FIELD INSTRUMENTATION AND ANALYSIS OF PROTOTYPE AND EXISTING LIGHT POLES ON THE BRONX-WHITESTONE BRIDGE. Final Report. Ian C. Hodgson.

Similar documents
Field Instrumentation and Monitoring of Eyebars within the Southeast Anchorage of the Walt Whitman Bridge

2/23/ WIND PRESSURE FORMULA 2. PERCENT OF ALLOWABLE STRESS 3. FATIGUE DESIGN

Modal Based Fatigue Monitoring of Steel Structures

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

CHAPTER 5. 1:6-Scale Frame: Northridge Ground-Motion Modeling and Testing

Investigation of the Vibrations on Overhead Sign Bridges on US290/SH71

Response Spectrum Analysis Shock and Seismic. FEMAP & NX Nastran

Structural Dynamics Lecture Eleven: Dynamic Response of MDOF Systems: (Chapter 11) By: H. Ahmadian

Transactions on the Built Environment vol 22, 1996 WIT Press, ISSN

Chapter 3. Experimentation and Data Acquisition

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

SHAKING TABLE TEST OF STEEL FRAME STRUCTURES SUBJECTED TO NEAR-FAULT GROUND MOTIONS

Dynamics of structures

Study of Rupture Directivity in a Foam Rubber Physical Model

Fatigue Crack Analysis on the Bracket of Sanding Nozzle of CRH5 EMU Bogie

PLEASURE VESSEL VIBRATION AND NOISE FINITE ELEMENT ANALYSIS

VIBRATION MEASUREMENT OF TSING MA BRIDGE DECK UNITS DURING ERECTION

THERMOWELL VIBRATION INVESTIGATION AND ANALYSIS

Estimation of Unsteady Loading for Sting Mounted Wind Tunnel Models

Committee Draft No. 99 To be combined with T-150 as a method B. Determination of Natural Frequency and Flexural Modulus by Experimental Modal Analysis

5. What is the moment of inertia about the x - x axis of the rectangular beam shown?

Methods For Reducing Vibration (Intro to Vibration Control) Robert J. Sayer, PE President, The Vibration Institute Owner, Applied Structural Dynamics

The LAT Electronics consists of five distinct box assemblies as follows:

Grandstand Terraces. Experimental and Computational Modal Analysis. John N Karadelis

MECHANICS OF MATERIALS. Prepared by Engr. John Paul Timola

Mechatronics II Laboratory EXPERIMENT #1: FORCE AND TORQUE SENSORS DC Motor Characteristics Dynamometer, Part I

Finite Element Analysis Lecture 1. Dr./ Ahmed Nagib

Answers to examination-style questions. Answers Marks Examiner s tips

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS

Special edition paper

CHAPTER 4 DESIGN AND ANALYSIS OF CANTILEVER BEAM ELECTROSTATIC ACTUATORS

IOMAC' May Guimarães - Portugal IMPACT-SYNCHRONOUS MODAL ANALYSIS (ISMA) AN ATTEMPT TO FIND AN ALTERNATIVE

Experimental Modal Analysis of a Flat Plate Subjected To Vibration

Influence of residual stresses in the structural behavior of. tubular columns and arches. Nuno Rocha Cima Gomes

[5] Stress and Strain

Glossary Innovative Measurement Solutions

T1 T e c h n i c a l S e c t i o n

five Mechanics of Materials 1 ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture

SYSTEM IDENTIFICATION & DAMAGE ASSESSMENT OF STRUCTURES USING OPTICAL TRACKER ARRAY DATA

Monitoring based weak point determination of a steel bridge s torsional bracings with regard to fatigue threat

Basic Principle of Strain Gauge Accelerometer. Description of Strain Gauge Accelerometer

COUPLED USE OF FEA AND EMA FOR THE INVESTIGATION OF DYNAMIC BEHAVIOUR OF AN INJECTION PUMP

Evaluation of a Six-DOF Electrodynamic Shaker System

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each.

Finite Element Analysis for the Damage Detection of Light Pole Structures

ME 475 Modal Analysis of a Tapered Beam

Propagation of Uncertainty in Stress Estimation in Turbine Engine Blades

on the figure. Someone has suggested that, in terms of the degrees of freedom x1 and M. Note that if you think the given 1.2

LECTURE 12. STEADY-STATE RESPONSE DUE TO ROTATING IMBALANCE

Mechanics of Materials

Transactions on Modelling and Simulation vol 10, 1995 WIT Press, ISSN X

Program System for Machine Dynamics. Abstract. Version 5.0 November 2017

Preliminary Examination - Dynamics

LATERAL STABILITY OF BEAMS WITH ELASTIC END RESTRAINTS

NUMERICAL MODELLING OF RUBBER VIBRATION ISOLATORS

Measurement Techniques for Engineers. Motion and Vibration Measurement

Automated Estimation of an Aircraft s Center of Gravity Using Static and Dynamic Measurements

CIVL 8/7117 Chapter 12 - Structural Dynamics 1/75. To discuss the dynamics of a single-degree-of freedom springmass

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

STRAIN GAUGES YEDITEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING

Drop towers and fitness flooring assemblies

TRI-AXIAL SHAKE TABLE TEST ON THE THINNED WALL PIPING MODEL AND DAMAGE DETECTION BEFORE FAILURE

Experimental and Numerical Modal Analysis of a Compressor Mounting Bracket

Design issues of thermal induced effects and temperature dependent material properties in Abaqus

