MAXIMUM RBUSTESS WITH CMPRMISE I PERFRMACE For sample limited and demanding analytical experiments, you rely on achieving and maintaining the highest possible sensitivity from your system. This in itself is a challenge, which becomes even more difficult when, after running many complex samples, sensitivity is compromised due to contamination. With the Xevo G2-XS QTof, MS signals are dramatically increased compared to previous source designs. At the same time, critical hardware components stay clean for longer, so your results are more reproducible and your laboratory stays productive. Second Stage Focused ion beam First Stage Eliminated neutrals Conjoined T-Wave devices Reproducible Results With Less Downtime 3 25 5 RSD 2 StepWave ion optics maximize instrument sensitivity while minimizing routine maintenance. Ions transfer from the source with the highest possible efficiency, while potential contaminants are actively filtered out. This is described in more detail in the White Paper: StepWave - Enhancing MS Sensitivity and Robustness (724175en). Peak Area 15 5 5 15 2 25 3 35 4 45 5 Replicate The drug Verapamil was spiked into protein-precipitated plasma and UPLC/MS data acquired at 1 spectra per second. The relative standard deviation in peak area across 11 replicate samples run in a series of 5 injections is 5.

[ XEV G2-XS QTF ] When the concentrations of different components in your sample show large variations, each still needs to be measured accurately, both in terms of peak area and accurate mass. For maximum efficiency and productivity, this should be achieved in a single analysis and as quickly as possible. Dual-stage reflection With the Xevo G2-XS QTof, because mass resolution is completely independent of scan speed, the narrowest chromatographic peaks from the most complex sample matrices can be identified and quantified with no compromise in MS performance. The MS integrates seamlessly with Waters industry-leading separations solutions to create powerful analytical systems for your most challenging scientific problems. Improved Confidence From <1ppm Mass Errors Replicate bserved Error (ppm) 1 235.1811.4 5 235.1812.9 235.1812.9 15 235.1812.9 2 235.181. 25 235.1811.4 3 235.1811.4 35 235.1812.9 4 235.181. 45 235.181. 5 235.1811.4 The drug Lidocaine was spiked into protein-precipitated plasma and UPLC/MS data acquired at 1 spectra per second. The theoretical for the protonated molecule with elemental composition C 14 H 23 2 is 235.181. RMS mass error for 11 replicate samples run in a series of 5 injections is.6ppm. QuanTof s innovative geometry and ion detection system combine to enhance sensitivity and provide outstanding mass resolution and dynamic range, giving you quantitative performance, mass accuracy and speed of analysis, simultaneously. This is described in more detail in the White Paper: QuanTof, High-Resolution, Accurate-Mass, Quantitative oatof MS Technology (724545en). High field pusher Detector

HIGH QUALITY, CMPREHESIVE QUALITATIVE AD QUATITATIVE IFRMATI UPLC/Tof-MRM For targeted quantitative analysis, one of the biggest challenges is to accurately and precisely quantify the components of interest down to the lowest possible levels, often in the presence of complex matrices. The Xevo G2-XS QTof gives you class-leading quantitative performance in real terms, demonstrated by limits of detection and quantification that are superior to anything seen before on a high resolution instrument. Tof-MRM takes full advantage of the efficient front-end transmission from the StepWave, enhanced sensitivity and selectivity from the XS Collision Cell, and high dynamic range from the QuanTof. When used in conjunction with Target Enhancement* capabilities this provides a powerful tool for targeted quantitative analysis. Linear Response Down to Sub-fg Loadings 8 1/X weighting R 2 =.995 Peak Area 6 4 2 - Loading - 25 5 75 125 15 175 2 225 25 Graph showing the peak areas from UPLC/Tof-MRM analyses of the drug Buspirone, showing linear response over a range of loadings from.5fg to 2.5pg on-column. 1x Tof-MRM Mode S: (RMS) 1148:1 Buspirone 5fg on-column MS Mode S: (RMS) 8:1.1.2.3.4.5.6.7.8.9 1. 1.1 1.2 1.3 1.4 1.5 1.6 1.7 Time UPLC/MS chromatograms showing 5fg injected on-column of the drug Buspirone, analyzed using Tof-MRM mode (top trace) and MS mode (bottom trace). Tof-MRM mode gives greater than 1-fold improvement in signal to noise. *Target Enhancement synchronizes the Tof with the arrival of ions in the specific range of interest. Transmission of those ions is selectively improved and the signal increases by up to 15 times.

