DPP06 Meeting of The American Physical Society. Production of negative ion plasmas using perfluoromethylcyclohexane (C 7 F 14 )

Similar documents
The Q Machine. 60 cm 198 cm Oven. Plasma. 6 cm 30 cm. 50 cm. Axial. Probe. PUMP End Plate Magnet Coil. Filament Cathode. Radial. Hot Plate.

Electrostatic ion-cyclotron waves in a plasma with heavy negative ions

Effect of parallel velocity shear on the excitation of electrostatic ion cyclotron waves

Hiden EQP Applications

Experimental verification of Boltzmann equilibrium for negative ions in weakly collisional electronegative plasmas

DESIGN CONSIDERATIONS FOR A LABORATORY DUSTY PLASMA WITH MAGNETIZED DUST PARTICLES

Langmuir Probes as a Diagnostic to Study Plasma Parameter Dependancies, and Ion Acoustic Wave Propogation

STRONG DOUBLE LAYER STRUCTURE IN THERMIONIC VACUUM ARC PLASMA *

ELECTROSTATIC ION-CYCLOTRON WAVES DRIVEN BY PARALLEL VELOCITY SHEAR

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Chemistry 311: Topic 3 - Mass Spectrometry

Characterization of an Oxygen Plasma by Using a Langmuir Probe in an Inductively Coupled Plasma

Dust density waves: ion flows and finite temperature effects

Capacitive Probe for Plasma Potential Measurements in a Vacuum diode and Polywell Device

Multicusp Sources for Ion Beam Lithography Applications

SPECTRAL INVESTIGATION OF A COMPLEX SPACE CHARGE STRUCTURE IN PLASMA

Measuring velocity of ion acoustic waves through plasma Hannah Saddler, Adam Egbert, and Warren Mardoum

Chapter 7 Plasma Basic

Harris: Quantitative Chemical Analysis, Eight Edition

Optical Pumping of Rubidium

Dynamics of Drift and Flute Modes in Linear Cylindrical ECR Plasma

Mass Spectrometry. Electron Ionization and Chemical Ionization

Chapter 7. Plasma Basics

DOE WEB SEMINAR,

EE143 Fall 2016 Microfabrication Technologies. Lecture 6: Thin Film Deposition Reading: Jaeger Chapter 6

Volume Production of D - Negative Ions in Low-Pressure D 2 Plasmas - Negative Ion Densities versus Plasma Parameters -

Sputter Ion Pump (Ion Pump) By Biswajit

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Extrel Application Note

Electric Field Measurements in Atmospheric Pressure Electric Discharges

vacuum analysis plasma diagnostics surface science gas analysis

Effects of cross field diffusion in a low pressure high density oxygen/silane plasma

Adjustment of electron temperature in ECR microwave plasma

Anode double layer in magnetized radio frequency inductively coupled hydrogen plasma

ELECTRON CYCLOTRON RESONANCE DISCHARGE AS A SOURCE FOR HYDROGEN AND DEUTERIUM IONS PRODUCTION

What are the six common sources of light?

Extrel is widely respected for the quality of mass spectrometer systems that are

Characterization of the operation of RITs with iodine

ETCHING Chapter 10. Mask. Photoresist

Waves and Instabilities in Dusty Plasmas

Chaotic-to-ordered state transition of cathode-sheath instabilities in DC glow discharge plasmas

Vacuum Pumps. Two general classes exist: Gas transfer physical removal of matter. Mechanical, diffusion, turbomolecular

Relationship between production and extraction of D - /H - negative ions in a volume negative ion source

M M e M M H M M H. Ion Sources

Huashun Zhang. Ion Sources. With 187 Figures and 26 Tables Э SCIENCE PRESS. Springer

Nitrogen Glow Discharge by a DC Virtual Cathode

ICPMS Doherty Lecture 1

What we will learn about now

Effect of negative ions on the characteristics of plasma in a cylindrical discharge

Generation of vacuum (pumps) and measurements

Enhancement of an IEC Device with a Helicon Ion Source for Helium-3 Fusion

The Gaseous Electronic Conference GEC reference cell as a benchmark for understanding microelectronics processing plasmas*

A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling

PIC-MCC/Fluid Hybrid Model for Low Pressure Capacitively Coupled O 2 Plasma

6.5 Optical-Coating-Deposition Technologies

1) Jozef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia

Slide 1 / A gas at a pressure of 10.0 Pa exerts a force of N on an area of 5.5 m 2 A 55 B 0.55 C 5.5 D 1.8 E 18

3 Use of Mass Spectra to Obtain Structural Information

Anomalous production of gaseous 4 He at the inside of DScathode during D 2 O-electrolysis

Gas utilization in remote plasma cleaning and stripping applications

Earlier Lecture. In the earlier lecture, we have seen non metallic sensors like Silicon diode, Cernox and Ruthenium Oxide.