INTRODUCTION TO STRAIN

PLAT DAN CANGKANG (TKS 4219)

Design And Analysis Of Vibration Exciter

DESIGN AND APPLICATION

C100 Cryomodule Vacuum Vessel Structural Analysis An Addendum to JLAB-TN

TWISTING (TORSIONAL) STIFFNESS. Barry T. Cease Cease Industrial Consulting

Centrifuge Shaking Table Tests and FEM Analyses of RC Pile Foundation and Underground Structure

TABLE OF CONTENTS SECTION TITLE PAGE 2 PRINCIPLES OF SEISMIC ISOLATION OF BRIDGES 3

Mechanics of Materials II. Chapter III. A review of the fundamental formulation of stress, strain, and deflection

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each. Q.1 Find the force (in kn) in the member BH of the truss shown.

RESILIENT INFRASTRUCTURE June 1 4, 2016


Table of Contents. Preface...xvii. Part 1. Level

CHAPTER 4: BENDING OF BEAMS

INTRODUCTION TO PIEZO TRANSDUCERS

6. Strain Gages and Strain Measurement

Downloaded from Downloaded from / 1

ME Final Exam. PROBLEM NO. 4 Part A (2 points max.) M (x) y. z (neutral axis) beam cross-sec+on. 20 kip ft. 0.2 ft. 10 ft. 0.1 ft.

National Exams May 2016

Vibration serviceability assessment of a staircase based on moving load simulations and measurements

Address for Correspondence

October 30-31, 2014 Paris

TrueStructures TM Strain Analysis System

2.0 Theory. 2.1 Ground Vibration Test

Equilibrium in Three Dimensions

440. Simulation and implementation of a piezoelectric sensor for harmonic in-situ strain monitoring

Strain Measurement. Prof. Yu Qiao. Department of Structural Engineering, UCSD. Strain Measurement

Module I Module I: traditional test instrumentation and acquisition systems. Prof. Ramat, Stefano

APPENDIX H: HMLT FATIGUE LIFE EVALUATION. (Proposed Specification Appendix) H-1

MENG 302L Lab 6: Stress Concentration

An Analysis Technique for Vibration Reduction of Motor Pump

Bending Load & Calibration Module

2d-Laser Cantilever Anemometer

SENSORS and TRANSDUCERS

Quantification and Management of Grid Interaction Effects on Turbo- Generator Sets

Transcription:

FIELD INSTRUMENTATION AND ANALYSIS OF PROTOTYPE AND EXISTING LIGHT POLES ON THE BRONX-WHITESTONE BRIDGE Final Report by Ian C. Hodgson and Robert J. Connor ATLSS Report No. 03-17 August 2003 ATLSS is a National Center for Engineering Research on Advanced Technology for Large Structural Systems 117 ATLSS Drive Bethlehem, PA 18015-4729 Phone: (610)758-3525 www.atlss.lehigh.edu Fax: (610)758-5902 Email: inatl@lehigh.edu

Table of Contents Page 1.0 Introduction 1 2.0 Instrumentation Plan and Data Acquisition 3 2.1 Accelerometers 3 2.2 Strain Gages 3 2.3 Summary of Instrumentation 4 2.3.1 Existing Light Pole 4 2.3.2 Prototype Light Pole 6 2.4 Data Acquisition 10 3.0 Monitoring Program - Summary 11 3.1 Setup Description 11 3.2 Data Collection 11 4.0 Results of Field Monitoring and Analysis 12 4.1 Frequency of Response 12 4.1.1 Existing Lamp Pole at the Median 12 4.1.2 Prototype Lamp Pole 15 4.2 Peak Response 22 4.3 Finite Element Analysis 26 4.3.1 Prototype Lamp Pole 26 4.3.2 Proposed Lamp Pole No. 1 29 4.3.3 Proposed Lamp Pole No. 2 32 4.4 Conclusions 35 ii

1.0 Introduction This Final Report discusses and summarizes the initial results of the field testing and monitoring of the new light pole installed on the Bronx-Whitestone bridge, in New York City. A prototype light pole was installed adjacent to the prototype orthotropic deck in January 2003. It was previously decided to conduct field instrumentation of both the prototype light pole, and an existing double-mast light pole at the median in conjunction with the long-term field monitoring being performed concurrently on the orthotropic deck. The new light poles are to be installed on both sides of the bridge. The existing light poles on the median are to be removed. A photograph of the existing light pole is shown in Figure 1.1. The existing poles are approximately 25 feet in height, and are constructed of pipe vertical and horizontal pipe sections. A photograph of the prototype luminaire is shown in Figure 1.2. The pole is a 16- sided stainless steel section, with an 8 foot radius bend. The diameter ranges from 10.8 inches at the bottom to 3.18 inches at the tip. The wall thickness is constant at 0.109 inches. The luminaire is a Citea CTM manufactured by Lumec-Schreder, is located 30 feet above the roadway, and cantilevers 9 feet. According to the manufacturer s literature, the luminaire weights 60 pounds. Figure 1.1 Photograph of existing light poles at the median (view looking south) 1

Figure 1.2 Photograph of prototype light pole at southbound side of FB 63 (view looking north) 2

