Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Similar documents
Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Pressure Measurement Single-range transmitters for general applications

ED 701 General Industry Pressure Transmitter

Pressure transmitters for industrial applications MBS 32 and MBS 33

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Pressure Transmitter ED 701

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

ISEmax CAM40/CAS40. Technical Information

EX-EMERGENCY LIGHT FITTINGS

Relative pressure transmitter type 520

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Exchangeable measuring insets SensyTemp TSA101

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

PRODUCT CATALOGUE PREssURE switch

Ex floating switches and Ex immersion probes

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

Operating Instructions for Digital Manometer. Model: MAN-SD

Field IT 50T Series Transmitters

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Z7A. Load cells. Special features. Data sheet. Wiring code

1 Overview. Pressure Measurement Transmitters for applications with basic requirements (Basic) SITRANS P310 - Technical description

ATEX/IECEx RTD temperature probe

Installation guide 862 MIT / MIR

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

Single point load cells

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Field mounted Temperature Transmitter TF212/TF212-Ex

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Cartridge Valves Technical Information. Quick reference

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

Direct-operated 2/2-way compact solenoid valves Type EV210A

PHOENIX CONTACT - 04/2016. Features

Solenoid valves 2/2-way direct-operated type EV210A

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

Switches in conformity with ATEX directive

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

Physikalisch-Technische Bundesanstalt

Reflex-Radar BM 100 A

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Type UB1 Load Cell. Option Stainless steel cable gland

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

Direct-operated 2/2-way solenoid valves Type EV210B

TH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

8 Installation Equipment

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

Non-Contact Safety Systems CMS

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

FLOW SENSOR FOR LIQUID MEDIA Serie 210

Surface-mounting Thermostats ATH Type Series

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

Full Metal Variable Area Flow Meter and Counter

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

Type M4 - SON - SO - MS

Pressure. 1 Fitting PA R - N R2

Solenoid valves Type EVUL

Ring-Torsion Load Cells RTB

maintenance-free in continuous duty low-noise space-saving extremely tough Suction capacity in m 3 /h m 3 /h 2500 Suction capacity 30,000 10,000

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Industrial Resistance Thermometers according to DIN Model MWD

5SJ4...-.HG Circuit Breakers to IEC and UL 489

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets

Technical specification FLUXUS F502TE

AC axial compact fan

Surface-mounting thermostats Series ATH

ISEmax CAS40D. Technical Information

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

Operating instructions Pressure sensor PN / / 2007

I Ex d/e Switch- and Control-Equipment I

Target Insertion Flowmeter

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

AC axial compact fan

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

Application Your benefits

Fitting PS P - B - R2

Transcription:

Overview Siemens AG 011 Function s are for measuring the liquid levels in wells, tanks, channels and dams. Diaphragm p Sensor U const. U + (brown) I EM I -1 (blue) 0, U B s are submersible sensors for hydrostatic level measurements. The s are available for various measuring ranges and with explosion protection as an option. A junction box and a cable hanger are available as accessories for simple installation. Benefits Compact design Simple installation Small error in measurement (0,3 %) Degree of protection IP68 Application s are used in the following branches for example: Oil and gas industries Shipbuilding Water supply For use in pressureless/open tanks and wells, mode of operation and wiring diagram On one side of the sensor, the diaphragm is exposed to the hydrostatic pressure which is proportional to the submersion depth. This pressure is compared with atmospheric pressure. Pressure compensation is carried out using the vent pipe in the connection cable. The hydrostatic pressure of the liquid column acts on the sensor diaphragm, and transmits the pressure to the piezo-resistive bridge in the sensor. The output voltage of the sensor is applied to the electronic circuit where it is converted into an output current of 4 to 0 ma. The cable of the 7MF1570 transmitter must always be connected in the supplied junction box. The junction box has to be installed near the measuring point. If the medium is anything other than water, it is also necessary to check compatibility with the specified materials of the transmitter. Integration Vent pipe Screen s have a front-flush piezoresistive sensor with stainless steel diaphragm. These pressure transmitters are equipped with an electronic circuit fitted together with the sensor in a stainless steel housing. The cable also contains a strength cord and vent pipe. The diaphragm is protected against external influences by a protective cap. The sensor, electronic circuit and cable are sealed in a common housing of small dimensions. The pressure transmitter is temperature-compensated for a wide temperature range. To measuredvalue processing Venting pipe Junction box 7MF1570-8AA, opened To transmitter 7MF1570 Siemens FI 01 01 /7

