Periodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018

Similar documents
University of Moratuwa, Sri Lanka. EE3231: Design of Electrical Installation

F F FAULT CURRENT Prospective. 1. Introduction. 2. Types of fault conditions

16 Appendix 16 Electrical Research Association Report

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Alternating Current (AC): Alternating Current is electric current that reverses directions at regular intervals.

TeSys circuit-breakers

Installation guide 862 MIT / MIR

User Manual VX4750 Function Generator Module

Film Capacitors. EMI suppression capacitors. Date: June 2018

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

Electrical installation solutions for buildings Technical details Arc Fault Detection Devices

THF / 1SCC330001M THF 1S1 C

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Electrical safety testing Checklist

EXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

5SJ4...-.HG Circuit Breakers to IEC and UL 489

ELECTRICAL INSTALLATION CONDITION REPORT: 6297

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Operating Instructions for Digital Manometer. Model: MAN-SD

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

TECHNICAL INFORMATION

Fault Calculation Methods

An Introduction to Insulation Resistance Testing

Thermal-Magnetic Circuit Breaker 2210-T2...

QUALIFICATION SPECIFICATION

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Data Bulletin. SEPAM 49RMS Application Note Protection for Motor Applications Class Number SEPAM 49RMS Protection for Motor Applications

CERTIFICATE OF CALIBRATION

Sealing possibility Electrical endurance (ops) Mechanical endurance (ops) Overvoltage category Standards

UL 1077 DIN Rail Supplementary Protectors

Kingspan Smart-Lite Kite Luminaire

GENERATOR INTERCONNECTION APPLICATION

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

PHOENIX CONTACT - 04/2016. Features

Lamp and Control Panel (Lamp Panel)

PUB NLH 185 Island Interconnected System Supply Issues and Power Outages Page 1 of 9

DC/DC regulator Input V Output up to 16 A

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

TEST REPORT IEC/EN Circuit-breakers for over current protection for household and similar installations

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

EPR Insulated, Heavy Duty HOFR Sheathed Flexible Cables

Non-Contact Safety Systems CMS

Report No 247/ This Report consists of 41 pages

Quarries National Joint Advisory Committee (QNJAC) Occupational Health. Information Sheet 10. April Management of Asbestos on Site

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

AN78xx/AN78xxF Series

90 MCB range Modular circuit breakers for circuit protection

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

What is a short circuit?

08/072 PKZ2 Motor-Protective Circuit-Breakers Tripping Characteristics

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

VK2 volume flow controller Overview

Current protection I 2 t long-time protection

Single Phase Motors Technical Datasheets

DC/DC converter Input 9-36 and Vdc Output up to 0.5A/3W

TeSys enclosed starters 2

Masterpact. Installation recommendations

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

S R O T C U D IN & MYRRA

Installation Manual. Installation manual for PerfectEnergy Solar Modules. Content

Recommended Land Pattern: [mm]

TEST REPORT IEC :2002 Circuit-Breakers for overcorrect protection for household and similar installation

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

N-channel TrenchMOS logic level FET

POWER FACTOR IN THE DIGITAL AGE A N E N V I R O N M E N T A L P O T E N T I A L S W H I T E P A P E R. Power Quality For The Digital Age

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

SCM Series Supercapacitor Modules Series-Connected Supercapacitors

Non-licensed Work with Asbestos Training

SWITCHGEAR: design concepts, testing, standards and safety of persons and installations

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka

Requirements to perform accurate dielectric material analysis

P402 - Surveying and Sampling Strategies for Asbestos in Buildings

PSMN004-60B. N-channel TrenchMOS SiliconMAX standard level FET. High frequency computer motherboard DC-to-DC convertors

Test Report issued under the responsibility of: SHA-001 Date of issue... : Total number of pages... : 292. Report Number...