2.0 Instrumentation Plan and Data Acquisition The following section describes the instrumentation plan used during the field testing program. 2.1 Accelerometers Uniaxial and tri-axial accelerometers were used in the field monitoring of both the new and existing light poles. The accelerometers were manufactured by Crossbow Technology, model number CXL100HF3. They are tri-axial accelerometers with an allowable input range of ±100 g and a frequency response range of 0.3 Hz to 10,000 Hz. 2.2 Strain Gages Strain gages were installed on the prototype pole only. Six gages were located around the perimeter of the pole, 4 inches above the shaft/base weld, oriented vertically. All strain gages installed in the field were produced by Measurements Group Inc. and were 0.25 in. gage length type LWK-06-W250B-350. These are a uniaxial weldable resistance strain gage. Weldable type strain gages were selected due to ease of installation in a variety of weather conditions. The welds are a point or spot resistance weld about the size of a pin prick. The probe is powered by a battery and only touches the foil that the strain gage is mounted on by the manufacturer. This fuses a small pin size area to the steel surface. It takes forty or more of these dots to attach the gage to the steel surface. There are no arc strikes or heat affected zones that are discernible. There is no preheat or any other preparation involved other than the preparation of the local metal surface by grinding and then cleaning before the gage is attached to the component with the welding unit. There has never been an instance of adverse behavior associated with the use of weldable strain gages including their installation on extremely brittle material such as A615 Gr75 steel reinforcing bars. These gages are a temperature-compensated uniaxial strain gage and perform very well when accurate strain measurements are required over long periods of time (months to years). The gage resistance was 350Ω and an excitation voltage of 10 Volts was used. 3

2.3 Summary of Instrumentation The following section summarizes the instrumentation plan. 2.3.1 Existing Light Pole Two tri-axial accelerometers were installed on the existing double-mast light pole. One accelerometer was placed at the tip of the cantilever adjacent to the luminaire, as indicated by the red box in Figure 2.1. The orientation of the axes of the accelerometer are also shown in Figure 2.1. Tri-axial Accelerometer +z +x +y Figure 2.1 - Photograph showing location and orientation of the tri-axial accelerometer at the top of the existing median light pole. 4

A second accelerometer was placed near the base of the pole, 4-6 above the roadway surface. A photograph of this accelerometer is contained in Figure 2.2. Again, the orientation of the accelerometer is indicated in the figure. Tri-axial Accelerometer +x +z +y Figure 2.2 - Photograph of tri-axial accelerometer at the base of the existing median light pole. The accelerometer is located 4-6 above the roadway 5

2.3.2 Prototype Light Pole Two tri-axial accelerometers were installed on the prototype light pole. One accelerometer was placed at the tip of the cantilever adjacent to the luminaire, as shown in Figure 2.2. A second accelerometer was placed at the base of the pole. Two separate setups were used for the field monitoring of the prototype pole. The accelerometer at the tip of the cantilever was in place for both setups. However, at the base, the accelerometer was moved. For the first setup, the accelerometer was located 4-9 above the roadway surface as shown in Figure 2.3. For the second setup, the accelerometer was moved to the orthotropic deck, immediately below the pole connection point (see Figure 2.4). The orientation of the accelerometers at the three locations is indicated in Figures 2.2 through 2.4 +z +x +y Tri-axial Accelerometer Figure 2.2 - Photograph of tri-axial accelerometer at the top of the prototype light pole. 6

Tri-axial Accelerometer +x +y +z Figure 2.3 - Photograph of tri-axial accelerometer at the base of the existing median light pole. The accelerometer is located 4-9 above the roadway 7

Light Pole Tapered Base +z Orthotropic Deck Plate +y +x Tri-axial Accelerometer (behind) Figure 2.4 - Photograph of tri-axial accelerometer at the base of the prototype light pole. The accelerometer is mounted to a stiffened steel angle which is wrenchclamped to the orthotropic deck beneath the lamp pole 8

Furthermore, strain gages were installed at the 6, 9, 12, and 3 o clock positions on the light pole column, near the base. These gages were installed on the primary geometric axis of the light pole in order to measure primary bending stresses. In addition, two gages were installed in line with the corners of the tapered base, on the tension side of the pole. All gages were installed 4 from the pole-to-tapered-base junction. These gages were connected for the second setup only. A photograph of a strain gage mounted to the pole is contained in Figure 2.5. Strain Gage Figure 2.5 - Photograph of uniaxial strain gage mounted to the light pole, oriented vertically. (6 gages in total were installed) 9

2.4 Data Acquisition Data were collected using a Campbell Scientific CR9000 Data Logger (see Figure 2.6). This is a high speed, multi-channel, 16-bit digital data acquisition system. The sampling rate was 250Hz during all data collection. In order to ensure a stable, noise-free signal, analog and digital filtering were employed. A high-pass filter with a cutoff frequency of 50 Hz was utilized. Power was provided on the bridge. Remote communication from the ATLSS laboratories with the logger for data collection and program modifications was achieved through the use of a Cisco wireless network and high-speed internet connection. Figure 2.6 CR9000 data logger used for the light pole monitoring. The logger is mounted in a weather-tight enclosure attached to the floor beam. 10