THE GASEOUS STATE OF MATTER

Linear and Nonlinear Dust Acoustic Waves, Shocks and Stationary Structures in DC-Glow-Discharge Dusty Plasma Experiments.

Sheaths: More complicated than you think a

9/2/10 TYPES OF INTERMOLECULAR INTERACTIONS

Recombination and Decay of Plasma Produced by Washer Stacked Plasma Gun inside a Curved Vacuum Chamber

Electron Energy Distributions in a Radiofrequency Plasma. Expanded by Permanent Magnets

Lecture Note 1. 99% of the matter in the universe is in the plasma state. Solid -> liquid -> Gas -> Plasma (The fourth state of matter)

Quadrupole Mass Spectrometry Concepts. Mass spectrometers for residual gas analysis: Intermediate Level Users Guide

Characteristics and classification of plasmas

Lecture 15: Introduction to mass spectrometry-i

Nonlinear Diffusion in Magnetized Discharges. Francis F. Chen. Electrical Engineering Department

Mass Spectrometry. General Principles

LECTURE 5 SUMMARY OF KEY IDEAS

Previous Lecture. Electron beam lithoghraphy e - Electrons are generated in vacuum. Electron beams propagate in vacuum

An ion source performs the following two functions:

Section 5: Thin Film Deposition part 1 : sputtering and evaporation. Jaeger Chapter 6. EE143 Ali Javey

PIC-MCC/Fluid Hybrid Model for Low Pressure Capacitively Coupled O 2 Plasma

Laboratory studies of waves and instabilities in dusty plasmas*

( KS A ) (1) , vapour, vapor (USA) , saturation vapour pressure. , standard reference conditions for gases. , degree of saturation

Magnetic Field Configuration Dependence of Plasma Production and Parallel Transport in a Linear Plasma Device NUMBER )

Effect of Spiral Microwave Antenna Configuration on the Production of Nano-crystalline Film by Chemical Sputtering in ECR Plasma

Spatially resolved mass spectrometric sampling of inductively coupled plasmas using a movable sampling orifice

Lecture 8: Mass Spectrometry

A 200 kev Electrostatic Accelerator

Lecture 8: Mass Spectrometry

Mass Spectroscopy. Base peak. Molecular Ion peak. The positively charged fragments produced are separated, based on their mass/charge (m/z) ratio. M+.

AP Chapter 5: Gases Name

MS Goals and Applications. MS Goals and Applications

Plasma Optimization in a Multicusp Ion Source by Using a Monte Carlo Simulation

Secondary Ion Mass Spectroscopy (SIMS)

Effect of wall charging on an oxygen plasma created in a helicon diffusion reactor used for silica deposition

Using a Microwave Interferometer to Measure Plasma Density Mentor: Prof. W. Gekelman. P. Pribyl (UCLA)

CHARACTERIZATION OF A DC PLASMA WITH HOLLOW CATHODE EFFECT

Progress of experimental study on negative ion production and extraction

PRINCIPLES OF PLASMA DISCHARGES AND MATERIALS PROCESSING

Electrical Discharges Characterization of Planar Sputtering System

1) In what pressure range are mass spectrometers normally operated?