Eppendorf BioSpectrometer 6135/6136/6137

Electroscope Used to are transferred to the and Foil becomes and

Maintenance/ Discontinued

Issued August DATA SHEET. 3VT5 MCCB up to 1600 A

DATA SHEET POSITIVE TEMPERATURE COEFFICIENT AC/DC POWER SUPPLY SMD0603 series

SolderSleeve Devices Specification For Commercial Wire Splices. Table of Contents

Coimisiún na Scrúduithe Stáit State Examinations Commission

Physics (2) Laboratory manual

PSMN005-75B. N-channel TrenchMOS SiliconMAX standard level FET. High frequency computer motherboard DC-to-DC convertors

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT.LTD.

General characteristics, Products

PHASED OUT. LED light engines LED linear / area. Module CLE Quadrant G2 ADV Modules CLE ADVANCED

LED light engines LED linear / area. Module CLE Quadrant G3 ADV Modules CLE ADVANCED

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Transcription:

Periodic Inspection and Testing of Electrical Installations Sample Test (2391-051) Version 1.3 July 2018 Sample Questions

Version and date Change detail Section 1.3 July 2018 Modified questions/answers to suit BS 7671:2018 All Candidate Name Date DD/MM/YY 1 What would be the correct procedure to confirm that the existing electrical installation in a dwelling is suitable for the additional wiring of an extension? a) A visual inspection of the wiring and condition of the accessories. b) A full review of the original electrical installation certificate. c) Certification of the additional wiring on completion of the extension. d) A periodic inspection and test of the existing installation. 2 What is the purpose of a periodic inspection and test relating to the safety of the building? a) There is no risk of electric shock and burns. b) There is no risk of fire caused by the electrical installation. c) That the electrical installation is not damaged. d) That there are no defects or non-compliances present. Sample Questions 2

3 What is the minimum level of IP protection for the opening shown as Item A in Figure 1? a) IP4X b) IPX4 c) IP2X d) IPX2 4 What is the minimum level of IP protection for the accessible top surface of a consumer unit? a) IP4X b) IPX4 c) IP2X d) IPX2 5 Which publication gives detailed information for carrying out testing of electrical installations? a) HSE GS 38 b) IET Guidance Note 3 c) IET Guidance note 1 d) HS(G)141 Sample Questions 3

6 What would be agreed with the client and recorded as a limitation for a periodic inspection and test? a) No insulation resistance testing between live conductors to be carried out. b) The installation can be isolated and a full range of tests to be carried out. c) The finalised report is to be provided to the client electronically. d) Only calibrated test instruments are to be used. 7 Which statutory document includes the requirements for working on live conductors? a) The Electricity Safety Quality and Continuity Regulations. b) The Construction (Design and Management) Regulations. c) The Health and Safety at Work Act. d) The Electricity at Work Regulations. 8 What action should the inspector take, both before and after testing, to confirm isolation of the supply? a) Switch the main isolator on and off. b) Lock the main switch on the open position. c) Confirm the operation of the approved voltage indicator. d) Attach a warning label at the isolator stating do not switch on. 9 Questions 9 to 11 relate to the following scenario. An inspection is to be carried out at the termination of the circuit conductors inside a terminal box, as shown in Figure 2. Sample Questions 4

Which human sense is best used to confirm the terminals are suitably tightened? a) Touch. b) Sight. c) Smell. d) Hearing. 10 Questions 9 to 11 relate to the following scenario. An inspection is to be carried out at the termination of the circuit conductors inside a terminal box, as shown in Figure 2. What is confirmed when inspecting the conductor insulation? a) Suitable csa. b) Correctly identified. c) Terminals are tight. d) Contained in the terminals. Sample Questions 5