3.0 Monitoring Program - Summary The monitoring program is summarized herein. 3.1 Setup Description As described above, two setups were used for data collection. At the prototype light pole, the first setup consisted of one accelerometer located at the tip of the cantilever and one mounted to the pole 4-9 above the roadway. For the second setup, the lower accelerometer was moved to the connection point to the orthotropic deck. The accelerometer was relocated to the base of the pole in order to more accurately measure the acceleration spectra input to the pole. Furthermore, six strain gages were installed at the base of the pole for the second setup. The instrumentation of the existing pole was the same for both setups, and consisted of one accelerometer at the tip of the west side of the double-cantilevered mast adjacent to the light, and one mounted to the pole 4-6 above the roadway. In order to assess the effect of natural wind in the area of each pole, wind speed and direction are recorded during the triggered time history events. The average angle of the wind and wind speed are also recorded every five minutes. 3.2 Data Collection Both continuous and triggered time history data were collected during both setups. For the triggered time histories, data (strain, acceleration, wind speed and direction) were collected when the acceleration at a selected accelerometer exceeds a predefined level. Data were then collected for a predefined period of time prior to and following the trigger event. Table 3.1 summarizes the data collected. Setup No. 1 Setup No. 2 File Trigger Total Sample Start End Directory Length Length Rate* Time Time (sec) (sec) (Hz) /Mar 18/ END_ACC00.DAT 123.8 123.8 250 3/18/2003 12:42 3/18/2003 12:44 END_ACC01.DAT 10 228.3 250 3/18/2003 13:12 3/18/2003 13:43 MID_ACC00.DAT 123.8 123.8 250 3/18/2003 12:42 3/18/2003 12:44 /Mar 19/ END_ACC00.DAT 10 3574.6 250 3/18/2003 18:06 3/19/2003 7:50 MID_ACC00.DAT 10 9064.1 250 3/18/2003 17:57 3/19/2003 7:51 /Mar 20/ EDGE00.DAT 8 568.6 250 3/19/2003 17:42 3/20/2003 8:09 MEDIAN00.DAT 8 478.0 250 3/19/2003 17:43 3/20/2003 7:54 /Mar 28/ EDGE00.DAT 8 5704.8 250 3/20/2003 15:10 3/28/2003 11:48 MEDIAN00.DAT 8 1347.6 250 3/20/2003 15:02 3/28/2003 7:20 /Mar 31/ EDGE00.DAT 6 120.2 250 3/28/2003 17:22 3/31/2003 7:56 MEDIAN00.DAT 6 354.5 250 3/28/2003 17:28 3/31/2003 7:30 /April 4/ EDGE.DAT 6 432.6 250 3/31/2003 10:03 4/4/2003 8:45 MEDIAN.DAT 6 839.2 250 3/31/2003 10:12 4/4/2003 6:44 /April 8/ EDGE.DAT 6 324.4 250 4/4/2003 9:50 4/8/2003 8:41 MEDIAN.DAT 6 300.4 250 4/4/2003 9:37 4/8/2003 7:10 Table 3.1 - Summary of data collected at Bronx Whitestone prototype and existing light poles *Filter cutoff frequency of 50 Hz was used 11

4.0 Results of Field Monitoring and Analysis The results of the field monitoring and finite element analysis are discussed in this section. The results for each pole will be presented separately and then compared. 4.1 Frequency of Response In order to assess the frequency response characteristics of the two poles, Fast Fourier Transforms (FFT) of selected data were created. Ten time history records were selected from the triggered data for each pole during setup #1, and for the prototype pole during setup #2, for a total of 30 time histories. Each time history consists of 1024 records, for a total of 4.096 seconds at 250 Hz. Each record represents a typical vibration event when the acceleration at the tip of the pole exceeded the predefined trigger level. Typically, these events lasted on the order of four seconds Note that the number of records is a power of two as required by the FFT algorithm. This yields a frequency increment of 0.244 Hz. For each channel of data, the average amplitude at each frequency of the ten records was calculated. Using the results of these data, the fundamental frequencies of vibration and the magnitude of the vibration can be determined. The results are presented below. In all cases, vertical, transverse, and longitudinal vibration is referenced to bridge directions. 4.1.1 Existing Lamp Pole at the Median Figures 4.1 and 4.2 contain the average FFT plots of 10 time history records from setup #1, at the top and bottom of the pole, respectively. Figures 4.1a and 4.2a contain the acceleration spectra, while Figures 4.1b and 4.2b contain the displacement spectra. The displacement spectra is obtained by dividing each acceleration amplitude by 4π 2 f 2. It can be seen that the response at the tip of the pole is dominated by vertical response. Furthermore, the pole vibrates predominately at frequencies less than 70 Hz. Each peak on the curve represents a different mode of vibration. 12

0.08 12.2 Amplitude (g) 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 0 10 20 30 40 50 60 70 80 Frequency (Hz) Top Long Top Vert Top Trans Figure 4.1a Average FFT of acceleration response at tip of existing median light pole 1.E+00 28.6 30.8 48.0 16.4 1.7 1.E-01 Displacement (in) 1.E-02 1.E-03 1.E-04 1.E-05 1.E-06 1.E-07 1.E-08 0.1 1 10 100 1000 Frequency (Hz) Top Long Top Vert Top Trans Figure 4.1b Average of displacement response at tip of existing median light pole 13

The response at the accelerometer located 4-6 above the roadway is shown in Figures 4.2a and 4.2b. It can be seen that the vibration magnitude is significantly smaller at the base of the pole. However, the same dominant frequencies are present. The band of response is wider at the base due to the proximity to the attachment point to the bridge. Amplitude (g) 0.02 0.018 0.016 0.014 0.012 0.01 0.008 0.006 0.004 0.002 0 28.6 16.4 11.7 48.0 0 20 40 60 80 100 120 140 Frequency (Hz) Bot Long Bot Vert Bot Trans Figure 4.2a Average FFT of acceleration response at base of existing median light pole, 4-6 above roadway 1.E+00 1.E-01 Displacement (in) 1.E-02 1.E-03 1.E-04 1.E-05 1.E-06 1.E-07 1.E-08 0.1 1 10 100 1000 Frequency (Hz) Top Long Top Vert Top Trans Figure 4.2b Average FFT of displacement response at base of existing median light pole, 4-6 above roadway 14