UPLC/MS E A detailed understanding of your samples requires a complete set of qualitative and quantitative data for the maximum number of components, collected on a fast timescale in order to access the full benefits of modern separation techniques. With the Xevo G2-XS QTof you can quickly and easily set up a single experiment to collect accurate mass precursor and fragment ion data for every detectable component, whether chromatographically resolved or not. This represents the ultimate in qualitative information, with the same data also providing accurate quantitative profiles. And because the approach is un-targeted, you can go back to interrogate the data again at a later date as your scientific questions evolve. 25 MS E is a simple but powerful data acquisition method that provides high quality, comprehensive accurate mass precursor and fragment ion information from a single analysis. This is described in more detail in the White Paper: An verview of the Principles of MS E The Engine that Drives MS Performance (72436en). 2 8 12 16 2 24 28 32 8 12 16 2 24 28 32 Response 15 8 12 16 2 24 28 32 8 12 16 2 24 28 32 36 4 44 8 12 16 2 24 28 32 36 4 44 8 12 16 2 24 28 32 5 8 12 14 16 18 8 12 14 16 18 8 12 14 16 18 165.916 * 8 12 14 16 18.5 1. 1.5 Time * 33.266 * 455.2911 * 15.679 * 26.1644 12 14 16 18 2 22 24 26 28 3 32 34 36 38 4 42 44 46 48 5 A UPLC/MS E spectrum of Verapamil obtained at 1 spectra per second. The excellent mass accuracy and MassFragment software allow structures to be assigned to the fragment ions automatically, and compounds to be characterized with high confidence.

[ XEV G2-XS QTF ] UPLC/FastDDA btaining targeted MS/MS spectra for all components of interest in your sample would require detailed prior knowledge of the sample composition, and lengthy method development. Even once fully optimized, this would not provide fragmentation data for any unexpected or unknown components. The Xevo G2-XS QTof provides rapid, automated, intelligent accurate mass MS/MS capability for confirmation of known compounds or characterization of unknowns. Ions are intelligently selected for MS/MS acquisition in real time, as components elute from the chromatographic system. UPLC/FastDDA uses embedded algorithms to rapidly interrogate MS survey spectra, selecting co-eluting precursor ions for MS/MS analysis based on user-defined criteria. The collision energy for each spectrum is optimized according to precursor charge state and. For maximum efficiency, once a high quality MS/MS spectrum has been acquired, the system intelligently switches back to survey the MS spectrum for the next set of eligible precursor ions. 5 5 5 474.2 5 373.2 511.6 722.3 5 4 5 6 7 8 5 5 Time 5.5 5.75 6. 6.25 6.5 The instrument rapidly selects up to 3 precursor ions that correspond to the required charge states, isotope distribution, accurate mass include/exclude lists, and intensity thresholds set by the user. It then generates up to 3 high quality accurate mass MS/MS spectra per second.