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

Transcription:

1 POSTER JP1.00100 [Bull. APS 51, 165 (2006)] DPP06 Meeting of The American Physical Society Production of negative ion plasmas using perfluoromethylcyclohexane (C 7 F 14 ) Su-Hyun Kim, Robert Merlino, Vladimir Nosenko, Ross Fisher, and Michael Miller Department of Physics and Astronomy The University of Iowa, Iowa City, IA Negative ion plasmas are produced by electron attachment to neutral molecules when an electronegative gas is introduced into a plasma. One of the most widely used gases is sulfur hexafluoride, SF 6 which has a relatively high electron attachment cross section for low energy (<0.05 ev) electrons, making it particularly attractive for use in Q machines, where T e ~ 0.2 ev. However, in discharge plasmas having T e ~ several ev, multiple negative ion species are also formed, including F -, which can be corrosive to vacuum system components. As an alternative, we have investigated the use of C 7 F 14 to produce negative ion plasmas, both in a Q machine and in a hot-filament, multidipole device. The maximum attachment cross-section is ~ 6 times higher than that of SF 6, and occurs at a higher energy, 0.15 ev, so that the attachment efficiency should be enhanced both in the Q machine and in the discharge plasma. Details of the experimental setup and Langmuir probe characteristics obtained in the plasma with C 7 F 14 will be presented. Work supported by the U. S. Dept. of Energy

2 NEGATIVE ION PLASMAS Negative ions are present in a number of different plasmas o plasma processing devices which utilize reactive gases such as silane (SiH 4 ) or methane (CH 4 ) o In the earth s ionosphere (O, O 2, NO 2 ) o combustion plasmas o gaseous lasers o neutral beam sources for fusion (H ) o stellar atmospheres (H ) Interest in negative ion plasmas o plasmas with m + m o shielding of low frequency fields by electrons is reduced o new wave modes appear o similar to dusty plasmas Formation of negative ion plasmas o von Goeler, Ohe and D Angelo (J. Appl. Phys. 37, 2519, 1966), bombarded the hot tungsten plate of a Q machine with an atomic beam of CsCl to form a plasma containing Cs + and Cl ions. o Douchet (Phys. Lett. 33A, 283, 1970) introduced Iodine gas into a gas discharge to produce a plasma with I ions by dissociative attachment I 2 + e I + I o Wong, Mamas and Arnush (Phys. Fluids 18, 1489, 1975) introduced SF 6 into a multidipole plasma to produce a plasma with a significant fraction of negative ions produced by the reaction SF 6 + e SF 6 o Sato (Proc. 1989 ICPP, p 79; Plasma Sources Sci. Technol. 3, 395, 1994) introduced SF 6 into a potassium Q machine to produce SF 6 negative ions by electron attachment o Song, Suszcynsky, D Angelo and Merlino (Phys. Fluids B, 1, 2316, 1989) also introduced SF 6 into a K machine to produce a negative ion plasma. The presence of negative ions was observed directly using an ion mass spectrometer (Suszcynsky, D Angelo and Merlino, Rev. Sci. Instrum. 59, 1376, 1988) o Sheehan and Rynn (Rev. Sci. Instrum. 59, 1369, 1988) discussed a variety of methods to produce negative ion plasmas with low residual electron densities. o Hiroshi Amemiya (J. Phys. D: Appl. Phys. 23, 999, 1990) provided an excellent review article discussing the use of Langmuir probes in negative ion plasmas

3 o Sato, Mieno, Hirata, Yagi, Hatakeyama and Iizuka (Phys. Plasmas 1, 3480, 1994) produced a C 60 plasma consisting of K + positive ions and C 60 negative ions by introducing Buckminsterfullerene particles into a Q machine plasma o Oohara and Hatakeyama (Phys. Rev Lett. 91, 205005, 2003) generated a pure plasma consisting of C 60 + and C 60 by electron beam impact ionization Electron Attachment Cross Sections R. K. Asundi and J. D. Craggs in their paper Electron capture and ionization phenomena in SF 6 and C 7 F 14 Proc. Phys. Soc. 83, 611, (1964), measured the cross sections for electron capture for both molecules using the retarded potential difference technique. This method provides an electron beam at a well defined energy and with an energy spread ~ 0.05 ev. The resulting cross sections are shown below.

4 Attachment cross sections for SF 6 In the energy range of 0 30 ev, mass-spectroscopic studies show that SF, SF, and F 6 5 are formed. The peak at energies near zero are due to the resonant capture of electrons by the process SF + e SF SF * 6 6 6 In the range of 4 14 ev, the predominant negative ion is F -, while at an energy of 17.3 ev, the negative ion SF appears. 5 The maximum cross section of 1.3 10-15 cm 2 is obtained at an electron energy of 0.03 ev.