4.1.2 Prototype Lamp Pole Figures 4.3 and 4.4 contain the average FFT plots of 10 time history records for the accelerometer at the tip of the cantilever and 4-9 above the roadway, respectively. Figures 4.3a and 4.4a contain the acceleration spectra, while Figures 4.3b and 4.4b contain the displacement spectra. From Figure 4.3, it can be seen that the response of the pole is generally less than 50 Hz. From the directions of the vibrations, knowing the geometry of the pole, and examining the frequencies and magnitudes in the FFT response, general conclusions can be drawn about the mode shapes that each peak represents. There are two primary modes of vibration, with additional harmonic modes of each. The first mode is a transverse vibration mode, or hatcheting mode. The second mode is a longitudinal or torsional mode. In this mode, the column is loaded in torsion. The hatcheting modes are dominated by vertical and transverse response at the tip of the cantilever, while the torsional modes are dominated by longitudinal response at the tip of the cantilever. Given this it can be seen that pairs of hatcheting and torsional modes are present in the frequency plot. For example, the lowest hatcheting mode has a frequency of 4.4 Hz, while the lowest torsional mode has a frequency of 1.7 Hz. The second modes are closely spaced at 14.4 and 14.9, for the hatcheting and torsional modes, respectively. The FFT indicates that the acceleration response at the tip of the light pole of the light pole is dominated by the third hatcheting and torsional modes of vibration (f=14.4 and 14.9, respectively). Amplitude (g) 0.14 0.12 0.1 0.08 0.06 0.04 1.7 4.4 14.4 14.9 23.7 28.6 44.8 0.02 0 0 10 20 30 40 50 60 70 80 Frequency (Hz) Top Long Top Vert Top Trans Figure 4.3a Average FFT of acceleration response at tip of cantilever of prototype light pole 15

1.00E+00 1.00E-01 Displacement (in) 1.00E-02 1.00E-03 1.00E-04 1.00E-05 1.00E-06 1.00E-07 1.00E-08 0.1 1 10 100 1000 Frequency (Hz) Top Long Top Vert Top Trans Figure 4.3b Average FFT of displacement response at tip of cantilever of prototype light pole 16

Figure 4.4 contains the average FFT of the accelerometer located 4-9 above the roadway. It can be seen from this plot that the same peak response frequencies are present at this location. However, several higher modes are evident. Additionally, the magnitude of response is significantly less. It can also be noted that the 4.4 Hz mode is absent from this figure. This could be due to the fact that the accelerometer may be located near a nodal point for that mode. 0.018 0.016 14.9 14.4 0.014 28.6 Amplitude (g) 0.012 0.01 0.008 0.006 1.7 23.7 39.8 43.9 71.8 67.9 0.004 0.002 0 0 10 20 30 40 50 60 70 80 Frequency (Hz) Bot Long Bot Vert Bot Trans Figure 4.4a Average FFT of acceleration response at base of prototype light pole, 4-9 above roadway 17

1.00E+00 1.00E-01 Displacement (in) 1.00E-02 1.00E-03 1.00E-04 1.00E-05 1.00E-06 1.00E-07 1.00E-08 0.1 1 10 100 1000 Frequency (Hz) Bot Long Bot Vert Bot Trans Figure 4.4b Average FFT of displacement response at base of prototype light pole, 4-9 above roadway 18

Figure 4.5 shows the average FFT for the accelerometer mounted to the orthotropic deck directly below the connection to the lamp pole. Figure 4.5a contains the acceleration spectra, while Figures 4.5b contains the displacement spectra. This data was from setup #2 as described in Section 3. It can be seen that the dominant frequencies of response at this location do not match those measured on the pole. These frequencies represent the vibration of the bridge itself and is the vibration that is input to the pole. 0.014 12.0 Amplitude (g) 0.012 0.01 0.008 0.006 0.004 0.002 2.2 50.0 0 0 20 40 60 80 100 120 140 Frequency (Hz) Bot Long Bot Vert Bot Trans Figure 4.5a Average FFT of acceleration response at base of prototype light pole, at connection point to orthotropic deck 19

1.00E+00 1.00E-01 Displacement (in) 1.00E-02 1.00E-03 1.00E-04 1.00E-05 1.00E-06 1.00E-07 1.00E-08 0.1 1 10 100 1000 Frequency (Hz) Bot Long Bot Vert Bot Trans Figure 4.5b Average FFT of displacement response at base of prototype light pole, at connection point to orthotropic deck As described in Section 3, strain gages were added to the prototype pole. Figure 4.6 contains the average FFT plots for the six strain gages. As shown in Figure 4.6(a), gages 2 and 4 exhibit peak responses for the torsional modes, while gages 1 and 3 exhibit peak response for the hatcheting modes. Furthermore, maximum strain amplitudes are caused by the first mode response. Strain gages 5 and 6 are plotted in Figure 4.6(b). Since these gages are located on the 10 and 2 o clock positions of the pole base, they measure strain caused by both hatcheting and torsional modes. This is confirmed in the figure, as the response at both gages peaks at all frequencies. 20