FLEXIBILITY T ADAPT T CHAGIG EEDS The growing emphasis on efficiency and productivity in the laboratory demands analytical systems that are not only robust and reliable, but that also have the flexibility to accomplish a wide variety of tasks today, with future-proofing for the innovations of tomorrow. Waters Universal Ion Source Architecture enables the use of a single analytical platform for many different applications and molecule types, as well as providing the option to add new functionality as requirements and priorities change. All source options are designed to be quickly interchangeable and ready to use within minutes, maximizing versatility and minimizing downtime. ACQUITY UPC 2 ACQUITY UPLC M-Class System with HDX Technology ACQUITY UPLC H-Class ACQUITY UPLC I-Class ACQUITY UPLC M-Class

[ XEV G2-XS QTF ] ESI Electrospray Ionization APCI Atmospheric Pressure Chemical Ionization ESCi Dual ESI and APCi nanoflow ESI APPI Atmospheric Pressure Photo Ionization APCI Atmospheric Pressure Chemical Ionization ionkey/ms UIVERSAL I SURCE ARCHITECTURE Change your ion source not your instrument. The Xevo range of mass spectrometers all have multiple ion source options, which are interchangeable in minutes and provide optimal ionization for each function required in the laboratory. The Xevo G2-XS QTof is compatible with ESI, ESCi, APCI, APPI, APGC, ASAP, DESI, REIMS, and ionkey/ms and is also simply changed to DART (IonSense), LDTD (Phytronix), and LAESI (Protea) ion sources. APGC Atmospheric Pressure Gas Chromatography ASAP Atmospheric Solids Analysis Probe

CFIDET WRKFLWS, MEAIGFUL IFRMATI, BETTER RESULTS PREPARE AALYZE ITERPRET DECIDE IntelliStart ensures your system Enjoy an entirely new level of Process, visualize, compare and Generate reports, share results is ready to run for experts and quantitative and qualitative interpret the most complex data, and archive information beginners alike, giving you the capability thanks to powerful automatically. Then turn it into easily with Waters laboratory peace of mind that the system is underlying technologies, meaningful information quickly informatics. Have the always performing at its best. seamlessly integrated and easily with informatics confidence to make decisions with industry-leading solutions that support MS and faster and better than separations solutions. MS/MS workflows across many ever before. diverse applications. SIMPLICITY STARTS WITH ITELLISTART Xevo G2-XS QTof features IntelliStart technology, an intuitive interface that automates routine tasks and ensures reproducible data of the highest quality. Automated MS resolution and calibration checks Simple setup of diverse experiments Automated LC/MS system check Automated system monitoring

[ XEV G2-XS QTF ] IFRMATICS THAT DELIVERS ASWERS The Xevo G2-XS QTof is designed for use with either MassLynx or UIFI, reinforced by a comprehensive suite of informatics tools and platform solutions to suit your needs, whatever your application.

SALES FFICES: Australia 61 2 9933 1777 Austria 43 1 877 18 7 Belgium and Luxembourg 32 2 726 Brazil 55 11 4134 3788 Canada 1 8 252 4752 China 86 21 6156 2666 Czech Republic 42 2 617 11384 Denmark 45 46 59 88 Finland 358 9 5659 6288 France 33 1 3 48 72 Germany 49 6196 4 6 Hong Kong 852 2964 18 Hungary 36 1 35 586 India 91 8 492922 3 Ireland 353 1 448 15 Israel 9723 3731391 Italy 39 2 265 983 Japan 81 3 3471 7191 Korea 82 2 63 92 Malaysia 63 7841 1688 Mexico 52 55 52 186 The etherlands 31 76 58 72 orway 47 6 384 65 Poland 48 22 11 59 Portugal 351 21 893 61 77 Puerto Rico 1 787 747 8445 Singapore 65 6593 7 Spain 34 93 6 93 www.waters.com/qtof Sweden 46 8 555 115 Switzerland 41 56 676 7 Taiwan 886 2 258 55 UAE 971 4 214 62 38 UK 44 28 238 6 US 1 8 252 4752 Waters Corporation 34 Maple Street Milford, MA 1757 U.S.A. T: 58 478 2 F: 58 872 199 www.waters.com Waters, The Science of What s Possible, Xevo, ESCi, MassLynx, and UIFI are registered trademarks of Waters Corporation. Engineered Simplicity, StepWave, QuanTof, IntelliStart, REIMS, ionkey/ms, and nanoflow are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 217 Waters Corporation. Printed in the U.S.A. March 217 72574E TC-SIG