5 Attachment cross sections for C 7 F 14 In the energy range of 0 30 ev, mass spectrometric studies show that seven negative ions are formed, with the most abundant being the parent negative ion CF. 7 14 The resonant peak appearing at 0.15 ev is attributed to CF in the process 7 14 CF + e CF CF * 7 14 7 14 7 14 The maximum cross section is 7.5 10-15 cm 2, occurring at 0.15 ev. Low energy electron attachment cross sections A considerable amount of experimental work has been done to measure the attachment cross sections at ultra low electron energies (0-160 mev) and with energy resolutions ~ few mev.a good deal of this work is due to Chutjian (e.g., Chutjian and Alajajian, J. Phys. B: At. Mol. Phys. 20, 839, 1987). The photoionization method was used, in which krypton gas is photoionized at threshold, generating low energy electrons with an energy width determined by the slit width of the vacuum ultraviolet monochromator. The result are shown below. These low energy results show that the cross section for attachment to SF 6 is larger than that of C 7 F 14 for energies below ~ 0.1 ev. For energies slightly above ~ 0.1 ev, the cross section for attachment to C 7 F 14 is larger by almost an order of magnitude. Low Energy Electron Attachment Corss Sections Source: Chutjian and Alajajian, J. Phys. B: At. Mol. Phys. 20, 839 (1987) C 7 F 14 SF 6 10-14 10-15 10-16 0.001 0.01 0.1 1 Energy (ev) C7F14_SF6_LowE_xSec

6 Perfluoromethylcyclohexane C 7 F 14 PROPERTIES Physical Molecular mass clear, colorless, odorless, stable liquid 350 amu Density 1.78 g/cm 3 Boiling point Vapor pressure 76 C 107 Torr @ 25 C

7 VAPOR PRESSURE of C 7 F 14 600 500 400 300 200 100 0 240 260 280 300 320 340 T (K) C 7 F 14 is a liquid at room temperature, but has a relatively high vapor pressure of ~ 100 Torr. The vapor can be leaked into a vacuum vessel in the same way as the gas SF 6.

8 Measurement of the pressure of C 7 F 14 For pressures above ~ 10-4 Torr, a capacitance manometer can be used to measure the absolute pressure of C 7 F 14 present in the vacuum chamber. For the lower pressures used in these experiments, the only available pressure measurement device was the Bayard-Alpert ionization gauge. However, the gas sensitivity factor for C 7 F 14 was not available. An estimate of the gas sensitivity factor was obtained following the suggestion by Holanda (J. Vac. Sci. Technol. 10, 1133, 1973) who showed that the relative gas sensitivity factors correlate best with the ionization cross sections of the gas in question compared to that of nitrogen, using an energy corresponding to 2/3 of the accelerating voltage of the BA tube. Using this method, the relative gas sensitivity factors for SF 6 and C 7 F 14 are found to be SF 6 : C 7 F 14 : S σ (80 ev ) / = = 2.3 (80( ev ) SF6 ionz S SF6 N2 N2 σ ionz S σ (80 ev ) / = = 6.3 (80( ev ) C7F14 ionz S C7F14 N2 N2 σ ionz The estimated value for SF 6 agrees with the published values. Admitting C 7 F 14 into the vacuum system The procedure for leaking C 7 F 14 into the vacuum system is shown schematically Fig. 1. A glass flask is used as the liquid reservoir and sealed with a rubber stopper fitted with a 0.25 polyethylene tube. This tube is then connected to the main vacuum chamber first through a coarse valve then through a needle leak valve. A connection through an additional valve to a mechanical pump is provided to initially remove any ambient air in the vacuum lines and liquid reservoir. At room temperature, the vapor pressure is sufficient to provide a constant pressure supply of C 7 F 14 molecules to the vacuum chamber. The maximum pressure of C 7 F 14 used in the system was 1 mtorr. Effect of C 7 F 14 on the vacuum vessel. We have not observed any corrosive effects on the vacuum components of the Q machine. Also, when the input of C 7 F 14 is closed, we observe that the system returns relatively quickly to the initial base pressure. This was generally no the case when C 7 F 14 was used in a hot filament discharge plasma. In that case, the energetic ionizing electrons would give rise to additional species of negative ions as well as dissociation of the molecule, resulting in the formation of corrosive fluorine compounds.