0.35 0.3 1.7 Amplitude (ksi) 0.25 0.2 0.15 0.1 4.4 5.6 14.4 14.9 Mast dir CH_1 CH_2 CH_4 CH_3 0.05 0 0 5 10 15 20 25 30 35 40 Frequency (Hz) CH_1 CH_2 CH_3 CH_4 (a) Gages 1 through 4 0.35 1.7 0.3 Amplitude (ksi) 0.25 0.2 0.15 0.1 4.6 5.6 14.2 14.9 Mast dir CH_5 CH_6 0.05 0 0 5 10 15 20 25 30 35 40 Frequency (Hz) CH_5 CH_6 (b) Gages 5 & 6 Figure 4.6 Average FFT of vertical strain response at base of prototype light pole, 4 inches above the connection to the tapered base 21

4.2 Peak Response In the following section, a summary of the peak observed response in both the median and prototype lamp poles is given. Peak accelerations at both poles are given in Table 4.1. Peak stresses measured in the prototype pole are summarized in Table 4.2. It can be seen from Table 4.1 that at the base of the poles (4-9 above the deck for the prototype and 4-6 above for the existing), the accelerations are similar, however, the direction of maximum acceleration varies. At the median, peak accelerations at the base occur in the transverse and longitudinal directions (0.41 g and 0.52 g respectively), while at the prototype pole, the peak acceleration occurs in the vertical direction (0.24 g). The peak acceleration at the tip of the median pole occurred in the vertical direction (1.64g). At the prototype pole, peak accelerations occurred in both the vertical and longitudinal directions (1.42 g and 1.44 g respectively). Top Top Top Bottom Bottom Bottom Transverse Longitudinal Vertical Transverse Longitudinal Vertical (g) (g) (g) (g) (g) (g) Median 0.41 0.61 1.64 0.41 0.52 0.10 Prototype 0.44 1.44 1.42 0.11 0.11 0.24 Prototype @ Bottom - - - 0.06 0.12 0.26 Table 4.1 Summary of peak observed accelerations at both light poles Table 4.2 shows the peak measured stresses in the light pole near the base. Typical strain time-history plots are presented in Figure 4.7. σ 1 σ 2 σ 3 σ 4 σ 5 σ 6 (ksi) (ksi) (ksi) (ksi) (ksi) (ksi) 1.42 1.20 0.92 0.85 1.20 2.20 Table 4.2 Summary of peak observed stresses at the prototype light pole 22

CH_1 CH_3 stress (ksi) CH_2 CH_4 stress (ksi) CH_5 CH_6 stress (ksi) Mast dir CH_1 CH_2 CH_5 CH_3 CH_4 CH_6 Figure 4.7 Typical strain time-history plots for the six strain sensors mounted near the base of the prototype light pole 23

Each of the ten acceleration time-history records selected were numerically integrated twice (using the trapezoid rule) to determine displacement time-histories. The mean, standard deviation, coefficient of variation, and peak value of the peak displacement of these histories for each orthogonal direction (relative to bridge directions) were determined and are presented in Table 4.3. It can be seen that the maximum displacement amplitude was 0.81 inches in the longitudinal direction at the prototype pole. Note that this does not represent the maximum for the entire monitoring period since only the ten selected acceleration records were integrated. Furthermore, these displacements were determined using numerical integration and were not directly measured. Sensor Standard Location Direction Mean Deviation COV Maximum (in) (in) (in) Median Pole Transverse 0.18 0.07 0.42 0.30 Top Longitudinal 0.10 0.04 0.39 0.16 Vertical 0.09 0.03 0.32 0.13 Median Pole Transverse 0.04 0.01 0.26 0.05 Bottom Longitudinal 0.03 0.01 0.24 0.04 (4'-6" above) Vertical 0.05 0.01 0.27 0.08 Edge Pole Transverse 0.22 0.09 0.41 0.40 Top Longitudinal 0.37 0.20 0.53 0.81 Vertical 0.23 0.08 0.36 0.36 Edge Pole Transverse 0.03 0.01 0.37 0.06 Bottom Longitudinal 0.08 0.04 0.47 0.14 (4'-9" above) Vertical 0.05 0.01 0.24 0.07 Edge Pole Transverse 0.03 0.01 0.35 0.05 Base Longitudinal 0.03 0.01 0.22 0.05 (@ deck level) Vertical 0.06 0.02 0.31 0.09 Table 4.3 Summary of peak displacements determined by integration of ten measured acceleration time-history records 24

Peak and average wind speed were recorded every 5 minutes for the duration of the monitoring period. These data were reduced to determine the average and peak daily values, which are presented in Table 4.4. It can be seen that the site consistently experiences peak daily wind speeds of over 30 mph. However, the data appear to indicate that the response of the pole is dominated by traffic induced excitation, since maximum accelerations were observed during periods of both high and low wind speed. Peak Average Date Wind Speed Wind Speed (mph) (mph) 3/19/2003 25.2 8.8 3/20/2003 34.2 11.7 3/21/2003 35.7 7.9 3/22/2003 29.2 11.2 3/23/2003 27.8 9.9 3/24/2003 19.9 6.0 3/25/2003 23.7 10.2 3/26/2003 32.7 5.1 3/27/2003 25.4 7.0 3/28/2003 21.7 4.9 3/29/2003 42.3 12.0 3/30/2003 37.5 11.2 3/31/2003 37.9 14.6 4/1/2003 30.5 8.5 4/2/2003 32.7 6.4 4/3/2003 23.5 8.9 4/4/2003 30.7 11.9 4/5/2003 27.8 8.3 4/6/2003 37.0 12.2 4/7/2003 42.5 15.4 4/8/2003 39.9 17.2 Table 4.4 Summary of daily peak and average wind speeds recorded during monitoring period 25