11 Questions 9 to 11 relate to the following scenario. An inspection is to be carried out at the termination of the circuit conductors inside a terminal box, as shown in Figure 2. Which classification code would be given on the Schedule of Inspections for the situation shown in Figure 3? a) C1 b) C2 c) N/V d) FI 12 Which classification code indicates that there is a non-compliance which is identified as improvement recommended? Sample Questions 6

a) C1 b) C2 c) C3 d) FI 13 Which human senses would be best used to determine excess arcing at a contactor during a walk around survey? a) Touch and smell. b) Sight and hearing. c) Smell and sight. d) Hearing and smell. 14 Questions 14 to 17 relate to the following scenario. A test is to be carried out to confirm the continuity of the main protective bonding conductor to the metallic water installation pipework in a commercial premises. What is the risk if the installation is not safely isolated for this test? a) Poor performance of connected equipment. b) Electric shock from different potentials. c) Possible loss of computer data. d) Tripping hazards from the test method. 15 Questions 14 to 17 relate to the following scenario. A test is to be carried out to confirm the continuity of the main protective bonding conductor to the metallic water installation pipework in a commercial premises. What is the purpose of the test of continuity of main protective bonding conductors? a) To confirm extraneous conductive parts are connected to the MET. b) To confirm there is a low earth return path for fault current. c) To confirm exposed conductive parts are connected to the MET. d) To confirm that a high current will flow in the event of an earth fault. Sample Questions 7

16 Questions 14 to 17 relate to the following scenario. A test is to be carried out to confirm the continuity of the main protective bonding conductor to the metallic water installation pipework in a commercial premises. What important check must be made with the instrument leads before a reading is taken? a) Leads have a 3 mm exposed tip. b) Leads are a minimum 10 mm 2. c) Leads are nulled or zeroed. d) Leads are fitted with finger guards. 17 Questions 14 to 17 relate to the following scenario. A test is to be carried out to confirm the continuity of the main protective bonding conductor to the water installation pipework in a commercial premises. Which test method is used for this test? a) Earth fault loop impedance. b) Linked R 1 + R 2 test. c) Long lead test. d) Z s Z e. 18 A 10 mm 2 main protective bonding conductor is 37.5 m in length. What is the expected measured resistance when testing the conductor? a) 6.86 Ω b) 0.70 Ω c) 0.08 Ω d) 0.07 Ω 19 What is the most likely cause of the measured value being much higher than the calculated value? a) Heavy load on the installation. b) Failure to null the test leads. c) Higher than normal ambient temperature. d) Leakage current from computer equipment. Sample Questions 8

20 Questions 20 to 23 apply to the following scenario. An earth fault loop impedance test is to be carried out on a radial circuit to the local isolator, as shown in figure 4. What must the inspector confirm before the test can be undertaken? a) The cpc is disconnected from the MET and the main protective bonding is disconnected. b) The cpc is connected to MET and the main protective bonding is disconnected. c) The cpc is connected and all other earthing and bonding disconnected. d) The cpc and all other earthing and bonding is connected. 21 Questions 20 to 23 apply to the following scenario. An earth fault loop impedance test is to be carried out on a radial circuit to the local isolator, as shown in figure 4. Why can this earth fault loop impedance test be carried out before a test for insulation resistance? Sample Questions 9

a) Because the installation is already energised and in service. b) To maximise inconvenience for the users of the installation. c) Dead tests are not required at a periodic inspection and test. d) The test will confirm there is no degradation of the insulation. 22 Questions 20 to 23 apply to the following scenario. An earth fault loop impedance test is to be carried out on a radial circuit to the local isolator, as shown in figure 4. Why do the test leads used for this test have to comply with GS 38? a) GS 38 is a statutory document. b) To ensure the test results are accurate. c) The test is at a voltage above 50 V AC. d) Leads to GS 38 are required for all tests. Sample Questions 10