Siemens AG 011 Measuring point setup, in principle Technical specifications SITRANS P MPS pressure measurement transmitter (submersible Mode of operation Measuring principle piezo-resistive Input Measured variable Hydrostatic level Measuring range Maximum operating pressure 0... mh O (0... 6 fth O) 1,4 bar (0.3 psi) (corresponds to 14 mh O (4 fth O)) 0... 4 mh O (0... 1 fth O) 1,4 bar (0.3 psi) (corresponds to 14 mh O (4 fth O)) 0... 5 mh O (0... 15 fth O) 1,4 bar (0.3 psi) (corresponds to 14 mh O (4 fth O)) 0... 6 mh O (0... 18 fth O) 3,0 bar (43.5 psi) (corresponds to 30 mh O (90 fth O)) 0... 10 mh O (0... 30 fth O) 3,0 bar (43.5 psi) (corresponds to 30 mh O (90 fth O)) 0... 0 mh O (0... 60 fth O) 5,0 bar (7.5 psi) (corresponds to 50 mh O (150 fth O)) Output Output signal 4... 0 ma Measuring accuracy Acc. to IEC 60770-1 Error in measurement at limit setting 0.3 % of full-scale value (typical) incl. hysteresis and reproducibility Influence of ambient temperature Zero and span 1... 6 mh O (3... 18 fth O) 0.45 %/10 K of full-scale value 6mH O ( 18 fth O) 0.3 %/10 K of full-scale value Long-term stability Zero and span 1... 6 mh O (3...18 fth O) 0.5 % of full-scale value/year 6mH O ( 18 fth O) 0. % of full-scale value/year Rated conditions Ambient conditions Process temperature -10... +80 C (14... 176 F) Storage temperature -40... +100 C (-40... +1 F) Degree of protection to IP68 DIN EN 6059 Pressure transmitter 0.4 kg ( 0.88 lb) Cable 0.08 kg/m ( 0.054 lb/ft) Electrical connection Cable with conductors with screen and vent pipe, strength cord (max. 300 N (67.44 lbf) Material Seal diaphragm Stainless steel, mat. no. 316L/ 316 Ti Enclosure Stainless steel, mat. no. 316L/ 316 Ti Gasket Viton Connecting cable Either PE/HFFR sheath (non-halogen) or FEP sheath Power supply Terminal voltage on pressure transmitter U B 10... 33 V DC Certificates and approvals The transmitter is not subject to the pressure equipment directive (PED 97/3/EC) Explosion protection Intrinsic safety "i" TÜV 03 ATEX 004X - Marking Ex II 1 G EEx ia IIC T4 Junction box Application for connecting the transmitter cable 0. kg (0.44 lb) Electrical connection x 3-way (8 to 18 AWG) Cable entry xm0x1.5 Enclosure material polycarbonate Vent pipe for atmospheric pressure Screw for cable strength cord Rated conditions Degree of protection to IP54 DIN EN 6059 Cable hanger Application for mounting the transmitter 0.16 kg (0.35 lb) Material Galvanized steel, polyamide /8 Siemens FI 01 01