4.3 Finite Element Analysis The modal frequencies of a lamp pole can be estimated using a computer analysis. Models of both the prototype lamp pole (9 cantilever) and the two proposed lamp pole designs (4 cantilever with two different configurations) were created using the ABAQUS finite element code. 4.3.1 Prototype Lamp Pole Figure 4.8 contains the undeformed view of the prototype lamp pole model. The pole is modeled using beam elements with varying section properties to represent the tapered section. The luminaire is modeled as a point mass with rigid constraints to connect it to the model. The mode shapes and frequencies are extracted using ABAQUS. Figure 4.9 (a) through (d) contain the mode shapes and frequencies of the four lowest modes as determined by analysis. It can be seen that these modes agree with the test data presented in Section 4.2. All modes are either a harmonic of the hatcheting (transverse & vertical) mode or torsional (longitudinal) mode. For example, mode 3 of Figure 4.9(c) is a harmonic of the hatcheting mode (the 2nd harmonic). Mode 4 (Figure 4.9(d)) is the 2nd harmonic of the torsional mode. This can be further demonstrated by looking at Table 4.3 which shows that the modes exist in closely spaced pairs. Each pair consists of a harmonic of both the hatcheting and torsional mode. Table 4.5 presents a summary of the modal frequencies for the first ten modes, and the participation factors for the three principal directions. It can be seen from this table that the vertical and transverse or hatcheting vibration modes are excited by base motion in both the transverse and vertical direction, as expected. However, longitudinal or torsional vibration modes are excited by longitudinal bridge motion only. 26

W = 60 lb Figure 4.8 ABAQUS model of the prototype pole. The luminaire is modeled as a point mass of 60 lb. (a) f=1.79 Hz (b) f= 1.91 Hz Figure 4.9 Lowest four modes of vibration for the prototype pole as determined by ABAQUS. The undeformed pole is shown in blue 27

(c) f = 4.82 Hz (d) f= 5.85 Hz Figure 4.9 cont d Lowest four modes of vibration for the prototype pole as determined by ABAQUS. The undeformed pole is shown in blue X Y Z Mode Freq. Component Component Component No. (Hz) (Trans) (Vert) (Long) 1 1.79 0.000 0.000 1.338 2 1.91 0.856-0.418 0.000 3 4.82 0.932 0.665 0.000 4 5.85 0.000 0.000 0.810 5 17.06 0.582 0.007 0.000 6 17.74 0.000 0.000-0.751 7 35.84-0.578 0.273 0.000 8 35.86 0.000 0.000 0.593 9 62.55 0.000 0.000-0.504 10 62.82 0.5295 0.094 0.000 Table 4.5 Summary of modal frequencies and participation factors for the prototype (9 cantilever) light pole analysis 28

4.3.2 Proposed Lamp Pole No. 1 Figure 4.10 contains the undeformed view of the prototype lamp pole model (4 cantilever). This pole is similar to the prototype pole. A similar 16-sided tapered pipe section is used for the pole. However, the base of the pole is welded directly to the baseplate (the prototype pole had a tapered base). Furthermore, the cantilever over the roadway is only 4. The luminaire is 30 above the roadway. The pole is modeled using beam elements with varying section properties to represent the tapered section. The luminaire is modeled as a point mass with rigid constraints to connect it to the model. Figure 4.11 (a) through (d) contain the mode shapes and frequencies of the four lowest modes as determined by analysis. The general behavior of this pole is similar to the prototype pole, however the vibration frequencies are different. Since we do not have measured data for this pole, further analysis is required to estimate the behavior of this pole. However, in order to avoid potential vibration problems, it is desirable that the natural frequencies of pole not match those of the bridge at the connection point. It can be assumed that the vibration of the bridge is unaffected by the presence of the light pole. Therefore, the vibration measured at the base of the prototype pole can be used to estimate the input spectra. This is contained in Figure 4.5. From this figure, it can be seen that the frequencies of the light pole that should not fall within a frequency range of 10 to 15 Hz, particularly those which are excited by vertical excitation. An additional frequency to avoid is 2 Hz vertically since this is also predominant frequency of vibration of the bridge. Resonance can occur if the natural frequencies of the light pole coincide with those of the bridge. Table 4.6 presents a summary of the modal frequencies for the first ten modes, and the participation factors for the three principal directions. Again, the behavior is similar to the prototype pole. It appears that the pole does not have vibration frequencies in the range of 10 to 15 Hz, however, there is inherent uncertainty in such an analysis and therefore the design should be further studied to preclude detrimental vibration. Mode 2 appears to match the vertical 2 Hz vibration measured at the base of the pole. To move the pole off this peak, either the luminaire mass can be decreased, or the pole can be stiffened. 29

W = 35 lb Figure 4.10 ABAQUS model of the proposed pole No. 1 (4 cantilever). The luminaire is modeled as a point mass of 35 lb. 30

(a) f = 2.31 Hz (b) f = 2.36 Hz (c) f = 7.41 Hz (d) f = 7.68 Hz Figure 4.11 Lowest four modes of vibration for the proposed pole No. 1 as determined by ABAQUS. The undeformed pole is shown in blue 31