9 RESULTS Langmuir probe I-V traces for increasing amounts of SF 6

Langmuir probe I-V traces showing the reduction in the electron saturation current with increasing amounts of C 7 F 14 10

Electron probe current vs time for SF 6 and C 7 F 14 11

12 Determination of n e /n + from Langmuir probe I-V traces The densities of the positive ions, electrons and negative ions are related through the quasineutrality condition: n = n + n [1] + e Probe saturation currents: I = en v A [2] + + +,T I = en v A + en v A [3] e e, T, T where, v jt, 1 2 kt j = m j is the thermal speed of species j, with T j and m j are respectively, the temperature and mass of species j. A is the probe collection area. Define, = n / n, then from [1], n = (1 ε) n. and using these in [2] and [3] we obtain: ε e + + ε = n / n = e + 1/2 1/2 I / I ( T / T ) ( m / m + + + ) ( T / T ) ( m / m ) ( T / T ) ( m / m ) e 1/2 1/2 1/2 1/2 + + e + + [4] Expression [4] provides a method of estimating ε, from a measurement of the ratio of the negative to positive probe saturation currents I / I + To apply [4], the known positive and negative ion masses are required: o SF 6 : m + /m = 0.27 o C 7 F 14 : m + /m = 0.11 T e, T +, and T are also required in applying [4] o for the Q machine plasma T e T + 0.2 ev o The negative ions are formed by electron attachment to gas molecules at room temperature. It is expected that the negative ions will be relatively close to room temperature, or perhaps not more than a factor of (2-4) higher than room temperature, T (0.025 0.1) ev.

13 Comparison of the reduction in electron saturation currents with SF 6 and C 7 F 14 The saturation currents are normalized to the electron saturation currents before SF 6 or C 7 F 14 are introduced

14 n e /n + vs. pressure for SF 6 and C 7 F 14 Lower values of n e /n + are obtained for C 7 F 14 at lower pressures than with SF 6

15 Difference between probe floating potential, V f and plasma potential, V p vs. pressure in SF 6 and C 7 F 14 As the amount of C 7 F 14 increases, the difference between V f and V p also decreases. At some point the floating potential actually is greater than the plasma potential, V f V p > 0. This occurs because the plasma is composed of light positive ions and heavy negative ions.

16 Summary of results for C 7 F 14 As n e /n + 0, the plasma is basically a positive ion/negative ion plasma, with the positive ions as the lighter species.

17 Current-Driven Electrostatic Ion Cyclotron Waves (EIC) in a Plasma with Negative Ions Observation of current-driven EIC waves can be used as a diagnostic for the presence of the negative ion CF 7 4 EIC waves can be driven unstable by providing an electron current along the magnetic field in the plasma In a plasma composed of electrons, positive ions and negative ions, two wave modes are excited, one associated with the positive ions and one associated with the negative ion. The EIC modes occur at frequencies above the cyclotron frequency associated with the particular ion, Ω j = eb/m j The mode frequencies, ω j increase with the relative negative ion concentration, n / n +, as shown in the theoretical plot shown below. T e = T + = 0.2 ev T = 0.03 ev K = 628 m -1 K + CF 7 14

18 EXPERIMENTAL RESULTS (1)

(2) EIC mode frequencies vs. magnetic field strength 19 K + C 7 F 14 The ratios of the slopes of the f vs B lines are consistent with the proper mass rations for K + and C 7 F 14 ions.

20 SUMMARY AND CONCLUSIONS (1) Negative ion plasmas in C 7 F 14 have been formed in a K + Q machine plasma (2) Electron attachment to C 7 F 14 results in significant reductions in the electron density with relative concentrations n e /n + ~ 0.1 obtained at C 7 F 14 pressures < 10-6 Torr. (3) For C 7 F 14 pressures ~ 10-5, n e /n + < 0.001. (4) For C 7 F 14 pressures > 10-5, (V f V p ) > 0, indicating that the plasma is dominated by light positive ions and heavy negative ions (5) The presence of C 7 F 14 ions has been verified by observation of the negative ion EIC wave mode that is produced when an electron current is present along the magnetic field.