Siemens AG 011 -wire system With PE cable Measuring range Cable length L 0...mH O 10 m } 1 C 0...4mH O 10 m } 1 D 0...5mH O 5 m } 1 B 0...6mH O 5 m } 1 E 0...10mH O 5 m } 1 F 0...0mH O 5 m } 1 G 0...6ftH O 3 ft 1 K 0... 1 fth O 3 ft 1 L 0... 18 fth O 8 ft 1 M 0... 30 fth O 8 ft 1 N 0... 60 fth O 8 ft 1 P Special cable lenght/special measuring range 1) Please add -Z to Order No. and specify 9 A H.. + Y 0 1 Order code and plain text. Note: Indication of measuring range Y01 is always necessary. 3 m H 1 A 5 m H 1 B 7 m H 1 C 10 m H 1 D 15 m H 1 E 0 m H 1 F 5 m H 1 G 30 m H 1 H 40 m H 1 J 50 m H 1 K 60 m H 1 L 70 m H 1 M 80 m H 1 N 90 m H 1 P 100 m H 1 Q 15 m H 1 R 150 m H 1 S 175 m H 1 T 00 m H 1 U 5 m H 1 V 50 m H 1 W 75 m H 1 X 300 m H A 350 m H B 400 m H C 450 m H D 500 m H E 550 m H F 600 m H G 650 m H H 700 m H J 750 m H K 800 m H L 850 m H M 900 m H N 950 m H P 1000 m H Q -wire system With FEP cable Measuring range Cable length L 0...mH O 10 m } 5 C 0...4mH O 10 m } 5 D 0...5mH O 5 m } 5 B 0...6mH O 5 m } 5 E 0...10mH O 5 m } 5 F 0...0mH O 5 m } 5 G 0...6ftH O 3 ft 5 K 0... 1 fth O 3 ft 5 L 0... 18 fth O 8 ft 5 M 0... 30 fth O 8 ft 5 N 0... 60 fth O 8 ft 5 P Special cable lenght/special measuring range 1) Please add -Z to Order No. and specify 9 A H.. + Y 0 1 Order code and plain text. Note: Indication of measuring range Y01 is always necessary. 3 m H 5 A 5 m H 5 B 7 m H 5 C 10 m H 5 D 15 m H 5 E 0 m H 5 F 5 m H 5 G 30 m H 5 H 40 m H 5 J 50 m H 5 K 60 m H 5 L 70 m H 5 M 80 m H 5 N 90 m H 5 P 100 m H 5 Q 15 m H 5 R 150 m H 5 S 175 m H 5 T 00 m H 5 U 5 m H 5 V 50 m H 5 W 75 m H 5 X 300 m H 6 A 350 m H 6 B 400 m H 6 C 450 m H 6 D 500 m H 6 E 550 m H 6 F 600 m H 6 G 650 m H 6 H 700 m H 6 J 750 m H K 800 m H 6 L 850 m H 6 M 900 m H 6 N 950 m H 6 P 1000 m H 6 Q Siemens FI 01 01 /9

Siemens AG 011 -wire system Explosion protection None } 1 with type of protection "intrinsic } safety" (Ex II 1 G EEx ia IIC T4) Approvals with drinking water approval to WRAS and ACS 6 Further designs Order code Quality inspection certificate (factory C11 calibration) to IEC 60770-, add -Z to order no. and add order code. Indication of measuring range (only at Y01 special cable lengths) in... to... mh O or... to... fth O Accessories (as spare part) Order No. Junction box 7MF1570-8AA for connecting the transmitter cable Cable hanger 7MF1570-8AB for attachment of transmitter } Available ex stock Power supply units see Chap. 8 "Supplementary Components". Dimensional drawings s, dimensions in mm (inch) 79 (3.1) Protective cap Ø 7 (1.1 diam.) 158 (6.) Cable sheath + (brown) Vent pipe Strength cord (white) - (blue) Screen Cable sheath 8.3 (0.33) diam. (black or blue, PE/HFFR) Flexible cable with 0.5 mm (0.00078 inch ) cross-section Vent pipe 1 (0.04) diam. (inner diameter) Protective cap with 4 x 3 diam. (4 x 0.1 diam.) holes (black, PA) 50 (1.97) M0x1,5 Venting valve L Mounting hole 57 (.5) (0.87) 30 (1.) 94 (3.7) 1) Special measuring ranges of between 0... 1 mh O (0... 3 fth O) and 0... 00 mh O (0... 656 fth O) and special cable lengths of up to 1000 m (381 ft) are possible. With Ex versions the max. custom cable length is 50 m (150 ft). The length of free hanging cable should not exceed 375 m (130 ft). Note: Due to mounting reasons it has to be considered that the cable always must be longer than the height of the liquid column to be measured. C) Subject to export regulations AL: N, ECCN: EAR99. 65 (.56) M0x1,5 (0.87) 30 (1.) Junction box, dimensions in mm (inch) 19 (0.75) 175 (6.9) 48 (1.9) Cable hanger, dimensions in mm (inch) /30 Siemens FI 01 01

Siemens AG 011 More information Determination of the measuring range in case of media with a density 1000 kg/m3 (medium water) H ρ Calculation of the measuring range: p = ρ x g x H with: ρ = density of medium g = local acceleration due to gravity H = maximum level Example: Medium: Diesel fuel, ρ = 850 kg/m 3 Acceleration due to gravity: 9.81 m/s Start-of-scale: 0 m Maximum level: 6. m Cable length: 7 m, FEP cable Calculation: p = 850 kg/m 3 x 9.81 m/s x 6. m p = 51698.7 N/m p = 517 mbar Transmitter to be ordered: 7MF1570-9AA0-Z, H5C + Y01 Y01: 0... 517 mbar Siemens FI 01 01 /31