X Y Z Mode Freq. Component Component Component No. (Hz) (Trans) (Vert) (Long) 1 2.31 0.000 0.000 1.446 2 2.36 1.266-0.203 0.000 3 7.41 0.882 0.752 0.000 4 7.68 0.000 0.000-0.641 5 16.55 0.545-0.231 0.000 6 17.19 0.000 0.000-0.857 7 37.98-0.505-0.056 0.000 8 38.71 0.000 0.000 0.582 9 68.70 0.380 0.086 0.000 10 69.03 0.000 0.000-0.475 Table 4.6 Summary of modal frequencies and participation factors for the proposed light pole No 1 analysis 4.3.3 Proposed Lamp Pole No. 2 In order to preclude the possibility of resonant response, due to the fact that the dominant frequency of vibration of the proposed lamp pole No. 1 is close to that of the bridge supporting it, the pole was redesigned with a larger diameter tube. The pole consists of a hexdecagonal (as before) straight shaft with a outer diameter varying from 14 1/2 inches at the base to 5 1/4 inches at the top, and a constant wall thickness of 1/4 inches. The mast is a 4 foot 7 1/2 inch 11 gage pipe section with an outer diameter varying from 3.42 inches at the pole to 2.86 inches at the tip. The luminaire weight was kept the same at 35 pounds. An undeformed view of the finite element model of proposed lamp pole No. 2 is shown in Figure 4.12. An elastomeric laminated fabric pad (Fabreeka brand) is to be installed between the lamp pole base plate and the orthotropic deck. It should be noted that the use of the pad will likely degrade the fatigue performance of the bolts used to secure the pole to the deck. This pad is designed to dampen shock and vibration. However, it will make the system slightly more flexible. This was taken into account through the use of two rotational springs added to the model that act about the longitudinal and transverse axes (see Figure 4.12). The stiffness of these springs was determined to be 163,600 k-in/rad using hand calculations. Figure 4.13(a) through (d) contains the mode shapes and frequencies of the four lowest modes as determined by analysis. The general behavior of this pole is similar to the prototype pole, however the vibration frequencies are different. Table 4.7 presents a summary of the modal frequencies for the first ten modes, and the participation factors for the three principal directions. Again, the behavior is similar to the prototype pole. The primary vibration frequencies (modes 1 and 2) have been raised from the 2 Hz range to 3.3 Hz. This is beneficial as these frequencies are separated from the primary vibration frequency of the bridge which is in the 2 Hz range. Furthermore, there are no modes with frequencies of between 10 and 15 Hz, which is also desirable. 32

It should be noted that these analysis are simply modal analyses and therefore do not account for any damping in the system. Modal analysis does not provide any predicted magnitude of response. It does provide the displaced shape of the primary modes of response, and the frequencies of these modes. In order to predict the magnitude of response to a given excitation, time-history analysis can be performed. The additional structural damping provided by the Fabreeka pad, though not accounted for in these analyses, will certainly improve the vibration response of the pole, since these poles possess little structural damping. W = 35 lb k θx k θz Figure 4.12 ABAQUS model of proposed pole No. 2 (4-7 cantilever). The luminaire is modeled as a point mass of 35 lb. 33

(a) f = 3.34 Hz (b) f = 3.38 Hz (c) f = 8.77 Hz (d) f = 8.83 Hz Figure 4.13 Lowest four modes of vibration for proposed pole No. 2 as determined by ABAQUS. The undeformed pole is shown in blue 34

X Y Z Mode Freq. Component Component Component No. (Hz) (Trans) (Vert) (Long) 1 3.34 0.000 0.000 1.730 2 3.38 1.554-0.092 0.000 3 8.77 0.000 0.000-0.805 4 8.83 0.828 0.673 0.000 5 16.46-0.746 0.119 0.000 6 18.10 0.000 0.000-1.138 7 40.17-0.473-0.016 0.000 8 43.12 0.000 0.000 0.718 9 76.92 0.405 0.039 0.000 10 79.28 0.000 0.000-0.743 Table 4.7 Summary of modal frequencies and participation factors for the proposed light pole No. 2 analysis 4.4 Conclusions The following conclusions can be drawn from the results presented above. 1. The vibrations at the base of the existing light pole (4-6 above the roadway) and the base of the prototype light pole (4-9 above the roadway) are comparable. 2. Peak accelerations as the base of the median pole were on the order of 0.5 g longitudinally. 3. Peak accelerations at the base of the prototype pole were on the order of 0.25 g vertically. 4. Peak accelerations at the tip of the median pole were on the order of 1.6 g vertically. 5. Peak accelerations at the tip of the prototype pole were on the order of 1.4 g vertically and longitudinally. 6. The third hatcheting and torsional modes of the prototype pole appear to produce the highest accelerations at the luminaire. 7. Maximum measured stress in the prototype pole was 2.2 ksi. 8. Peak displacements determined numerically from the 10 selected acceleration records were 0.81 inches longitudinally for the prototype pole and 0.3 inches transversely for the median pole. 9. Vibration of the poles appears to be dominated by traffic induced excitation. 10. Proposed poles should avoid natural frequencies in the 2-2.5 Hz and 10-15 Hz ranges. 11. Proposed light pole No. 1 had some vibration modes that may match those of the bridge. 12. Proposed light pole No. 2 appears to have vibration modes which are separated from those of the bridge. 35