23 Questions 20 to 23 apply to the following scenario. An earth fault loop impedance test is to be carried out on a radial circuit to the local isolator, as shown in figure 4. Why would a test to confirm continuity of cpc be unnecessary once the earth fault loop impedance test is completed? a) Reduces the time taken for the periodic inspection. b) Earth fault loop impedance can confirm continuity of cpc. c) Continuity can be proved during insulation resistance testing. d) Dead tests are not required at a periodic inspection and test. 24 A distribution circuit is protected by a BS 88-3 fuse rated 32 A. What is the maximum acceptable measured earth fault loop impedance for this circuit? a) 1.28 Ω b) 1.60 Ω c) 1.70 Ω d) 1.92 Ω 25 What is confirmed by an earth fault loop impedance test on a radial power circuit? a) The line and cpc conductors are the right csa. b) Fault protection is provided for the whole installation. c) The circuit breaker can disconnect the maximum prospective fault current. d) Automatic disconnection of supply will be achieved in the event of a fault. Sample Questions 11

26 Questions 26 to 29 relate to the following scenario Voltage drop of a single-phase distribution circuit supplying a power distribution board in a remote building is to be verified as part of the periodic inspection and testing within a workshop complex. The installation forms part of a public 400/230 V TN-S system. The circuit has a measured R 1+R n value of 0.15 Ω and an I b of 60 A. The circuit protective device has an I n of 80 A, see Figure 5. What is the maximum acceptable voltage drop for this distribution circuit if the highest circuit voltage drop on DB-3B is 5.0 V? a) 11.5 V b) 6.9 V c) 6.5 V d) 1.5 V 27 Questions 26 to 29 relate to the following scenario Voltage drop of a single-phase distribution circuit supplying a power distribution board in a remote building is to be verified as part of the periodic inspection and testing within a workshop complex. The installation forms part of a public 400/230 V TN-S system. The circuit has a measured R 1+R n value of 0.15 Ω and an I b of 60 A. The circuit protective device has an I n of 80 A, see Figure 5. Which are the cable characteristics that affect voltage drop? Sample Questions 12

a) Length and type of insulation. b) Length and cross-sectional area c) Type of insulation and room temperature. d) Ambient temperature and csa. 28 Questions 26 to 29 relate to the following scenario. Voltage drop of a single-phase distribution circuit supplying a power distribution board in a remote building is to be verified as part of the periodic inspection and testing within a workshop complex. The installation forms part of a public 400/230 V TN-S system. The circuit has a measured R 1+R n value of 0.15 Ω and an I b of 60 A. The circuit protective device has an I n of 80 A. What is the voltage drop for this distribution circuit? a) 10.8 V b) 9.0 V c) 7.2 V d) 3.8 V 29 Questions 26 to 29 relate to the following scenario. Voltage drop of a single-phase distribution circuit supplying a power distribution board in a remote building is to be verified as part of the periodic inspection and testing within a workshop complex. The installation forms part of a public 400/230 V TN-S system. The circuit has a measured R 1+R n value of 0.15 Ω and an I b of 60 A. The circuit protective device has an I n of 80 A, see Figure 5. Sample Questions 13

Why is the test to confirm voltage drop carried out? a) To confirm the cable operates at its maximum temperature. b) To confirm correct operation of the protective device. c) To confirm the circuits function as they are intended. d) To confirm the circuit will not be overloaded. 30 Questions 30 to 34 relate to the following scenario. Testing of the RCDs is to be undertaken on the installation which forms part of a TT system, as shown in Figure 6. What is confirmed by testing the 100 ma RCD? a) The RCD can provide overload protection. Sample Questions 14

b) That fault protection is provided for the installation. c) The RCD can disconnect the short circuit current. d) That additional protection is provided for the installation. 31 Questions 30 to 34 relate to the following scenario. Testing of the RCDs is to be undertaken on the installation which forms part of a TT system, as shown in Figure 6. What must be agreed with the users of the installation before the test of the 100 ma RCD can be carried out? a) The test of protective bonding continuity is completed first. b) The evacuation of all personnel from the building. c) The earthing conductor can be disconnected. d) The installation can be completely isolated. 32 Questions 30 to 34 relate to the following scenario. Testing of the RCDs is to be undertaken on the installation which forms part of a TT system, as shown in Figure 6. Sample Questions 15

What is the maximum test current to be applied by the RCD tester, when verifying that the RCD at the origin meets disconnection times? a) 400 ma b) 300 ma c) 100 ma d) 50 ma 33 Questions 30 to 34 relate to the following scenario. Testing of the RCDs is to be undertaken on the installation which forms part of a TT system, as shown in Figure 6. When testing the 30 ma RCD at 5 I n the RCD did not operate because the 100 ma RCD at the origin of the installation tripped out. Sample Questions 16

What is the most likely reason for this RCD tripping? a) The 100 ma RCD has no time delay. b) The 30 ma RCD is to sensitive. c) The test voltage is too high. d) The test current is too low. 34 Questions 30 to 34 relate to the following scenario. Testing of the RCDs is to be undertaken on the installation which forms part of a TT system, as shown in Figure 6. When testing the 30 ma RCD at I n a disconnection time of 400 ms is recorded. What classification code should the inspector record on the report? Sample Questions 17

a) FI b) C3 c) C2 d) C1 35 What is the maximum disconnection time for a 16 A final circuit on a TT installation? a) 500 ms d) 300 ms c) 200 ms d) 30 ms 36 What is the purpose of carrying out a test to determine the prospective fault current at the origin of a three-phase commercial installation? a) The earth fault loop path can carry the fault current. b) The protective devices can safely disconnect the fault current. c) The overcurrent devices will disconnect the earth fault current. d) The overcurrent devices are rated lower than the fault current. 37 The radial circuit, shown in Figure 7, is installed using-single core cables in PVC conduit. The installation is 5 years old and there have been no alterations or additions to the radial circuit. Sample Questions 18

Why would it be unnecessary to carry out a continuity of cpc for this circuit at periodic inspection and test? a) The circuit is installed in PVC conduit and so less likely to be damaged. b) Continuity tests are only necessary if the circuit is in flat profile cable. c) The circuit is only five years old so continuity testing is not required. d) Continuity of cpc can be confirmed during a test of Z s. 38 Insulation resistance testing has been carried out on a six-way lighting distribution board and the individual circuit results are shown in Table 1. What is the value of insulation resistance between Live and Earth for the DB with all the lighting circuits connected? a) 18 MΩ b) 50 MΩ c) 133 MΩ d) 200 MΩ Sample Questions 19

39 What is the most appropriate classification code to be recorded if the insulation resistance for a circuit is measured at 0.90 MΩ between live conductors and Earth? a) FI b) C1 c) C2 d) C3 40 A test is to be carried out to determine the external earth fault loop impedance of an installation forming part of a TN-S system. What is the maximum declared by the Distribution Network Operator for a TN-S supply? a) 0.21 Ω b) 0.35 Ω c) 0.8 Ω d) 21 Ω Sample Questions 20

Useful contacts UK learners General qualification information E: learnersupport@cityandguilds.com International learners General qualification information E: intcg@cityandguilds.com Centres Exam entries, Registrations/enrolment, Certificates, Invoices, Missing or late exam materials, Nominal roll reports, Results E: centresupport@cityandguilds.com Single subject qualifications Exam entries, Results, Certification, Missing or late exam materials, Incorrect exam papers, Forms request (BB, results entry), Exam date and time change E: singlesubjects@cityandguilds.com International awards Results, Entries, Enrolments, Invoices, Missing or late exam materials, Nominal roll reports E: intops@cityandguilds.com Walled Garden Re-issue of password or username, Technical problems, Entries, Results, GOLA, Navigation, User/menu option, Problems E: walledgarden@cityandguilds.com Employer Employer solutions, Mapping, Accreditation, Development Skills, Consultancy E: business_unit@cityandguilds.com Publications Logbooks, Centre documents, Forms, Free literature If you have a complaint, or any suggestions for improvement about any of the services that City & Guilds provides, email: feedbackandcomplaints@cityandguilds.com Sample Questions 21

Published by City & Guilds 1 Giltspur Street London EC1A 9DD www.cityandguilds.com City & Guilds is a registered charity established to promote education and training Sample Questions 22